A new analytical method for the determination of urea-urease system based on biochemical reaction heat induced laser beam deflection is presented in this paper. With the method, the Michaelis constant (K-m) of urease ...A new analytical method for the determination of urea-urease system based on biochemical reaction heat induced laser beam deflection is presented in this paper. With the method, the Michaelis constant (K-m) of urease and apparent inhibition constant (K-i) of some metal ion inhibitors were measured respectively. This method was also used for the quantitative determination of metal ions with satisfactory result.展开更多
In this work we present the results of the optical evaluation of vibrations of a conventional concrete column with a metal frame.In a previous work[1]we reported the optical evaluation of a pure concrete column,withou...In this work we present the results of the optical evaluation of vibrations of a conventional concrete column with a metal frame.In a previous work[1]we reported the optical evaluation of a pure concrete column,without a metal framework.In this evaluation we expected to obtain a noticeably different result,but that was not the case,then the obtained results are surprisingly similar.From the LPD evaluations,the first 12 vibration resonances were found,which fit very well with the basic applied theory(the cantilever theory).Using known average values,we estimate the corresponding column effective length,obtaining an average value of 2.5 m.As in the former case of the concrete column,we find a discrepancy with respect to the length value,measurable from the ground(1.75 m),which can be explained again by the fact that the column and its base were built on inconsistent terrain.展开更多
文摘A new analytical method for the determination of urea-urease system based on biochemical reaction heat induced laser beam deflection is presented in this paper. With the method, the Michaelis constant (K-m) of urease and apparent inhibition constant (K-i) of some metal ion inhibitors were measured respectively. This method was also used for the quantitative determination of metal ions with satisfactory result.
文摘In this work we present the results of the optical evaluation of vibrations of a conventional concrete column with a metal frame.In a previous work[1]we reported the optical evaluation of a pure concrete column,without a metal framework.In this evaluation we expected to obtain a noticeably different result,but that was not the case,then the obtained results are surprisingly similar.From the LPD evaluations,the first 12 vibration resonances were found,which fit very well with the basic applied theory(the cantilever theory).Using known average values,we estimate the corresponding column effective length,obtaining an average value of 2.5 m.As in the former case of the concrete column,we find a discrepancy with respect to the length value,measurable from the ground(1.75 m),which can be explained again by the fact that the column and its base were built on inconsistent terrain.