期刊文献+
共找到306篇文章
< 1 2 16 >
每页显示 20 50 100
Characteristics of laser-induced breakdown spectroscopy of liquid slag
1
作者 董长言 于洪霞 +4 位作者 孙兰香 李洋 刘修业 周平 黄少文 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期86-93,共8页
Rapid online analysis of liquid slag is essential for optimizing the quality and energy efficiency of steel production. To investigate the key factors that affect the online measurement of refined slag using laser-ind... Rapid online analysis of liquid slag is essential for optimizing the quality and energy efficiency of steel production. To investigate the key factors that affect the online measurement of refined slag using laser-induced breakdown spectroscopy(LIBS), this study examined the effects of slag composition and temperature on the intensity and stability of the LIBS spectra. The experimental temperature was controlled at three levels: 1350℃, 1400℃, and 1450℃. The results showed that slag composition and temperature significantly affected the intensity and stability of the LIBS spectra. Increasing the Fe content and temperature in the slag reduces its viscosity, resulting in an enhanced intensity and stability of the LIBS spectra. Additionally, 42 refined slag samples were quantitatively analyzed for Fe, Si, Ca, Mg, Al, and Mn at 1350℃, 1400℃, and 1450℃.The normalized full spectrum combined with partial least squares(PLS) quantification modeling was used, using the Ca Ⅱ 317.91 nm spectral line as an internal standard. The results show that using the internal standard normalization method can significantly reduce the influence of spectral fluctuations. Meanwhile, a temperature of 1450℃ has been found to yield superior results compared to both 1350℃ and 1400℃, and it is advantageous to conduct a quantitative analysis of the slag when it is in a “water-like” state with low viscosity. 展开更多
关键词 laser-induced breakdown spectroscopy(libs) SLAG temperature COMPOSITION VISCOSITY internal standard normalization partial least squares(PLS)
下载PDF
Incorporating empirical knowledge into data-driven variable selection for quantitative analysis of coal ash content by laser-induced breakdown spectroscopy
2
作者 吕一涵 宋惟然 +1 位作者 侯宗余 王哲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期148-156,共9页
Laser-induced breakdown spectroscopy(LIBS)has become a widely used atomic spectroscopic technique for rapid coal analysis.However,the vast amount of spectral information in LIBS contains signal uncertainty,which can a... Laser-induced breakdown spectroscopy(LIBS)has become a widely used atomic spectroscopic technique for rapid coal analysis.However,the vast amount of spectral information in LIBS contains signal uncertainty,which can affect its quantification performance.In this work,we propose a hybrid variable selection method to improve the performance of LIBS quantification.Important variables are first identified using Pearson's correlation coefficient,mutual information,least absolute shrinkage and selection operator(LASSO)and random forest,and then filtered and combined with empirical variables related to fingerprint elements of coal ash content.Subsequently,these variables are fed into a partial least squares regression(PLSR).Additionally,in some models,certain variables unrelated to ash content are removed manually to study the impact of variable deselection on model performance.The proposed hybrid strategy was tested on three LIBS datasets for quantitative analysis of coal ash content and compared with the corresponding data-driven baseline method.It is significantly better than the variable selection only method based on empirical knowledge and in most cases outperforms the baseline method.The results showed that on all three datasets the hybrid strategy for variable selection combining empirical knowledge and data-driven algorithms achieved the lowest root mean square error of prediction(RMSEP)values of 1.605,3.478 and 1.647,respectively,which were significantly lower than those obtained from multiple linear regression using only 12 empirical variables,which are 1.959,3.718 and 2.181,respectively.The LASSO-PLSR model with empirical support and 20 selected variables exhibited a significantly improved performance after variable deselection,with RMSEP values dropping from 1.635,3.962 and 1.647 to 1.483,3.086 and 1.567,respectively.Such results demonstrate that using empirical knowledge as a support for datadriven variable selection can be a viable approach to improve the accuracy and reliability of LIBS quantification. 展开更多
关键词 laser-induced breakdown spectroscopy(libs) coal ash content quantitative analysis variable selection empirical knowledge partial least squares regression(PLSR)
