Hydrodynamics characterization in terms offlow regime behavior is a crucial task to enhance the design of bubble column reactors and scaling up related methodologies.This review presents recent studies on the typicalflo...Hydrodynamics characterization in terms offlow regime behavior is a crucial task to enhance the design of bubble column reactors and scaling up related methodologies.This review presents recent studies on the typicalflow regimes established in bubble columns.Some effort is also provided to introduce relevant definitions pertaining to thisfield,namely,that of“void fraction”and related(local,chordal,cross-sectional and volumetric)variants.Experimental studies involving different parameters that affect design and operating conditions are also discussed in detail.In the second part of the review,the attention is shifted to cases with internals of various types(perfo-rated plates,baffles,vibrating helical springs,mixers,and heat exchanger tubes)immersed in the bubble columns.It is shown that the presence of these elements has a limited influence on the global column hydrodynamics.However,they can make the homogeneousflow regime more stable in terms of transition gas velocity and transi-tion holdup value.The last section is used to highlight gaps which have not beenfilled yet and future directions of investigation.展开更多
The addition of dispersed-phase nanoparticles in the liquid phase can enhance the gas-liquid transfer process as the suspended nanoparticles affect the transfer process inside the fluid through microdisturbance or mic...The addition of dispersed-phase nanoparticles in the liquid phase can enhance the gas-liquid transfer process as the suspended nanoparticles affect the transfer process inside the fluid through microdisturbance or micro-convection effects.In this article,a high-speed digital camera was used to visualize the bubble behavior of CO_(2) in pure water and nanofluids to examine the effects of CO_(2) gas flow rate,nanoparticle solid content and type on the bubble behavior in the fluids.The CO_(2) absorption performance in three water-based nanofluids were compared in a bubbler.And the mass transfer characteristics during CO_(2) bubble absorption and the reasons for the enhanced gas-liquid mass transfer effect of nanoparticles were analyzed.The results showed that the presence of nanoparticles affected the formation process of bubbles in the fluid,shortened the bubble detachment time,reduced the detachment diameter,effectively increased the gas-liquid contact area,and improved the bubbles detachment frequency.The system with MCM-41 corresponded to a higher overall mass transfer coefficient.Uncalined MCM-41 contained surfactant that enhanced foaming behavior in water.This prevented the transfer of CO_(2) to some extent,and the CO_(2) absorption by uncalined MCM-41/H_(2)O was 5.34%higher than that by pure water.Compared with SiO_(2) nanoparticles with the same particle size and the same composition,MCM-41 had a higher adsorption capacity and better hydrophilicity due to its larger specific surface area and rich porous structure,which was more favorable to accelerate the collision between nanoparticles and CO_(2) bubbles to cause micro-convection.Under the condition of 0.1%(mass)solid content,the enhancement of CO_(2) absorption process by MCM-41 nanoparticles was more significant and improved by 16.9%compared with pure water.展开更多
Pitting corrosion is harmful during bridge construction,which will lead to uneven roughness of steel surfaces and reduce the thickness of steel.Hence,the effect of pitting corrosion on the mechanical properties of col...Pitting corrosion is harmful during bridge construction,which will lead to uneven roughness of steel surfaces and reduce the thickness of steel.Hence,the effect of pitting corrosion on the mechanical properties of cold-formed thin-walled steel stub columns is studied,and the empirical formulas are established through regression fitting to predict the ultimate load of web and flange under pitting corrosion.In detail,the failure modes and load-displacement curves of specimens with different locations,area ratios,and depths are obtained through a large number of non-linear finite element analysis.As for the specimens with pitting corrosion on the web,all the specimens are subject to local buckling failure,and the failure mode will not change with pitting corrosion,but the failure location will change with pitting corrosion location;the size,location,and area ratio of pitting corrosion have little influence on the ultimate load of cold-formed thin-walled steel short columns,but the loss rate of pitting corrosion section area has a greater impact on the ultimate bearing capacity.As for the specimen with flange pitting corrosion,the location and area ratio of pitting corrosion have less influence on the ultimate load of cold-formed thin-walled steel short columns,and the section area loss rate has greater influence on the ultimate bearing capacity;the impact of web pitting corrosion on the ultimate load is greater than that of flange pitting corrosion under the same condition of pitting corrosion section area.The prediction formulas of limit load which are suitable for pitting corrosion of web and flange are established,which can provide a reference for performance evaluation of corroded cold-formed thin-walled steel.展开更多
This manuscript presents a dataset detailing a method for purifying monomers. Purification plays a crucial role in every chemical process, as it leads to an improvement in product quality through the removal of impuri...This manuscript presents a dataset detailing a method for purifying monomers. Purification plays a crucial role in every chemical process, as it leads to an improvement in product quality through the removal of impurities. The primary method for monomer purification, like acrylonitrile (AN), is the distillation technique. However, this technique is unsafe and hard to set up or handle. A straightforward, risk-free, low-cost method like the column technique resolves these issues. A simple column technique demonstrated the successful execution of purifying AN. Fourier transform infrared (FTIR) and nuclear magnetic resonance (NMR) analyses confirmed that AN was successfully purified, with purity reaching 99.8%. FTIR spectra revealed changes in the position and intensity of the stretching vibration peaks after purification. Also, the functional groups of the inhibitor monomethyl ether of hydroquinone (MeHQ) were undetected after purification. Furthermore, after purification, NMR spectra revealed the absence of aromatic protons and carbons associated with MeHQ. In conclusion, the column technique is a successful and inexpensive way to purify AN monomers. This makes it useful for a wide range of applications, especially in polymerization reactions where MeHQ needs to be removed to prevent self-polymerization during the initiation process.展开更多
In this study,an optimization method is proposed to enhance the gas–liquid mass transfer in bubble column reactor based on the entropy generation extremum principle.The mass transfer–induced entropy generation can b...In this study,an optimization method is proposed to enhance the gas–liquid mass transfer in bubble column reactor based on the entropy generation extremum principle.The mass transfer–induced entropy generation can be maximized with the increase of mass transfer rate,based on which the velocity field can be optimized.The oxygen gas–liquid mass transfer is the major rate–limiting step of the toluene emissions biodegradation process in bubble column reactor,so the entropy generation due to oxygen mass transfer is used as the objective function,and the conservation equations of the gas–liquid flow and species concentration are taken as constraints.This optimization problem is solved by the calculus of variations,the optimal liquid flow pattern is obtained and the relationship of the maximum mass transfer enhancement on viscous dissipation is revealed,which can be used to improve the design of internal structure of the bubble column reactor.展开更多
