In this paper,the application strategy of ultrasonic detection technology in the detection of concrete foundation piles is analyzed using a construction project as an example.It includes a basic overview of the projec...In this paper,the application strategy of ultrasonic detection technology in the detection of concrete foundation piles is analyzed using a construction project as an example.It includes a basic overview of the project,an overview of ultrasonic testing technology in bridge concrete pile foundation testing,and an analysis of its practical application in the concrete pile foundation testing of this project.The objective of this analysis is to provide some reference for the application of ultrasonic testing technology and the improvement of the quality of bridge concrete pile foundation testing.展开更多
In order to meet the high precision requirement of wide steel strip in industry field, a novel online measurement of roller profile based on sonic circulation and pulse-echo technology was introduced. All kinds of the...In order to meet the high precision requirement of wide steel strip in industry field, a novel online measurement of roller profile based on sonic circulation and pulse-echo technology was introduced. All kinds of the factors influencing the accuracy of roller profile online measurement were analyzed in detail and error compensation analysis of system was accordingly presented. In order to reduce count error, field program gate array(FPGA) was introduced and a highprecision data acquisition system was designed based on digital phase-shift technology. Experiments indicate that the standard deviation of measure data was 7.27 μm, which showed the feasibility and validity of the proposed method, and realized the roll profile measurement with high precision.展开更多
Magnetic liquid can produce alternative internal pressure under the alternative high-frequency gradient magnetic field.Because it has higher bulk modulus,the internal pressure results in its volume change.Using piezoe...Magnetic liquid can produce alternative internal pressure under the alternative high-frequency gradient magnetic field.Because it has higher bulk modulus,the internal pressure results in its volume change.Using piezoelectric transducers,the ultrasonic wave generated by the vibration of magnetic liquids can be detected,which shows that the magnetic liquids have the magnetostrictive effect and can generate the ultrasonic vibration under the alternative magnetic gradient field.Some nonmagnetic abrasives and rust-proofing agents can be mixed into the magnetic liquids,under the alternative magnetic field,the abrasives held by magnetic liquids grind the surface of the workpieces,and thus,the finishing for the surface with complex shape,mold cavity and inner wall of tiny tubes can be realized.展开更多
In this work, the rheological changes of several crude oil samples exposed to ultrasonic waves for different time intervals in addition to the effect of temperature on viscosity behavior of heavy crude oils were inves...In this work, the rheological changes of several crude oil samples exposed to ultrasonic waves for different time intervals in addition to the effect of temperature on viscosity behavior of heavy crude oils were investigated using a series of steady shear flow and oscillatory tests. The colloidal structural evolutions of flocs in oil samples were illustrated by analysis of the size distribution of flocculated asphaltene particles (confocal microscopy tests). The rheological investigations indicate that the ultrasonic irradiation dissolved heavy components in crude oil. After ultrasonic treatment, the Kouh-e-Mond crude oil was found to be pseudoplastic. In addition, confocal microscopy confirms that there was an optimum duration for ultrasonic irradiation, at which the viscosity and flocculation rate of asphaltenic crude oils reduced to the minimum values. The optimum was found to be approximately 40 min for the Kouh-e-Mond crude oil. Experimental results illustrate that the ultrasonic irradiation could disaggregate heavy colloid components in crude oil, and breakdown of asphaltene molecules would only occur in a specific time interval of irradiation. Also according to the temperature sweep test, the oil temperature rise caused by ultrasonic irradiation was not the main reason for theological changes of the crude oil and this alteration may be due to physical and chemical phenomena induced by sonication in crude oil.展开更多
Ultrasonic seismic model experiment plays an important role in engineering multi wave seismic prospecting(EMSP), which has been used to do the complex engineering seismic exploration. It is introduced that the applic...Ultrasonic seismic model experiment plays an important role in engineering multi wave seismic prospecting(EMSP), which has been used to do the complex engineering seismic exploration. It is introduced that the application of the technology in quality test of Yongjiang river submarine tunnel tube foundation in the paper. The material of the model was got from on the spot. The successful test has been made with results of the model experiment.展开更多
Because the UT (ultrasonic testing) flexible probe technology may be an appropriate answer to examine components with uneven surface, AREVA has developed an industrial application of the CEA's (French Atomic Energ...Because the UT (ultrasonic testing) flexible probe technology may be an appropriate answer to examine components with uneven surface, AREVA has developed an industrial application of the CEA's (French Atomic Energy and Alternative Energies) flexible phased arrays sensors. As a "first of a kind" project, the challenges faced were significant, including developing a phased array smart probe suitable for industrial use on rather simple but large scale geometries, permitting UT propagation within a constraining media structure and then targeting a qualification according to ENIQ (European Network for Inspection Qualification) methodology. A prototype flexible probe, designed for UT validation, and final flexible linear array probes permitting the UT behavior (as, e.g., detection and sizing from diffraction type echoes) to be maintained on wavy coupling surfaces, have been manufactured. These probes include a profilemeter with optical sensors control and a specifically designed coupling circuit (avoiding probe housing tightness issues). Qualification has been performed using open test blocks, (where known "defects" exist, for procedure qualification), and blind test blocks, (where "defects" are unknown, for qualification of testing personnel). One open test bloc was customized to represent a "real" surface condition, with gaps up to 2.5 mm under the regular rigid probes. AREVAI/BGSI in Germany was selected to lead the project, with assistance in development and manufacturing sub-contracted to "CEA/LIST" laboratory, and the companies "IMASONIC" and "M2M". This paper describes the development of these probes and explains a few features (ENIQ qualification objectives fulfilled, UT data acquired on actual perturbed surface) that made their industrial implementation successful.展开更多
文摘In this paper,the application strategy of ultrasonic detection technology in the detection of concrete foundation piles is analyzed using a construction project as an example.It includes a basic overview of the project,an overview of ultrasonic testing technology in bridge concrete pile foundation testing,and an analysis of its practical application in the concrete pile foundation testing of this project.The objective of this analysis is to provide some reference for the application of ultrasonic testing technology and the improvement of the quality of bridge concrete pile foundation testing.