下载PDF
Estimating the yield stress of soft materials via laser-induced breakdown spectroscopy
3
作者 龚书航 李亚举 +7 位作者 钱东斌 叶晋瑞 赵扣 曾强 陈良文 张少锋 杨磊 马新文 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期428-432,共5页
Taking three typical soft samples prepared respectively by loose packings of 77-,95-,and 109-μm copper grains as examples,we perform an experiment to investigate the energy-dependent laser-induced breakdown spectrosc... Taking three typical soft samples prepared respectively by loose packings of 77-,95-,and 109-μm copper grains as examples,we perform an experiment to investigate the energy-dependent laser-induced breakdown spectroscopy(LIBS)of soft materials.We discovered a reversal phenomenon in the trend of energy dependence of plasma emission intensity:increasing initially and then decreasing separated by a well-defined critical energy.The trend reversal is attributed to the laser-induced recoil pressure at the critical energy just matching the sample's yield strength.As a result,a one-to-one correspondence can be well established between the samples'yield stress and the critical energy that is easily obtainable from LIBS measurements.This allows us to propose an innovative method for estimating the yield stress of soft materials via LIBS with attractive advantages including in-situ remote detection,real-time data collection,and minimal destructive to sample. 展开更多
关键词 laser-induced breakdown spectroscopy soft materials yield stress
下载PDF
Laser-induced breakdown spectroscopy as a method for millimeter-scale inspection of surface flatness
4
作者 Jinrui YE Yaju LI +8 位作者 Zhao ZHANG Xinwei WANG Kewei TAO Qiang ZENG Liangwen CHEN Dongbin QIAN Shaofeng ZHANG Lei YANG Xinwen MA 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第9期148-155,共8页
A non-contact method for millimeter-scale inspection of material surface flatness via Laser-Induced Breakdown Spectroscopy(LIBS)is investigated experimentally.The experiment is performed using a planished surface of a... A non-contact method for millimeter-scale inspection of material surface flatness via Laser-Induced Breakdown Spectroscopy(LIBS)is investigated experimentally.The experiment is performed using a planished surface of an alloy steel sample to simulate its various flatness,ranging from 0 to 4.4 mm,by adjusting the laser focal plane to the surface distance with a step length of 0.2 mm.It is found that LIBS measurements are successful in inspecting the flatness differences among these simulated cases,implying that the method investigated here is feasible.It is also found that,for achieving the inspection of surface flatness within such a wide range,when univariate analysis is applied,a piecewise calibration model must be constructed.This is due to the complex dependence of plasma formation conditions on the surface flatness,which inevitably complicates the inspection procedure.To solve the problem,a multivariate analysis with the help of Back-Propagation Neural Network(BPNN)algorithms is applied to further construct the calibration model.By detailed analysis of the model performance,we demonstrate that a unified calibration model can be well established based on BPNN algorithms for unambiguous millimeter-scale range inspection of surface flatness with a resolution of about 0.2 mm. 展开更多
关键词 laser-induced breakdown spectroscopy machine learning surface flatness
下载PDF
Estimating the grain size of microgranular material using laser-induced breakdown spectroscopy combined with machine learning algorithms
5
作者 张朝 李亚举 +9 位作者 杨光辉 曾强 李小龙 陈良文 钱东斌 孙对兄 苏茂根 杨磊 张少锋 马新文 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第5期129-137,共9页
Recent work has validated a new method for estimating the grain size of microgranular materials in the range of tens to hundreds of micrometers using laser-induced breakdown spectroscopy(LIBS).In this situation,a piec... Recent work has validated a new method for estimating the grain size of microgranular materials in the range of tens to hundreds of micrometers using laser-induced breakdown spectroscopy(LIBS).In this situation,a piecewise univariate model must be constructed to estimate grain size due to the complex dependence of the plasma formation environment on grain size.In the present work,we tentatively construct a unified calibration model suitable for LIBS-based estimation of those grain sizes.Specifically,two unified multivariate calibration models are constructed based on back-propagation neural network(BPNN)algorithms using feature selection strategies with and without considering prior information.By detailed analysis of the performances of the two multivariate models,it was found that a unified calibration model can be successfully constructed based on BPNN algorithms for estimating the grain size in the range of tens to hundreds of micrometers.It was also found that the model constructed with a priorguided feature selection strategy had better prediction performance.This study has practical significance in developing the technology for material analysis using LIBS,especially when the LIBS signal exhibits a complex dependence on the material parameter to be estimated. 展开更多