Continuous soil-cement wall confinement method to resist liquefaction is a new kind of process. However, whether it also has a good effect on anti-liquefaction or not needs to be urgently answered for earthquake engin...Continuous soil-cement wall confinement method to resist liquefaction is a new kind of process. However, whether it also has a good effect on anti-liquefaction or not needs to be urgently answered for earthquake engineering. Quiet boundary is adopted on the lateral face while free field boundary is employed at the bottom. Byrne model on dynamic pore water pressure generation is accepted and natural seismic wave EI Centro whose peak acceleration is adjusted to 0.2 g in proportion is used for input. A double-layer foundation with sandy soil in the upper portion while clay soil in the lower part is chosen as the calculation model, which is 30 m in length and 20 m in width. The groundwater level is on the ground surface. Excess pore water pressure rate is considered as a liquefaction index in the three-dimensional non-linear earthquake response computation. The anti-liquefaction effectiveness and its influencing factors, such as confinement element area are studied. For the natural double-layer foundation, it is liquefied when the excess pore water pressure rate reaches 1.0 under the seismic load. Under the same earthquake load, the peak excess pore water pressure reduces to 0.56 after adopting reinforcement of the continuous soil-cement wall, which is 46% lower than before. It indicates that continuous soil-cement wall confinement method can attain the purpose of anti-liquefaction. Accordingly, it can be a sort of engineering measure to carry on the anti-liquefaction foundation treatment.展开更多
As a traditional herbal medicine,the major alkaloids in Uncaria rhynchophylla have been proven to have blood pressure-lowering and sedative effects.It is essential to develop an effective method for the determination ...As a traditional herbal medicine,the major alkaloids in Uncaria rhynchophylla have been proven to have blood pressure-lowering and sedative effects.It is essential to develop an effective method for the determination of the major alkaloids in U.rhynchophylla.In this research,a rapid quantitative analysis involving multi-components analysis by a single marker strategy coupled with core-shell column HPLC was adopted to analyse four alkaloids(corynoxeine,isocorynoxeine,isorhynchophylline,rhynchophylline)in U.rhynchophylla.Isorhynchophylline was selected as the internal reference substance,the content of which was determined by the traditional external standard method.Relative correction factors(RCF)between isorhynchophylline and the other three alkaloids were calculated respectively.The results showed that the QAMS method had good robustness under different HPLC instruments.Nineteen batches of U.rhynchophylla were tested.No significant difference was observed between the results by QAMS and EMS(Correlation coefficient>0.99,p>0.05).The QAMS method could be employed as a rapid,effective technique for the quality control of U.rhynchophylla.展开更多
The selective aerobic oxidation of benzyl alcohol to benzaldehyde has attracted considerable attention because benzaldehyde is a high value-added product. The rate of this typical gas–liquid reaction is significantly...The selective aerobic oxidation of benzyl alcohol to benzaldehyde has attracted considerable attention because benzaldehyde is a high value-added product. The rate of this typical gas–liquid reaction is significantly affected by mass transfer. In this study, CoTPP-mediated(CoTPP: cobalt(II) mesotetraphenylporphyrin) selective benzyl alcohol oxidation with oxygen was conducted in a membrane microchannel(MMC) reactor and a bubble column(BC) reactor, respectively. We observed that 83% benzyl alcohol was converted within 6.5 min in the MMC reactor, but only less than 10% benzyl alcohol was converted in the BC reactor. Hydrodynamic characteristics and gas–liquid mass transfer performances were compared for the MMC and BC reactors. The MMC reactor was assumed to be a plug flow reactor,and the dimensionless variance was 0.29. Compared to the BC reactor, the gas–liquid mass transfer was intensified significantly in MMC reactor. It could be ascribed to the high gas holdup(2.9 times higher than that of BC reactor), liquid film mass transfer coefficient(8.2 times higher than that of BC reactor), and mass transfer coefficient per unit interfacial area(3.8 times higher than that of BC reactor). Moreover,the Hatta number for the MMC reactor reached up to 0.61, which was about 15 times higher than that of the BC reactor. The computational fluid dynamics calculations for mass fractions in both liquid and gas phases were consistent with the experimental data.展开更多
To implement the performance-based seismic design of engineered structures,the failure modes of members must be classified.The classification method of column failure modes is analyzed using data from the Pacific Eart...To implement the performance-based seismic design of engineered structures,the failure modes of members must be classified.The classification method of column failure modes is analyzed using data from the Pacific Earthquake Engineering Research Center(PEER).The main factors affecting failure modes of columns include the hoop ratios,longitudinal reinforcement ratios,ratios of transverse reinforcement spacing to section depth,aspect ratios,axial compression ratios,and flexure-shear ratios.This study proposes a data-driven prediction model based on an artificial neural network(ANN)to identify the column failure modes.In this study,111 groups of data are used,out of which 89 are used as training data and 22 are used as test data,and the ANN prediction model of failure modes is developed.The results show that the proposed method based on ANN is superior to traditional methods in identifying the column failure modes.展开更多
In this paper,an improved computational fluid dynamic(CFD)model for gas-liquid flow in bubble column was developed using the one-equation Wary-Agarwal(WA)turbulence model coupled with the population balance model(PBM)...In this paper,an improved computational fluid dynamic(CFD)model for gas-liquid flow in bubble column was developed using the one-equation Wary-Agarwal(WA)turbulence model coupled with the population balance model(PBM).Through 18 orthogonal test cases,the optimal combination of interfacial force models,including drag force,lift force,turbulent dispersion force.The modified wall lubrication force model was proposed to improve the predictive ability for hydrodynamic behavior near the wall of the bubble column.The values simulated by optimized CFD model were in agreement with experimental data,and the errors were within±20%.In addition,the axial velocity,turbulent kinetic energy,bubble size distribution,and the dynamic characteristic of bubble plume were analyzed at different superficial gas velocities.This research work could provide a theoretical basis for the extension of the CFD-PBM coupled model to other multiphase reactors..展开更多
Packed columns are widely used in the chemical industry such as absorption,stripping,distillation,and extraction in the production of e.g.organic chemicals,and pharmaceuticals.Pressure loss and pressure drop correlati...Packed columns are widely used in the chemical industry such as absorption,stripping,distillation,and extraction in the production of e.g.organic chemicals,and pharmaceuticals.Pressure loss and pressure drop correlations are of special interest when it comes to the hydrodynamic properties of a column.The pressure loss across the column is of interest in the design phase when the size of the blower to drive the gas stream through the column has to be decided.The loading point and flooding point are also influenced by the pressure loss and the area of operation is determined from these points.This work examines four different correlations on pressure drop.The correlations are(i)Ergun’s equation(1952),(ii)an improved version of Ergun’s equation by Stichlmair,Bravo,and Fair(1989),(iii)an equation developed by Billet and Schultes(1999),and(iv)an equation by Rocha,Bravo,and Fair(1993).The complexity of the correlations is increasing in the mentioned order,Ergun’s equation being the simplest one.This study investigates if the more complicated correlations give better predictions to pressure drop in packed columns.This is determined by comparing the correlations to experimental data for pressure drop in a packed column with 8.2 m of structured packing using water as the liquid and atmospheric air as the gas.Seven experiments were carried out for determining the pressure drop in the column with liquid flows varying from 0 to 500 kg·h^(-1).At constant liquid flow,the gas flow was varied from approximately 10 to 70 kg·h^(-1).The pressure drop across the non-wetted column was best described by the correlation by Rocha et al.while the pressure drop for liquid flows from 100 to 500 kg·h^(-1)was,in general,best described by Stichlmair’s equation.For an irrigated column,the highest deviation was a predicted pressure drop 69.6%lower than measured.The best prediction was 0.1%higher than the measured.This study shows,surprisingly,that for a system of water and atmospheric air,complicated correlations on pressure drop determination do not provide better estimates than simple equations.展开更多
