AIM:To report the clinical prognosis and pathological findings of accidental lens vacuolar changes in eyes with intraoperative exposure to a dispersive ophthalmic viscosurgical device(OVD).METHODS:Two patients who dev...AIM:To report the clinical prognosis and pathological findings of accidental lens vacuolar changes in eyes with intraoperative exposure to a dispersive ophthalmic viscosurgical device(OVD).METHODS:Two patients who developed transient lens vacuolar changes during uneventful persistent pupillary membrane(PPM)removal surgery were presented and followed up.This event was speculated to be associated with an intraoperative dispersive OVD DisCoVisc(hyaluronic acid 1.6%-chondroitin sulfate 4.0%)exposure.Then,to provide the pathological basis for our speculation,another four cataract patients were randomly exposed to different OVDs,and their anterior lens capsules were investigated with transmission electron microscopy(TEM).RESULTS:After months,the subcapsular vacuoles in both PPM cases were gradually disappeared without visual deterioration.For the cataract patients,similar lens changes were observed intraoperatively in those exposed to a dispersive DisCoVisc but not a cohesive OVD IVIZ(sodium hyaluronate gel 1.0%).In addition,marked ultrastructural changes,including chromatin condensation,extensive cytoplasmic vacuoles,and obvious intercellular space between lens epithelial cells in the anterior lens capsules of all eyes exposed to DisCoVisc,were observed by TEM.CONCLUSION:The lens vacuolar changes may be associated with a dispersive OVD exposure.Therefore,it is not preferable to use dispersive OVDs in patients with transparent lenses or without the intention of lens extraction.In addition,close follow-ups instead of immediate lens extraction are recommended for the occurrence of similar lens lesions.展开更多
Backgrounds:To assess changes in anterior segment biometry during accommodation using a swept source anterior segment optical coherence tomography(SS-OCT).Methods:One hundred-forty participants were consecutively recr...Backgrounds:To assess changes in anterior segment biometry during accommodation using a swept source anterior segment optical coherence tomography(SS-OCT).Methods:One hundred-forty participants were consecutively recruited in the current study.Each participant underwent SS-OCT scanning at 0 and−3 diopter(D)accommodative stress after refractive compensation,and ocular parameters including anterior chamber depth(ACD),anterior and posterior lens curvature,lens thickness(LT)and lens diameter were recorded.Anterior segment length(ASL)was defined as ACD plus LT.Lens central point(LCP)was defined as ACD plus half of the LT.The accommodative response was calculated as changes in total optical power during accommodation.Results:Compared to non-accommodative status,ACD(2.952±0.402 vs.2.904±0.382 mm,P<0.001),anterior(10.771±1.801 vs.10.086±1.571 mm,P<0.001)and posterior lens curvature(5.894±0.435 vs.5.767±0.420 mm,P<0.001),lens diameter(9.829±0.338 vs.9.695±0.358 mm,P<0.001)and LCP(4.925±0.274 vs.4.900±0.259 mm,P=0.010)tended to decreased and LT thickened(9.829±0.338 vs.9.695±0.358 mm,P<0.001),while ASL(6.903±0.279 vs.6.898±0.268 mm,P=0.568)did not change significantly during accommodation.Younger age(β=0.029,95%CI:0.020 to 0.038,P<0.001)and larger anterior lens curvature(β=−0.071,95%CI:−0.138 to−0.003,P=0.040)were associated with accommodation induced greater steeping amplitude of anterior lens curvature.The optical eye power at 0 and−3 D accommodative stress was 62.486±2.284 and 63.274±2.290 D,respectively(P<0.001).Age was an independent factor of accommodative response(β=−0.027,95%CI:−0.038 to−0.016,P<0.001).Conclusions:During−3 D accommodative stress,the anterior and posterior lens curvature steepened,followed by thickened LT,fronted LCP and shallowed ACD.The accommodative response of−3 D stimulus is age-dependent.展开更多
AIM: To evaluate changes in the anterior chamber depth (ACD), crystalline lens thickness (LT) and its refractive power after laser in situ keratomileusis (LASIK). METHODS: In all cases, the preoperative and postoperat...AIM: To evaluate changes in the anterior chamber depth (ACD), crystalline lens thickness (LT) and its refractive power after laser in situ keratomileusis (LASIK). METHODS: In all cases, the preoperative and postoperative central ACD which were measured with Pentacam, Orbscan, IOL-Master and A-scan ultrasonography, central corneal true net power which was measured with the Pentacam, Orbscan and IOL-Master, axial length (AL) which was measured with IOL-Master and LT which was measured with the A-scan ultrasonography were compared using the paired sample t test. Ocular refractive errors and lens refractive power at corneal plane were calculated and their correlations were also evaluated before and after LASIK. RESULTS: At 1 week after LASIK, LT and crystalline lens refractive power at corneal plane (Dlens) which were associated with the IOL-Master and Pentacam increased significantly (P <= 0.005), ACD decreased significantly (P <= 0.001), but no significant increase was observed in the Diens which was associated with the Orbscan(P=0.261). Significant correlations between the changes in the ocular refractive errors and Diens which were associated with the Pentacam were observed at 1 week and 6 months after LASIK (P = 0.028; P=0.001). CONCLUSION: LT increased significantly after LASIK, and this might partially lead to ACD decrease, Diens increase and a small quantity of myopic regression.展开更多
