Background:To evaluate efficacy and safety of combined pars plana vitrectomy(PPV)and scleral fixated intraocular lens(SFIOL)surgery as a single procedure.Methods:Retrospective interventional case series done at a tert...Background:To evaluate efficacy and safety of combined pars plana vitrectomy(PPV)and scleral fixated intraocular lens(SFIOL)surgery as a single procedure.Methods:Retrospective interventional case series done at a tertiary eye care center in Northern India.Eleven patients who underwent combined PPV and SFIOL surgery were included and analyzed retrospectively.Results:Mean age of the patients was 43.36±15.12 years(range,22-64 years).Eight were male.Mean baseline best corrected visual acuity(BCVA)was 0.78±0.63 logMAR units while the mean post-operative BCVA at 6 months follow-up was 0.37±0.29 logMAR units,the visual gain being statistically significant(P=0.021).None of the patients had a drop in BCVA with nine patients having final BCVA better than 0.48 logMAR units.Choroidal detachment(CD)was the only notable complication,seen in three patients.Other complications included two cases of intraoperative retinal breaks,a case each of reversible corneal edema,ocular hypertension and cystoid macular edema.Conclusions:Combined PPV and SFIOL is an efficacious procedure for managing IOL/lens dislocation and aphakia in a single surgery.There may be short-term reversible complications with no impact on final visual gain.展开更多
AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,W...AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,Web of Science,Cochrane Library and several Chinese databases were searched at May 2021 to select relevant studies in comparison of clinical outcomes between ICL implantation and SMILE for myopia.The primary outcomes were efficacy,safety,and predictability.And the secondary outcomes were postoperative higher-order ocular aberrations(HOAs),modulation transfer function cutoff frequency(MTF),objective scatter index(OSI),contrast sensitivity and a quality of vision(Qo V)questionnaire.RESULTS:A total of 1036 eyes from 10 studies,of which 503 eyes underwent ICL implantation and 533 eyes underwent SMILE,were enrolled in this Meta-analysis.Pooled results revealed that ICL group had a better safety index and post-corrected distance visual acuity(CDVA)(P=0.007,<0.00001,respectively),and a lower percentage of eyes with a postoperative CDVA lost 1 line(P=0.007)than the SMILE group.No significant differences were found in comparison of the other primary outcomes.In the longterm follow-up(>6mo),ICL group had a lower total HOA,coma,and spherical aberration than SMILE group(P=0.003,<0.00001,0.04).Yet higher trefoil was found in ICL group at 6mo after surgery(P=0.003).Additionally,ICL group also had a higher MTF value(P=0.02),and a higher contrast sensitivity score for spatial frequencies of 1.5,6,and 12 cpds(P=0.02,0.005,0.02,respectively).And it also had a lower score of bothersome in Qo V questionnaire than SMILE group(P=0.003).CONCLUSION:ICL implantation and SMILE have similar and comparable outcomes in term of the efficacy and predictability for correcting high myopia.However,ICL group is relatively safer and also has better visual quality in comparison of SMILE group.展开更多
AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted...AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted on 58 patients(114 eyes)who were followed up for at least 5y after ICL V4c implantation.The observation was done before and on 1d,1mo,1 and 5y or more after the surgical procedure.The visual acuity,subjective refraction,intraocular pressure,vault,axial length,central hole position,pupil diameter,visual quality,and adverse events were analyzed.The visual quality includes aberration,the modulation transfer function cutoff frequency(MTF cutoff),objective scattering index(OSI),Stroller's ratio(SR),and visual quality questionnaire.RESULTS:The average follow-up period was 69.25±3.80mo(range 60–82mo)and the preoperative spherical equivalent(SE)was-8.66±1.97 D.At 5y after operation,the safety index was 1.01±0.02 and the efficacy index was 0.99±0.42 and SE was-0.65±0.63 D.The 59.6%of the eyes achieved an uncorrected distance visual acuity of 20/20,76.3%of the eyes had SE within±1.0 D at the last visit.The axial length increased by 0.29±0.71 mm 5y after the surgery(t=-3.843,P<0.001).The mean vault at the last follow-up was 510.59±245.61μm.The central hole was on the temporal side in 80 eyes(84.2%).The visual quality questionnaire showed that 98.2%patients were satisfied with the surgical procedure.Adverse events occurred in 4 eyes(3.5%),including the posttraumatic toric ICL rotation(2 eyes),iris incarceration(1 eye),and posttraumatic ICL displacement(1 eye)at the last follow-up.CONCLUSION:Long-term ICL V4c implantation is safe,effective,and stable for correcting moderate and to high myopia,and the visual quality with patients is excellent and satisfactory,but the progression of axial length still needs attention after surgery.展开更多
Posterior capsule opacification(PCO) remains the most common complication of pediatric cataract surgery despite continuous efforts to reduce its incidence. For this reason, pediatric cataract surgeons have expended ...Posterior capsule opacification(PCO) remains the most common complication of pediatric cataract surgery despite continuous efforts to reduce its incidence. For this reason, pediatric cataract surgeons have expended considerable effort into preventing and mitigating PCO. The intraocular lens(IOL) optic capture technique has been used for the prevention of PCO after pediatric cataract surgery for more than 20 y, but there is still no professional consensus. However, recent research has shown encouraging results. The IOL optic capture technique can be performed without anterior vitrectomy to prevent PCO, even in younger children. The type and characteristics of IOLs used for optic capture technique, the location of IOL and the complications of IOL optic capture in children are here reviewed.展开更多
AIM: To evaluate human lens epithelium cell apoptosis and epithelial to mesenchymal transition (EMT) induced by femtosecond laser in femtosecond laser assisted cataract surgery (FLACS). METHODS: Sixty cataract ...AIM: To evaluate human lens epithelium cell apoptosis and epithelial to mesenchymal transition (EMT) induced by femtosecond laser in femtosecond laser assisted cataract surgery (FLACS). METHODS: Sixty cataract patients with N2 to N3 stage according to the LOCS III were enrolled in this study and divided into three groups randomly: FLACSl group (cataract surgery by FLACS with LenSx), FLACS2 group (cataract surgery by FLACS with LensAR) and manual group (cataract surgery by phacoemulsification). Patients in two FLACS groups performed anterior capsulotomy by LenSx or LensAR laser system. Patients in the manual group were performed continuous curvilinear capsulorrhexis (CCC) manually. The anterior capsules were fixed right after moved out of eye. Hematoxylin-eosine staining, immunofluorescence staining and real-time PCR were performed in order to observe human lens epithelium cells changes after cataract surgery. RESULTS: The capsule cutting edge was shown irregularity and roughness in two FLACS groups and smooth edge in manual capsulotomy by pathologic staining. Irregularities of the cell configuration with partly swollen and destroyed nuclei were observed in two FLACS groups. Femtosecond laser could induce a significantly higher cell apoptosis in human lens epithelium cell than manually performed CCC (P〈0.05). Lens epithelium cells apoptosis were correlated with femtosecond laser duration according to Pearson correlation analysis. Decreased N-cadherin expression, alpha-SMA and FSP-1 level in two FLACS groups showed the inhibition of cell EMT. CONCLUSION: Femtosecond laser may affect the apoptosis and EMT of lens epithelium cells which are under the peeled central lens capsule.展开更多