关键词 laser-induced breakdown spectroscopy machine learning randomly packed microgranular materials
下载PDF
Research on batch multielement rapid quantitative analysis based on the standard curve-assisted calibration-free laserinduced breakdown spectroscopy method
6
作者 Weiwei HAN Duixiong SUN +7 位作者 Guoding ZHANG Honglin WANG Kai GUO Yuzhuo ZHANG Haoliang WANG Denghong ZHANG Chenzhong DONG Maogen SU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第9期156-164,共9页
This study proposes a batch rapid quantitative analysis method for multiple elements by combining the advantages of standard curve(SC)and calibration-free laser-induced breakdown spectroscopy(CF-LIBS)technology to ach... This study proposes a batch rapid quantitative analysis method for multiple elements by combining the advantages of standard curve(SC)and calibration-free laser-induced breakdown spectroscopy(CF-LIBS)technology to achieve synchronous,rapid,and accurate measurement of elements in a large number of samples,namely,SC-assisted CF-LIBS.Al alloy standard samples,divided into calibration and test samples,were applied to validate the proposed method.SC was built based on the characteristic line of Pb and Cr in the calibration sample,and the contents of Pb and Cr in the test sample were calculated with relative errors of 6%and 4%,respectively.SC built using Cr with multiple characteristic lines yielded better calculation results.The relative contents of ten elements in the test sample were calculated using CF-LIBS.Subsequently,the SC-assisted CF-LIBS was executed,with the majority of the calculation relative errors falling within the range of 2%-5%.Finally,the Al and Na contents of the Al alloy were predicted.The results demonstrate that it effectively enables the rapid and accurate quantitative analysis of multiple elements after a single-element SC analysis of the tested samples.Furthermore,this quantitative analysis method was successfully applied to soil and Astragalus samples,realizing an accurate calculation of the contents of multiple elements.Thus,it is important to advance the LIBS quantitative analysis and its related applications. 展开更多
关键词 laser-induced breakdown spectroscopy standard curve quantitative analysis multielement
下载PDF
A data selection method for matrix effects and uncertainty reduction for laser-induced breakdown spectroscopy 被引量:1
7
作者 龙杰 宋惟然 +1 位作者 侯宗余 王哲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第7期82-89,共8页
Severe matrix effects and high signal uncertainty are two key bottlenecks for the quantitative performance and wide applications of laser-induced breakdown spectroscopy(LIBS).Based on the understanding that the superp... Severe matrix effects and high signal uncertainty are two key bottlenecks for the quantitative performance and wide applications of laser-induced breakdown spectroscopy(LIBS).Based on the understanding that the superposition of both matrix effects and signal uncertainty directly affects plasma parameters and further influences spectral intensity and LIBS quantification performance,a data selection method based on plasma temperature matching(DSPTM)was proposed to reduce both matrix effects and signal uncertainty.By selecting spectra with smaller plasma temperature differences for all samples,the proposed method was able to build up the quantification model to rely more on spectra with smaller matrix effects and signal uncertainty,therefore improving final quantification performance.When applied to quantitative analysis of the zinc content in brass alloys,it was found that both accuracy and precision were improved using either a univariate model or multiple linear regression(MLR).More specifically,for the univariate model,the root-mean-square error of prediction(RMSEP),the determination coefficients(R^(2))and relative standard derivation(RSD)were improved from 3.30%,0.864 and 18.8%to 1.06%,0.986 and 13.5%,respectively;while for MLR,RMSEP,R^(2)and RSD were improved from 3.22%,0.871 and 26.2%to 1.07%,0.986 and 17.4%,respectively.These results prove that DSPTM can be used as an effective method to reduce matrix effects and improve repeatability by selecting reliable data. 展开更多