BACKGROUND Intravitreal injection has become an efficient approach for delivering drugs at therapeutic levels to the posterior segment in retinal diseases.However,the increased frequency and number of intravitreal inj...BACKGROUND Intravitreal injection has become an efficient approach for delivering drugs at therapeutic levels to the posterior segment in retinal diseases.However,the increased frequency and number of intravitreal injections have raised concerns about their side effects.As manipulation during surgery is relatively simple,details of the procedure are easily overlooked.Iatrogenic crystalline lens injury is a rare complication caused by improper manipulation during surgical procedures.We report two cases of crystalline lens injury during intravitreal injection of triamcinolone acetonide(TA)with the hope of providing an insight into this treatment.CASE SUMMARY Case 1 was a 62-year-old woman with macular edema caused by central retinal vein occlusion in her right eye,and Case 2 was a 65-year-old man with macular edema caused by branch retinal vein occlusion in his right eye.In view of the patients’condition and economic constraints,an intravitreal injection of TA was administered.Due to inappropriate manipulation during surgery,the lens was injured.The site of lens injury and clinical manifestations were different in the two cases.Symptomatic treatment and continuous follow-up were carried out.The therapeutic effect following phacoemulsification of the cataract was satisfactory.CONCLUSION Well-defined surgical incision under proper anesthesia,sufficient patient information and proficient anatomical skills of the physician are mandatory to prevent this rare adverse event.Careful and meticulous phacoemulsification of the cataract is suggested.展开更多
AIM: To quantify the changes in the lens profile with accommodation in different age groups. METHODS: The Pentacam HR system was used to obtain the images of the anterior eye segment from 23 young and 15 presbyopic em...AIM: To quantify the changes in the lens profile with accommodation in different age groups. METHODS: The Pentacam HR system was used to obtain the images of the anterior eye segment from 23 young and 15 presbyopic emmetropic subjects in unaccommodated (with an accommodation stimulus of 0.0D) and accommodated (with an accommodation stimulus of 5.0D for the young group and 1.0D for the presbyopic group) states. The phakic crystalline lens shape, including curvature of crystalline lens and central lens thickness (CLT), and the measurements of anterior segment length (ASL), central anterior chamber depth (CACD) were investigated. The anterior chamber volume (ACV) was also measured. RESULTS: The reduction of CACD and ACV were significant in both groups after accommodation stimulus. From the profile of anterior eye segment, a significant decrease in anterior crystalline lens radii of curvature (-2.52mm) and a mean increase in CLT (0.222mm) and ASL (0.1138mm) were found in the. young group with an accommodation stimulus of 5.0D. However, no statistically significant changes of CLT, ASL, or crystalline lens radii of curvature were found in the presbyopic group. CONCLUSION: Our data showed that the shallowing of anterior chamber during accommodation was caused by the forward bulging of the anterior lens surface, rather than by anterior shifting of lens position in either young or presbyopic subjects.展开更多
Dear Editor,I write to present the results of a study on the correlation between the ultrasound energy consumed during phacoemulsification with various preoperative parameters,including best corrected distance visual ...Dear Editor,I write to present the results of a study on the correlation between the ultrasound energy consumed during phacoemulsification with various preoperative parameters,including best corrected distance visual acuity(BCDVA),the signal to noise ratio(SNR)obtained by partial coherence laser interferometry and primarily,lens spikes measurements derived by A-scan ultrasound biometry.Quantification of crystalline lens hardness before cataract removal has been attempted by several researchers in the past.These have been in humans and in animals,in vivo and in vitro,and have used a variety of imaging modalities.展开更多
Background: We sought to verify the efficacy and safety of transconjunctival 23-gauge pars plana vitrectomy (PPV) alone by our bimanual technique for the removal of dense posteriorly dislocated crystalline lens. Metho...Background: We sought to verify the efficacy and safety of transconjunctival 23-gauge pars plana vitrectomy (PPV) alone by our bimanual technique for the removal of dense posteriorly dislocated crystalline lens. Methods: A retrospective, noncomparative, interventional study of 31 consecutive cases of patients who underwent 23-gauge PPV alone for the removal of dense posteriorly dislocated crystalline lens following complicated cataract surgeries using our bimanual technique was conducted. The main outcomes measured included best-corrected visual acuity (BCVA), preoperative intraocular pressure (IOP), postoperative IOP and postoperative complications. Results: In all 31 cases included in this study, those dense posteriorly dislocated crystalline lenses were successfully removed. The enrolled patients consisted of 17 males and 14 females with a mean age of (75.84 ± 6.17) years (range 59 - 90). The mean follow-up length was (7.61 ± 1.87) months with a range of 6 months to 1 year. The mean preoperative BCVA was 0.22 ± 0.11 logMAR system, and the postoperative BCVA was 0.33 ± 0.07 logMAR system after 6 months of follow-up. The mean operative time was 46.32 ± 4.80 minutes with a range of 38.00 to 57.00 minutes. All of the conjunctival incisions self-closed within the first week with no wound leakage or hemorrhage. The postoperative complications were relatively rare. Conclusions: The removal of dense posteriorly dislocated crystalline lens might be a challenge for micro-incision vitrectomy. Our bimanual technique was proved to be an effective and safe method for those particular dense lenses using 23-gauge alone.展开更多
AIM:To investigate auto-cortex of crystalline lens induced iris neovascularization (INV). METHODS: Thirty-six eyes of 36 guinea-pigs were included and divided into three groups randomly in this cohort study. Group A: ...AIM:To investigate auto-cortex of crystalline lens induced iris neovascularization (INV). METHODS: Thirty-six eyes of 36 guinea-pigs were included and divided into three groups randomly in this cohort study. Group A: the right lens nucleus was extracted and the remaining cortical lens material was aspirated thoroughly.. Group B: the lens was removed and 30 mu L precipitated lens cortex was injected into the anterior chamber again. Group C: aspirated the lens cortex of the left eyes and inject them into the right anterior chambers about 10 mu L. Clinical changes were followed by slit-lamp examination and photograph. The eye balls were enucleated at the day of 2, 4, 7, 11, 13, 17 after operation. HE was used to detect the pathological changes. ' RESULTS:Group A:INV had not been observed until the end of empirical study. The stromal layer contained thick wall vessels, without expansion. Group B: All eyes developed INV. Postoperative (po) 7 days; the eyes developed intense and extensive INV. The vessels of iris expanded remarkably and neovascularization was observed erupting from it's lateral wall and stretching towards the anterior surface. Poll days, INV regressed gradually after lens cortex had been absorbed. Group C: Po four (4) days, new blood vessels liking red line were presented on the anterior surface of the iris and they were not obvious. CONCLUSION: Anterior chamber inside lens coriaceous can induce iris new blood vessels.展开更多
AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ...AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications.展开更多
AIM:To observe early clinical outcome with lens position adjustment following the implantable collamer lens(ICL)surgery.METHODS:Sixty patients were selected for this retrospective study.One eye from each patient recei...AIM:To observe early clinical outcome with lens position adjustment following the implantable collamer lens(ICL)surgery.METHODS:Sixty patients were selected for this retrospective study.One eye from each patient received Toric ICL for astigmatism correction,and the other received non-astigmatic ICL surgery using horizontal position.Patients with higher postoperative arch height were selected,and their non-astigmatic eye clinical outcome were observed after ICL surgery at 1wk,1,and 3mo.The clinical measurements included uncorrected visual acuity(UCVA),intraocular pressure(IOP),refractive state,corneal endothelium cell count,and arch height.Three months later,the ICL in each patient’s non-astigmatic eye was adjusted to the vertical from the horizontal position.The results were compared before and 1wk,1,and 3mo after adjustment.RESULTS:UCVA and IOP were significantly reduced 1wk after position adjustment compared to 1wk after ICL implantation(P<0.05).The patients demonstrated significantly reduced arch height and corneal endothelium cell count 1wk,1,and 3mo after adjusting position compared to 1wk,1,and 3mo after ICL implantation(P<0.05).However,there was no significant difference in refraction between 1wk,1,and 3mo after ICL implantation and position adjustment(P>0.05).CONCLUSION:Early positioning adjustment postphakic ICL implantation can benefit patients with adjusted arch height or higher IOP.Despite the good clinical effects,the doctors should pay attention to the potential for adverse effects on UCVA and corneal endothelium cells following early position adjustment after posterior chamber phakic ICL implantation.展开更多
The effects of the gravitational redshift of gravitons upon spiral galaxy rotation energy are compared to the standard mass to light analyses in obtaining rotation curves. The derivation of the total baryonic matter c...The effects of the gravitational redshift of gravitons upon spiral galaxy rotation energy are compared to the standard mass to light analyses in obtaining rotation curves. The derivation of the total baryonic matter compares well with the standard theory and the rotation velocity is matched to a high precision. The stellar mass distributions obtained from the fit with graviton energy loss are used to derive the surface brightness magnitudes for the galaxies, which agree well with the observed measurements. In a new field of investigation, the graviton theory is applied to the observations of gravitational lenses. The results of these applications of the theory suggest that it can augment the standard methods and may eliminate the need for dark matter.展开更多
Carbon nitrides with two-dimensional layered structures and high theoretical capacities are attractive as anode materials for sodium-ion batteries while their low crystallinity and insufficient structural stability st...Carbon nitrides with two-dimensional layered structures and high theoretical capacities are attractive as anode materials for sodium-ion batteries while their low crystallinity and insufficient structural stability strongly restrict their practical applications.Coupling carbon nitrides with conductive carbon may relieve these issues.However,little is known about the influence of nitrogen(N)configurations on the interactions between carbon and C_(3)N_(4),which is fundamentally critical for guiding the precise design of advanced C_(3)N_(4)-related electrodes.Herein,highly crystalline C_(3)N_(4)(poly(triazine imide),PTI)based all-carbon composites were developed by molten salt strategy.More importantly,the vital role of pyrrolic-N for enhancing charge transfer and boosting Na+storage of C_(3)N_(4)-based composites,which was confirmed by both theoretical and experimental evidence,was spot-highlighted for the first time.By elaborately controlling the salt composition,the composite with high pyrrolic-N and minimized graphitic-N content was obtained.Profiting from the formation of highly crystalline PTI and electrochemically favorable pyrrolic-N configurations,the composite delivered an unusual reverse growth and record-level cycling stability even after 5000 cycles along with high reversible capacity and outstanding full-cell capacity retention.This work broadens the energy storage applications of C_(3)N_(4) and provides new prospects for the design of advanced all-carbon electrodes.展开更多
Chitin is the second most abundant renewable polysaccharide on Earth.The degradation of chitin into soluble and bioactive N-acetyl chitooligosaccharides(NCOSs)and N-acetyl-D-glucosamine(GlcNAc)has emerged as a pivotal...Chitin is the second most abundant renewable polysaccharide on Earth.The degradation of chitin into soluble and bioactive N-acetyl chitooligosaccharides(NCOSs)and N-acetyl-D-glucosamine(GlcNAc)has emerged as a pivotal step in the efficient and sustainable utilization of chitin resources.However,because of its dense structure,high crystallinity,and poor solubility,chitin typically needs pretreatment via chemical,physical,and other methods before enzymatic conversion to enhance the accessibility between substrates and enzyme molecules.Consequently,there has been considerable interest in exploring the direct biological degradation of crystalline chitin as a cost-effective and environment-friendly technology.This review endeavors to present several biological methods for the direct degradation of chitin.We primarily focused on the importance of chitinase containing chitin-binding domain(CBD).Additionally,various modification strategies for increasing the degradation efficiency of crystalline chitin were introduced.Subsequently,the review systematically elucidated critical components of multi-enzyme catalytic systems,highlighting their potential for chitin degradation.Furthermore,the application of microorganisms in the degradation of crystalline chitin was also discussed.The insights in this review contribute to the explorations and investigations of enzymatic and microbial approaches for the direct degradation of crystalline chitin,thereby fostering advancements in biomass conversion.展开更多
