Aim: Lead aprons are used to protect against scattered radiation from the patient during interventional procedures and certain special conventional radiological examinations. Given the importance of the role lead apro...Aim: Lead aprons are used to protect against scattered radiation from the patient during interventional procedures and certain special conventional radiological examinations. Given the importance of the role lead aprons are supposed to play in radiation protection, we propose to assess their conformity in medical imaging departments in public and religious hospitals in Togo. Materials and method: A multi-centre survey conducted from 26 November to 06 December 2021 in the radiology departments of public and religious health facilities in Togo. All aprons in use were included. The evaluation criteria were physical (visual), quantitative (radiographic) and qualitative (dosimetric). Results: We had registred 43 aprons among wich 27 (62.79%) leaded aprons were labelled non-compliant and 16 (37.21%) were labelled compliant. Of the aprons judged to be non-compliant, 70.37% were more than 10 years old and 96.30% showed defects on the radiographic images. The most common defects were vampire marks (18.64%), multiple folds (16.96%), cracks (16.96%), multiple cracks (15.25%), tears (8.47%), absence of lead (5.08%), holes (3.39%) and lead corrosion (1.69%). Defective aprons (62.96%) had at least two defects. The defects were of thoraco-abdomino-pelvic (74.07%), thoracic (14.82%) and abdomino-pelvic (11.11%) topography. For indirect exposure at 50 and 70 kilovolts, all the aprons had an attenuation factor greater than 90%. After dosimetric measurement, 13.95% of aprons had attenuation factors below 90% for indirect exposure at 100 kilovolts. Conclusion: The compliance of the leaded decks is trifactorial (physical, radiographic and dosimetric). However, there is no significant difference in X-ray attenuation capacity between defective and normal decks.展开更多
Although there are many lead-free soldering alloys on the market, none of them have ideal qualities. The researchers are combining binary alloys with a variety of additional materials to create the soldering alloys’ ...Although there are many lead-free soldering alloys on the market, none of them have ideal qualities. The researchers are combining binary alloys with a variety of additional materials to create the soldering alloys’ features. The eutectic Sn-9Zn alloy is among them. This paper investigated the mechanical and electrical properties of Sn-9Zn-x (Ag, Cu, Sb);{x = 0.2, 0.4, and 0.6} lead-free solder alloys. The mechanical properties such as elastic modulus, ultimate tensile strength (UTS), yield strength (YS), and ductility were examined at the strain rates in a range from 4.17 10−3 s−1 to 208.5 10−3 s−1 at room temperature. It is found that increasing the content of the alloying elements and strain rate increases the elastic modulus, ultimate tensile strength, and yield strength while the ductility decreases. The electrical conductivity of the alloys is found to be a little smaller than that of the Sn-9Zn eutectic alloy.展开更多
This study focuses on a single-stage axial flow fan, investigating the effect of three kinds of wave leading edge stator blades on its noise reduction. The DDES method and the duct acoustic analogy theory based on the...This study focuses on a single-stage axial flow fan, investigating the effect of three kinds of wave leading edge stator blades on its noise reduction. The DDES method and the duct acoustic analogy theory based on the penetrable data surface were used for noise prediction. The results showed that the three kinds of wave leading edge blades were effective in reducing the rotor-stator interaction tonal noise and also have a certain inhibitory effect on broadband noise. The A10W15 stator blade can effectively reduce broadband noise in the frequency range of 2200 - 4200 Hz. When the amplitude is increased to 20, the noise reduction effect is further enhanced. However, when the amplitude is increased to 30, the broadband noise reduction effect is no longer significant. Further research shows that the wave leading edge stator blades can significantly change the pressure fluctuation distribution on the leading edge and suction surface, which control the modal energy distribution. Finally, this paper analyzed multiple factors affecting the broadband noise reduction, such as the noise source cut-off and cut-on effect and correlation. The purpose of this paper is to explore the laws of the influence of wave leading edge blades on the duct noise of real fan, and to reveal its noise control mechanism. .展开更多