At present, the incidence of infectious endophthalmitis after cataract surgery has been significantly reduced, but it is still a serious complication. Removal or not of the intraocular lens(IOL) during vitrectomy in c...At present, the incidence of infectious endophthalmitis after cataract surgery has been significantly reduced, but it is still a serious complication. Removal or not of the intraocular lens(IOL) during vitrectomy in cases with a moderate or severe inflammation is controversial. In order to call upon more discussion, we publish the article entitled “Timely vitrectomy without intraocular lens removal for acute endophthalmitis after cataract surgery” written by Guo et al in this issue. With recent advanced vitrectomy techniques, and critical measures for management of risk factors related to occurrence of infection, IOL remaining during timely vitrectomy for acute endophthalmitis can possibly be safe and effective in selected cases.展开更多
AIM: To evaluate the safety of therapeutic bandage contact lens for post-cataract surgery patients and to illustrate its efficacy on post-operative comfort and tear-film stability. METHODS: A total of 40 participant...AIM: To evaluate the safety of therapeutic bandage contact lens for post-cataract surgery patients and to illustrate its efficacy on post-operative comfort and tear-film stability. METHODS: A total of 40 participants were recruited and randomly divided into two groups. Group one was instructed to wear bandage contact lenses for a week and use antibiotic eye drops for a month since the first day after surgery. Group two received sub-conjunctival injection of tobramycin and was asked to wear eye pads on the first day after surgery and then were instructed to use antibiotic eye drops as the first group did. Ocular surface disease index(OSDI) questionnaire, slit-lamp microscope examination of tear break-up time(TBUT), corneal fluorescein score(CFS), tear meniscus height(TMH) together with anterior segment optical coherence tomography(AS-OCT) and corneal topography were evaluated preoperatively and postoperatively. RESULTS: The subjective feeling(P=0.004), TBUT(P〈0.001) and TMH(P=0.02) post-surgery had improved in patients who used bandage contact lenses compared with those who did not at 1wk post-surgery. Until three month postoperatively, the comfort degree(P=0.004) and TMH(P=0.01) of group two were still worse than group one. Moreover, TBUT(P〈0.001) and CFS(P=0.004) of the group with eye pads got worse than the results before, whereas the group with bandage contact lenses recovered to normal. None of these patients had infections or other complications. CONCLUSION: Wearing therapeutic bandage contact lens after cataract surgery, compared with traditional eye-pads, is a safe method to improve tear-film stability and reduce post-operative discomfort without hindering corneal incision recovery.展开更多
AIM: To evaluate the effect of femtosecond laser-assisted lens surgery(FLALS;cataract surgery or refractive lens exchange) on the structure of the optic nerve head and the macula.METHODS: This prospective longitudinal...AIM: To evaluate the effect of femtosecond laser-assisted lens surgery(FLALS;cataract surgery or refractive lens exchange) on the structure of the optic nerve head and the macula.METHODS: This prospective longitudinal study included healthy eyes undergoing FLALS. Eyes with glaucoma or any other ocular disease that could alter optical coherence tomography results were excluded. Retinal nerve fiber layer(RNFL), Bruch’s membrane opening-minimum rim width(BMO-MRW) and macular thickness(MT) were measured preoperatively, 1 and 6 mo after surgery using spectral-domain optical coherence tomography(SD-OCT). Changes between preoperative and postoperative values were evaluated.RESULTS: A total of 87 eyes of 46 patients were included in this study. Preoperative RNFL, BMO-MRW and MT in microns(μm) were 100.77±10.39, 330.31±49.99 and 276.30±33.39, respectively. Postoperative RNFL, BMO-MRW and MT were 104.74±11.55, 348.32±54.05 and 279.83±22.65 1 mo after surgery and 102.93±11.17, 343.11±53.4 and 278.90±22.19 6 mo after surgery, respectively;which equals an increase of 3.93%, 5.45% and 1.27%,respectively, 1 mo after surgery, and 2.14%, 3.87% and 0.94% 6 mo after surgery. The differences between the preoperative and the postoperative RNFL and BMO-MRW values were statistically significant(P<0.001). Regarding MT values, there were not statistically significant differences(P=0.26).CONCLUSION: Our study suggests that FLALS does not have a negative impact on the structural status of the optic nerve head in healthy eyes, assessed by SD-OCT. There is a slight increase in the values of RNFL, BMO-MRW and MT 1 mo and 6 mo after surgery.展开更多
Introduction: To report by using topical anesthesia for standing phacoemulsification and intraocular lens implantation for two patients who need cataract extraction but unable to lie flat with marked cervical kyphosis...Introduction: To report by using topical anesthesia for standing phacoemulsification and intraocular lens implantation for two patients who need cataract extraction but unable to lie flat with marked cervical kyphosis due to long-standing ankylosing spondylitis and chronic uveitis. Methods: Two patients are unable to lie flat respectively during phacoemulsification underwent this technique in Jingdong and Tonghai county Hospital of Yunnan province in China. Each patient was positioned erect or semirecumbent in a standard reclining cataract surgical chair. The ceiling-mounted microscope was rotated 60 degrees from the vertical to point toward the patient. Results: The intraoperative and postoperative periods were uneventful in two patients, with good visual outcomes after surgery. Conclusion: This technique is valuable for situations where the patient requires upright positioning because of the inability to recline flat, and should be considered for cases where standard surgical positioning is not possible.展开更多
AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent biman...AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent bimanual microincision cataract surgery(B-MICS).METHODS:Eighty eyes which underwent cataract surgery using B-MICS technique performed by the same experienced surgeon were included in the study:40 eyes were implanted with an Incise?MJ14 IOL through a 1.4 mm CCI(group A)without enlargement of the main CCI,while 40 eyes were implanted with an Akreos?MI60 IOL with enlargement of the main CCI to 1.8 mm(group B).Best corrected visual acuity(BCVA),astigmatism and endothelial cell loss were evaluated before and after surgery at 7,30d and 6mo.Anterior segment-optical coherence tomography(AS-OCT)of CCI was performed at 1,3,7,30d,6 and 18mo.PCO incidence was evaluated at 18mo using EPCO 2000 Software.RESULTS:Mean BCVA improvement and endothelial cell loss were statistically significant at 18mo in both groups with no difference between the two groups;no statistically significant difference in surgically induced astigmatism(SIA)was noticed in the two groups.At AS-OCT the only significant alterations in the CCI were endothelial gaping and local detachment of Descemet’s membrane at 1 and 7d after surgery;no statistically significant alterations were found at 1,6 and 18mo.PCO score at 18mo was 0.03±0.07for group A and 0.08±0.18 for group B(P=0.11)with no sign of central optic plate invasion in both groups.CONCLUSION:The implant of the new Incise?MJ14 IOL through a 1.4 mm CCI and B-MICS technique appeared to be a safe and effective procedure with rapid visual recovery.PCO rate resulted very low and the CCI presented few morphological alterations which were only detectable in the first days postoperatively and achieved fast corneal healing during the long-term follow-up.展开更多
Many organisms have evolved an approximately 24-hour circadian rhythm that allows them to achieve internal physiological homeostasis with external environment.Suprachiasmatic nucleus(SCN) is the central pacemaker of...Many organisms have evolved an approximately 24-hour circadian rhythm that allows them to achieve internal physiological homeostasis with external environment.Suprachiasmatic nucleus(SCN) is the central pacemaker of circadian rhythm,and its activity is entrained to the external light-dark cycle.The SCN controls circadian rhythm through regulating the synthesis of melatonin by pineal gland via a multisynaptic pathway.Light,especially shortwavelength blue light,is the most potent environmental time cue in circadian photoentrainment.Recently,the discovery of a novel type of retinal photoreceptors,intrinsically photosensitive retinal ganglion cells,sheds light on the mechanism of circadian photoentrainment and raises concerns about the effect of ocular diseases on circadian system.With age,light transmittance is significantly decreased due to the aging of crystalline lens,thus possibly resulting in progressive loss of circadian photoreception.In the current review,we summarize the circadian physiology,highlight the important role of light in circadian rhythm regulation,discuss about the correlation between age-related cataract and sleep disorders,and compare the effect of blue light-filtering intraocular lenses(lOLs) and ultraviolet only filtering lOLs on circadian rhythm.展开更多
【正】Dear Sir,Iam Yong-Sun Ahn,from the Department of Ophthalmology of St.Vincent Hospital of Suwon,Kyungki-do,South Korea.Cataracts are a common problem in eyes with a glaucoma drainage device(GDD),because tube shun...【正】Dear Sir,Iam Yong-Sun Ahn,from the Department of Ophthalmology of St.Vincent Hospital of Suwon,Kyungki-do,South Korea.Cataracts are a common problem in eyes with a glaucoma drainage device(GDD),because tube shunt surgery increases the incidence and progression of cataracts[1].An Ahmed valve,the most commonly inserted GDD,is composed of a silicone tube connected to a flat plate sewn to the sclera,and aqueous humor flows from the展开更多
Background:Femtosecond laser astigmatic keratotomy(FSAK)and toric intraocular lens(IOL)implantation have been studied individually for comparison to treat astigmatism at cataract surgery.We report a case of surgically...Background:Femtosecond laser astigmatic keratotomy(FSAK)and toric intraocular lens(IOL)implantation have been studied individually for comparison to treat astigmatism at cataract surgery.We report a case of surgically induced high corneal astigmatism by laser thermal keratoplasty(LTK)in a patient with cataract who was successfully treated with simultaneous combination of FSAK and toric IOL implantation with femtosecond laser-assisted cataract surgery(FLACS).This is the first report of both procedures combined simultaneously,with or without history of LTK.Case Description:A 68-year-old male presented with a history of LTK with two enhancements each eye in 2004,with subsequent surgically induced high corneal astigmatism,and with age-related nuclear cataract of both eyes.IOL master demonstrated+7.71 diopters of astigmatism at 163 degree right eye and+3.29 diopters of astigmatism at 4 degree left eye.After extensive discussion of the risks and benefits,the patient agreed to undergo FLACS with FSAK with two 61 degrees of relaxation incisions(RIs)and toric IOL(Alcon SN6AT9)right eye;FLACS with toric IOL(Alcon SN6AT7)alone left eye.At 2-year follow-up,uncorrected visual acuity was 20/30 right eye,20/25 left eye.His best corrected visual acuity was 20/25(+0.25+1.00 axis 21)right eye and 20/20(plano+0.25 axis 90)left eye;his best corrected near visual acuity was J1+with add+2.50 diopters right eye and left eye.Conclusions:Patients with age-related cataract and LTK induced high corneal astigmatism can hardly be sufficiently treated with FSAK or toric IOL alone at the time of cataract surgery.An effective way is to combine large FSAK and toric IOL of the highest cylindrical power of T9,in our case,simultaneously,which can achieve an excellent long term visual outcome.展开更多
AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who...AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who received sulcus-placed SPA-IOLs between 2006 and 2009 were reviewed. None of the patients underwent IOL exchange. Charts of six age-matched patients who received sulcus placed 3P-IOLs were reviewed as a control group. RESULTS: Mean follow up was 16 mo for SPA-IOL and 23 mo for 3P-IOL. Five of 8 patients in the SPA-IOL group required chronic use of IOP lowering medications at final follow up. Of these, one patient needed glaucoma implant surgery for uncontrolled IOP. One patient in the 3P-IOL group used chronic aqueous suppression pre- and postoperatively. Four of eight eyes with SPAIOL were treated with chronic topical steroids and or non-steroidal anti-inflammatory drugs for cystoid macu-la edema, chronic uveitis, pigment dispersion syndrome or a combination of the above, compared to none in the control group. Mean best-corrected visual acuity was 20/35 in the SPA-IOL group and 20/47 in the 3PIOL group.CONCLUSION: Sulcus placed SPA-IOLs are associated with increased ocular morbidity. In select cases good visual acuity may be achieved. Due to postoperative rotation of sulcus placed toric SPA-IOLs stable astigmatism correction cannot be achieved. Alternative intraocular lenses should be considered when in-the-bag placement of SPA-IOL is not possible.展开更多
Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number...Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number of focal points that each lens provides,which in turn leads to different visual outcomes.Familiarity of surgeons with the various characteristics of each lens is of utmost importance for accurate IOL selection to match each patient’s needs.In this review,we aim to compare the clinical outcomes after implantation of multifocal and EDOF IOLs in terms of distance,intermediate and near vision,contrast sensitivity,and reading performance.Finally,we discuss the defocus curve and the optical and photic phenomena associated with each type of IOL.展开更多
