A combination of spark discharge and nanoparticle-enhanced laser-induced plasma spectroscopy is investigated.Depositing Au nanoparticles at the surface of a brass target can enhance the coupling of the target and the ...A combination of spark discharge and nanoparticle-enhanced laser-induced plasma spectroscopy is investigated.Depositing Au nanoparticles at the surface of a brass target can enhance the coupling of the target and the laser.More atoms in the brass sample are excited.As a secondary excitation source,spark discharge reheats the generated plasma,which further amplifies the enhancement results of nanoparticles.The spectral intensity with the spark discharge increases more obviously with nanoparticle concentration increasing than without the spark discharge.Also,plasma temperature and electron density are calculated by the Boltzmann plot and Stark broadening.The changes in the plasma temperature and electron density are consistent with the spectral emission changes.展开更多
Taking three typical soft samples prepared respectively by loose packings of 77-,95-,and 109-μm copper grains as examples,we perform an experiment to investigate the energy-dependent laser-induced breakdown spectrosc...Taking three typical soft samples prepared respectively by loose packings of 77-,95-,and 109-μm copper grains as examples,we perform an experiment to investigate the energy-dependent laser-induced breakdown spectroscopy(LIBS)of soft materials.We discovered a reversal phenomenon in the trend of energy dependence of plasma emission intensity:increasing initially and then decreasing separated by a well-defined critical energy.The trend reversal is attributed to the laser-induced recoil pressure at the critical energy just matching the sample's yield strength.As a result,a one-to-one correspondence can be well established between the samples'yield stress and the critical energy that is easily obtainable from LIBS measurements.This allows us to propose an innovative method for estimating the yield stress of soft materials via LIBS with attractive advantages including in-situ remote detection,real-time data collection,and minimal destructive to sample.展开更多
Recent work has validated a new method for estimating the grain size of microgranular materials in the range of tens to hundreds of micrometers using laser-induced breakdown spectroscopy(LIBS).In this situation,a piec...Recent work has validated a new method for estimating the grain size of microgranular materials in the range of tens to hundreds of micrometers using laser-induced breakdown spectroscopy(LIBS).In this situation,a piecewise univariate model must be constructed to estimate grain size due to the complex dependence of the plasma formation environment on grain size.In the present work,we tentatively construct a unified calibration model suitable for LIBS-based estimation of those grain sizes.Specifically,two unified multivariate calibration models are constructed based on back-propagation neural network(BPNN)algorithms using feature selection strategies with and without considering prior information.By detailed analysis of the performances of the two multivariate models,it was found that a unified calibration model can be successfully constructed based on BPNN algorithms for estimating the grain size in the range of tens to hundreds of micrometers.It was also found that the model constructed with a priorguided feature selection strategy had better prediction performance.This study has practical significance in developing the technology for material analysis using LIBS,especially when the LIBS signal exhibits a complex dependence on the material parameter to be estimated.展开更多
Rapid online analysis of liquid slag is essential for optimizing the quality and energy efficiency of steel production. To investigate the key factors that affect the online measurement of refined slag using laser-ind...Rapid online analysis of liquid slag is essential for optimizing the quality and energy efficiency of steel production. To investigate the key factors that affect the online measurement of refined slag using laser-induced breakdown spectroscopy(LIBS), this study examined the effects of slag composition and temperature on the intensity and stability of the LIBS spectra. The experimental temperature was controlled at three levels: 1350℃, 1400℃, and 1450℃. The results showed that slag composition and temperature significantly affected the intensity and stability of the LIBS spectra. Increasing the Fe content and temperature in the slag reduces its viscosity, resulting in an enhanced intensity and stability of the LIBS spectra. Additionally, 42 refined slag samples were quantitatively analyzed for Fe, Si, Ca, Mg, Al, and Mn at 1350℃, 1400℃, and 1450℃.The normalized full spectrum combined with partial least squares(PLS) quantification modeling was used, using the Ca Ⅱ 317.91 nm spectral line as an internal standard. The results show that using the internal standard normalization method can significantly reduce the influence of spectral fluctuations. Meanwhile, a temperature of 1450℃ has been found to yield superior results compared to both 1350℃ and 1400℃, and it is advantageous to conduct a quantitative analysis of the slag when it is in a “water-like” state with low viscosity.展开更多
Laser-induced breakdown spectroscopy(LIBS)has become a widely used atomic spectroscopic technique for rapid coal analysis.However,the vast amount of spectral information in LIBS contains signal uncertainty,which can a...Laser-induced breakdown spectroscopy(LIBS)has become a widely used atomic spectroscopic technique for rapid coal analysis.However,the vast amount of spectral information in LIBS contains signal uncertainty,which can affect its quantification performance.In this work,we propose a hybrid variable selection method to improve the performance of LIBS quantification.Important variables are first identified using Pearson's correlation coefficient,mutual information,least absolute shrinkage and selection operator(LASSO)and random forest,and then filtered and combined with empirical variables related to fingerprint elements of coal ash content.Subsequently,these variables are fed into a partial least squares regression(PLSR).Additionally,in some models,certain variables unrelated to ash content are removed manually to study the impact of variable deselection on model performance.The proposed hybrid strategy was tested on three LIBS datasets for quantitative analysis of coal ash content and compared with the corresponding data-driven baseline method.It is significantly better than the variable selection only method based on empirical knowledge and in most cases outperforms the baseline method.The results showed that on all three datasets the hybrid strategy for variable selection combining empirical knowledge and data-driven algorithms achieved the lowest root mean square error of prediction(RMSEP)values of 1.605,3.478 and 1.647,respectively,which were significantly lower than those obtained from multiple linear regression using only 12 empirical variables,which are 1.959,3.718 and 2.181,respectively.The LASSO-PLSR model with empirical support and 20 selected variables exhibited a significantly improved performance after variable deselection,with RMSEP values dropping from 1.635,3.962 and 1.647 to 1.483,3.086 and 1.567,respectively.Such results demonstrate that using empirical knowledge as a support for datadriven variable selection can be a viable approach to improve the accuracy and reliability of LIBS quantification.展开更多