Milk is one of the very important nutrients of human diet. The presence of toxic elements in milk may threaten the public health. This study reports the levels of Cadmium (Cd), Cobalt (Co) and Lead (Pb) in raw cow’s ...Milk is one of the very important nutrients of human diet. The presence of toxic elements in milk may threaten the public health. This study reports the levels of Cadmium (Cd), Cobalt (Co) and Lead (Pb) in raw cow’s milk collected from different areas of Zanzibar Island during March - May 2016. The samples of raw milk were analyzed by Thermo Scientific-Atomic Absorption Spectrophotometer for quantitative determination of the metals in the matrix. The concentration of Co in this study ranged from ND at Mwanakwerekwe (MK1 and MK2) to a maximum of 0.004 mg/L at Mshelishelini (MS5) and Fuoni (F5) sites with mean concentration of 0.020 ± 0.003 mg/L for all sites. Concentration of Pb ranged between 0.05 - 0.51 mg/L at Fuoni (F7) and Mwanakwerekwe (MK1) respectively, with mean concentration of 0.263 ± 0.031 mg/L for all sites. However, Cd was only detected in one sample collected at Fuoni (F3) with a concentration of 0.001 mg/L. The results revealed that cow’s milk is contaminated with toxic metals, particularly Pb which exceeded the WHO maximum permissible level of 0.02 mg/L. The study furthermore sheds light on possible consequences to public health. It is recommended that, stakeholders especially in Zanzibar such as Zanzibar Food and Drug Authorities (ZFDA) and Zanzibar Bureau of Standards (ZBS) as well as researchers, use the findings of this study for policy making, future study plans, formulation of technical strategies to control milk contamination, risk assessment and develop new alternative methods to measure milk contamination even at a low detection limit for the sake of the consumers’ welfare before posing any serious effects to their health.展开更多
Inadvertent Lead Malposition in Left Ventricle is a rare and underdiagnosed incident, which may occur during implantation of cardiac electronic devices and may remain asymptomatic. We reported the case of a 71-year-ol...Inadvertent Lead Malposition in Left Ventricle is a rare and underdiagnosed incident, which may occur during implantation of cardiac electronic devices and may remain asymptomatic. We reported the case of a 71-year-old man who was implanted with a ventricular single-chamber pacemaker for a slow atrial fibrillation with syncope and whose routine transthoracic echocardiography 23 months after implantation displayed a malposition of the pacemaker lead into the Left Ventricle through a patent foramen oval. The patient was asymptomatic. The electrocardiogram showed right bundle branch block QRS-paced morphology with a positive QRS pattern in V1, a median paced QRS axis on the frontal plane at -120°, a Precordial transition on V5. At the lateral Chest X-ray the lead curved backwards to the spine. Given the age of this old patient who already received oral anticoagulant for Atrial Fibrillation and the Lead malposition discovered 23 months after pacemaker’s implantation, we decided to maintain the lead in LV and continue anticoagulation.展开更多
文摘Aim: Lead aprons are used to protect against scattered radiation from the patient during interventional procedures and certain special conventional radiological examinations. Given the importance of the role lead aprons are supposed to play in radiation protection, we propose to assess their conformity in medical imaging departments in public and religious hospitals in Togo. Materials and method: A multi-centre survey conducted from 26 November to 06 December 2021 in the radiology departments of public and religious health facilities in Togo. All aprons in use were included. The evaluation criteria were physical (visual), quantitative (radiographic) and qualitative (dosimetric). Results: We had registred 43 aprons among wich 27 (62.79%) leaded aprons were labelled non-compliant and 16 (37.21%) were labelled compliant. Of the aprons judged to be non-compliant, 70.37% were more than 10 years old and 96.30% showed defects on the radiographic images. The most common defects were vampire marks (18.64%), multiple folds (16.96%), cracks (16.96%), multiple cracks (15.25%), tears (8.47%), absence of lead (5.08%), holes (3.39%) and lead corrosion (1.69%). Defective aprons (62.96%) had at least two defects. The defects were of thoraco-abdomino-pelvic (74.07%), thoracic (14.82%) and abdomino-pelvic (11.11%) topography. For indirect exposure at 50 and 70 kilovolts, all the aprons had an attenuation factor greater than 90%. After dosimetric measurement, 13.95% of aprons had attenuation factors below 90% for indirect exposure at 100 kilovolts. Conclusion: The compliance of the leaded decks is trifactorial (physical, radiographic and dosimetric). However, there is no significant difference in X-ray attenuation capacity between defective and normal decks.