Cold seeps are widely developed on the seabed of continental margins and can form gas plumes due to the upward migration of methane-rich fluids.The detection and automatic segmentation of gas plumes are of great signi...Cold seeps are widely developed on the seabed of continental margins and can form gas plumes due to the upward migration of methane-rich fluids.The detection and automatic segmentation of gas plumes are of great significance in locating and studying the cold seep system that is usually accompanied by hydrate layers in the subsurface.A multibeam echo-sounder system(MBES)can record the complete backscatter intensity of the water column,and it is one of the most effective means for detecting cold seeps.However,the gas plumes recorded in multibeam water column images(WCI)are usually blurred due to the interference of the complicated water environment and the sidelobes of the MBES,making it difficult to obtain the effective segmentation.Therefore,based on the existing UNet semantic segmentation network,this paper proposes an AP-UNet network combining the convolutional block attention module and the pyramid pooling module for the automatic segmentation and extraction of gas plumes.Comparative experiments are conducted among three traditional segmentation methods and two deep learning methods.The results show that the AP-UNet segmentation model can effectively suppress complicated water column noise interference.The segmentation precision,the Dice coefficient,and the recall rate of this model are 92.09%,92.00%,and 92.49%,respectively,which are 1.17%,2.10%,and 2.07%higher than the results of the UNet.展开更多
The intention of this fundamental work is to explore the manipulation of a mixture of benzene,toluene and o-xylene separated from liquid-only transfer divided-wall column(LTS-DWC).First,two control structures are clea...The intention of this fundamental work is to explore the manipulation of a mixture of benzene,toluene and o-xylene separated from liquid-only transfer divided-wall column(LTS-DWC).First,two control structures are clearly proposed,including seven component control loops(CS1)and seven temperature control loops(CS2).However,two control structures can handle ±10% feed disturbances rather than larger feed disturbances.Subsequently,an equivalent four-column model by introducing withdraw ratio is developed to discuss the effect of two liquid-only side-stream on the overall reboiler duty.It is indicated that the second liquid-only side-stream withdraw ratio strongly affects the overall energy consumption.Hence,six-component control loops within the fixed second liquid-only side-stream withdraw ratio(CS3)is proposed and the purity of products returns to set value even as facing ±20% feed disturbances.Finally,based on the above results,it is established a temperature control structure(CS4)for controlling fixed second liquid-only side-stream withdraw ratio,which can cope with ±15% disturbances.Inspired by these findings,an insight into the dynamic control of LTS-DWC promotes the industrial implementation of DWC through new liquid-only side-stream configurations.展开更多
Fixed-bed operating experimental column conditions were studied to evaluate the performance of brick from Bangui Region (in Central African Republic), coated with iron oxyhydroxide (ferrihydrite) for the removal of ir...Fixed-bed operating experimental column conditions were studied to evaluate the performance of brick from Bangui Region (in Central African Republic), coated with iron oxyhydroxide (ferrihydrite) for the removal of iron(II) from aqueous solution. The prediction of theoretical breakthrough profiles using Bohart and Adams sorption model was employed to achieve characteristic parameters such as depth of exchange zone, time required for exchange zone to move vertically, moving rate for the exchange zone and adsorption capacity useful for fixed-bed column reactor was investigated under varying operating conditions. The effects of bed depth and flow rate on iron(II) adsorption were studied. Our finding revealed that the Brick from Bangui Region (in Central African Republic), coated with ferrihydrite was a very efficient media for the removal of Fe(II) ions from water. The experimental data showed that the depth and the moving rate (10.3 ± 0.6 cm) and (0.208 ± 0.006 cm/min) respectively of the exchange zone (adsorption zone) were independent of variability of the height of the adsorbent bed column, however the variations of the flow rate affect the moving rate of the exchange zone. The bed depth service time (BDST) model was used and permitted us to predict the service times of columns operated at various flow rates and bed depths and these predicted values were compared with the experimental values.展开更多
The constant bubble size modeling approach(CBSM)and variable bubble size modeling approach(VBSM)are frequently employed in Eulerian–Eulerian simulation of bubble columns.However,the accuracy of CBSM is limited while ...The constant bubble size modeling approach(CBSM)and variable bubble size modeling approach(VBSM)are frequently employed in Eulerian–Eulerian simulation of bubble columns.However,the accuracy of CBSM is limited while the computational efficiency of VBSM needs to be improved.This work aims to develop method for bubble size modeling which has high computational efficiency and accuracy in the simulation of bubble columns.The distribution of bubble sizes is represented by a series of discrete points,and the percentage of bubbles with various sizes at gas inlet is determined by the results of computational fluid dynamics(CFD)–population balance model(PBM)simulations,whereas the influence of bubble coalescence and breakup is neglected.The simulated results of a 0.15 m diameter bubble column suggest that the developed method has high computational speed and can achieve similar accuracy as CFD–PBM modeling.Furthermore,the convergence issues caused by solving population balance equations are addressed.展开更多
Here,a styrene-based polymer monolithic column poly(VBS-co-TAT-co-AHM)with reversed-phase/hydrophilic interaction liquid chromatography(RPLC/HILIC)bifunctional separation mode was success-fully prepared for capillary ...Here,a styrene-based polymer monolithic column poly(VBS-co-TAT-co-AHM)with reversed-phase/hydrophilic interaction liquid chromatography(RPLC/HILIC)bifunctional separation mode was success-fully prepared for capillary electrochromatography by the in situ polymerization of sodium p-styrene sulfonate(VBS)with cross-linkers 3-(acryloyloxy)-2-hydroxypropyl methacrylate(AHM)and 1,3,5-triacryloylhexahydro-1,3,5-triazine(TAT).The preparation conditions of the monolith were optimized.The morphology and formation of the poly(VBS-co-TAT-co-AHM)monolith were confirmed by scanning electron microscopy(SEM)and Fourier transform infrared spectroscopy(FT-IR).The separation perfor-mances of the monolith were evaluated systematically.It should be noted that the incorporation of VBS functional monomer can provideπ-πinteractions,hydrophilic interactions,and ion-exchange in-teractions.Hence,the prepared poly(VBS-co-TAT-co-AHM)monolith can achieve efficient separation of thiourea compounds,benzene series,phenol compounds,aniline compounds and sulfonamides in RPLC or HILIC separation mode.The largest theoretical plate number for N,N0-dimethylthiourea reached 1.7×10^(5)plates/m.In addition,the poly(VBS-co-TAT-co-AHM)monolithic column showed excellent reproducibility and stability.This novel monolithic column has great application value and potential in capillary electrochromatography(CEC).展开更多