Purpose:.To compare toric intraocular lens implantation(ToricIOL).with peripheral corneal relaxing incisions(PCRIs) for astigmatism correction in patients undergoing cataract surgery.Methods: 54 patients(54 eyes) with...Purpose:.To compare toric intraocular lens implantation(ToricIOL).with peripheral corneal relaxing incisions(PCRIs) for astigmatism correction in patients undergoing cataract surgery.Methods: 54 patients(54 eyes) with more than 0.75 diopter(D).of preexisting corneal astigmatism were classified as group A(0.75-1.50D) or group B(1.75-2.50D). The patients were randomized to undergo Toric-IOL or PCRIs in the steep axis with spherical IOL implantation..Log MAR uncorrected visual acuity(Log MAR UCVA), Log MAR best corrected vi sual acuity.(Log MAR BCVA),.error of vector(|EV|), surgery induced refraction correction.(|SIRC |),.and correction rates(CR) were measured 1 month and 6 months postoperatively.Results: At 6 months postoperatively, all 54 eyes had LogMAR BCVA≤0.2. Patients who underwent PCRIs and ToricIOL with Log MAR BCVA≤0.1 showed no significant differences in group A(P=1.00) or in group B(P=0.59). Group A showed no significant differences in Log MAR UCVA(P =0.70), |EV|(P=0.13), |SIRC|(P=0.71), and CR(P=0.56)in patients underwent PCRIs and Toric-IOL. However, group B showed significant differences in Log MAR UCVA(P <0.01), |EV|(P<0.01)), |SIRC|(P<0.01), and CR(P<0.01).The Log MAR UCVA and |EV | between 1 and 6 months showed no significant differences in patients in group A. However, in group B, they are significant differences.Conclusion:.The efficacy and stability of Toric-IOL and PCRIs were equal in low astigmatic patients..Toric-IOL achieved an enhanced effect over PCRIs in higher astigmatic patients.PCRIs had the more refractive regression than Toric-IOL in 6months.展开更多
AIM:To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens(IOL)during a 12-month follow-up.METHODS:Prospective comparative study including75 eyes of 38 patients(44-...AIM:To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens(IOL)during a 12-month follow-up.METHODS:Prospective comparative study including75 eyes of 38 patients(44-70y)undergoing uneventful cataract surgery.Each patient was randomly assigned to one type of IOL,bifocal(35 eyes)or trifocal(40 eyes).Visual,refractive,and contrast sensitivity changes were evaluated in a 12-month follow-up.The binocular defocus curve was also measured at 12mo postoperatively.RESULTS:No statistically significant differences between groups were found in postoperative uncorrected and corrected distance visual acuities(P≥0.276).Postoperative corrected near visual acuity(33 cm)was significantly better in the trifocal group during all follow-up(P≤0.004)as well as 6-month uncorrected near(P=0.008)and distancecorrected near visual acuities(P=0.016)(33/40 cm).Significantly better uncorrected intermediate and distance corrected-intermediate visual acuity were found during all follow-up in the trifocal group(P〈0.001),which was consistent with differences among groups in binocular defocus curve.Differences among groups in contrast sensitivity were minimal,being only significant at 6 months for some low to medium spatial frequencies(P≤0.006).CONCLUSION:Bifocal and trifocal diffractive IOLs are able to provide an effective visual restoration which is maintained during a 12-month follow-up,with a clear benefit of the trifocal IOL for the intermediate vision.展开更多
Purpose: To assess the visual outcome after implantation of the new Hydrophylic IOL type 41 B/G accommodating intraocular lens (AIOL). Methods: The presented lens was implanted during cataract surgery. All patients we...Purpose: To assess the visual outcome after implantation of the new Hydrophylic IOL type 41 B/G accommodating intraocular lens (AIOL). Methods: The presented lens was implanted during cataract surgery. All patients were offered follow-ups, allowing two postoperative measurements to be performed at 3 months and between 2020 and 2021. The mean time between lens implantation and last follow-up was 5.3 years (min. 1 year, max. 10 years). Excluded were patients with age-related macular degeneration or amblyopia. Patients with a foreign lens implanted into the second eye were included in a separate control group. Corrected distance (CDVA) and uncorrected distance visual acuity (UDVA) at 5 m, and corrected near (CNVA) and uncorrected near visual acuity (UNVA) at 40 cm were assessed. Furthermore, the postoperative spherical equivalent (SE), the dependence on spectacles and the occurrence of optical phenomena were evaluated. Results: The final study cohort consists of 65 patients with 119 implanted AIOLs. Significantly better visual results were obtained in both postoperative follow-ups compared with the preoperative results. The mean values of the last follow-up for the UNVA, CNVA, UDVA, and CDVA were 0.107 ± 0.10;0.039 ± 0.08;0.097 ± 0.11;and 0.040 ± 0.09 logMAR, respectively. Visual outcomes remained on a high level for up to 10 years and showed significantly better results compared to the control group. Postoperative SE was significantly improved. Nearly 70% of patients were no longer dependent on glasses. Furthermore, the occurrence of disturbing optical phenomena was denied by all patients. Conclusion: The results of this AIOL are particularly promising, especially since gratifying visual results could still be measured 10 years after implantation.展开更多
AIM:To evaluate the clinical outcomes of V4 c implantable collamer lens(Hole ICL) implantation with regard to the optical quality assessed according to different degrees of decentering.METHODS:This included 49 eye...AIM:To evaluate the clinical outcomes of V4 c implantable collamer lens(Hole ICL) implantation with regard to the optical quality assessed according to different degrees of decentering.METHODS:This included 49 eyes that received conventional ICL and 94 eyes that received Hole ICL.The eyes that received Hole ICL were divided into three groups according to the degree of decentering:group 1,central hole within 1 hole diameter(HD) from the pupil center;group 2,central hole within 1 HD to 2 HD;and group 3,central hole within 2 HD to 3 HD.Visual acuity(VA),intraocular pressure(IOP),and spherical equivalent(SE) values were assessed at 1wk,1 and 3mo after surgery.The ocular modulation transfer function,Strehl ratio,objective scattering index,and higher order aberrations(HOAs) were measured for 4-mm pupils at 3mo after surgery.RESULTS:There were no significant differences in VA,IOP,and SE among the conventional and Hole ICL groups.With regard to HOAs,values for coma and spherical aberrations showed no differences.The total HOA and trefoil values were significantly higher in group 2 than in group 1(P=0.02,0.03,respectively).There were no significant differences among groups with regard to other optical quality parameter at 3mo after surgery.CONCLUSION:Our results suggest that Hole ICL implantation provides satisfactory visual quality that is equivalent to that provided by conventional ICL,regardless of the presence of central hole and degree of decentering.展开更多