AIM:To investigate the biocompatibility and bacterial adhesion properties of light responsive materials(LRM)and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular le...AIM:To investigate the biocompatibility and bacterial adhesion properties of light responsive materials(LRM)and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular lenses(AIOLs).METHODS:Employing fundamental experimental research techniques,LRM with human lens epithelial cells(hLECs)and human retinal pigment epithelium cells(ARPE-19 cells)were co-cultured.Commercially available intraocular lenses(IOLs)were used as controls to perform cell counting kit-8(CCK-8),cell staining under varying light intensities,cell adhesion and bacterial adhesion experiments.RESULTS:LRM exhibited a stronger inhibitory effect on the proliferation of ARPE19 cells than commercially available IOLs when co-cultured with the undiluted extract for 96h(P<0.05).Under other culturing conditions,the effects on the proliferation of hLECs and ARPE-19 cells were not significantly different between the two materials.Under the influence of light irradiation at intensities of 200 and 300 mW/cm^(2),LRM demonstrated a markedly higher inhibitory effect on the survival of hLECs compared to commercially available IOLs(P<0.0001).They also showed a stronger suppressive effect on the survival rate of ARPE-19 cells,with significant differences observed at 200 mW/cm^(2)(P<0.001)and extremely significant differences at 300 mW/cm^(2)(P<0.0001).Additionally,compared to commercially available IOLs,LRM had a higher number of cells adhering to their surface(P<0.05),as well as a significantly greater number of adherent bacterium(P<0.0001).CONCLUSION:LRM,characterized by their excellent non-contact tunable deformability and low cytotoxicity to ocular tissues,show considerable potential for use in the fabrication of AIOLs.These materials demonstrate strong cell adhesion;however,during photothermal conversion processes involving shape deformation under various light intensities,the resultant temperature rise may harm surrounding cells.These factors suggest that while the material plays a positive role in reducing the incidence of posterior capsule opacification(PCO),it also poses potential risks for retinal damage.Additionally,the strong bacterial adhesion of these materials indicates an increased risk of endophthalmitis.展开更多
AIM:To establish an animal model of form deprivation amblyopia based on a simulated cataract intraocular lens(IOLs).METHODS:Poly(dimethyl siloxane)-SiO_(2) thin films(PSF)with different degrees of opacity as IOL mater...AIM:To establish an animal model of form deprivation amblyopia based on a simulated cataract intraocular lens(IOLs).METHODS:Poly(dimethyl siloxane)-SiO_(2) thin films(PSF)with different degrees of opacity as IOL materials were prepared.The light transmission of the PSF-IOL was measured,and its in vitro biosafety was determined by cell counting kit(CCK)-8 assay using the HLEC-B3 cell line and ARPE-19 cell line.Subsequently,the in vivo safety was determined by implanting the PSF-IOL with 10%wt SiO_(2) into the right eyes of New Zealand white rabbits(PSF-IOL group),and compared with two control groups:contralateral comparison group and normal control(NC)group(Contralateral comparison group:the fellow eye;NC group:a group of binocular normal rabbits without intervention).The flash visual-evoked potentials(F-VEPs)were measured to verify amblyopia.RESULTS:PSFs containing 0,2%,and 10%wt SiO_(2) were successfully constructed.The 0 SiO_(2) PSF was transparent,while the 10%wt SiO_(2) PSF was completely opaque.It was found that PSF did not induce unwanted cytotoxicity in HLECs and ARPE19 cells in vitro.In vitro,PSF-IOL with 10%wt SiO_(2) was also non-toxic,and no significant inflammation or structural changes occurred after four weeks of PSF-IOL implantation.Finally,our IOL-simulated congenital cataract rabbit detected by F-VEPs suggested tentative amblyopia.CONCLUSION:A PSF-IOL that mimics cataracts is created.A novel form deprivation model is created by the IOL-simulated congenital cataract rabbit.It can be developed fast and stable and holds great potential for future study.展开更多
AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants ...AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants underwent ICL surgery and were divided into the low(<250μm)and normal(250-1000μm)vault groups based on the postoperative vault at 3mo.The preoperative biometric parameters and clinical outcomes were compared between the two groups.The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations.RESULTS:Sixteen(23 eyes)and 36 patients(63 eyes)were in the low and normal vault groups,respectively.All implantation procedures were uneventful with no cataract formation in the early postoperative period.The sulcusto-sulcus lens rise(STSL)and iris ciliary angle(ICA)were correlated with vault at 3mo after surgery.Every 0.1 mm increase in STSL was associated with 38.9μm decrease in the postoperative 3-month vault.A rise of 1 degree in ICA is associated with a reduction of 4μm in vault.CONCLUSION:Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation,suggesting a need for adjustments to the ICL size in these patients.Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery.展开更多