Two-dimensional diagnosis of laser-induced zirconium(Zr)plasma has been experimentally performed using the time-of-flight method by employing Faraday cups in addition to electric and magnetic probes.The characteristic...Two-dimensional diagnosis of laser-induced zirconium(Zr)plasma has been experimentally performed using the time-of-flight method by employing Faraday cups in addition to electric and magnetic probes.The characteristic parameters of laser-induced Zr plasma have been evaluated as a function of different laser irradiances ranging from 4.5 to 11.7 GW cm-2 at different axial positions of 1–4 cm with a fixed radial distance of 2 cm.A well-supporting correlation between the plume parameters and the laser-plasma-produced spontaneous electric and magnetic(E and B)fields was established.The measurements of the characteristic parameters and spontaneously induced fields were observed to have an increasing trend with the increasing laser irradiance.However,when increasing the spatial distance in both the axial and radial directions,the plasma parameters(electron/ion number density,temperature and kinetic energy)did not show either continuously increasing or decreasing trends due to various kinetic and dynamic processes during the spatial evolution of the plume.However,the E and B fields were observed to be always diffusing away from the target.The radial component of electron number densities remained higher than the axial number density component,whereas the axial ion number density at all laser irradiances and axial distances remained higher than the radial ion number density.The higher axial self-generated electric field(SGEF)values than radial SGEF values are correlated with the effective charge-separation mechanism of electrons and ions.The generation of a self-generated magnetic field is observed dominantly in the radial direction at increasing laser irradiance as compared to the axial one due to the deflection of fast-moving electrons and the persistence of two-electron temperature on the radial axis.展开更多
The self-absorption effect is one of the main factors affecting the quantitative analysis accuracy of laser-induced breakdown spectroscopy.In this paper,the self-absorption effects of laserinduced 7050 Al alloy plasma...The self-absorption effect is one of the main factors affecting the quantitative analysis accuracy of laser-induced breakdown spectroscopy.In this paper,the self-absorption effects of laserinduced 7050 Al alloy plasma under different pressures in air,Ar,and N2have been studied.Compared with air and N2,Ar significantly enhances the spectral signal.Furthermore,the spectral self-absorption coefficient is calculated to quantify the degree of self-absorption,and the influences of gas species and gas pressure on self-absorption are analyzed.In addition,it is found that the spectral intensity fluctuates with the change of pressure of three gases.It can also be seen that the fluctuation of spectral intensity with pressure is eliminated after correcting,which indicates that the self-absorption leads to the fluctuation of spectral intensity under different pressures.The analysis shows that the evolution of optical thin spectral lines with pressure in different gases is mainly determined by the gas properties and the competition between plasma confinement and Rayleigh–Taylor instability.展开更多
Severe matrix effects and high signal uncertainty are two key bottlenecks for the quantitative performance and wide applications of laser-induced breakdown spectroscopy(LIBS).Based on the understanding that the superp...Severe matrix effects and high signal uncertainty are two key bottlenecks for the quantitative performance and wide applications of laser-induced breakdown spectroscopy(LIBS).Based on the understanding that the superposition of both matrix effects and signal uncertainty directly affects plasma parameters and further influences spectral intensity and LIBS quantification performance,a data selection method based on plasma temperature matching(DSPTM)was proposed to reduce both matrix effects and signal uncertainty.By selecting spectra with smaller plasma temperature differences for all samples,the proposed method was able to build up the quantification model to rely more on spectra with smaller matrix effects and signal uncertainty,therefore improving final quantification performance.When applied to quantitative analysis of the zinc content in brass alloys,it was found that both accuracy and precision were improved using either a univariate model or multiple linear regression(MLR).More specifically,for the univariate model,the root-mean-square error of prediction(RMSEP),the determination coefficients(R^(2))and relative standard derivation(RSD)were improved from 3.30%,0.864 and 18.8%to 1.06%,0.986 and 13.5%,respectively;while for MLR,RMSEP,R^(2)and RSD were improved from 3.22%,0.871 and 26.2%to 1.07%,0.986 and 17.4%,respectively.These results prove that DSPTM can be used as an effective method to reduce matrix effects and improve repeatability by selecting reliable data.展开更多
Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based...Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based polymer that is,among other things,interesting as a substrate for laser-induced breakdown spectroscopy analysis of liquid samples.This study aimed to determine the optimal experimental conditions for obtaining neutral and ionized C spectral lines and C2 and CN molecular band emission suitable for spectrochemical purposes.Evaluation of plasma parameters was done using several spectroscopic techniques.Stark profiles of appropriate C ionic lines were used to determine electron number density.The ratio of the integral intensity of ionic-to-atomic C spectral lines was used to determine the ionization temperature.A spectral emission of C2 Swan and CN violet bands system was used to determine the temperature of the colder,peripheral parts of plasma.We critically analyzed the use of molecular emission bands as a tool for plasma diagnostics and suggested methods for possible improvements.展开更多
When a high energy nanosecond(ns)laser induces breakdown in the air,the plasma density generated in the rarefied atmosphere is much smaller than that at normal pressure.It is associated with a relatively lower absorpt...When a high energy nanosecond(ns)laser induces breakdown in the air,the plasma density generated in the rarefied atmosphere is much smaller than that at normal pressure.It is associated with a relatively lower absorption coefficient and reduces energy loss of the laser beam at low pressure.In this paper,the general transmission characterizations of a Joule level 10 ns 1064 nm focused laser beam are investigated both theoretically and experimentally under different pressures.The evolution of the electron density(n_(e)),the changes in electron temperature(T_(e))and the variation of laser intensity(I)are employed for numerical analyses in the simulation model.For experiments,four optical image transfer systems with focal length(f)of 200 mm are placed in a chamber and employed to focus the laser beam and produce plasmas at the focus.The results suggest that the transmittance increases obviously with the decreasing pressure and the plasma channels on the transmission path can be observed by the self-illumination.The simulation results agree well with the experimental data.The numerical model presents that the maximum n_e at the focus can reach 10^(19)cm^(-3),which is far below the critical density(n_(c)).As a result,the laser beam is not completely shielded by the plasmas.展开更多