关键词 laser-induced breakdown spectroscopy(libs) quantification UNCERTAINTY univariate/multivariate analysis matrix effects temperature matching
下载PDF
The comparison of manganese spectral lines for self-absorption reduction in LIBS using laser-induced fluorescence 被引量:1
8
作者 唐云 李菁锋 +5 位作者 马世祥 胡桢麟 彭旭翔 周伟平 袁晓 沈萌 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第6期82-87,共6页
The detection of manganese(Mn)in steel by laser-induced breakdown spectroscopy(LIBS)provides essential information for steelmaking.However,self-absorption greatly disrupts the LIBS spectral lines of Mn with high conte... The detection of manganese(Mn)in steel by laser-induced breakdown spectroscopy(LIBS)provides essential information for steelmaking.However,self-absorption greatly disrupts the LIBS spectral lines of Mn with high content.In this study,to minimize self-absorption for Mn spectral lines in LIBS,laser-induced fluorescence(LIF)was applied.Compared with conventional LIBS,the self-absorption factors(α)of Mn I 403.08,403.31,and 403.45 nm lines were reduced by 90%,88%,and 88%,respectively;the root mean square errors of crossvalidation were decreased by 88%,85%,and 87%,respectively;the average relative errors were reduced by 93%,90%,and 91%,respectively;and average relative standard deviations were decreased by 29%,32%,and 33%,respectively.The LIBS-LIF was shown to successfully minimize the self-absorption effect and spectral intensity fluctuation and improve detection accuracy. 展开更多
关键词 laser-induced breakdown spectroscopy SELF-ABSORPTION libs-LIF
下载PDF
Self-absorption effects of laser-induced breakdown spectroscopy under different gases and gas pressures 被引量:1
9
作者 王崧宁 张殿鑫 +6 位作者 陈楠 何亚雄 张红 柯川 许涛 陈永亮 赵勇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第2期155-162,共8页
The self-absorption effect is one of the main factors affecting the quantitative analysis accuracy of laser-induced breakdown spectroscopy.In this paper,the self-absorption effects of laserinduced 7050 Al alloy plasma... The self-absorption effect is one of the main factors affecting the quantitative analysis accuracy of laser-induced breakdown spectroscopy.In this paper,the self-absorption effects of laserinduced 7050 Al alloy plasma under different pressures in air,Ar,and N2have been studied.Compared with air and N2,Ar significantly enhances the spectral signal.Furthermore,the spectral self-absorption coefficient is calculated to quantify the degree of self-absorption,and the influences of gas species and gas pressure on self-absorption are analyzed.In addition,it is found that the spectral intensity fluctuates with the change of pressure of three gases.It can also be seen that the fluctuation of spectral intensity with pressure is eliminated after correcting,which indicates that the self-absorption leads to the fluctuation of spectral intensity under different pressures.The analysis shows that the evolution of optical thin spectral lines with pressure in different gases is mainly determined by the gas properties and the competition between plasma confinement and Rayleigh–Taylor instability. 展开更多
关键词 self-absorption coefficient ambient gases gas pressure laser-induced breakdown spectroscopy
下载PDF
Laser-Induced Breakdown Spectroscopy (LIBS) Applied in the Differentiation of <i>Arabica</i>and <i>Robusta</i>Coffee
10
作者 Abigail María Díaz Guerrero Luis Vidal Ponce Cabrera +1 位作者 Teresa Flores Reyes Rogelio Ortega Izaguirre 《Optics and Photonics Journal》 2017年第10期181-195,共15页
Coffee is one of the most consumed and commercialized crops in the world, which is why there is a potential risk to find arabica coffee (an expensive variety) adulterated with robusta coffee (a cheaper variety). The c... Coffee is one of the most consumed and commercialized crops in the world, which is why there is a potential risk to find arabica coffee (an expensive variety) adulterated with robusta coffee (a cheaper variety). The currently used technique for certifying coffee, High Performance Liquid Chromatography (HPLC), requires the sample to be subjected to a chemical treatment prior to analysis;in addition, the equipment is bulky and can not be moved easily. Laser Induced Breakdown Spectroscopy (LIBS) is a technique which does not require that samples be subjected to a chemical pretreatment, and equipment is small and portable, this can save valuable time in coffee trading. The purpose of this research was to demonstrate that LIBS can be applied to solve various