By including certain point group symmetry in the classification of band topology,Fu proposed a class of threedimensionaltopological crystalline insulators(TCIs)without spin-orbit coupling in 2011.In Fu’s model,surfac...By including certain point group symmetry in the classification of band topology,Fu proposed a class of threedimensionaltopological crystalline insulators(TCIs)without spin-orbit coupling in 2011.In Fu’s model,surface states(ifpresent)doubly degenerate atГandM when time-reversal and C_(4) symmetries are preserved.The analogs of Fu’s modelwith surface states quadratically degenerate atM are widely studied,while surface states with quadratic degeneracy atГare rarely reported.In this study,we propose a three-dimensional TCI without spin-orbit coupling in a judiciously designednonsymmorphic photonic metacrystal.The surface states of photonic TCIs exhibit quadratic band degeneracy in the(001)surface Brillouin zone(BZ)center(Гpoint).The gapless surface states and their quadratic dispersion are protected by C4and time-reversal symmetries,which correspond to the nontrivial band topology characterized by Z_(2)topological invariant.Moreover,the surface states along lines fromГto the(001)surface BZ boundary exhibit zigzag feature,which is interpretedfrom symmetry perspective by building composite operators constructed by the product of glide symmetries with timereversalsymmetry.The metacrystal array surrounded with air possesses high order hinge states with electric fields highlylocalized at the hinge that may apply to optical sensors.The gapless surface states and hinge states reside in a cleanfrequency bandgap.The topological surface states emerge at the boundary of the metacrystal and perfect electric conductor(PEC),which provide a pathway for topologically manipulating light propagation in photonic devices.展开更多
The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract sur...The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract surgery in diabetic patients poses many challenges:Poor epithelial healing,decreased corneal sensitivity,increased central corneal thickness,decreased endothelial cell count,variable topography,poor pupillary dilatation,anterior capsular phimosis,posterior capsular opacification(PCO),chances of progression of diabetic retinopathy(DR),zonular weakness,and vitreous prolapse and diabetic macular edema.Selection of an appropriate intraocular lens(IOL)is crucial for visual rehabilitation and monitoring DR.The choice of IOL in diabetic cataract patients is a challenging scenario.Square-edge IOLs are favored for their capacity to mitigate PCO,whereas hydrophilic counterparts may incur calcification in the setting of proliferative DR.The advisability of premium IOLs for achieving spectacle independence warrants judicious evaluation,particularly in the presence of advanced retinopathy.Optimal IOL placement within the capsular bag is advocated to minimize postoperative complications.Rigorous preoperative assessment and informed patient counseling regarding IOL options are indispensable for optimizing surgical outcomes.This review article covers various aspects regarding the choice of IOLs in different case scenarios and complications in the diabetic population.展开更多
In this paper,high-energy Ne ions were used to irradiate Zr_(63.5)Cu_(23)Al_(9)Fe_(4.5) metallic glass(MG)and crystalline W to investigate their difference in mechanical response after irradiation.The results showed t...In this paper,high-energy Ne ions were used to irradiate Zr_(63.5)Cu_(23)Al_(9)Fe_(4.5) metallic glass(MG)and crystalline W to investigate their difference in mechanical response after irradiation.The results showed that with the irradiation dose increased,the tensile micro-strain increased,nano-hardness increased from 7.11 GPa to 7.90 GPa and 8.62 GPa,Young’s modulus increased,and H3/E2 increased which indicating that the plastic deformability decreased in crystalline W.Under the same irradiation conditions,the Zr_(63.5)Cu_(23)Al_(9)Fe_(4.5) MG still maintained the amorphous structure and became more disordered despite the longer range and stronger displacement damage of Ne ions in Zr_(63.5)Cu_(23)Al_(9)Fe_(4.5) MG than in crystalline W.Unlike the irradiation hardening and embrittlement behavior of crystalline W,Zr_(63.5)Cu_(23)Al_(9)Fe_(4.5) MG showed the gradual decrease in hardness from 6.02 GPa to 5.89 GPa and 5.50 GPa,the decrease in modulus and the increase in plastic deformability with the increasing dose.Possibly,the irradiation softening and toughening phenomenon of Zr_(63.5)Cu_(23)Al_(9)Fe_(4.5) MG could provide new ideas for the design of nuclear materials.展开更多
AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defoc...AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defocus profile in young adults.METHODS:Seventeen young adults(2 males and 15 females;age 23.17±4.48y)were randomly assigned to wear two designs binocularly with a one-week washout period in between.Total of four MFGPCL designs were assessed.All designs were distance-center that varied in two add power(+1.50 and 3.00 D)and/or two distance zone(DZ)diameters(1.50 and 3.00 mm;design A:DZ 1.5/add 3.0,B:DZ 1.5/add 1.5,C:DZ 3.0/add 3.0,D:DZ 3.0/add 1.5).ChT,AL,and peripheral refraction data were collected on each subject at baseline,on days 1 and 7 of MFGPCL daily wear.ChT was assessed in four quadrants using a spectraldomain optical coherence tomography.RESULTS:AL was shortened by-26±44μm with lens C,-18±27μm with lens D,-13±29μm with lens A,and-8±30μm with lens B(all P<0.05).A significant overall increase in ChT was observed with all 4 designs(lens A:+6±6μm,B:+3±7μm,C:+8±7μm,and D:+8±7μm).Temporal and superior choroid exhibited more choroidal thickening associated with MFGPCL.All designs induced significant relative peripheral myopia(RPM)beyond the central 20o across the horizontal meridian in both nasal and temporal fields(P<0.05).CONCLUSION:MFGPCLs show a significant influence on ChT and AL,which are associated with significant increase in RPM after short-term wear.The reliability and feasibility of quantifying short-term changes in ChT support its use as a promising marker for the long-term efficacy of myopia-controlling treatments.展开更多
基金Supported by the National Key R&D Program of China(No.2020YFC2008200)the National Natural Science Foundation of China(No.81970778,No.82271066,No.81970813)+1 种基金the Natural Science Foundation of Guangdong Province(No.2023A1515011198)Guangzhou Municipal Science and Technology Project(No.SL2022A03J00553).