AIM: To assess the outcomes of posterior chamber implantable collamer lens (ICL) implantation in Chinese pediatric patients with unilateral high myopic amblyopia.METHODS: Eleven eyes of 11 amblyopic patients aged ...AIM: To assess the outcomes of posterior chamber implantable collamer lens (ICL) implantation in Chinese pediatric patients with unilateral high myopic amblyopia.METHODS: Eleven eyes of 11 amblyopic patients aged 11.02±3.34y underwent ICL (model V4, Staar Surgical Inc.) implantation to treat unilateral anisometropia were studied. Visual acuity, cycloplegic refraction, contrast sensitivity, stereopsis, intraocular pressure (IOP), vaulting, corneal endothelial cell count and complications were evaluated. Patients completed follow-up at 3d, 1, 3mo and the last follow-up time (mean 8.18±2.82mo) after surgery.RESULTS: The mean myopic anisometropia was -13.70±3.25 D preoperatively and +0.69±2.63 D at 8mo postoperatively. The logMAR corrected distance visual acuity (CDVA) of the amblyopic eye was 1.51±0.72 preoperatively and 0.75±0.40 at 8mo postoperatively. The logMAR CDVA at 3d, 1, 3 and 8mo postoperatively improved by a mean of 0.64, 1.55, 1.82 and 2.64 lines and gained more than 2 lines accounted for 18%, 45%, 45%, 64%, respectively. The contrast sensitivity of 0.5, 1 and 2 cpd in amblyopic eyes was significantly increased after surgery. No patient had near stereopsis recovery. The vaulting at 3 and 8mo was significantly lower than that at 1mo postoperatively. No other intraoperative or postoperative complications were observed, except an acute pupillary block glaucoma happened in a patient at two weeks postoperatively.CONCLUSION: This short-term results indicate that ICL implantation can be a promising alternative therapy for high myopic anisometropic amblyopia in pediatric patients who have failed with conventional treatments and not suitable to corneal refraction surgery.展开更多
文摘Background:To evaluate efficacy and safety of combined pars plana vitrectomy(PPV)and scleral fixated intraocular lens(SFIOL)surgery as a single procedure.Methods:Retrospective interventional case series done at a tertiary eye care center in Northern India.Eleven patients who underwent combined PPV and SFIOL surgery were included and analyzed retrospectively.Results:Mean age of the patients was 43.36±15.12 years(range,22-64 years).Eight were male.Mean baseline best corrected visual acuity(BCVA)was 0.78±0.63 logMAR units while the mean post-operative BCVA at 6 months follow-up was 0.37±0.29 logMAR units,the visual gain being statistically significant(P=0.021).None of the patients had a drop in BCVA with nine patients having final BCVA better than 0.48 logMAR units.Choroidal detachment(CD)was the only notable complication,seen in three patients.Other complications included two cases of intraoperative retinal breaks,a case each of reversible corneal edema,ocular hypertension and cystoid macular edema.Conclusions:Combined PPV and SFIOL is an efficacious procedure for managing IOL/lens dislocation and aphakia in a single surgery.There may be short-term reversible complications with no impact on final visual gain.
基金Supported by National Natural Science Foundation of China(No.82070937,No.81870640)National Science Foundation for Young Scientists of China(No.82101097)。
文摘AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,Web of Science,Cochrane Library and several Chinese databases were searched at May 2021 to select relevant studies in comparison of clinical outcomes between ICL implantation and SMILE for myopia.The primary outcomes were efficacy,safety,and predictability.And the secondary outcomes were postoperative higher-order ocular aberrations(HOAs),modulation transfer function cutoff frequency(MTF),objective scatter index(OSI),contrast sensitivity and a quality of vision(Qo V)questionnaire.RESULTS:A total of 1036 eyes from 10 studies,of which 503 eyes underwent ICL implantation and 533 eyes underwent SMILE,were enrolled in this Meta-analysis.Pooled results revealed that ICL group had a better safety index and post-corrected distance visual acuity(CDVA)(P=0.007,<0.00001,respectively),and a lower percentage of eyes with a postoperative CDVA lost 1 line(P=0.007)than the SMILE group.No significant differences were found in comparison of the other primary outcomes.In the longterm follow-up(>6mo),ICL group had a lower total HOA,coma,and spherical aberration than SMILE group(P=0.003,<0.00001,0.04).Yet higher trefoil was found in ICL group at 6mo after surgery(P=0.003).Additionally,ICL group also had a higher MTF value(P=0.02),and a higher contrast sensitivity score for spatial frequencies of 1.5,6,and 12 cpds(P=0.02,0.005,0.02,respectively).And it also had a lower score of bothersome in Qo V questionnaire than SMILE group(P=0.003).CONCLUSION:ICL implantation and SMILE have similar and comparable outcomes in term of the efficacy and predictability for correcting high myopia.However,ICL group is relatively safer and also has better visual quality in comparison of SMILE group.
基金Supported by the Science and Technology Innovation Program of Hunan Province,China(No.2020SK50103)Hunan Clinical Medical Technology Innovation Guiding Project in 2020。
文摘AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted on 58 patients(114 eyes)who were followed up for at least 5y after ICL V4c implantation.The observation was done before and on 1d,1mo,1 and 5y or more after the surgical procedure.The visual acuity,subjective refraction,intraocular pressure,vault,axial length,central hole position,pupil diameter,visual quality,and adverse events were analyzed.The visual quality includes aberration,the modulation transfer function cutoff frequency(MTF cutoff),objective scattering index(OSI),Stroller's ratio(SR),and visual quality questionnaire.RESULTS:The average follow-up period was 69.25±3.80mo(range 60–82mo)and the preoperative spherical equivalent(SE)was-8.66±1.97 D.At 5y after operation,the safety index was 1.01±0.02 and the efficacy index was 0.99±0.42 and SE was-0.65±0.63 D.The 59.6%of the eyes achieved an uncorrected distance visual acuity of 20/20,76.3%of the eyes had SE within±1.0 D at the last visit.The axial length increased by 0.29±0.71 mm 5y after the surgery(t=-3.843,P<0.001).The mean vault at the last follow-up was 510.59±245.61μm.The central hole was on the temporal side in 80 eyes(84.2%).The visual quality questionnaire showed that 98.2%patients were satisfied with the surgical procedure.Adverse events occurred in 4 eyes(3.5%),including the posttraumatic toric ICL rotation(2 eyes),iris incarceration(1 eye),and posttraumatic ICL displacement(1 eye)at the last follow-up.CONCLUSION:Long-term ICL V4c implantation is safe,effective,and stable for correcting moderate and to high myopia,and the visual quality with patients is excellent and satisfactory,but the progression of axial length still needs attention after surgery.
文摘Posterior capsule opacification(PCO) remains the most common complication of pediatric cataract surgery despite continuous efforts to reduce its incidence. For this reason, pediatric cataract surgeons have expended considerable effort into preventing and mitigating PCO. The intraocular lens(IOL) optic capture technique has been used for the prevention of PCO after pediatric cataract surgery for more than 20 y, but there is still no professional consensus. However, recent research has shown encouraging results. The IOL optic capture technique can be performed without anterior vitrectomy to prevent PCO, even in younger children. The type and characteristics of IOLs used for optic capture technique, the location of IOL and the complications of IOL optic capture in children are here reviewed.