Laser-induced breakdown spectroscopy(LIBS)has been used for soil analysis,but its measurement accuracy is often influenced by matrix effects of different kinds of soils.In this work,a method for matrix effect suppress...Laser-induced breakdown spectroscopy(LIBS)has been used for soil analysis,but its measurement accuracy is often influenced by matrix effects of different kinds of soils.In this work,a method for matrix effect suppressing was developed using laser-induced plasma acoustic signals to correct the original spectrum,thereby improving the analysis accuracy of the soil elements.A good linear relationship was investigated firstly between the original spectral intensity and the acoustic signals.The relative standard deviations(RSDs)of Mg,Ca,Sr,and Ba elements were then calculated for both the original spectrum and the spectrum with the acoustic correction,and the RSDs were significantly reduced with the acoustic correction.Finally,calibration curves of MgⅠ285.213 nm,CaⅠ422.673 nm,SrⅠ460.733 nm and BaⅡ455.403 nm were established to assess the analytical performance of the proposed acoustic correction method.The values of the determination coefficient(R~2)of the calibration curves for Mg,Ca,Sr,and Ba elements,corrected by the acoustic amplitude,are improved from 0.9845,0.9588,0.6165,and 0.6490 to 0.9876,0.9677,0.8768,and 0.8209,respectively.The values of R~2 of the calibration curves corrected by the acoustic energy are further improved to 0.9917,0.9827,0.8835,and 0.8694,respectively.These results suggest that the matrix effect of LIBS on soils can be clearly improved by using acoustic correction,and acoustic energy correction works more efficiently than acoustic amplitude correction.This work provides a simple and efficient method for correcting matrix effects in the element analysis of soils by acoustic signals.展开更多
The quantitative determination of heavy metals in aquatic products is of great importance for food security issues.Laser-induced breakdown spectroscopy(LIBS)has been used in a variety of foodstuff analysis,but is stil...The quantitative determination of heavy metals in aquatic products is of great importance for food security issues.Laser-induced breakdown spectroscopy(LIBS)has been used in a variety of foodstuff analysis,but is still limited by its low sensitivity when targeting trace heavy metals.In this work,we compare three sample enrichment methods,namely drying,carbonization,and ashing,for increasing detection sensitivity by LIBS analysis for Pb and Cr in oyster samples.The results demonstrate that carbonization can remove a significant amount of the contributions of organic elements C,H,N and O;meanwhile,the signals of the metallic elements such as Cu,Pb,Sr,Ca,Cr and Mg are enhanced by3–6 times after carbonization,and further enhanced by 5–9 times after ashing.Such enhancement is not only due to the more concentrated metallic elements in the sample compared to the dried ones,but also the unifying of the matter in carbonized and ashed samples from which higher plasma temperature and electron density are observed.This condition favors the detection of trace elements.According to the calibration curves with univariate and multivariate analysis,the ashing method is considered to be the best choice.The limits of detection of the ashing method are 0.52 mg kg-1 for Pb and0.08 mg kg-1 for Cr,which can detect the presence of heavy metals in the oysters exceeding the maximum limits of Pb and Cr required by the Chinese national standard.This method provides a promising application for the heavy metal contamination monitoring in the aquatic product industry.展开更多
The laser induced plasma dynamics of graphite material are investigated by optical emission spectroscopy. Abla- tion and excitation of the graphite material is performed by using an 1064nm Nd:YAG laser in different a...The laser induced plasma dynamics of graphite material are investigated by optical emission spectroscopy. Abla- tion and excitation of the graphite material is performed by using an 1064nm Nd:YAG laser in different ambient pressures. Characteristics of graphite spectra as line intensity variations and signal-to-noise ratio are presented with a main focus on the influence of the ambient pressure on the interaction of laser-induced graphite plasma with an ambient environment. Atomic emission lines are utilized to investigate the dynamical behavior of plasma, such as the excitation temperature and electron density, to describe emission differences under different ambient conditions. The excitation temperature and plasma electron density are the primary factors which contribute to the differences among the atomic carbon emission at different ambient pressures. Reactions between the plasma species and ambient gas, and the total molecular number are the main factors influencing molecular carbon emis- sion. The influence of laser energy on the plasma interaction with environment is also investigated to demonstrate the dynamical behavior of carbon species so that it can be utilized to optimize plasma fluctuations.展开更多
The combination of spark discharge and laser-induced breakdown spectroscopy (LIBS) is called spark discharge assisted LIBS.It works under laser-plasma triggered spark discharge mode,and shows its ability to enhance sp...The combination of spark discharge and laser-induced breakdown spectroscopy (LIBS) is called spark discharge assisted LIBS.It works under laser-plasma triggered spark discharge mode,and shows its ability to enhance spectral emission intensity.This work uses a femtosecond laser as the light souuce,since femtosecond laser has many advantages in laser-induced plasma compared with nanosecond laser,meanwhile,the study on femtosecond LIBS with spark discharge is rare.Time-resolved spectroscopy of spark discharge assisted femtosecond LIBS was investigated under different discharge voltages and laser energies.The results showed that the spectral intensity was significantly enhanced by using spark discharge compared with LIBS alone.And,the spectral emission intensity using spark discharge assisted LIBS increased with the increase in the laser energy.In addition,at low laser energy,there was an obvious delay on the discharge time compared with high laser energy,and the discharge time with positive voltage was different from that with negative voltage.展开更多
Laser-induced steel plasma is generated by focusing a Q-switched Nd:YAG visible laser(532 nm wavelength) with an irradiance of 1 x 109 W/cm2 on a steel sample in air at atmospheric pressure.An Echelle spectrograph ...Laser-induced steel plasma is generated by focusing a Q-switched Nd:YAG visible laser(532 nm wavelength) with an irradiance of 1 x 109 W/cm2 on a steel sample in air at atmospheric pressure.An Echelle spectrograph coupled with a gateable intensified charge-coupled detector is used to record the plasma emissions.Using time-resolved spectroscopic measurements of the plasma emissions,the temperature and electron number density of the steel plasma are determined for many times of the detector delay.The validity of the assumption by the spectroscopic methods that the laser-induced plasma(LIP) is optically thin and is also in local thermodynamic equilibrium(LTE) has been evaluated for many delay times.From the temporal evolution of the intensity ratio of two Fe I lines and matching it with its theoretical value,the delay times where the plasma is optically thin and is also in LTE are found to be 800 ns,900 ns and 1000 ns.展开更多
In this paper,we investigate the time-resolved spectroscopy of collinear femtosecond(fs)and nanosecond(ns)dual-pulse(DP)laser-induced plasmas.A copper target was used as an experimental sample,and the fs laser was con...In this paper,we investigate the time-resolved spectroscopy of collinear femtosecond(fs)and nanosecond(ns)dual-pulse(DP)laser-induced plasmas.A copper target was used as an experimental sample,and the fs laser was considered as the time zero reference point.The interpulse delay between fs and ns laser beams was 3μs.First,we compared the time-resolved peak intensities of Cu(I)lines from Cu plasmas induced by fs+ns and ns+fs DP lasers with collinear configuration.The results showed that compared with the ns+fs DP,the fs+ns DP laser-induced Cu plasmas had stronger peak intensities and longer lifetimes.Second,we calculated time-resolved plasma temperatures using the Boltzmann plot with three spectral lines at Cu(I)510.55,515.32 and 521.82 nm.In addition,time-resolved electron densities were calculated based on Stark broadening with Cu(I)line at 521.82 nm.It was found that compared with ns+fs DP,the plasma temperatures and electron densities of the Cu plasmas induced by fs+ns DP laser were higher.Finally,we observed images of ablation craters under the two experimental conditions and found that the fs+ns DP laser-produced stronger ablation,which corresponded to stronger plasma emission.展开更多