文摘AIM:To report the clinical prognosis and pathological findings of accidental lens vacuolar changes in eyes with intraoperative exposure to a dispersive ophthalmic viscosurgical device(OVD).METHODS:Two patients who developed transient lens vacuolar changes during uneventful persistent pupillary membrane(PPM)removal surgery were presented and followed up.This event was speculated to be associated with an intraoperative dispersive OVD DisCoVisc(hyaluronic acid 1.6%-chondroitin sulfate 4.0%)exposure.Then,to provide the pathological basis for our speculation,another four cataract patients were randomly exposed to different OVDs,and their anterior lens capsules were investigated with transmission electron microscopy(TEM).RESULTS:After months,the subcapsular vacuoles in both PPM cases were gradually disappeared without visual deterioration.For the cataract patients,similar lens changes were observed intraoperatively in those exposed to a dispersive DisCoVisc but not a cohesive OVD IVIZ(sodium hyaluronate gel 1.0%).In addition,marked ultrastructural changes,including chromatin condensation,extensive cytoplasmic vacuoles,and obvious intercellular space between lens epithelial cells in the anterior lens capsules of all eyes exposed to DisCoVisc,were observed by TEM.CONCLUSION:The lens vacuolar changes may be associated with a dispersive OVD exposure.Therefore,it is not preferable to use dispersive OVDs in patients with transparent lenses or without the intention of lens extraction.In addition,close follow-ups instead of immediate lens extraction are recommended for the occurrence of similar lens lesions.
基金the National Natural Science Foundation of China(Nos.81770905 and 81873675)the Construction Project of High-Level Hospitals in Guangdong Province(No.303020102).
文摘Backgrounds:To assess changes in anterior segment biometry during accommodation using a swept source anterior segment optical coherence tomography(SS-OCT).Methods:One hundred-forty participants were consecutively recruited in the current study.Each participant underwent SS-OCT scanning at 0 and−3 diopter(D)accommodative stress after refractive compensation,and ocular parameters including anterior chamber depth(ACD),anterior and posterior lens curvature,lens thickness(LT)and lens diameter were recorded.Anterior segment length(ASL)was defined as ACD plus LT.Lens central point(LCP)was defined as ACD plus half of the LT.The accommodative response was calculated as changes in total optical power during accommodation.Results:Compared to non-accommodative status,ACD(2.952±0.402 vs.2.904±0.382 mm,P<0.001),anterior(10.771±1.801 vs.10.086±1.571 mm,P<0.001)and posterior lens curvature(5.894±0.435 vs.5.767±0.420 mm,P<0.001),lens diameter(9.829±0.338 vs.9.695±0.358 mm,P<0.001)and LCP(4.925±0.274 vs.4.900±0.259 mm,P=0.010)tended to decreased and LT thickened(9.829±0.338 vs.9.695±0.358 mm,P<0.001),while ASL(6.903±0.279 vs.6.898±0.268 mm,P=0.568)did not change significantly during accommodation.Younger age(β=0.029,95%CI:0.020 to 0.038,P<0.001)and larger anterior lens curvature(β=−0.071,95%CI:−0.138 to−0.003,P=0.040)were associated with accommodation induced greater steeping amplitude of anterior lens curvature.The optical eye power at 0 and−3 D accommodative stress was 62.486±2.284 and 63.274±2.290 D,respectively(P<0.001).Age was an independent factor of accommodative response(β=−0.027,95%CI:−0.038 to−0.016,P<0.001).Conclusions:During−3 D accommodative stress,the anterior and posterior lens curvature steepened,followed by thickened LT,fronted LCP and shallowed ACD.The accommodative response of−3 D stimulus is age-dependent.
文摘AIM: To evaluate changes in the anterior chamber depth (ACD), crystalline lens thickness (LT) and its refractive power after laser in situ keratomileusis (LASIK). METHODS: In all cases, the preoperative and postoperative central ACD which were measured with Pentacam, Orbscan, IOL-Master and A-scan ultrasonography, central corneal true net power which was measured with the Pentacam, Orbscan and IOL-Master, axial length (AL) which was measured with IOL-Master and LT which was measured with the A-scan ultrasonography were compared using the paired sample t test. Ocular refractive errors and lens refractive power at corneal plane were calculated and their correlations were also evaluated before and after LASIK. RESULTS: At 1 week after LASIK, LT and crystalline lens refractive power at corneal plane (Dlens) which were associated with the IOL-Master and Pentacam increased significantly (P <= 0.005), ACD decreased significantly (P <= 0.001), but no significant increase was observed in the Diens which was associated with the Orbscan(P=0.261). Significant correlations between the changes in the ocular refractive errors and Diens which were associated with the Pentacam were observed at 1 week and 6 months after LASIK (P = 0.028; P=0.001). CONCLUSION: LT increased significantly after LASIK, and this might partially lead to ACD decrease, Diens increase and a small quantity of myopic regression.