To enable rapid recovery of a steel bridge column after an earthquake,a novel tubular-section steel bridge column equipped with low-yield-point(LYP)steel tubular plates in the root replaceable pier is proposed.For the...To enable rapid recovery of a steel bridge column after an earthquake,a novel tubular-section steel bridge column equipped with low-yield-point(LYP)steel tubular plates in the root replaceable pier is proposed.For the purpose of discussing the seismic behavior of the novel steel bridge column,quasi-static tests and finite element simulation analyses of the specimens were carried out.The effects of parameters such as the axial compression ratio,eccentricity,and thickness and material strength of the tubular plate in the energy-dissipating zone are discussed.Experimental results from seven specimens that were subjected to four failure modes are presented.The damage to the quasi-static specimens is localized to the replaceable energy-dissipating pier.The seismic behavior of the novel steel bridge columns is significantly influenced by the axial compression ratio and eccentricity of specimens.Numerical results show that the high stress area of the specimens is mainly concentrated in the connection zone between the LYP steel tubular plate and the bottom steel plate,which is consistent with the position of the quasi-static specimen when it was prone to fracture.Finally,a calculation formula is proposed to facilitate the capacity prediction of this new steel tubular bridge column under repeated loading.展开更多
For dividing-wall distillation columns(DWDCs) separating a heavy-component dominated and wide boiling-point ternary(HCDWBT) mixture, a significant amount of excessive heat exists inevitably in stripping the heavy-comp...For dividing-wall distillation columns(DWDCs) separating a heavy-component dominated and wide boiling-point ternary(HCDWBT) mixture, a significant amount of excessive heat exists inevitably in stripping the heavy-component from the intermediate-component and it can be employed to initiate the development of vapor recompression heat pump(VRHP) assisted DWDC(VRHP-DWDC). Despite dividing wall may locate in the top, middle, and bottom, the optimum VRHP-DWDC is found to involve uniformlytwo VRHP circles. While the first one serves to compress and transform the excessive heat resulted from the separation of the heavy-component from the intermediate-component, the second one to compress and transform the overhead vapor stream of the light-component pre-heated sequentially with the condensate from the first one and the bottom product stream of the heavy-component, both releasing the temperature-elevated latent heat to the pre-fractionator's or common stripping section. The processing of two HCDWBT mixtures of benzene/toluene/o-xylene and n-pentane/n-hexane/n-heptane are selected to assess the derived optimum topological configurations of the VRHP-DWDC and their optimality is confirmed through detailed comparisons with the DWDC and two VRHP-DWDCs involving only one VRHP circle. The proposed strategy helps to tap the full potential of the VRHP-DWDC with considerably alleviated complication in process development.展开更多
Monte Carlo simulation of gamma photon transport and interaction with the distillation column and its contents was performed in order to predict the effects of gamma photons when they interact with matter. The results...Monte Carlo simulation of gamma photon transport and interaction with the distillation column and its contents was performed in order to predict the effects of gamma photons when they interact with matter. The results of the interaction and transport of gamma photons are presented as energy deposition on the distillation column and its contents. Energy attenuation was more pronounced on the column walls and trays as compared to the region between the trays, where there is mostly vapour space. Gamma column scanning was then used to verify the Monte Carlo simulation results by scanning and investigating the integrity of two laboratory prototype distillation and industrial distillation columns. One of the prototype distillation columns was 1 m tall with four trays and the other one was 1.8 m tall consisting of six trays and a packed bed. Commonly encountered distillation column malfunctions such as collapsed tray, weeping, flooding and foaming were simulated in the two prototype distillation columns and scanned. The industrial distillation column was a 26 m tall benzole prefractionator column, consisting of 60 single pass trays and a diameter of 0.8 m. A 10 mCi <sup>60</sup>Co gamma radiation source and NaI(Tl) scintillation detector were used to scan the distillation columns. The results from the two prototypes showed that all the simulated malfunctions were clearly detected except for foaming. The results from industrial distillation column showed that all the trays were in their correct position although tray number 32 could be partially damaged and just below tray 41, the scan revealed that there was a loss of column wall thickness. The obtained density profile for the industrial distillation column showed some small variations from the expected density profile and this was attributed to external features on the distillation column and wind bursts that shifted the source and detector from the chosen scan line orientation.展开更多
This study attempts to investigate the interaction between lower and upper atmosphere, employing daily data of Total Ozone Column (TOC) and atmospheric parameter (cloud cover) over Nigeria from 1998-2012;in order to s...This study attempts to investigate the interaction between lower and upper atmosphere, employing daily data of Total Ozone Column (TOC) and atmospheric parameter (cloud cover) over Nigeria from 1998-2012;in order to study the dynamic effect of ozone on climate and vice versa. This is due to the fact that ozone and climate influence each other and the understanding of the dynamic effect of the interconnectivity is still an open research area. Monthly mean daily TOC and cloud cover data were obtained from the Earth Probe Total Ozone Mass Spectroscopy (EPTOMS) and the International Satellite Cloud Climatology Project (ISCCP)-D2 datasets respectively. Bivariate analysis and Mann Kendall trend tests were used in data analysis. MATLAB and ArcGIS software were employed in analyzing the data. Results reveal that TOC increased spatially from the coastal region to the north eastern region of the country. Seasonally, the highest value of TOC was observed at the peak of rainy season when cloud activity is very high, while the lowest value was recorded in dry season. These variations were attributed to rain producing mechanisms and atmospheric phenomena which influence the transport and distribution of ozone. Furthermore, the statistical analysis reveals significant relationship between TOC and low and middle cloud covers in contrast to high cloud cover. This relationship is consistent with previous studies using other atmospheric variables. This study has given scientific insight which is useful in understanding the coupling of the lower and upper atmosphere.展开更多
文摘Hydrodynamics characterization in terms offlow regime behavior is a crucial task to enhance the design of bubble column reactors and scaling up related methodologies.This review presents recent studies on the typicalflow regimes established in bubble columns.Some effort is also provided to introduce relevant definitions pertaining to thisfield,namely,that of“void fraction”and related(local,chordal,cross-sectional and volumetric)variants.Experimental studies involving different parameters that affect design and operating conditions are also discussed in detail.In the second part of the review,the attention is shifted to cases with internals of various types(perfo-rated plates,baffles,vibrating helical springs,mixers,and heat exchanger tubes)immersed in the bubble columns.It is shown that the presence of these elements has a limited influence on the global column hydrodynamics.However,they can make the homogeneousflow regime more stable in terms of transition gas velocity and transi-tion holdup value.The last section is used to highlight gaps which have not beenfilled yet and future directions of investigation.