problems related with the coffee authentication. Green coffee pills with different concentrations of arabica and robusta varieties were analyzed by LIBS, the results were used in the construction of calibration curves for the detection of the degree of simulated adulteration in coffee. It was found that the relative intensities of Ca (392.4 nm), Sr (407.1 nm), N (500.5 nm) and Na (588.7 nm), as well as the intensity ratios of Ca II (392.4 nm)/N I (500.5 nm), Sr I (407.1 nm)/N I (500.5 nm)and N I (500.5 nm)/Na I (588.7 nm) can be used for this purpose. It is concluded that the differentiation of coffee and the detection of its adulteration is possible with the use of LIBS. Further, with the use of an Artificial Neural Network (ANN) of type Multilayer Perceptron, it was possible to correctly classify the spectra of arabica and robusta roasted coffee. 展开更多
关键词 Laser Induced breakdown spectroscopy (libs) Calibration Curves Artificial Neural Network (ANN) Multilayer PERCEPTRON
下载PDF
Detection and quantification of Pb and Cr in oysters using laser-induced breakdown spectroscopy
11
作者 闫清霞 田野 +7 位作者 李颖 林洪 贾自文 卢渊 俞进 孙琛 白雪石 Vincent DETALLE 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第4期195-203,共9页
The quantitative determination of heavy metals in aquatic products is of great importance for food security issues.Laser-induced breakdown spectroscopy(LIBS)has been used in a variety of foodstuff analysis,but is stil... The quantitative determination of heavy metals in aquatic products is of great importance for food security issues.Laser-induced breakdown spectroscopy(LIBS)has been used in a variety of foodstuff analysis,but is still limited by its low sensitivity when targeting trace heavy metals.In this work,we compare three sample enrichment methods,namely drying,carbonization,and ashing,for increasing detection sensitivity by LIBS analysis for Pb and Cr in oyster samples.The results demonstrate that carbonization can remove a significant amount of the contributions of organic elements C,H,N and O;meanwhile,the signals of the metallic elements such as Cu,Pb,Sr,Ca,Cr and Mg are enhanced by3–6 times after carbonization,and further enhanced by 5–9 times after ashing.Such enhancement is not only due to the more concentrated metallic elements in the sample compared to the dried ones,but also the unifying of the matter in carbonized and ashed samples from which higher plasma temperature and electron density are observed.This condition favors the detection of trace elements.According to the calibration curves with univariate and multivariate analysis,the ashing method is considered to be the best choice.The limits of detection of the ashing method are 0.52 mg kg-1 for Pb and0.08 mg kg-1 for Cr,which can detect the presence of heavy metals in the oysters exceeding the maximum limits of Pb and Cr required by the Chinese national standard.This method provides a promising application for the heavy metal contamination monitoring in the aquatic product industry. 展开更多
关键词 laser-induced breakdown spectroscopy(libs) heavy metal detection signal enhancement sample preparation method quantification OYSTERS
下载PDF
Matrix effect suppressing in the element analysis of soils by laser-induced breakdown spectroscopy with acoustic correction
12
作者 何智权 刘莉 +6 位作者 郝中骐 徐智帅 王奇 卢颖 赵梓屹 史久林 何兴道 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第12期97-104,共8页
Laser-induced breakdown spectroscopy(LIBS)has been used for soil analysis,but its measurement accuracy is often influenced by matrix effects of different kinds of soils.In this work,a method for matrix effect suppress... Laser-induced breakdown spectroscopy(LIBS)has been used for soil analysis,but its measurement accuracy is often influenced by matrix effects of different kinds of soils.In this work,a method for matrix effect suppressing was developed using laser-induced plasma acoustic signals to correct the original spectrum,thereby improving the analysis accuracy of the soil elements.A good linear relationship was investigated firstly between the original spectral intensity and the acoustic signals.The relative standard deviations(RSDs)of Mg,Ca,Sr,and Ba elements were then calculated for both the original spectrum and the spectrum with the acoustic correction,and the RSDs were significantly reduced with the acoustic correction.Finally,calibration curves of MgⅠ285.213 nm,CaⅠ422.673 nm,SrⅠ460.733 nm and BaⅡ455.403 nm were established to assess the analytical performance of the proposed acoustic correction method.The values of the determination coefficient(R~2)of the calibration curves for Mg,Ca,Sr,and Ba elements,corrected by the acoustic amplitude,are improved from 0.9845,0.9588,0.6165,and 0.6490 to 0.9876,0.9677,0.8768,and 0.8209,respectively.The values of R~2 of the calibration curves corrected by the acoustic energy are further improved to 0.9917,0.9827,0.8835,and 0.8694,respectively.These results suggest that the matrix effect of LIBS on soils can be clearly improved by using acoustic correction,and acoustic energy correction works more efficiently than acoustic amplitude correction.This work provides a simple and efficient method for correcting matrix effects in the element analysis of soils by acoustic signals. 展开更多