文摘AIM: To evaluate human lens epithelium cell apoptosis and epithelial to mesenchymal transition (EMT) induced by femtosecond laser in femtosecond laser assisted cataract surgery (FLACS). METHODS: Sixty cataract patients with N2 to N3 stage according to the LOCS III were enrolled in this study and divided into three groups randomly: FLACSl group (cataract surgery by FLACS with LenSx), FLACS2 group (cataract surgery by FLACS with LensAR) and manual group (cataract surgery by phacoemulsification). Patients in two FLACS groups performed anterior capsulotomy by LenSx or LensAR laser system. Patients in the manual group were performed continuous curvilinear capsulorrhexis (CCC) manually. The anterior capsules were fixed right after moved out of eye. Hematoxylin-eosine staining, immunofluorescence staining and real-time PCR were performed in order to observe human lens epithelium cells changes after cataract surgery. RESULTS: The capsule cutting edge was shown irregularity and roughness in two FLACS groups and smooth edge in manual capsulotomy by pathologic staining. Irregularities of the cell configuration with partly swollen and destroyed nuclei were observed in two FLACS groups. Femtosecond laser could induce a significantly higher cell apoptosis in human lens epithelium cell than manually performed CCC (P〈0.05). Lens epithelium cells apoptosis were correlated with femtosecond laser duration according to Pearson correlation analysis. Decreased N-cadherin expression, alpha-SMA and FSP-1 level in two FLACS groups showed the inhibition of cell EMT. CONCLUSION: Femtosecond laser may affect the apoptosis and EMT of lens epithelium cells which are under the peeled central lens capsule.
文摘At present, the incidence of infectious endophthalmitis after cataract surgery has been significantly reduced, but it is still a serious complication. Removal or not of the intraocular lens(IOL) during vitrectomy in cases with a moderate or severe inflammation is controversial. In order to call upon more discussion, we publish the article entitled “Timely vitrectomy without intraocular lens removal for acute endophthalmitis after cataract surgery” written by Guo et al in this issue. With recent advanced vitrectomy techniques, and critical measures for management of risk factors related to occurrence of infection, IOL remaining during timely vitrectomy for acute endophthalmitis can possibly be safe and effective in selected cases.
基金Supported by the Beijing Municipal Science&Technology Commission,People’s Republic and Capital Clinical Characteristic Application Research Project(No.Z151100004015073)
文摘AIM: To evaluate the safety of therapeutic bandage contact lens for post-cataract surgery patients and to illustrate its efficacy on post-operative comfort and tear-film stability. METHODS: A total of 40 participants were recruited and randomly divided into two groups. Group one was instructed to wear bandage contact lenses for a week and use antibiotic eye drops for a month since the first day after surgery. Group two received sub-conjunctival injection of tobramycin and was asked to wear eye pads on the first day after surgery and then were instructed to use antibiotic eye drops as the first group did. Ocular surface disease index(OSDI) questionnaire, slit-lamp microscope examination of tear break-up time(TBUT), corneal fluorescein score(CFS), tear meniscus height(TMH) together with anterior segment optical coherence tomography(AS-OCT) and corneal topography were evaluated preoperatively and postoperatively. RESULTS: The subjective feeling(P=0.004), TBUT(P〈0.001) and TMH(P=0.02) post-surgery had improved in patients who used bandage contact lenses compared with those who did not at 1wk post-surgery. Until three month postoperatively, the comfort degree(P=0.004) and TMH(P=0.01) of group two were still worse than group one. Moreover, TBUT(P〈0.001) and CFS(P=0.004) of the group with eye pads got worse than the results before, whereas the group with bandage contact lenses recovered to normal. None of these patients had infections or other complications. CONCLUSION: Wearing therapeutic bandage contact lens after cataract surgery, compared with traditional eye-pads, is a safe method to improve tear-film stability and reduce post-operative discomfort without hindering corneal incision recovery.
文摘AIM: To evaluate the effect of femtosecond laser-assisted lens surgery(FLALS;cataract surgery or refractive lens exchange) on the structure of the optic nerve head and the macula.METHODS: This prospective longitudinal study included healthy eyes undergoing FLALS. Eyes with glaucoma or any other ocular disease that could alter optical coherence tomography results were excluded. Retinal nerve fiber layer(RNFL), Bruch’s membrane opening-minimum rim width(BMO-MRW) and macular thickness(MT) were measured preoperatively, 1 and 6 mo after surgery using spectral-domain optical coherence tomography(SD-OCT). Changes between preoperative and postoperative values were evaluated.RESULTS: A total of 87 eyes of 46 patients were included in this study. Preoperative RNFL, BMO-MRW and MT in microns(μm) were 100.77±10.39, 330.31±49.99 and 276.30±33.39, respectively. Postoperative RNFL, BMO-MRW and MT were 104.74±11.55, 348.32±54.05 and 279.83±22.65 1 mo after surgery and 102.93±11.17, 343.11±53.4 and 278.90±22.19 6 mo after surgery, respectively;which equals an increase of 3.93%, 5.45% and 1.27%,respectively, 1 mo after surgery, and 2.14%, 3.87% and 0.94% 6 mo after surgery. The differences between the preoperative and the postoperative RNFL and BMO-MRW values were statistically significant(P<0.001). Regarding MT values, there were not statistically significant differences(P=0.26).CONCLUSION: Our study suggests that FLALS does not have a negative impact on the structural status of the optic nerve head in healthy eyes, assessed by SD-OCT. There is a slight increase in the values of RNFL, BMO-MRW and MT 1 mo and 6 mo after surgery.
文摘Introduction: To report by using topical anesthesia for standing phacoemulsification and intraocular lens implantation for two patients who need cataract extraction but unable to lie flat with marked cervical kyphosis due to long-standing ankylosing spondylitis and chronic uveitis. Methods: Two patients are unable to lie flat respectively during phacoemulsification underwent this technique in Jingdong and Tonghai county Hospital of Yunnan province in China. Each patient was positioned erect or semirecumbent in a standard reclining cataract surgical chair. The ceiling-mounted microscope was rotated 60 degrees from the vertical to point toward the patient. Results: The intraoperative and postoperative periods were uneventful in two patients, with good visual outcomes after surgery. Conclusion: This technique is valuable for situations where the patient requires upright positioning because of the inability to recline flat, and should be considered for cases where standard surgical positioning is not possible.