文摘Although there are many lead-free soldering alloys on the market, none of them have ideal qualities. The researchers are combining binary alloys with a variety of additional materials to create the soldering alloys’ features. The eutectic Sn-9Zn alloy is among them. This paper investigated the mechanical and electrical properties of Sn-9Zn-x (Ag, Cu, Sb);{x = 0.2, 0.4, and 0.6} lead-free solder alloys. The mechanical properties such as elastic modulus, ultimate tensile strength (UTS), yield strength (YS), and ductility were examined at the strain rates in a range from 4.17 10−3 s−1 to 208.5 10−3 s−1 at room temperature. It is found that increasing the content of the alloying elements and strain rate increases the elastic modulus, ultimate tensile strength, and yield strength while the ductility decreases. The electrical conductivity of the alloys is found to be a little smaller than that of the Sn-9Zn eutectic alloy.
文摘This study focuses on a single-stage axial flow fan, investigating the effect of three kinds of wave leading edge stator blades on its noise reduction. The DDES method and the duct acoustic analogy theory based on the penetrable data surface were used for noise prediction. The results showed that the three kinds of wave leading edge blades were effective in reducing the rotor-stator interaction tonal noise and also have a certain inhibitory effect on broadband noise. The A10W15 stator blade can effectively reduce broadband noise in the frequency range of 2200 - 4200 Hz. When the amplitude is increased to 20, the noise reduction effect is further enhanced. However, when the amplitude is increased to 30, the broadband noise reduction effect is no longer significant. Further research shows that the wave leading edge stator blades can significantly change the pressure fluctuation distribution on the leading edge and suction surface, which control the modal energy distribution. Finally, this paper analyzed multiple factors affecting the broadband noise reduction, such as the noise source cut-off and cut-on effect and correlation. The purpose of this paper is to explore the laws of the influence of wave leading edge blades on the duct noise of real fan, and to reveal its noise control mechanism. .
文摘Milk is one of the very important nutrients of human diet. The presence of toxic elements in milk may threaten the public health. This study reports the levels of Cadmium (Cd), Cobalt (Co) and Lead (Pb) in raw cow’s milk collected from different areas of Zanzibar Island during March - May 2016. The samples of raw milk were analyzed by Thermo Scientific-Atomic Absorption Spectrophotometer for quantitative determination of the metals in the matrix. The concentration of Co in this study ranged from ND at Mwanakwerekwe (MK1 and MK2) to a maximum of 0.004 mg/L at Mshelishelini (MS5) and Fuoni (F5) sites with mean concentration of 0.020 ± 0.003 mg/L for all sites. Concentration of Pb ranged between 0.05 - 0.51 mg/L at Fuoni (F7) and Mwanakwerekwe (MK1) respectively, with mean concentration of 0.263 ± 0.031 mg/L for all sites. However, Cd was only detected in one sample collected at Fuoni (F3) with a concentration of 0.001 mg/L. The results revealed that cow’s milk is contaminated with toxic metals, particularly Pb which exceeded the WHO maximum permissible level of 0.02 mg/L. The study furthermore sheds light on possible consequences to public health. It is recommended that, stakeholders especially in Zanzibar such as Zanzibar Food and Drug Authorities (ZFDA) and Zanzibar Bureau of Standards (ZBS) as well as researchers, use the findings of this study for policy making, future study plans, formulation of technical strategies to control milk contamination, risk assessment and develop new alternative methods to measure milk contamination even at a low detection limit for the sake of the consumers’ welfare before posing any serious effects to their health.
文摘Inadvertent Lead Malposition in Left Ventricle is a rare and underdiagnosed incident, which may occur during implantation of cardiac electronic devices and may remain asymptomatic. We reported the case of a 71-year-old man who was implanted with a ventricular single-chamber pacemaker for a slow atrial fibrillation with syncope and whose routine transthoracic echocardiography 23 months after implantation displayed a malposition of the pacemaker lead into the Left Ventricle through a patent foramen oval. The patient was asymptomatic. The electrocardiogram showed right bundle branch block QRS-paced morphology with a positive QRS pattern in V1, a median paced QRS axis on the frontal plane at -120°, a Precordial transition on V5. At the lateral Chest X-ray the lead curved backwards to the spine. Given the age of this old patient who already received oral anticoagulant for Atrial Fibrillation and the Lead malposition discovered 23 months after pacemaker’s implantation, we decided to maintain the lead in LV and continue anticoagulation.