Laser-induced plasmas of dual-pulse fiber-optic laser-induced breakdown spectroscopy with different pulse energy ratios are studied by using the optical emission spectroscopy(OES)and fast imaging.The energy of the two...Laser-induced plasmas of dual-pulse fiber-optic laser-induced breakdown spectroscopy with different pulse energy ratios are studied by using the optical emission spectroscopy(OES)and fast imaging.The energy of the two laser pulses is independently adjusted within 0–30 m J with the total energy fixed at 30 m J.The inter-pulse delay remains 450 ns constantly.As the energy share of the first pulse increases,a similar bimodal variation trend of line intensities is observed.The two peaks are obtained at the point where the first pulse is half or twice of the second one,and the maximum spectral enhancement is at the first peak.The bimodal variation trend is induced by the change in the dominated mechanism of dual-pulse excitation with the trough between the two peaks caused by the weak coupling between the two mechanisms.By increasing the first pulse energy,there is a transition from the ablation enhancement dominance near the first peak to the plasma reheating dominance near the second peak.The calculations of plasma temperature and electron number density are consistent with the bimodal trend,which have the values of 17024.47 K,2.75×10^(17)cm;and 12215.93 K,1.17×10^(17)cm;at a time delay of 550 ns.In addition,the difference between the two peaks decreases with time delay.With the increase in the first pulse energy share,the plasma morphology undergoes a transformation from hemispherical to shiny-dot and to oblate-cylinder structure during the second laser irradiation from the recorded images by using an intensified charge-coupled device(ICCD)camera.Correspondingly,the peak expansion distance of the plasma front first decreases significantly from 1.99 mm in the single-pulse case to 1.34 mm at 12/18(dominated by ablation enhancement)and then increases slightly with increasing the plasma reheating effect.The variations in plasma dynamics verify that the change of pulse energy ratios leads to a transformation in the dual-pulse excitation mechanism.展开更多
For the first time, absolute densities of atomic nitrogen in its ground state (N4S) have been measured in hot dry and humid air plasma columns under post-discharge regime. The determination of space-resolved absolute ...For the first time, absolute densities of atomic nitrogen in its ground state (N4S) have been measured in hot dry and humid air plasma columns under post-discharge regime. The determination of space-resolved absolute densities leads to obtain the dissociation degrees of molecular nitrogen in the plasma. The hot plasmas are generated inside an upstream gas-conditioning cell at 600 mbar when the air gas flow is directly injected at 10 slm in a microwave resonant cavity (2.45 GHz, 1 kW) placed in the downstream side. Density measurements based on laser induced fluorescence spectroscopy with two-photon excitation (TALIF), are more particularly performed along the radial and axial positions of the plasma column. Calibration of TALIF signals is performed in situ (i.e. in the same gas-conditioning cell but without plasma) using an air gas mixture containing krypton. Optical emission spectroscopy is considered to estimate the rotational gas temperature by adding a small amount of H2 in dry air to better detect OH (A-X) spectra. The rotational temperatures in humid air plasma column (50% of humidity) are larger than those of dry air plasma column by practically 30% near the nozzle of resonant cavity on the axis of the plasma column. This is partly due to attachment heating processes initiated by water vapor. A maximum of the measured absolute nitrogen density is also observed near the nozzle which is also larger for humid air plasma column. The obtained dissociation degrees of molecular nitrogen in both dry and humid air plasma along the air plasma column are lower than the cases where only thermodynamic equilibrium is assumed. This is characteristic of the absence of chemical and energetic equilibria not yet reached in the air plasma column dominated by recombination processes.展开更多
The detection of manganese(Mn)in steel by laser-induced breakdown spectroscopy(LIBS)provides essential information for steelmaking.However,self-absorption greatly disrupts the LIBS spectral lines of Mn with high conte...The detection of manganese(Mn)in steel by laser-induced breakdown spectroscopy(LIBS)provides essential information for steelmaking.However,self-absorption greatly disrupts the LIBS spectral lines of Mn with high content.In this study,to minimize self-absorption for Mn spectral lines in LIBS,laser-induced fluorescence(LIF)was applied.Compared with conventional LIBS,the self-absorption factors(α)of Mn I 403.08,403.31,and 403.45 nm lines were reduced by 90%,88%,and 88%,respectively;the root mean square errors of crossvalidation were decreased by 88%,85%,and 87%,respectively;the average relative errors were reduced by 93%,90%,and 91%,respectively;and average relative standard deviations were decreased by 29%,32%,and 33%,respectively.The LIBS-LIF was shown to successfully minimize the self-absorption effect and spectral intensity fluctuation and improve detection accuracy.展开更多
The influence of the energy of femtosecond laser pulses on the intensity of Fe I (371.99 nm) emission line and the continuous spectrum of the plasma generated on the surface of Fe^3+ water solution by a Ti: sapphi...The influence of the energy of femtosecond laser pulses on the intensity of Fe I (371.99 nm) emission line and the continuous spectrum of the plasma generated on the surface of Fe^3+ water solution by a Ti: sapphire laser radiation with pulse duration 〈45 fs and energies up to 7 mJ is determined. A calibration curve was obtained for Fe3+ concentration range from 0.5 g/L to the limit of detection in water solution, and its saturation was detected for concentrations above 0.25 g/L, which is ascribed to self-absorption. The 3σ- limit of detection obtained for Fe in water solution is 2.6 mg/L in the case of 7 mJ laser pulse energy. It is found that an increase of laser pulse energy insignificantly affects on LOD in the time-resolved LIBS and leads to a slight improvement of the limit of detection.展开更多
基金Project supported by the National Key Research and Development Program of China(Grant No.2019YFA0307701)the National Natural Science Foundation of China(Grant Nos.11674128,11674124,and 11974138)the Jilin Provincial Scientific and Technological Development Program,China(Grant No.20170101063JC)。
文摘A combination of spark discharge and nanoparticle-enhanced laser-induced plasma spectroscopy is investigated.Depositing Au nanoparticles at the surface of a brass target can enhance the coupling of the target and the laser.More atoms in the brass sample are excited.As a secondary excitation source,spark discharge reheats the generated plasma,which further amplifies the enhancement results of nanoparticles.The spectral intensity with the spark discharge increases more obviously with nanoparticle concentration increasing than without the spark discharge.Also,plasma temperature and electron density are calculated by the Boltzmann plot and Stark broadening.The changes in the plasma temperature and electron density are consistent with the spectral emission changes.