文摘AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent bimanual microincision cataract surgery(B-MICS).METHODS:Eighty eyes which underwent cataract surgery using B-MICS technique performed by the same experienced surgeon were included in the study:40 eyes were implanted with an Incise?MJ14 IOL through a 1.4 mm CCI(group A)without enlargement of the main CCI,while 40 eyes were implanted with an Akreos?MI60 IOL with enlargement of the main CCI to 1.8 mm(group B).Best corrected visual acuity(BCVA),astigmatism and endothelial cell loss were evaluated before and after surgery at 7,30d and 6mo.Anterior segment-optical coherence tomography(AS-OCT)of CCI was performed at 1,3,7,30d,6 and 18mo.PCO incidence was evaluated at 18mo using EPCO 2000 Software.RESULTS:Mean BCVA improvement and endothelial cell loss were statistically significant at 18mo in both groups with no difference between the two groups;no statistically significant difference in surgically induced astigmatism(SIA)was noticed in the two groups.At AS-OCT the only significant alterations in the CCI were endothelial gaping and local detachment of Descemet’s membrane at 1 and 7d after surgery;no statistically significant alterations were found at 1,6 and 18mo.PCO score at 18mo was 0.03±0.07for group A and 0.08±0.18 for group B(P=0.11)with no sign of central optic plate invasion in both groups.CONCLUSION:The implant of the new Incise?MJ14 IOL through a 1.4 mm CCI and B-MICS technique appeared to be a safe and effective procedure with rapid visual recovery.PCO rate resulted very low and the CCI presented few morphological alterations which were only detectable in the first days postoperatively and achieved fast corneal healing during the long-term follow-up.
文摘Many organisms have evolved an approximately 24-hour circadian rhythm that allows them to achieve internal physiological homeostasis with external environment.Suprachiasmatic nucleus(SCN) is the central pacemaker of circadian rhythm,and its activity is entrained to the external light-dark cycle.The SCN controls circadian rhythm through regulating the synthesis of melatonin by pineal gland via a multisynaptic pathway.Light,especially shortwavelength blue light,is the most potent environmental time cue in circadian photoentrainment.Recently,the discovery of a novel type of retinal photoreceptors,intrinsically photosensitive retinal ganglion cells,sheds light on the mechanism of circadian photoentrainment and raises concerns about the effect of ocular diseases on circadian system.With age,light transmittance is significantly decreased due to the aging of crystalline lens,thus possibly resulting in progressive loss of circadian photoreception.In the current review,we summarize the circadian physiology,highlight the important role of light in circadian rhythm regulation,discuss about the correlation between age-related cataract and sleep disorders,and compare the effect of blue light-filtering intraocular lenses(lOLs) and ultraviolet only filtering lOLs on circadian rhythm.
文摘【正】Dear Sir,Iam Yong-Sun Ahn,from the Department of Ophthalmology of St.Vincent Hospital of Suwon,Kyungki-do,South Korea.Cataracts are a common problem in eyes with a glaucoma drainage device(GDD),because tube shunt surgery increases the incidence and progression of cataracts[1].An Ahmed valve,the most commonly inserted GDD,is composed of a silicone tube connected to a flat plate sewn to the sclera,and aqueous humor flows from the
文摘Background:Femtosecond laser astigmatic keratotomy(FSAK)and toric intraocular lens(IOL)implantation have been studied individually for comparison to treat astigmatism at cataract surgery.We report a case of surgically induced high corneal astigmatism by laser thermal keratoplasty(LTK)in a patient with cataract who was successfully treated with simultaneous combination of FSAK and toric IOL implantation with femtosecond laser-assisted cataract surgery(FLACS).This is the first report of both procedures combined simultaneously,with or without history of LTK.Case Description:A 68-year-old male presented with a history of LTK with two enhancements each eye in 2004,with subsequent surgically induced high corneal astigmatism,and with age-related nuclear cataract of both eyes.IOL master demonstrated+7.71 diopters of astigmatism at 163 degree right eye and+3.29 diopters of astigmatism at 4 degree left eye.After extensive discussion of the risks and benefits,the patient agreed to undergo FLACS with FSAK with two 61 degrees of relaxation incisions(RIs)and toric IOL(Alcon SN6AT9)right eye;FLACS with toric IOL(Alcon SN6AT7)alone left eye.At 2-year follow-up,uncorrected visual acuity was 20/30 right eye,20/25 left eye.His best corrected visual acuity was 20/25(+0.25+1.00 axis 21)right eye and 20/20(plano+0.25 axis 90)left eye;his best corrected near visual acuity was J1+with add+2.50 diopters right eye and left eye.Conclusions:Patients with age-related cataract and LTK induced high corneal astigmatism can hardly be sufficiently treated with FSAK or toric IOL alone at the time of cataract surgery.An effective way is to combine large FSAK and toric IOL of the highest cylindrical power of T9,in our case,simultaneously,which can achieve an excellent long term visual outcome.
基金Supported by NIH Center Core,No.P30EY014801Research to Prevent Blindness Unrestricted Grant,Department of Defense,No.DOD-Grant#W81XWH-09-1-0675
文摘AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who received sulcus-placed SPA-IOLs between 2006 and 2009 were reviewed. None of the patients underwent IOL exchange. Charts of six age-matched patients who received sulcus placed 3P-IOLs were reviewed as a control group. RESULTS: Mean follow up was 16 mo for SPA-IOL and 23 mo for 3P-IOL. Five of 8 patients in the SPA-IOL group required chronic use of IOP lowering medications at final follow up. Of these, one patient needed glaucoma implant surgery for uncontrolled IOP. One patient in the 3P-IOL group used chronic aqueous suppression pre- and postoperatively. Four of eight eyes with SPAIOL were treated with chronic topical steroids and or non-steroidal anti-inflammatory drugs for cystoid macu-la edema, chronic uveitis, pigment dispersion syndrome or a combination of the above, compared to none in the control group. Mean best-corrected visual acuity was 20/35 in the SPA-IOL group and 20/47 in the 3PIOL group.CONCLUSION: Sulcus placed SPA-IOLs are associated with increased ocular morbidity. In select cases good visual acuity may be achieved. Due to postoperative rotation of sulcus placed toric SPA-IOLs stable astigmatism correction cannot be achieved. Alternative intraocular lenses should be considered when in-the-bag placement of SPA-IOL is not possible.
文摘Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number of focal points that each lens provides,which in turn leads to different visual outcomes.Familiarity of surgeons with the various characteristics of each lens is of utmost importance for accurate IOL selection to match each patient’s needs.In this review,we aim to compare the clinical outcomes after implantation of multifocal and EDOF IOLs in terms of distance,intermediate and near vision,contrast sensitivity,and reading performance.Finally,we discuss the defocus curve and the optical and photic phenomena associated with each type of IOL.