关键词 laser-induced breakdown spectroscopy acoustic correction matrix effect calibration curve relative standard deviation
下载PDF
Rock and Soil Classification Using PLS-DA and SVM Combined with a Laser-Induced Breakdown Spectroscopy Library 被引量:6
13
作者 杨光 乔淑君 +2 位作者 陈鹏飞 丁宇 田地 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第8期656-663,共8页
Laser-induced breakdown spectroscopy (LIBS) has become a powerful technology in geological applications. The correct identification of rocks and soils is critical to many geological projects. In this study, LIBS dat... Laser-induced breakdown spectroscopy (LIBS) has become a powerful technology in geological applications. The correct identification of rocks and soils is critical to many geological projects. In this study, LIBS database software with a user-friendly and intuitive interface is developed based on Windows, consisting of a database module and a sample identification module. The database module includes a basic database containing LIBS persistent lines for elements and a dedicated geological database containing LIBS emission lines for several rock and soil reference standards. The module allows easy use of the data. A sample identification module based on partial least squares discriminant analysis (PLS-DA) or support vector machine (SVM) algorithms enables users to classify groups of unknown spectra. The developed system was used to classify rock and soil data sets in a dedicated database and the results demonstrate that the system is capable of fast and accurate classification of rocks and soils, and is thus useful for the detection of geological materials. 展开更多
关键词 laser-induced breakdown spectroscopy spectral database geomaterial clas-sification partial least squares discriminant analysis (PLS-DA) support vector machine(SVM)
下载PDF
高精度煤质成分快速定量分析LIBS系统研究 被引量:1
14
作者 刘树林 王猛 +3 位作者 李安 张颖 刘晓东 刘瑞斌 《光学精密工程》 EI CAS CSCD 北大核心 2024年第10期1470-1480,共11页
煤质成分的快速、高精度定量分析是工厂对能源高效利用的重要环节。本文通过利用搭建的激光诱导击穿技术煤质快速分析仪,对所采集煤样工业特性固定碳(FixC),灰分(Ash),干燥无灰基的挥发分(Vdaf),热值(Q)进行了定量测量,并对测得的数据... 煤质成分的快速、高精度定量分析是工厂对能源高效利用的重要环节。本文通过利用搭建的激光诱导击穿技术煤质快速分析仪,对所采集煤样工业特性固定碳(FixC),灰分(Ash),干燥无灰基的挥发分(Vdaf),热值(Q)进行了定量测量,并对测得的数据与实验室人工测量数据进行对比分析,检验得出该方法在煤质分析方面准确快速。通过对设备稳定性和动态精密度的测试,结果表明了快速煤质分析仪具有较高的稳定性,满足国标规定值。在预测灰分值分布跨度为5%~60%的煤样时,通过增加样品量,增加模型中对大灰分煤样的预测权重,实现预测均方根误差RMSEP<1%的预测精度,挥发分和全硫的RMSEP<1%,热值的RMSEP<0.18 MJ/kg。预测结果均达到工业分析要求,可以满足工业现场的应用需求,具有应用于煤质在线检测方面的广阔前景。 展开更多
关键词 激光诱导击穿光谱 定量分析 快速煤质分析 稳定性
下载PDF
基于LIBS光谱实现燃煤企业碳排放量高精度快速预测
15
作者 王猛 刘树林 +4 位作者 刘晓东 孙浩瀚 张颖 李安 刘瑞斌 《西安科技大学学报》 CAS 北大核心 2024年第3期597-603,共7页
准确预测煤炭的碳排放数据是实现中国“双碳”目标的重要基础。在煤炭入炉前完成碳排放量数据和煤质指标的精确、快速预测,将转变目前“先排放,后检测”的碳排放数据计算方式,对落实“双碳”战略意义重大。以煤炭碳含量和煤质指标的精... 准确预测煤炭的碳排放数据是实现中国“双碳”目标的重要基础。在煤炭入炉前完成碳排放量数据和煤质指标的精确、快速预测,将转变目前“先排放,后检测”的碳排放数据计算方式,对落实“双碳”战略意义重大。以煤炭碳含量和煤质指标的精准预评估为研究目标,通过自行搭建激光诱导击穿光谱(Laser Induced Breakdown Spectroscopy,LIBS)系统和LIBS光谱统计分析,利用主成分分析-偏最小二乘(PCA-PLS)结合小样本算法对训练集进行回归训练,建立了一种煤炭的碳排放预测模型,并通过在新疆A电厂和山东B电厂中的实际应用,证明了LIBS系统在煤质指标分析中的可靠性。结果表明:所提出的预测方法与传统方法相比绝对误差最大为0.0256 t,表现出较好的碳排放预测能力。所提方法可以用于燃煤企业碳排放量的精准预测,为实现煤炭碳排放和煤质指标的预评估提供了一种较为高效的技术解决路径。 展开更多
关键词 激光诱导击穿光谱技术 碳排放 高精度快速预测
下载PDF
Quantitative analysis of C, Si, Mn, Ni, Cr and Cu in low-alloy steel under ambient conditions via laser-induced breakdown spectroscopy 被引量:4
16
作者 Dan LUO Ying LIU +3 位作者 Xiangyu LI Zhenyang ZHAO Shigong WANG Yong ZHANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第7期152-158,共7页