文摘In order to meet the high precision requirement of wide steel strip in industry field, a novel online measurement of roller profile based on sonic circulation and pulse-echo technology was introduced. All kinds of the factors influencing the accuracy of roller profile online measurement were analyzed in detail and error compensation analysis of system was accordingly presented. In order to reduce count error, field program gate array(FPGA) was introduced and a highprecision data acquisition system was designed based on digital phase-shift technology. Experiments indicate that the standard deviation of measure data was 7.27 μm, which showed the feasibility and validity of the proposed method, and realized the roll profile measurement with high precision.
基金Sponsored by Zhejiang Province Scientific and Technological Key Task Program (2007C21025)Ningbo Science and Technological Key Task Program (2007B10010)
文摘Magnetic liquid can produce alternative internal pressure under the alternative high-frequency gradient magnetic field.Because it has higher bulk modulus,the internal pressure results in its volume change.Using piezoelectric transducers,the ultrasonic wave generated by the vibration of magnetic liquids can be detected,which shows that the magnetic liquids have the magnetostrictive effect and can generate the ultrasonic vibration under the alternative magnetic gradient field.Some nonmagnetic abrasives and rust-proofing agents can be mixed into the magnetic liquids,under the alternative magnetic field,the abrasives held by magnetic liquids grind the surface of the workpieces,and thus,the finishing for the surface with complex shape,mold cavity and inner wall of tiny tubes can be realized.
文摘In this work, the rheological changes of several crude oil samples exposed to ultrasonic waves for different time intervals in addition to the effect of temperature on viscosity behavior of heavy crude oils were investigated using a series of steady shear flow and oscillatory tests. The colloidal structural evolutions of flocs in oil samples were illustrated by analysis of the size distribution of flocculated asphaltene particles (confocal microscopy tests). The rheological investigations indicate that the ultrasonic irradiation dissolved heavy components in crude oil. After ultrasonic treatment, the Kouh-e-Mond crude oil was found to be pseudoplastic. In addition, confocal microscopy confirms that there was an optimum duration for ultrasonic irradiation, at which the viscosity and flocculation rate of asphaltenic crude oils reduced to the minimum values. The optimum was found to be approximately 40 min for the Kouh-e-Mond crude oil. Experimental results illustrate that the ultrasonic irradiation could disaggregate heavy colloid components in crude oil, and breakdown of asphaltene molecules would only occur in a specific time interval of irradiation. Also according to the temperature sweep test, the oil temperature rise caused by ultrasonic irradiation was not the main reason for theological changes of the crude oil and this alteration may be due to physical and chemical phenomena induced by sonication in crude oil.
文摘Ultrasonic seismic model experiment plays an important role in engineering multi wave seismic prospecting(EMSP), which has been used to do the complex engineering seismic exploration. It is introduced that the application of the technology in quality test of Yongjiang river submarine tunnel tube foundation in the paper. The material of the model was got from on the spot. The successful test has been made with results of the model experiment.
文摘Because the UT (ultrasonic testing) flexible probe technology may be an appropriate answer to examine components with uneven surface, AREVA has developed an industrial application of the CEA's (French Atomic Energy and Alternative Energies) flexible phased arrays sensors. As a "first of a kind" project, the challenges faced were significant, including developing a phased array smart probe suitable for industrial use on rather simple but large scale geometries, permitting UT propagation within a constraining media structure and then targeting a qualification according to ENIQ (European Network for Inspection Qualification) methodology. A prototype flexible probe, designed for UT validation, and final flexible linear array probes permitting the UT behavior (as, e.g., detection and sizing from diffraction type echoes) to be maintained on wavy coupling surfaces, have been manufactured. These probes include a profilemeter with optical sensors control and a specifically designed coupling circuit (avoiding probe housing tightness issues). Qualification has been performed using open test blocks, (where known "defects" exist, for procedure qualification), and blind test blocks, (where "defects" are unknown, for qualification of testing personnel). One open test bloc was customized to represent a "real" surface condition, with gaps up to 2.5 mm under the regular rigid probes. AREVAI/BGSI in Germany was selected to lead the project, with assistance in development and manufacturing sub-contracted to "CEA/LIST" laboratory, and the companies "IMASONIC" and "M2M". This paper describes the development of these probes and explains a few features (ENIQ qualification objectives fulfilled, UT data acquired on actual perturbed surface) that made their industrial implementation successful.