文摘Purpose:.To compare toric intraocular lens implantation(ToricIOL).with peripheral corneal relaxing incisions(PCRIs) for astigmatism correction in patients undergoing cataract surgery.Methods: 54 patients(54 eyes) with more than 0.75 diopter(D).of preexisting corneal astigmatism were classified as group A(0.75-1.50D) or group B(1.75-2.50D). The patients were randomized to undergo Toric-IOL or PCRIs in the steep axis with spherical IOL implantation..Log MAR uncorrected visual acuity(Log MAR UCVA), Log MAR best corrected vi sual acuity.(Log MAR BCVA),.error of vector(|EV|), surgery induced refraction correction.(|SIRC |),.and correction rates(CR) were measured 1 month and 6 months postoperatively.Results: At 6 months postoperatively, all 54 eyes had LogMAR BCVA≤0.2. Patients who underwent PCRIs and ToricIOL with Log MAR BCVA≤0.1 showed no significant differences in group A(P=1.00) or in group B(P=0.59). Group A showed no significant differences in Log MAR UCVA(P =0.70), |EV|(P=0.13), |SIRC|(P=0.71), and CR(P=0.56)in patients underwent PCRIs and Toric-IOL. However, group B showed significant differences in Log MAR UCVA(P <0.01), |EV|(P<0.01)), |SIRC|(P<0.01), and CR(P<0.01).The Log MAR UCVA and |EV | between 1 and 6 months showed no significant differences in patients in group A. However, in group B, they are significant differences.Conclusion:.The efficacy and stability of Toric-IOL and PCRIs were equal in low astigmatic patients..Toric-IOL achieved an enhanced effect over PCRIs in higher astigmatic patients.PCRIs had the more refractive regression than Toric-IOL in 6months.
文摘AIM:To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens(IOL)during a 12-month follow-up.METHODS:Prospective comparative study including75 eyes of 38 patients(44-70y)undergoing uneventful cataract surgery.Each patient was randomly assigned to one type of IOL,bifocal(35 eyes)or trifocal(40 eyes).Visual,refractive,and contrast sensitivity changes were evaluated in a 12-month follow-up.The binocular defocus curve was also measured at 12mo postoperatively.RESULTS:No statistically significant differences between groups were found in postoperative uncorrected and corrected distance visual acuities(P≥0.276).Postoperative corrected near visual acuity(33 cm)was significantly better in the trifocal group during all follow-up(P≤0.004)as well as 6-month uncorrected near(P=0.008)and distancecorrected near visual acuities(P=0.016)(33/40 cm).Significantly better uncorrected intermediate and distance corrected-intermediate visual acuity were found during all follow-up in the trifocal group(P〈0.001),which was consistent with differences among groups in binocular defocus curve.Differences among groups in contrast sensitivity were minimal,being only significant at 6 months for some low to medium spatial frequencies(P≤0.006).CONCLUSION:Bifocal and trifocal diffractive IOLs are able to provide an effective visual restoration which is maintained during a 12-month follow-up,with a clear benefit of the trifocal IOL for the intermediate vision.
文摘Purpose: To assess the visual outcome after implantation of the new Hydrophylic IOL type 41 B/G accommodating intraocular lens (AIOL). Methods: The presented lens was implanted during cataract surgery. All patients were offered follow-ups, allowing two postoperative measurements to be performed at 3 months and between 2020 and 2021. The mean time between lens implantation and last follow-up was 5.3 years (min. 1 year, max. 10 years). Excluded were patients with age-related macular degeneration or amblyopia. Patients with a foreign lens implanted into the second eye were included in a separate control group. Corrected distance (CDVA) and uncorrected distance visual acuity (UDVA) at 5 m, and corrected near (CNVA) and uncorrected near visual acuity (UNVA) at 40 cm were assessed. Furthermore, the postoperative spherical equivalent (SE), the dependence on spectacles and the occurrence of optical phenomena were evaluated. Results: The final study cohort consists of 65 patients with 119 implanted AIOLs. Significantly better visual results were obtained in both postoperative follow-ups compared with the preoperative results. The mean values of the last follow-up for the UNVA, CNVA, UDVA, and CDVA were 0.107 ± 0.10;0.039 ± 0.08;0.097 ± 0.11;and 0.040 ± 0.09 logMAR, respectively. Visual outcomes remained on a high level for up to 10 years and showed significantly better results compared to the control group. Postoperative SE was significantly improved. Nearly 70% of patients were no longer dependent on glasses. Furthermore, the occurrence of disturbing optical phenomena was denied by all patients. Conclusion: The results of this AIOL are particularly promising, especially since gratifying visual results could still be measured 10 years after implantation.
文摘AIM:To evaluate the clinical outcomes of V4 c implantable collamer lens(Hole ICL) implantation with regard to the optical quality assessed according to different degrees of decentering.METHODS:This included 49 eyes that received conventional ICL and 94 eyes that received Hole ICL.The eyes that received Hole ICL were divided into three groups according to the degree of decentering:group 1,central hole within 1 hole diameter(HD) from the pupil center;group 2,central hole within 1 HD to 2 HD;and group 3,central hole within 2 HD to 3 HD.Visual acuity(VA),intraocular pressure(IOP),and spherical equivalent(SE) values were assessed at 1wk,1 and 3mo after surgery.The ocular modulation transfer function,Strehl ratio,objective scattering index,and higher order aberrations(HOAs) were measured for 4-mm pupils at 3mo after surgery.RESULTS:There were no significant differences in VA,IOP,and SE among the conventional and Hole ICL groups.With regard to HOAs,values for coma and spherical aberrations showed no differences.The total HOA and trefoil values were significantly higher in group 2 than in group 1(P=0.02,0.03,respectively).There were no significant differences among groups with regard to other optical quality parameter at 3mo after surgery.CONCLUSION:Our results suggest that Hole ICL implantation provides satisfactory visual quality that is equivalent to that provided by conventional ICL,regardless of the presence of central hole and degree of decentering.
文摘AIM: To assess the outcomes of posterior chamber implantable collamer lens (ICL) implantation in Chinese pediatric patients with unilateral high myopic amblyopia.METHODS: Eleven eyes of 11 amblyopic patients aged 11.02±3.34y underwent ICL (model V4, Staar Surgical Inc.) implantation to treat unilateral anisometropia were studied. Visual acuity, cycloplegic refraction, contrast sensitivity, stereopsis, intraocular pressure (IOP), vaulting, corneal endothelial cell count and complications were evaluated. Patients completed follow-up at 3d, 1, 3mo and the last follow-up time (mean 8.18±2.82mo) after surgery.RESULTS: The mean myopic anisometropia was -13.70±3.25 D preoperatively and +0.69±2.63 D at 8mo postoperatively. The logMAR corrected distance visual acuity (CDVA) of the amblyopic eye was 1.51±0.72 preoperatively and 0.75±0.40 at 8mo postoperatively. The logMAR CDVA at 3d, 1, 3 and 8mo postoperatively improved by a mean of 0.64, 1.55, 1.82 and 2.64 lines and gained more than 2 lines accounted for 18%, 45%, 45%, 64%, respectively. The contrast sensitivity of 0.5, 1 and 2 cpd in amblyopic eyes was significantly increased after surgery. No patient had near stereopsis recovery. The vaulting at 3 and 8mo was significantly lower than that at 1mo postoperatively. No other intraoperative or postoperative complications were observed, except an acute pupillary block glaucoma happened in a patient at two weeks postoperatively.CONCLUSION: This short-term results indicate that ICL implantation can be a promising alternative therapy for high myopic anisometropic amblyopia in pediatric patients who have failed with conventional treatments and not suitable to corneal refraction surgery.