基金Project supported by the National Key Research and Development Program of China(Grant No.2017YFA0402300)the National Natural Science Foundation of China(Grant Nos.U2241288 and 11974359).
文摘Taking three typical soft samples prepared respectively by loose packings of 77-,95-,and 109-μm copper grains as examples,we perform an experiment to investigate the energy-dependent laser-induced breakdown spectroscopy(LIBS)of soft materials.We discovered a reversal phenomenon in the trend of energy dependence of plasma emission intensity:increasing initially and then decreasing separated by a well-defined critical energy.The trend reversal is attributed to the laser-induced recoil pressure at the critical energy just matching the sample's yield strength.As a result,a one-to-one correspondence can be well established between the samples'yield stress and the critical energy that is easily obtainable from LIBS measurements.This allows us to propose an innovative method for estimating the yield stress of soft materials via LIBS with attractive advantages including in-situ remote detection,real-time data collection,and minimal destructive to sample.
基金supported in part by the National Key Research and Development Program of China(No.2017YFA0402300)National Natural Science Foundation of China(Nos.U2241288 and 11974359)Major Science and Technology Project of Gansu Province(No.22ZD6FA021-5)。
文摘Recent work has validated a new method for estimating the grain size of microgranular materials in the range of tens to hundreds of micrometers using laser-induced breakdown spectroscopy(LIBS).In this situation,a piecewise univariate model must be constructed to estimate grain size due to the complex dependence of the plasma formation environment on grain size.In the present work,we tentatively construct a unified calibration model suitable for LIBS-based estimation of those grain sizes.Specifically,two unified multivariate calibration models are constructed based on back-propagation neural network(BPNN)algorithms using feature selection strategies with and without considering prior information.By detailed analysis of the performances of the two multivariate models,it was found that a unified calibration model can be successfully constructed based on BPNN algorithms for estimating the grain size in the range of tens to hundreds of micrometers.It was also found that the model constructed with a priorguided feature selection strategy had better prediction performance.This study has practical significance in developing the technology for material analysis using LIBS,especially when the LIBS signal exhibits a complex dependence on the material parameter to be estimated.
基金financially supported by the National Key R&D Program Projects of China (No.2021YFB3202402)National Natural Science Foundation of China (No.62173321)。
文摘Rapid online analysis of liquid slag is essential for optimizing the quality and energy efficiency of steel production. To investigate the key factors that affect the online measurement of refined slag using laser-induced breakdown spectroscopy(LIBS), this study examined the effects of slag composition and temperature on the intensity and stability of the LIBS spectra. The experimental temperature was controlled at three levels: 1350℃, 1400℃, and 1450℃. The results showed that slag composition and temperature significantly affected the intensity and stability of the LIBS spectra. Increasing the Fe content and temperature in the slag reduces its viscosity, resulting in an enhanced intensity and stability of the LIBS spectra. Additionally, 42 refined slag samples were quantitatively analyzed for Fe, Si, Ca, Mg, Al, and Mn at 1350℃, 1400℃, and 1450℃.The normalized full spectrum combined with partial least squares(PLS) quantification modeling was used, using the Ca Ⅱ 317.91 nm spectral line as an internal standard. The results show that using the internal standard normalization method can significantly reduce the influence of spectral fluctuations. Meanwhile, a temperature of 1450℃ has been found to yield superior results compared to both 1350℃ and 1400℃, and it is advantageous to conduct a quantitative analysis of the slag when it is in a “water-like” state with low viscosity.
基金financial supports from National Natural Science Foundation of China(No.62205172)Huaneng Group Science and Technology Research Project(No.HNKJ22-H105)Tsinghua University Initiative Scientific Research Program and the International Joint Mission on Climate Change and Carbon Neutrality。
文摘Laser-induced breakdown spectroscopy(LIBS)has become a widely used atomic spectroscopic technique for rapid coal analysis.However,the vast amount of spectral information in LIBS contains signal uncertainty,which can affect its quantification performance.In this work,we propose a hybrid variable selection method to improve the performance of LIBS quantification.Important variables are first identified using Pearson's correlation coefficient,mutual information,least absolute shrinkage and selection operator(LASSO)and random forest,and then filtered and combined with empirical variables related to fingerprint elements of coal ash content.Subsequently,these variables are fed into a partial least squares regression(PLSR).Additionally,in some models,certain variables unrelated to ash content are removed manually to study the impact of variable deselection on model performance.The proposed hybrid strategy was tested on three LIBS datasets for quantitative analysis of coal ash content and compared with the corresponding data-driven baseline method.It is significantly better than the variable selection only method based on empirical knowledge and in most cases outperforms the baseline method.The results showed that on all three datasets the hybrid strategy for variable selection combining empirical knowledge and data-driven algorithms achieved the lowest root mean square error of prediction(RMSEP)values of 1.605,3.478 and 1.647,respectively,which were significantly lower than those obtained from multiple linear regression using only 12 empirical variables,which are 1.959,3.718 and 2.181,respectively.The LASSO-PLSR model with empirical support and 20 selected variables exhibited a significantly improved performance after variable deselection,with RMSEP values dropping from 1.635,3.962 and 1.647 to 1.483,3.086 and 1.567,respectively.Such results demonstrate that using empirical knowledge as a support for datadriven variable selection can be a viable approach to improve the accuracy and reliability of LIBS quantification.