基金financial support from National Natural Science Foundation of China(22108263)Shanxi Province Basic Research Program Project(20210302124060)the 18th Graduate Student Technology Project of North University of China(20221824).
文摘The addition of dispersed-phase nanoparticles in the liquid phase can enhance the gas-liquid transfer process as the suspended nanoparticles affect the transfer process inside the fluid through microdisturbance or micro-convection effects.In this article,a high-speed digital camera was used to visualize the bubble behavior of CO_(2) in pure water and nanofluids to examine the effects of CO_(2) gas flow rate,nanoparticle solid content and type on the bubble behavior in the fluids.The CO_(2) absorption performance in three water-based nanofluids were compared in a bubbler.And the mass transfer characteristics during CO_(2) bubble absorption and the reasons for the enhanced gas-liquid mass transfer effect of nanoparticles were analyzed.The results showed that the presence of nanoparticles affected the formation process of bubbles in the fluid,shortened the bubble detachment time,reduced the detachment diameter,effectively increased the gas-liquid contact area,and improved the bubbles detachment frequency.The system with MCM-41 corresponded to a higher overall mass transfer coefficient.Uncalined MCM-41 contained surfactant that enhanced foaming behavior in water.This prevented the transfer of CO_(2) to some extent,and the CO_(2) absorption by uncalined MCM-41/H_(2)O was 5.34%higher than that by pure water.Compared with SiO_(2) nanoparticles with the same particle size and the same composition,MCM-41 had a higher adsorption capacity and better hydrophilicity due to its larger specific surface area and rich porous structure,which was more favorable to accelerate the collision between nanoparticles and CO_(2) bubbles to cause micro-convection.Under the condition of 0.1%(mass)solid content,the enhancement of CO_(2) absorption process by MCM-41 nanoparticles was more significant and improved by 16.9%compared with pure water.
基金funded by the‘Research Project of the Sucheng to Sihong Section of the Yanluo Expressway-Measurement Technology and Application of Bridge Quality Project Based on UAV Binocular Imaging(No.00-00-JSFW-20230203-029)’,received by H.Z.Wang.
文摘Pitting corrosion is harmful during bridge construction,which will lead to uneven roughness of steel surfaces and reduce the thickness of steel.Hence,the effect of pitting corrosion on the mechanical properties of cold-formed thin-walled steel stub columns is studied,and the empirical formulas are established through regression fitting to predict the ultimate load of web and flange under pitting corrosion.In detail,the failure modes and load-displacement curves of specimens with different locations,area ratios,and depths are obtained through a large number of non-linear finite element analysis.As for the specimens with pitting corrosion on the web,all the specimens are subject to local buckling failure,and the failure mode will not change with pitting corrosion,but the failure location will change with pitting corrosion location;the size,location,and area ratio of pitting corrosion have little influence on the ultimate load of cold-formed thin-walled steel short columns,but the loss rate of pitting corrosion section area has a greater impact on the ultimate bearing capacity.As for the specimen with flange pitting corrosion,the location and area ratio of pitting corrosion have less influence on the ultimate load of cold-formed thin-walled steel short columns,and the section area loss rate has greater influence on the ultimate bearing capacity;the impact of web pitting corrosion on the ultimate load is greater than that of flange pitting corrosion under the same condition of pitting corrosion section area.The prediction formulas of limit load which are suitable for pitting corrosion of web and flange are established,which can provide a reference for performance evaluation of corroded cold-formed thin-walled steel.
文摘This manuscript presents a dataset detailing a method for purifying monomers. Purification plays a crucial role in every chemical process, as it leads to an improvement in product quality through the removal of impurities. The primary method for monomer purification, like acrylonitrile (AN), is the distillation technique. However, this technique is unsafe and hard to set up or handle. A straightforward, risk-free, low-cost method like the column technique resolves these issues. A simple column technique demonstrated the successful execution of purifying AN. Fourier transform infrared (FTIR) and nuclear magnetic resonance (NMR) analyses confirmed that AN was successfully purified, with purity reaching 99.8%. FTIR spectra revealed changes in the position and intensity of the stretching vibration peaks after purification. Also, the functional groups of the inhibitor monomethyl ether of hydroquinone (MeHQ) were undetected after purification. Furthermore, after purification, NMR spectra revealed the absence of aromatic protons and carbons associated with MeHQ. In conclusion, the column technique is a successful and inexpensive way to purify AN monomers. This makes it useful for a wide range of applications, especially in polymerization reactions where MeHQ needs to be removed to prevent self-polymerization during the initiation process.
基金supported by the National Natural Science Foundation of China(91834303 and 22108261)the Open Foundation of State Key Laboratory of Chemical Engineering(SKL-ChE-19B02)+1 种基金Fundamental Research Program of Shanxi Province(20210302124618)Scientific Technological Innovation Programs of Higher Education Institution in Shanxi(2020L0284).
文摘In this study,an optimization method is proposed to enhance the gas–liquid mass transfer in bubble column reactor based on the entropy generation extremum principle.The mass transfer–induced entropy generation can be maximized with the increase of mass transfer rate,based on which the velocity field can be optimized.The oxygen gas–liquid mass transfer is the major rate–limiting step of the toluene emissions biodegradation process in bubble column reactor,so the entropy generation due to oxygen mass transfer is used as the objective function,and the conservation equations of the gas–liquid flow and species concentration are taken as constraints.This optimization problem is solved by the calculus of variations,the optimal liquid flow pattern is obtained and the relationship of the maximum mass transfer enhancement on viscous dissipation is revealed,which can be used to improve the design of internal structure of the bubble column reactor.