A diode-pumped solid-state laser (DPSSL) with a high energetic stability and long service life is applied to ablate the steel samples instead of traditional Nd:YAG laser pumped by a xenon lamp, and several factors,... A diode-pumped solid-state laser (DPSSL) with a high energetic stability and long service life is applied to ablate the steel samples instead of traditional Nd:YAG laser pumped by a xenon lamp, and several factors, such as laser pulse energy, repetition rate and argon flow rate, that influence laser-induced breakdown spectroscopy (LIBS) analytical performance are investigated in detail. Under the optimal experiment conditions, the relative standard deviations for C, Si, Mn, Ni, Cr and Cu are 3.3%-8.9%, 0.9%-2.8%, 1.2%-4.1%, 1.7%-3.0%, 1.1%-3.4% and 2.5%-8.5%, respectively, with the corresponding relative errors of 1.1%-7.9%, 1.0%-6.3%, 0.4%-3.9%, 1.5%-6.3%, 1.2%-4.0% and 1.2%-6.4%. Compared with the results of the traditional spark discharge optical emission spectrometry technique, the analytical performance of LIBS is just a little inferior due to the less stable laser-induced plasma and smaller amount of ablated sample by the laser. However, the precision, detection limits and accuracy of LIBS obtained in our present work were sufficient to meet the requirements for process analysis. These technical performances of higher stability of output energy and longer service life for DPSSL, in comparison to the Q-switch laser pumped by xeon lamp, qualify it well for the real time online analysis for different industrial applications. 展开更多
关键词 laser-induced breakdown spectroscopy (libs diode-pumped solid-state laser(DPSSL) optical emission spectrometry laser-induced plasma
下载PDF
Characterization of the Delamination Defects in Marine Steel Using Laser-Induced Breakdown Spectroscopy 被引量:2
17
作者 杨春 贾云海 +5 位作者 张勇 李冬玲 刘佳 陈吉文 陈永彦 刘英 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第8期671-675,共5页
In this paper, two types of comparison analyses, bulk analysis and defect analysis, were carried out for marine steel. The results of laser-induced breakdown spectroscopy (LIBS) were compared with those of spark opt... In this paper, two types of comparison analyses, bulk analysis and defect analysis, were carried out for marine steel. The results of laser-induced breakdown spectroscopy (LIBS) were compared with those of spark optical emission spectrometry (Spark-OES) and scanning electron microscopy/energy dispersion spectroscopy (SEM/EDS) in the bulk and defect analyses. The comparison of the bulk analyses shows that the chemical contents of C, Si, Mn, P, S and Cr obtained from LIBS agree well with those determined using Spark-OES. The LIBS is slightly less precise than Spark-OES. Defects were characterized in the two-dimensional distribution analysis mode for Al, Mg, Ca, Si and other elements. Both the LIBS and SEM/EDS results show the enrichment of Al, Mg, Ca and Si at the defect position and the two methods agree well with each other. SEM/EDS cannot provide information about the difference in the chemical constituents when the differences between the defect position and the normal position are not significant. However, LIBS can provide this information, meaning that the sensitivity of LIBS is higher than that of SEM/EDS. LIBS can be used to rapidly characterize marine steel defects and provide guidance for improving metallurgical processes. 展开更多
关键词 laser-induced breakdown spectroscopy (libs marine steel defects in ironand steel
下载PDF
Parameters Optimization of Laser-Induced Breakdown Spectroscopy Experimental Setup for the Case with Beam Expander 被引量:1
18
作者 王鑫 张雷 +6 位作者 樊娟娟 李郁芳 弓瑶 董磊 马维光 尹王保 贾锁堂 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第11期914-918,共5页
Improvement of measurement precision and repeatability is one of the issues currently faced by the laser-induced breakdown spectroscopy (LIBS) technique, which is expected to be capable of precise and accurate quant... Improvement of measurement precision and repeatability is one of the issues currently faced by the laser-induced breakdown spectroscopy (LIBS) technique, which is expected to be capable of precise and accurate quantitative analysis. It was found that there was great potential to improve the signal quality and repeatability by reducing the laser beam divergence angle using a suitable beam expander (BE). In the present work, the influences of several experimental parameters for the case with BE are studied in order to optimize the analytical performances: the signal to noise ratio (SNR) and the relative standard deviation (RSD). We demonstrate that by selecting the optimal experimental parameters, the BE-included LIBS setup can give higher SNR and lower RSD values of the line intensity normalized by the whole spectrum area. For validation purposes, support vector machine (SVM) regression combined with principal component analysis (PCA) was used to establish a calibration model to realize the quantitative analysis of the ash content. Good agreement has been found between the laboratory measurement results from the LIBS method and those from the traditional method. The measurement accuracy presented here for ash content analysis is estimated to be 0.31%, while the average relative error is 2.36%. 展开更多