文摘Two-dimensional diagnosis of laser-induced zirconium(Zr)plasma has been experimentally performed using the time-of-flight method by employing Faraday cups in addition to electric and magnetic probes.The characteristic parameters of laser-induced Zr plasma have been evaluated as a function of different laser irradiances ranging from 4.5 to 11.7 GW cm-2 at different axial positions of 1–4 cm with a fixed radial distance of 2 cm.A well-supporting correlation between the plume parameters and the laser-plasma-produced spontaneous electric and magnetic(E and B)fields was established.The measurements of the characteristic parameters and spontaneously induced fields were observed to have an increasing trend with the increasing laser irradiance.However,when increasing the spatial distance in both the axial and radial directions,the plasma parameters(electron/ion number density,temperature and kinetic energy)did not show either continuously increasing or decreasing trends due to various kinetic and dynamic processes during the spatial evolution of the plume.However,the E and B fields were observed to be always diffusing away from the target.The radial component of electron number densities remained higher than the axial number density component,whereas the axial ion number density at all laser irradiances and axial distances remained higher than the radial ion number density.The higher axial self-generated electric field(SGEF)values than radial SGEF values are correlated with the effective charge-separation mechanism of electrons and ions.The generation of a self-generated magnetic field is observed dominantly in the radial direction at increasing laser irradiance as compared to the axial one due to the deflection of fast-moving electrons and the persistence of two-electron temperature on the radial axis.
基金National Key Research and Development Program of China(Nos.2017YFE0301306,2017YFE0301300,and 2017YFE0301506)Fujian Province Industrial Guidance Project(No.2019H0011).
文摘The self-absorption effect is one of the main factors affecting the quantitative analysis accuracy of laser-induced breakdown spectroscopy.In this paper,the self-absorption effects of laserinduced 7050 Al alloy plasma under different pressures in air,Ar,and N2have been studied.Compared with air and N2,Ar significantly enhances the spectral signal.Furthermore,the spectral self-absorption coefficient is calculated to quantify the degree of self-absorption,and the influences of gas species and gas pressure on self-absorption are analyzed.In addition,it is found that the spectral intensity fluctuates with the change of pressure of three gases.It can also be seen that the fluctuation of spectral intensity with pressure is eliminated after correcting,which indicates that the self-absorption leads to the fluctuation of spectral intensity under different pressures.The analysis shows that the evolution of optical thin spectral lines with pressure in different gases is mainly determined by the gas properties and the competition between plasma confinement and Rayleigh–Taylor instability.
基金financial support from the Scientific Research Program for Young Talents of China National Nuclear Corporation(2020)National Natural Science Foundation of China(Nos.51906124 and 62205172)+1 种基金Shanxi Province Science and Technology Department(No.20201101013)Guoneng Bengbu Power Generation Co.,Ltd(No.20212000001)。
文摘Severe matrix effects and high signal uncertainty are two key bottlenecks for the quantitative performance and wide applications of laser-induced breakdown spectroscopy(LIBS).Based on the understanding that the superposition of both matrix effects and signal uncertainty directly affects plasma parameters and further influences spectral intensity and LIBS quantification performance,a data selection method based on plasma temperature matching(DSPTM)was proposed to reduce both matrix effects and signal uncertainty.By selecting spectra with smaller plasma temperature differences for all samples,the proposed method was able to build up the quantification model to rely more on spectra with smaller matrix effects and signal uncertainty,therefore improving final quantification performance.When applied to quantitative analysis of the zinc content in brass alloys,it was found that both accuracy and precision were improved using either a univariate model or multiple linear regression(MLR).More specifically,for the univariate model,the root-mean-square error of prediction(RMSEP),the determination coefficients(R^(2))and relative standard derivation(RSD)were improved from 3.30%,0.864 and 18.8%to 1.06%,0.986 and 13.5%,respectively;while for MLR,RMSEP,R^(2)and RSD were improved from 3.22%,0.871 and 26.2%to 1.07%,0.986 and 17.4%,respectively.These results prove that DSPTM can be used as an effective method to reduce matrix effects and improve repeatability by selecting reliable data.
基金funded by the Ministry of Education,Science and Technological Development of the Republic of Serbia(Nos.451-03-68/2022-14/200017 and 451-03-68/2022-14/200146)the financial support of the State Committee on Science and Technology of the Republic of Belarusthe Belarusian Republican Foundation for Fundamental Research(No.F20SRBG-001)。
文摘Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based polymer that is,among other things,interesting as a substrate for laser-induced breakdown spectroscopy analysis of liquid samples.This study aimed to determine the optimal experimental conditions for obtaining neutral and ionized C spectral lines and C2 and CN molecular band emission suitable for spectrochemical purposes.Evaluation of plasma parameters was done using several spectroscopic techniques.Stark profiles of appropriate C ionic lines were used to determine electron number density.The ratio of the integral intensity of ionic-to-atomic C spectral lines was used to determine the ionization temperature.A spectral emission of C2 Swan and CN violet bands system was used to determine the temperature of the colder,peripheral parts of plasma.We critically analyzed the use of molecular emission bands as a tool for plasma diagnostics and suggested methods for possible improvements.
基金Project supported by the Science and Technology Innovation Foundation of the Chinese Academy of Sciences(Grant No.CXJJ-20S020)。
文摘When a high energy nanosecond(ns)laser induces breakdown in the air,the plasma density generated in the rarefied atmosphere is much smaller than that at normal pressure.It is associated with a relatively lower absorption coefficient and reduces energy loss of the laser beam at low pressure.In this paper,the general transmission characterizations of a Joule level 10 ns 1064 nm focused laser beam are investigated both theoretically and experimentally under different pressures.The evolution of the electron density(n_(e)),the changes in electron temperature(T_(e))and the variation of laser intensity(I)are employed for numerical analyses in the simulation model.For experiments,four optical image transfer systems with focal length(f)of 200 mm are placed in a chamber and employed to focus the laser beam and produce plasmas at the focus.The results suggest that the transmittance increases obviously with the decreasing pressure and the plasma channels on the transmission path can be observed by the self-illumination.The simulation results agree well with the experimental data.The numerical model presents that the maximum n_e at the focus can reach 10^(19)cm^(-3),which is far below the critical density(n_(c)).As a result,the laser beam is not completely shielded by the plasmas.