基金Project(50639010, 90815020) supported by the National Natural Science Foundation of ChinaProject(JKCX-200602) supported by South-to-North Water Diversion in Jiangsu Province, China
文摘Continuous soil-cement wall confinement method to resist liquefaction is a new kind of process. However, whether it also has a good effect on anti-liquefaction or not needs to be urgently answered for earthquake engineering. Quiet boundary is adopted on the lateral face while free field boundary is employed at the bottom. Byrne model on dynamic pore water pressure generation is accepted and natural seismic wave EI Centro whose peak acceleration is adjusted to 0.2 g in proportion is used for input. A double-layer foundation with sandy soil in the upper portion while clay soil in the lower part is chosen as the calculation model, which is 30 m in length and 20 m in width. The groundwater level is on the ground surface. Excess pore water pressure rate is considered as a liquefaction index in the three-dimensional non-linear earthquake response computation. The anti-liquefaction effectiveness and its influencing factors, such as confinement element area are studied. For the natural double-layer foundation, it is liquefied when the excess pore water pressure rate reaches 1.0 under the seismic load. Under the same earthquake load, the peak excess pore water pressure reduces to 0.56 after adopting reinforcement of the continuous soil-cement wall, which is 46% lower than before. It indicates that continuous soil-cement wall confinement method can attain the purpose of anti-liquefaction. Accordingly, it can be a sort of engineering measure to carry on the anti-liquefaction foundation treatment.
文摘As a traditional herbal medicine,the major alkaloids in Uncaria rhynchophylla have been proven to have blood pressure-lowering and sedative effects.It is essential to develop an effective method for the determination of the major alkaloids in U.rhynchophylla.In this research,a rapid quantitative analysis involving multi-components analysis by a single marker strategy coupled with core-shell column HPLC was adopted to analyse four alkaloids(corynoxeine,isocorynoxeine,isorhynchophylline,rhynchophylline)in U.rhynchophylla.Isorhynchophylline was selected as the internal reference substance,the content of which was determined by the traditional external standard method.Relative correction factors(RCF)between isorhynchophylline and the other three alkaloids were calculated respectively.The results showed that the QAMS method had good robustness under different HPLC instruments.Nineteen batches of U.rhynchophylla were tested.No significant difference was observed between the results by QAMS and EMS(Correlation coefficient>0.99,p>0.05).The QAMS method could be employed as a rapid,effective technique for the quality control of U.rhynchophylla.
基金financially supported by the National Key Research and Development Program of China (2020YFA0210900)the National Natural Science Foundation of China (21938001 and 21878344)+1 种基金Guangdong Provincial Key Research and Development Programme (2019B110206002)the Local Innovative and Research Teams Project of Guangdong Pearl River Talents Program (2017BT01C102)。
文摘The selective aerobic oxidation of benzyl alcohol to benzaldehyde has attracted considerable attention because benzaldehyde is a high value-added product. The rate of this typical gas–liquid reaction is significantly affected by mass transfer. In this study, CoTPP-mediated(CoTPP: cobalt(II) mesotetraphenylporphyrin) selective benzyl alcohol oxidation with oxygen was conducted in a membrane microchannel(MMC) reactor and a bubble column(BC) reactor, respectively. We observed that 83% benzyl alcohol was converted within 6.5 min in the MMC reactor, but only less than 10% benzyl alcohol was converted in the BC reactor. Hydrodynamic characteristics and gas–liquid mass transfer performances were compared for the MMC and BC reactors. The MMC reactor was assumed to be a plug flow reactor,and the dimensionless variance was 0.29. Compared to the BC reactor, the gas–liquid mass transfer was intensified significantly in MMC reactor. It could be ascribed to the high gas holdup(2.9 times higher than that of BC reactor), liquid film mass transfer coefficient(8.2 times higher than that of BC reactor), and mass transfer coefficient per unit interfacial area(3.8 times higher than that of BC reactor). Moreover,the Hatta number for the MMC reactor reached up to 0.61, which was about 15 times higher than that of the BC reactor. The computational fluid dynamics calculations for mass fractions in both liquid and gas phases were consistent with the experimental data.
基金China Energy Engineering Group Planning&Engineering Co.,Ltd.Concentrated Development Scientific Research Project Under Grant No.GSKJ2-T11-2019。
文摘To implement the performance-based seismic design of engineered structures,the failure modes of members must be classified.The classification method of column failure modes is analyzed using data from the Pacific Earthquake Engineering Research Center(PEER).The main factors affecting failure modes of columns include the hoop ratios,longitudinal reinforcement ratios,ratios of transverse reinforcement spacing to section depth,aspect ratios,axial compression ratios,and flexure-shear ratios.This study proposes a data-driven prediction model based on an artificial neural network(ANN)to identify the column failure modes.In this study,111 groups of data are used,out of which 89 are used as training data and 22 are used as test data,and the ANN prediction model of failure modes is developed.The results show that the proposed method based on ANN is superior to traditional methods in identifying the column failure modes.
基金supported by the National Natural Science Foundation of China(22078009)National Key Research and Development Program of China(2021YFC3001102,2021YFC3001100)。
文摘In this paper,an improved computational fluid dynamic(CFD)model for gas-liquid flow in bubble column was developed using the one-equation Wary-Agarwal(WA)turbulence model coupled with the population balance model(PBM).Through 18 orthogonal test cases,the optimal combination of interfacial force models,including drag force,lift force,turbulent dispersion force.The modified wall lubrication force model was proposed to improve the predictive ability for hydrodynamic behavior near the wall of the bubble column.The values simulated by optimized CFD model were in agreement with experimental data,and the errors were within±20%.In addition,the axial velocity,turbulent kinetic energy,bubble size distribution,and the dynamic characteristic of bubble plume were analyzed at different superficial gas velocities.This research work could provide a theoretical basis for the extension of the CFD-PBM coupled model to other multiphase reactors..
基金the BioCO_(2) project(the Danish government through the EUDP agency No.64016-0082)the INTERACT project(European Union Seventh Framework Programme FP7/2007-2013 under grant agreement No.608535)the financial support from the Center for Energy Resources Engineering(CERE),and the Technical University of Denmark.