基金Supported by Scientific Research Projects of Shanghai Municipal Health and Family Planning Commission,No.201640049
文摘BACKGROUND Intravitreal injection has become an efficient approach for delivering drugs at therapeutic levels to the posterior segment in retinal diseases.However,the increased frequency and number of intravitreal injections have raised concerns about their side effects.As manipulation during surgery is relatively simple,details of the procedure are easily overlooked.Iatrogenic crystalline lens injury is a rare complication caused by improper manipulation during surgical procedures.We report two cases of crystalline lens injury during intravitreal injection of triamcinolone acetonide(TA)with the hope of providing an insight into this treatment.CASE SUMMARY Case 1 was a 62-year-old woman with macular edema caused by central retinal vein occlusion in her right eye,and Case 2 was a 65-year-old man with macular edema caused by branch retinal vein occlusion in his right eye.In view of the patients’condition and economic constraints,an intravitreal injection of TA was administered.Due to inappropriate manipulation during surgery,the lens was injured.The site of lens injury and clinical manifestations were different in the two cases.Symptomatic treatment and continuous follow-up were carried out.The therapeutic effect following phacoemulsification of the cataract was satisfactory.CONCLUSION Well-defined surgical incision under proper anesthesia,sufficient patient information and proficient anatomical skills of the physician are mandatory to prevent this rare adverse event.Careful and meticulous phacoemulsification of the cataract is suggested.
基金Supported by National Natural Science Foundation of China (No. 81070747)Research Award for New Century Excellent Talents in University (No. NCET08-0586)in ChinaScience and Technology Planning Project of Guangdong Province, China (No.2010B090400416)
文摘AIM: To quantify the changes in the lens profile with accommodation in different age groups. METHODS: The Pentacam HR system was used to obtain the images of the anterior eye segment from 23 young and 15 presbyopic emmetropic subjects in unaccommodated (with an accommodation stimulus of 0.0D) and accommodated (with an accommodation stimulus of 5.0D for the young group and 1.0D for the presbyopic group) states. The phakic crystalline lens shape, including curvature of crystalline lens and central lens thickness (CLT), and the measurements of anterior segment length (ASL), central anterior chamber depth (CACD) were investigated. The anterior chamber volume (ACV) was also measured. RESULTS: The reduction of CACD and ACV were significant in both groups after accommodation stimulus. From the profile of anterior eye segment, a significant decrease in anterior crystalline lens radii of curvature (-2.52mm) and a mean increase in CLT (0.222mm) and ASL (0.1138mm) were found in the. young group with an accommodation stimulus of 5.0D. However, no statistically significant changes of CLT, ASL, or crystalline lens radii of curvature were found in the presbyopic group. CONCLUSION: Our data showed that the shallowing of anterior chamber during accommodation was caused by the forward bulging of the anterior lens surface, rather than by anterior shifting of lens position in either young or presbyopic subjects.
文摘Dear Editor,I write to present the results of a study on the correlation between the ultrasound energy consumed during phacoemulsification with various preoperative parameters,including best corrected distance visual acuity(BCDVA),the signal to noise ratio(SNR)obtained by partial coherence laser interferometry and primarily,lens spikes measurements derived by A-scan ultrasound biometry.Quantification of crystalline lens hardness before cataract removal has been attempted by several researchers in the past.These have been in humans and in animals,in vivo and in vitro,and have used a variety of imaging modalities.
文摘Background: We sought to verify the efficacy and safety of transconjunctival 23-gauge pars plana vitrectomy (PPV) alone by our bimanual technique for the removal of dense posteriorly dislocated crystalline lens. Methods: A retrospective, noncomparative, interventional study of 31 consecutive cases of patients who underwent 23-gauge PPV alone for the removal of dense posteriorly dislocated crystalline lens following complicated cataract surgeries using our bimanual technique was conducted. The main outcomes measured included best-corrected visual acuity (BCVA), preoperative intraocular pressure (IOP), postoperative IOP and postoperative complications. Results: In all 31 cases included in this study, those dense posteriorly dislocated crystalline lenses were successfully removed. The enrolled patients consisted of 17 males and 14 females with a mean age of (75.84 ± 6.17) years (range 59 - 90). The mean follow-up length was (7.61 ± 1.87) months with a range of 6 months to 1 year. The mean preoperative BCVA was 0.22 ± 0.11 logMAR system, and the postoperative BCVA was 0.33 ± 0.07 logMAR system after 6 months of follow-up. The mean operative time was 46.32 ± 4.80 minutes with a range of 38.00 to 57.00 minutes. All of the conjunctival incisions self-closed within the first week with no wound leakage or hemorrhage. The postoperative complications were relatively rare. Conclusions: The removal of dense posteriorly dislocated crystalline lens might be a challenge for micro-incision vitrectomy. Our bimanual technique was proved to be an effective and safe method for those particular dense lenses using 23-gauge alone.
基金Supported by National Natural Science Foundation of China (No.39870801)Innovative Drug and Technological Development Program of Guangzhou Municipality, China (No.2006Z3-E4091)Guangdong Provincial Medical Science and Technology Research Foundation, China(No.B2006118)
文摘AIM:To investigate auto-cortex of crystalline lens induced iris neovascularization (INV). METHODS: Thirty-six eyes of 36 guinea-pigs were included and divided into three groups randomly in this cohort study. Group A: the right lens nucleus was extracted and the remaining cortical lens material was aspirated thoroughly.. Group B: the lens was removed and 30 mu L precipitated lens cortex was injected into the anterior chamber again. Group C: aspirated the lens cortex of the left eyes and inject them into the right anterior chambers about 10 mu L. Clinical changes were followed by slit-lamp examination and photograph. The eye balls were enucleated at the day of 2, 4, 7, 11, 13, 17 after operation. HE was used to detect the pathological changes. ' RESULTS:Group A:INV had not been observed until the end of empirical study. The stromal layer contained thick wall vessels, without expansion. Group B: All eyes developed INV. Postoperative (po) 7 days; the eyes developed intense and extensive INV. The vessels of iris expanded remarkably and neovascularization was observed erupting from it's lateral wall and stretching towards the anterior surface. Poll days, INV regressed gradually after lens cortex had been absorbed. Group C: Po four (4) days, new blood vessels liking red line were presented on the anterior surface of the iris and they were not obvious. CONCLUSION: Anterior chamber inside lens coriaceous can induce iris new blood vessels.