关键词 laser-induced breakdown spectroscopy (libs relative standard deviation(RSD) signal to noise ratio (SNR) beam expander (BE) support vector machine (SVM)
下载PDF
Accurate method based on data filtering for quantitative multi-element analysis of soils using CF-LIBS
19
作者 韩伟伟 孙对兄 +7 位作者 张国鼎 董光辉 崔小娜 申金成 王浩亮 张登红 董晨钟 苏茂根 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第6期149-158,共10页
To obtain more stable spectral data for accurate quantitative analysis of multi-element,especially for the large-area in-situ elements detection of soils, we propose a method for a multielement quantitative analysis o... To obtain more stable spectral data for accurate quantitative analysis of multi-element,especially for the large-area in-situ elements detection of soils, we propose a method for a multielement quantitative analysis of soils using calibration-free laser-induced breakdown spectroscopy(CF-LIBS) based on data filtering. In this study, we analyze a standard soil sample doped with two heavy metal elements, Cu and Cd, with a specific focus on the line of Cu I324.75 nm for filtering the experimental data of multiple sample sets. Pre-and post-data filtering,the relative standard deviation for Cu decreased from 30% to 10%, The limits of detection(LOD)values for Cu and Cd decreased by 5% and 4%, respectively. Through CF-LIBS, a quantitative analysis was conducted to determine the relative content of elements in soils. Using Cu as a reference, the concentration of Cd was accurately calculated. The results show that post-data filtering, the average relative error of the Cd decreases from 11% to 5%, indicating the effectiveness of data filtering in improving the accuracy of quantitative analysis. Moreover, the content of Si, Fe and other elements can be accurately calculated using this method. To further correct the calculation, the results for Cd was used to provide a more precise calculation. This approach is of great importance for the large-area in-situ heavy metals and trace elements detection in soil, as well as for rapid and accurate quantitative analysis. 展开更多
关键词 laser-induced breakdown spectroscopy SOIL data filtering quantitative analysis multielement
下载PDF
A theoretical study of the signal enhancement mechanism of coaxial DP-LIBS
20
作者 宋震 王俊霄 +11 位作者 王钢 张雷 王树青 张婉飞 马晓飞 刘珍荣 罗学彬 马维光 叶泽甫 朱竹君 尹王保 贾锁堂 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第5期156-164,共9页
In the field of dual-pulse laser-induced breakdown spectroscopy(DP-LIBS)research,the pursuit of methods for determining pulse intervals and other parameters quickly and conveniently in order to achieve optimal spectra... In the field of dual-pulse laser-induced breakdown spectroscopy(DP-LIBS)research,the pursuit of methods for determining pulse intervals and other parameters quickly and conveniently in order to achieve optimal spectral signal enhancement is paramount.To aid researchers in identification of optimal signal enhancement conditions and more accurate interpretation of the underlying signal enhancement mechanisms,theoretical simulations of the spatiotemporal processes of coaxial DP-LIBS-induced plasma have been established in this work.Using a model based on laser ablation and two-dimensional axisymmetric fluid dynamics,plasma evolutions during aluminum–magnesium alloy laser ablation under single-pulse and coaxial dualpulse excitations have been simulated.The influences of factors,such as delay time,laser fluence,plasma temperature,and particle number density,on the DP-LIBS spectral signals are investigated.Under pulse intervals ranging from 50 to 1500 ns,the time evolutions of spectral line intensity,dual-pulse emission enhancement relative to the single-pulse results,laser irradiance,spatial distribution of plasma temperature and species number density,as well as laser irradiance shielded by plasma have been obtained.The study indicates that the main reason behind the radiation signal enhancement in coaxial DP-LIBS-induced plasma is attributed to the increased species number density and plasma temperature caused by the second laser,and it is inferred that the shielding effect of the plasma mainly occurs in the boundary layer of the stagnation point flow over the target surface.This research provides a theoretical basis for experimental research,parameter optimization,and signal enhancement tracing in DP-LIBS. 展开更多
关键词 laser-induced plasma radiation fluid dynamics model double pulse laser-induced breakdown spectroscopy(DP-libs) laser ablation signal enhancement mechanism
下载PDF
上一页 1 2 16 下一页 到第
使用帮助 返回顶部