期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
On-line detecting of transformer winding deformation based on parameter identification of leakage inductance
1
作者 郝治国 张保会 李朋 《Journal of Pharmaceutical Analysis》 SCIE CAS 2007年第1期24-28,共5页
Transformers are required to demonstrate the ability to withstand short circuit currents.Over currents caused by short circuit can give rise to windings deformation.In this paper,a novel method is proposed to monitor ... Transformers are required to demonstrate the ability to withstand short circuit currents.Over currents caused by short circuit can give rise to windings deformation.In this paper,a novel method is proposed to monitor the state of transformer windings,which is achieved through on-line detecting the leakage inductance of the windings.Specifically,the mathematical model is established for online identifying the leakage inductance of the windings by applying least square algorithm(LSA) to the equivalent circuit equations.The effect of measurement and model inaccuracy on the identification error is analyzed,and the corrected model is also given to decrease these adverse effect on the results.Finally,dynamic test is carried out to verify our method.The test results clearly show that our method is very accurate even under the fluctuation of load or power factor.Therefore,our method can be effectively used to on-line detect the windings deformation. 展开更多
关键词 leakage inductance parameter identification windings deformation on-line monitoring least square equivalent circuit equation
下载PDF
The Effect of Leakage Inductance on High Frequency Transformer Harmonics
2
作者 B. Abdi M.H. Joukar A.H. Ranjbar A.A. Nasiri 《Journal of Energy and Power Engineering》 2011年第7期659-664,共6页
Nowadays, switching power supplies are used in almost all electronic devices to regulate the voltage amplitude. The only obstacle on using these devices is the production of high frequency harmonics that violates diff... Nowadays, switching power supplies are used in almost all electronic devices to regulate the voltage amplitude. The only obstacle on using these devices is the production of high frequency harmonics that violates different standards such as (FCC, VDE, 461 ). In this paper the sources of various noises in switching power supplies will be introduced. Then, using appropriate model for high frequency transformers, a sample switching power supply will be simulated. In this simulation, the effect of leakage inductance on current and voltage waveforms of the input and output switches, which are the main cause of common mode differential mode noises and radiations, will be discussed and harmonically analyzed. Finally the experimental results will confirm the simulation conclusions. 展开更多
关键词 EMI HF transformer harmonic simulation intrinsic capacitance leakage inductance SMPS.
下载PDF
Mathematical model analysis of new-type magnetic integrated CRT considering magnetic leakage
3
作者 WANG Tiange TIAN Mingxing ZHANG Huiying 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2022年第1期31-40,共10页
A novel magnetic integrated controllable reactor of transformer type(CRT)has the advantages of simple structure,flexible assembly,convenient maintenance and practicability.To analyze its operation characteristics accu... A novel magnetic integrated controllable reactor of transformer type(CRT)has the advantages of simple structure,flexible assembly,convenient maintenance and practicability.To analyze its operation characteristics accurately,we establish corresponding equivalent mathematical model considering magnetic leakage based on magnetic circuit and circuit dualistic transformation method.The distribution of magnetic leakage field of each winding is analyzed qualitatively,and the analytical calculation formulas of magnetizing inductance and leakage inductance of each winding are derived.Based on this,the analytical calculation formulas of short-circuit impedance and winding current of CRT under different working conditions are derived.The field-circuit coupling finite element model of the magnetic integrated CRT is established to simulate the current of each winding under different working conditions.The results show that the analytical calculation results of each winding current have good consistency with the finite element calculation results,indicating the validity of CRT equivalent mathematical model and correctness of the analytical formulas of leakage inductance,short-circuit impedance and winding current of CRT.The working winding current of CRT is increasing gradually with the operation of control winding in turn to realise the transition of CRT compensation capacity from zero to a rated value. 展开更多
关键词 controllable reactor of transformer type(CRT) magnetic integration technology equivalent mathematical model leakage inductance winding current
下载PDF