基金financially supported by National Natural Science Foundation of China(No.12064029)by Jiangxi Provincial Natural Science Foundation(No.20202BABL202024)by the Open project program of Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province(No.ED202208094)。
文摘Laser-induced breakdown spectroscopy(LIBS)has been used for soil analysis,but its measurement accuracy is often influenced by matrix effects of different kinds of soils.In this work,a method for matrix effect suppressing was developed using laser-induced plasma acoustic signals to correct the original spectrum,thereby improving the analysis accuracy of the soil elements.A good linear relationship was investigated firstly between the original spectral intensity and the acoustic signals.The relative standard deviations(RSDs)of Mg,Ca,Sr,and Ba elements were then calculated for both the original spectrum and the spectrum with the acoustic correction,and the RSDs were significantly reduced with the acoustic correction.Finally,calibration curves of MgⅠ285.213 nm,CaⅠ422.673 nm,SrⅠ460.733 nm and BaⅡ455.403 nm were established to assess the analytical performance of the proposed acoustic correction method.The values of the determination coefficient(R~2)of the calibration curves for Mg,Ca,Sr,and Ba elements,corrected by the acoustic amplitude,are improved from 0.9845,0.9588,0.6165,and 0.6490 to 0.9876,0.9677,0.8768,and 0.8209,respectively.The values of R~2 of the calibration curves corrected by the acoustic energy are further improved to 0.9917,0.9827,0.8835,and 0.8694,respectively.These results suggest that the matrix effect of LIBS on soils can be clearly improved by using acoustic correction,and acoustic energy correction works more efficiently than acoustic amplitude correction.This work provides a simple and efficient method for correcting matrix effects in the element analysis of soils by acoustic signals.
基金supported by the National Key Research and Development Program of China(No.2019YFD0901701)National Natural Science Foundation of China(Nos.12174359and 61975190)Provincial Key Research and Development Program of Shandong,China(No.2019GHZ010)。
文摘The quantitative determination of heavy metals in aquatic products is of great importance for food security issues.Laser-induced breakdown spectroscopy(LIBS)has been used in a variety of foodstuff analysis,but is still limited by its low sensitivity when targeting trace heavy metals.In this work,we compare three sample enrichment methods,namely drying,carbonization,and ashing,for increasing detection sensitivity by LIBS analysis for Pb and Cr in oyster samples.The results demonstrate that carbonization can remove a significant amount of the contributions of organic elements C,H,N and O;meanwhile,the signals of the metallic elements such as Cu,Pb,Sr,Ca,Cr and Mg are enhanced by3–6 times after carbonization,and further enhanced by 5–9 times after ashing.Such enhancement is not only due to the more concentrated metallic elements in the sample compared to the dried ones,but also the unifying of the matter in carbonized and ashed samples from which higher plasma temperature and electron density are observed.This condition favors the detection of trace elements.According to the calibration curves with univariate and multivariate analysis,the ashing method is considered to be the best choice.The limits of detection of the ashing method are 0.52 mg kg-1 for Pb and0.08 mg kg-1 for Cr,which can detect the presence of heavy metals in the oysters exceeding the maximum limits of Pb and Cr required by the Chinese national standard.This method provides a promising application for the heavy metal contamination monitoring in the aquatic product industry.
基金Supported by the FRGS under Grant No R.J130000.7809.4F519
文摘The laser induced plasma dynamics of graphite material are investigated by optical emission spectroscopy. Abla- tion and excitation of the graphite material is performed by using an 1064nm Nd:YAG laser in different ambient pressures. Characteristics of graphite spectra as line intensity variations and signal-to-noise ratio are presented with a main focus on the influence of the ambient pressure on the interaction of laser-induced graphite plasma with an ambient environment. Atomic emission lines are utilized to investigate the dynamical behavior of plasma, such as the excitation temperature and electron density, to describe emission differences under different ambient conditions. The excitation temperature and plasma electron density are the primary factors which contribute to the differences among the atomic carbon emission at different ambient pressures. Reactions between the plasma species and ambient gas, and the total molecular number are the main factors influencing molecular carbon emis- sion. The influence of laser energy on the plasma interaction with environment is also investigated to demonstrate the dynamical behavior of carbon species so that it can be utilized to optimize plasma fluctuations.
基金National Natural Science Foundation of China (Nos. 11674128, and 11674124)Jilin Province Scientific and Technological Development Program, China (No. 20170101063JC).
文摘The combination of spark discharge and laser-induced breakdown spectroscopy (LIBS) is called spark discharge assisted LIBS.It works under laser-plasma triggered spark discharge mode,and shows its ability to enhance spectral emission intensity.This work uses a femtosecond laser as the light souuce,since femtosecond laser has many advantages in laser-induced plasma compared with nanosecond laser,meanwhile,the study on femtosecond LIBS with spark discharge is rare.Time-resolved spectroscopy of spark discharge assisted femtosecond LIBS was investigated under different discharge voltages and laser energies.The results showed that the spectral intensity was significantly enhanced by using spark discharge compared with LIBS alone.And,the spectral emission intensity using spark discharge assisted LIBS increased with the increase in the laser energy.In addition,at low laser energy,there was an obvious delay on the discharge time compared with high laser energy,and the discharge time with positive voltage was different from that with negative voltage.
文摘Laser-induced steel plasma is generated by focusing a Q-switched Nd:YAG visible laser(532 nm wavelength) with an irradiance of 1 x 109 W/cm2 on a steel sample in air at atmospheric pressure.An Echelle spectrograph coupled with a gateable intensified charge-coupled detector is used to record the plasma emissions.Using time-resolved spectroscopic measurements of the plasma emissions,the temperature and electron number density of the steel plasma are determined for many times of the detector delay.The validity of the assumption by the spectroscopic methods that the laser-induced plasma(LIP) is optically thin and is also in local thermodynamic equilibrium(LTE) has been evaluated for many delay times.From the temporal evolution of the intensity ratio of two Fe I lines and matching it with its theoretical value,the delay times where the plasma is optically thin and is also in LTE are found to be 800 ns,900 ns and 1000 ns.