文摘Packed columns are widely used in the chemical industry such as absorption,stripping,distillation,and extraction in the production of e.g.organic chemicals,and pharmaceuticals.Pressure loss and pressure drop correlations are of special interest when it comes to the hydrodynamic properties of a column.The pressure loss across the column is of interest in the design phase when the size of the blower to drive the gas stream through the column has to be decided.The loading point and flooding point are also influenced by the pressure loss and the area of operation is determined from these points.This work examines four different correlations on pressure drop.The correlations are(i)Ergun’s equation(1952),(ii)an improved version of Ergun’s equation by Stichlmair,Bravo,and Fair(1989),(iii)an equation developed by Billet and Schultes(1999),and(iv)an equation by Rocha,Bravo,and Fair(1993).The complexity of the correlations is increasing in the mentioned order,Ergun’s equation being the simplest one.This study investigates if the more complicated correlations give better predictions to pressure drop in packed columns.This is determined by comparing the correlations to experimental data for pressure drop in a packed column with 8.2 m of structured packing using water as the liquid and atmospheric air as the gas.Seven experiments were carried out for determining the pressure drop in the column with liquid flows varying from 0 to 500 kg·h^(-1).At constant liquid flow,the gas flow was varied from approximately 10 to 70 kg·h^(-1).The pressure drop across the non-wetted column was best described by the correlation by Rocha et al.while the pressure drop for liquid flows from 100 to 500 kg·h^(-1)was,in general,best described by Stichlmair’s equation.For an irrigated column,the highest deviation was a predicted pressure drop 69.6%lower than measured.The best prediction was 0.1%higher than the measured.This study shows,surprisingly,that for a system of water and atmospheric air,complicated correlations on pressure drop determination do not provide better estimates than simple equations.
基金Supported by the National Natural Science Foundation of China (Nos.41930535,41906165)the High-level Foreign Expert Introduction Program (No.G2021025006L)the SDUST Research Fund (No.2019TDJH103)。
文摘Cold seeps are widely developed on the seabed of continental margins and can form gas plumes due to the upward migration of methane-rich fluids.The detection and automatic segmentation of gas plumes are of great significance in locating and studying the cold seep system that is usually accompanied by hydrate layers in the subsurface.A multibeam echo-sounder system(MBES)can record the complete backscatter intensity of the water column,and it is one of the most effective means for detecting cold seeps.However,the gas plumes recorded in multibeam water column images(WCI)are usually blurred due to the interference of the complicated water environment and the sidelobes of the MBES,making it difficult to obtain the effective segmentation.Therefore,based on the existing UNet semantic segmentation network,this paper proposes an AP-UNet network combining the convolutional block attention module and the pyramid pooling module for the automatic segmentation and extraction of gas plumes.Comparative experiments are conducted among three traditional segmentation methods and two deep learning methods.The results show that the AP-UNet segmentation model can effectively suppress complicated water column noise interference.The segmentation precision,the Dice coefficient,and the recall rate of this model are 92.09%,92.00%,and 92.49%,respectively,which are 1.17%,2.10%,and 2.07%higher than the results of the UNet.
基金supported by National Natural Science Foundation of China(21908056)Shanghai Sailing Program(19YF1410800)Science and Technology Commission of Shanghai Municipality(19DZ2271100)。
文摘The intention of this fundamental work is to explore the manipulation of a mixture of benzene,toluene and o-xylene separated from liquid-only transfer divided-wall column(LTS-DWC).First,two control structures are clearly proposed,including seven component control loops(CS1)and seven temperature control loops(CS2).However,two control structures can handle ±10% feed disturbances rather than larger feed disturbances.Subsequently,an equivalent four-column model by introducing withdraw ratio is developed to discuss the effect of two liquid-only side-stream on the overall reboiler duty.It is indicated that the second liquid-only side-stream withdraw ratio strongly affects the overall energy consumption.Hence,six-component control loops within the fixed second liquid-only side-stream withdraw ratio(CS3)is proposed and the purity of products returns to set value even as facing ±20% feed disturbances.Finally,based on the above results,it is established a temperature control structure(CS4)for controlling fixed second liquid-only side-stream withdraw ratio,which can cope with ±15% disturbances.Inspired by these findings,an insight into the dynamic control of LTS-DWC promotes the industrial implementation of DWC through new liquid-only side-stream configurations.
文摘Fixed-bed operating experimental column conditions were studied to evaluate the performance of brick from Bangui Region (in Central African Republic), coated with iron oxyhydroxide (ferrihydrite) for the removal of iron(II) from aqueous solution. The prediction of theoretical breakthrough profiles using Bohart and Adams sorption model was employed to achieve characteristic parameters such as depth of exchange zone, time required for exchange zone to move vertically, moving rate for the exchange zone and adsorption capacity useful for fixed-bed column reactor was investigated under varying operating conditions. The effects of bed depth and flow rate on iron(II) adsorption were studied. Our finding revealed that the Brick from Bangui Region (in Central African Republic), coated with ferrihydrite was a very efficient media for the removal of Fe(II) ions from water. The experimental data showed that the depth and the moving rate (10.3 ± 0.6 cm) and (0.208 ± 0.006 cm/min) respectively of the exchange zone (adsorption zone) were independent of variability of the height of the adsorbent bed column, however the variations of the flow rate affect the moving rate of the exchange zone. The bed depth service time (BDST) model was used and permitted us to predict the service times of columns operated at various flow rates and bed depths and these predicted values were compared with the experimental values.
基金the National Natural Science Foundation of China(21625603)for supporting this work。
文摘The constant bubble size modeling approach(CBSM)and variable bubble size modeling approach(VBSM)are frequently employed in Eulerian–Eulerian simulation of bubble columns.However,the accuracy of CBSM is limited while the computational efficiency of VBSM needs to be improved.This work aims to develop method for bubble size modeling which has high computational efficiency and accuracy in the simulation of bubble columns.The distribution of bubble sizes is represented by a series of discrete points,and the percentage of bubbles with various sizes at gas inlet is determined by the results of computational fluid dynamics(CFD)–population balance model(PBM)simulations,whereas the influence of bubble coalescence and breakup is neglected.The simulated results of a 0.15 m diameter bubble column suggest that the developed method has high computational speed and can achieve similar accuracy as CFD–PBM modeling.Furthermore,the convergence issues caused by solving population balance equations are addressed.
基金the National Natural Science Foundation of China(Grant Nos.:82273885,82073808 and 81872828).