基金support of National Natural Science Foundation of China(Nos.11674128,11674124 and 11974138)the Scientific and Technological Research Project of the Education Department of Jilin Province,China(No.JJKH20200937KJ)。
文摘In this paper,we investigate the time-resolved spectroscopy of collinear femtosecond(fs)and nanosecond(ns)dual-pulse(DP)laser-induced plasmas.A copper target was used as an experimental sample,and the fs laser was considered as the time zero reference point.The interpulse delay between fs and ns laser beams was 3μs.First,we compared the time-resolved peak intensities of Cu(I)lines from Cu plasmas induced by fs+ns and ns+fs DP lasers with collinear configuration.The results showed that compared with the ns+fs DP,the fs+ns DP laser-induced Cu plasmas had stronger peak intensities and longer lifetimes.Second,we calculated time-resolved plasma temperatures using the Boltzmann plot with three spectral lines at Cu(I)510.55,515.32 and 521.82 nm.In addition,time-resolved electron densities were calculated based on Stark broadening with Cu(I)line at 521.82 nm.It was found that compared with ns+fs DP,the plasma temperatures and electron densities of the Cu plasmas induced by fs+ns DP laser were higher.Finally,we observed images of ablation craters under the two experimental conditions and found that the fs+ns DP laser-produced stronger ablation,which corresponded to stronger plasma emission.
基金the Foundation Research Project of Jiangsu Province,China(the Natural Science Fund No.BK20190187)。
文摘Laser-induced plasmas of dual-pulse fiber-optic laser-induced breakdown spectroscopy with different pulse energy ratios are studied by using the optical emission spectroscopy(OES)and fast imaging.The energy of the two laser pulses is independently adjusted within 0–30 m J with the total energy fixed at 30 m J.The inter-pulse delay remains 450 ns constantly.As the energy share of the first pulse increases,a similar bimodal variation trend of line intensities is observed.The two peaks are obtained at the point where the first pulse is half or twice of the second one,and the maximum spectral enhancement is at the first peak.The bimodal variation trend is induced by the change in the dominated mechanism of dual-pulse excitation with the trough between the two peaks caused by the weak coupling between the two mechanisms.By increasing the first pulse energy,there is a transition from the ablation enhancement dominance near the first peak to the plasma reheating dominance near the second peak.The calculations of plasma temperature and electron number density are consistent with the bimodal trend,which have the values of 17024.47 K,2.75×10^(17)cm;and 12215.93 K,1.17×10^(17)cm;at a time delay of 550 ns.In addition,the difference between the two peaks decreases with time delay.With the increase in the first pulse energy share,the plasma morphology undergoes a transformation from hemispherical to shiny-dot and to oblate-cylinder structure during the second laser irradiation from the recorded images by using an intensified charge-coupled device(ICCD)camera.Correspondingly,the peak expansion distance of the plasma front first decreases significantly from 1.99 mm in the single-pulse case to 1.34 mm at 12/18(dominated by ablation enhancement)and then increases slightly with increasing the plasma reheating effect.The variations in plasma dynamics verify that the change of pulse energy ratios leads to a transformation in the dual-pulse excitation mechanism.
文摘For the first time, absolute densities of atomic nitrogen in its ground state (N4S) have been measured in hot dry and humid air plasma columns under post-discharge regime. The determination of space-resolved absolute densities leads to obtain the dissociation degrees of molecular nitrogen in the plasma. The hot plasmas are generated inside an upstream gas-conditioning cell at 600 mbar when the air gas flow is directly injected at 10 slm in a microwave resonant cavity (2.45 GHz, 1 kW) placed in the downstream side. Density measurements based on laser induced fluorescence spectroscopy with two-photon excitation (TALIF), are more particularly performed along the radial and axial positions of the plasma column. Calibration of TALIF signals is performed in situ (i.e. in the same gas-conditioning cell but without plasma) using an air gas mixture containing krypton. Optical emission spectroscopy is considered to estimate the rotational gas temperature by adding a small amount of H2 in dry air to better detect OH (A-X) spectra. The rotational temperatures in humid air plasma column (50% of humidity) are larger than those of dry air plasma column by practically 30% near the nozzle of resonant cavity on the axis of the plasma column. This is partly due to attachment heating processes initiated by water vapor. A maximum of the measured absolute nitrogen density is also observed near the nozzle which is also larger for humid air plasma column. The obtained dissociation degrees of molecular nitrogen in both dry and humid air plasma along the air plasma column are lower than the cases where only thermodynamic equilibrium is assumed. This is characteristic of the absence of chemical and energetic equilibria not yet reached in the air plasma column dominated by recombination processes.
基金financially supported by National Natural Science Foundation of China(No.62005078)the Scientific Research Foundation of Hunan Provincial Education Department(No.21B0477)the Natural Science Foundation of Hunan Province(No.2020JJ5206)。
文摘The detection of manganese(Mn)in steel by laser-induced breakdown spectroscopy(LIBS)provides essential information for steelmaking.However,self-absorption greatly disrupts the LIBS spectral lines of Mn with high content.In this study,to minimize self-absorption for Mn spectral lines in LIBS,laser-induced fluorescence(LIF)was applied.Compared with conventional LIBS,the self-absorption factors(α)of Mn I 403.08,403.31,and 403.45 nm lines were reduced by 90%,88%,and 88%,respectively;the root mean square errors of crossvalidation were decreased by 88%,85%,and 87%,respectively;the average relative errors were reduced by 93%,90%,and 91%,respectively;and average relative standard deviations were decreased by 29%,32%,and 33%,respectively.The LIBS-LIF was shown to successfully minimize the self-absorption effect and spectral intensity fluctuation and improve detection accuracy.
基金supported by the Russian Science Foundation(agreement#14-50-00034)(measurements of limit of detection)Russian Foundation for Basic Research(NK 15-32-20878/15)obtained in the frame of "Organization of Scientific Research"in the Far Eastern Federal University supported by Ministry of Education and Science of Russian Federation
文摘The influence of the energy of femtosecond laser pulses on the intensity of Fe I (371.99 nm) emission line and the continuous spectrum of the plasma generated on the surface of Fe^3+ water solution by a Ti: sapphire laser radiation with pulse duration 〈45 fs and energies up to 7 mJ is determined. A calibration curve was obtained for Fe3+ concentration range from 0.5 g/L to the limit of detection in water solution, and its saturation was detected for concentrations above 0.25 g/L, which is ascribed to self-absorption. The 3σ- limit of detection obtained for Fe in water solution is 2.6 mg/L in the case of 7 mJ laser pulse energy. It is found that an increase of laser pulse energy insignificantly affects on LOD in the time-resolved LIBS and leads to a slight improvement of the limit of detection.