文摘Here,a styrene-based polymer monolithic column poly(VBS-co-TAT-co-AHM)with reversed-phase/hydrophilic interaction liquid chromatography(RPLC/HILIC)bifunctional separation mode was success-fully prepared for capillary electrochromatography by the in situ polymerization of sodium p-styrene sulfonate(VBS)with cross-linkers 3-(acryloyloxy)-2-hydroxypropyl methacrylate(AHM)and 1,3,5-triacryloylhexahydro-1,3,5-triazine(TAT).The preparation conditions of the monolith were optimized.The morphology and formation of the poly(VBS-co-TAT-co-AHM)monolith were confirmed by scanning electron microscopy(SEM)and Fourier transform infrared spectroscopy(FT-IR).The separation perfor-mances of the monolith were evaluated systematically.It should be noted that the incorporation of VBS functional monomer can provideπ-πinteractions,hydrophilic interactions,and ion-exchange in-teractions.Hence,the prepared poly(VBS-co-TAT-co-AHM)monolith can achieve efficient separation of thiourea compounds,benzene series,phenol compounds,aniline compounds and sulfonamides in RPLC or HILIC separation mode.The largest theoretical plate number for N,N0-dimethylthiourea reached 1.7×10^(5)plates/m.In addition,the poly(VBS-co-TAT-co-AHM)monolithic column showed excellent reproducibility and stability.This novel monolithic column has great application value and potential in capillary electrochromatography(CEC).
基金National Natural Science Foundation of China under Grant No.51778248Natural Science Foundation of Fujian Province under Grant No.2018J01075+1 种基金Education and Science Project for Young and Middle-aged Teacher of Fujian Province under Grant No.JAT200825Research Trained Fund for Outstanding Young Researcher in Higher Education Institutions of Fujian Province。
文摘To enable rapid recovery of a steel bridge column after an earthquake,a novel tubular-section steel bridge column equipped with low-yield-point(LYP)steel tubular plates in the root replaceable pier is proposed.For the purpose of discussing the seismic behavior of the novel steel bridge column,quasi-static tests and finite element simulation analyses of the specimens were carried out.The effects of parameters such as the axial compression ratio,eccentricity,and thickness and material strength of the tubular plate in the energy-dissipating zone are discussed.Experimental results from seven specimens that were subjected to four failure modes are presented.The damage to the quasi-static specimens is localized to the replaceable energy-dissipating pier.The seismic behavior of the novel steel bridge columns is significantly influenced by the axial compression ratio and eccentricity of specimens.Numerical results show that the high stress area of the specimens is mainly concentrated in the connection zone between the LYP steel tubular plate and the bottom steel plate,which is consistent with the position of the quasi-static specimen when it was prone to fracture.Finally,a calculation formula is proposed to facilitate the capacity prediction of this new steel tubular bridge column under repeated loading.
基金The financial support from National Natural Science Foundation of China (21878011)。
文摘For dividing-wall distillation columns(DWDCs) separating a heavy-component dominated and wide boiling-point ternary(HCDWBT) mixture, a significant amount of excessive heat exists inevitably in stripping the heavy-component from the intermediate-component and it can be employed to initiate the development of vapor recompression heat pump(VRHP) assisted DWDC(VRHP-DWDC). Despite dividing wall may locate in the top, middle, and bottom, the optimum VRHP-DWDC is found to involve uniformlytwo VRHP circles. While the first one serves to compress and transform the excessive heat resulted from the separation of the heavy-component from the intermediate-component, the second one to compress and transform the overhead vapor stream of the light-component pre-heated sequentially with the condensate from the first one and the bottom product stream of the heavy-component, both releasing the temperature-elevated latent heat to the pre-fractionator's or common stripping section. The processing of two HCDWBT mixtures of benzene/toluene/o-xylene and n-pentane/n-hexane/n-heptane are selected to assess the derived optimum topological configurations of the VRHP-DWDC and their optimality is confirmed through detailed comparisons with the DWDC and two VRHP-DWDCs involving only one VRHP circle. The proposed strategy helps to tap the full potential of the VRHP-DWDC with considerably alleviated complication in process development.
文摘Monte Carlo simulation of gamma photon transport and interaction with the distillation column and its contents was performed in order to predict the effects of gamma photons when they interact with matter. The results of the interaction and transport of gamma photons are presented as energy deposition on the distillation column and its contents. Energy attenuation was more pronounced on the column walls and trays as compared to the region between the trays, where there is mostly vapour space. Gamma column scanning was then used to verify the Monte Carlo simulation results by scanning and investigating the integrity of two laboratory prototype distillation and industrial distillation columns. One of the prototype distillation columns was 1 m tall with four trays and the other one was 1.8 m tall consisting of six trays and a packed bed. Commonly encountered distillation column malfunctions such as collapsed tray, weeping, flooding and foaming were simulated in the two prototype distillation columns and scanned. The industrial distillation column was a 26 m tall benzole prefractionator column, consisting of 60 single pass trays and a diameter of 0.8 m. A 10 mCi <sup>60</sup>Co gamma radiation source and NaI(Tl) scintillation detector were used to scan the distillation columns. The results from the two prototypes showed that all the simulated malfunctions were clearly detected except for foaming. The results from industrial distillation column showed that all the trays were in their correct position although tray number 32 could be partially damaged and just below tray 41, the scan revealed that there was a loss of column wall thickness. The obtained density profile for the industrial distillation column showed some small variations from the expected density profile and this was attributed to external features on the distillation column and wind bursts that shifted the source and detector from the chosen scan line orientation.
文摘This study attempts to investigate the interaction between lower and upper atmosphere, employing daily data of Total Ozone Column (TOC) and atmospheric parameter (cloud cover) over Nigeria from 1998-2012;in order to study the dynamic effect of ozone on climate and vice versa. This is due to the fact that ozone and climate influence each other and the understanding of the dynamic effect of the interconnectivity is still an open research area. Monthly mean daily TOC and cloud cover data were obtained from the Earth Probe Total Ozone Mass Spectroscopy (EPTOMS) and the International Satellite Cloud Climatology Project (ISCCP)-D2 datasets respectively. Bivariate analysis and Mann Kendall trend tests were used in data analysis. MATLAB and ArcGIS software were employed in analyzing the data. Results reveal that TOC increased spatially from the coastal region to the north eastern region of the country. Seasonally, the highest value of TOC was observed at the peak of rainy season when cloud activity is very high, while the lowest value was recorded in dry season. These variations were attributed to rain producing mechanisms and atmospheric phenomena which influence the transport and distribution of ozone. Furthermore, the statistical analysis reveals significant relationship between TOC and low and middle cloud covers in contrast to high cloud cover. This relationship is consistent with previous studies using other atmospheric variables. This study has given scientific insight which is useful in understanding the coupling of the lower and upper atmosphere.