文摘AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications.
基金Supported by Tianjin Key Medical Discipline(Specialty)Construction Project(No.TJYXZDXK-037A).
文摘AIM:To observe early clinical outcome with lens position adjustment following the implantable collamer lens(ICL)surgery.METHODS:Sixty patients were selected for this retrospective study.One eye from each patient received Toric ICL for astigmatism correction,and the other received non-astigmatic ICL surgery using horizontal position.Patients with higher postoperative arch height were selected,and their non-astigmatic eye clinical outcome were observed after ICL surgery at 1wk,1,and 3mo.The clinical measurements included uncorrected visual acuity(UCVA),intraocular pressure(IOP),refractive state,corneal endothelium cell count,and arch height.Three months later,the ICL in each patient’s non-astigmatic eye was adjusted to the vertical from the horizontal position.The results were compared before and 1wk,1,and 3mo after adjustment.RESULTS:UCVA and IOP were significantly reduced 1wk after position adjustment compared to 1wk after ICL implantation(P<0.05).The patients demonstrated significantly reduced arch height and corneal endothelium cell count 1wk,1,and 3mo after adjusting position compared to 1wk,1,and 3mo after ICL implantation(P<0.05).However,there was no significant difference in refraction between 1wk,1,and 3mo after ICL implantation and position adjustment(P>0.05).CONCLUSION:Early positioning adjustment postphakic ICL implantation can benefit patients with adjusted arch height or higher IOP.Despite the good clinical effects,the doctors should pay attention to the potential for adverse effects on UCVA and corneal endothelium cells following early position adjustment after posterior chamber phakic ICL implantation.
文摘The effects of the gravitational redshift of gravitons upon spiral galaxy rotation energy are compared to the standard mass to light analyses in obtaining rotation curves. The derivation of the total baryonic matter compares well with the standard theory and the rotation velocity is matched to a high precision. The stellar mass distributions obtained from the fit with graviton energy loss are used to derive the surface brightness magnitudes for the galaxies, which agree well with the observed measurements. In a new field of investigation, the graviton theory is applied to the observations of gravitational lenses. The results of these applications of the theory suggest that it can augment the standard methods and may eliminate the need for dark matter.
基金supported by the National Natural Science Foundation of China(51904059)Applied Basic Research Program of Liaoning(2022JH2/101300200)+1 种基金Guangdong Basic and Applied Basic Research Foundation(2022A1515140188)Fundamental Research Funds for the Central Universities(N_(2)002005,N_(2)125004,N_(2)225044)。
文摘Carbon nitrides with two-dimensional layered structures and high theoretical capacities are attractive as anode materials for sodium-ion batteries while their low crystallinity and insufficient structural stability strongly restrict their practical applications.Coupling carbon nitrides with conductive carbon may relieve these issues.However,little is known about the influence of nitrogen(N)configurations on the interactions between carbon and C_(3)N_(4),which is fundamentally critical for guiding the precise design of advanced C_(3)N_(4)-related electrodes.Herein,highly crystalline C_(3)N_(4)(poly(triazine imide),PTI)based all-carbon composites were developed by molten salt strategy.More importantly,the vital role of pyrrolic-N for enhancing charge transfer and boosting Na+storage of C_(3)N_(4)-based composites,which was confirmed by both theoretical and experimental evidence,was spot-highlighted for the first time.By elaborately controlling the salt composition,the composite with high pyrrolic-N and minimized graphitic-N content was obtained.Profiting from the formation of highly crystalline PTI and electrochemically favorable pyrrolic-N configurations,the composite delivered an unusual reverse growth and record-level cycling stability even after 5000 cycles along with high reversible capacity and outstanding full-cell capacity retention.This work broadens the energy storage applications of C_(3)N_(4) and provides new prospects for the design of advanced all-carbon electrodes.
基金supported by the National Key Research and Development Program of China(No.2023YFD2401504)the National Natural Science Foundation of China(Nos.U21A20271,32225039)+2 种基金the Key R&D Program of Shandong Province(No.2022TZXD001)the Earmarked Fund for CARS(No.CARS-48)the Qingdao Shinan District Science and Technology Plan Project(No.2022-3-010-SW).
文摘Chitin is the second most abundant renewable polysaccharide on Earth.The degradation of chitin into soluble and bioactive N-acetyl chitooligosaccharides(NCOSs)and N-acetyl-D-glucosamine(GlcNAc)has emerged as a pivotal step in the efficient and sustainable utilization of chitin resources.However,because of its dense structure,high crystallinity,and poor solubility,chitin typically needs pretreatment via chemical,physical,and other methods before enzymatic conversion to enhance the accessibility between substrates and enzyme molecules.Consequently,there has been considerable interest in exploring the direct biological degradation of crystalline chitin as a cost-effective and environment-friendly technology.This review endeavors to present several biological methods for the direct degradation of chitin.We primarily focused on the importance of chitinase containing chitin-binding domain(CBD).Additionally,various modification strategies for increasing the degradation efficiency of crystalline chitin were introduced.Subsequently,the review systematically elucidated critical components of multi-enzyme catalytic systems,highlighting their potential for chitin degradation.Furthermore,the application of microorganisms in the degradation of crystalline chitin was also discussed.The insights in this review contribute to the explorations and investigations of enzymatic and microbial approaches for the direct degradation of crystalline chitin,thereby fostering advancements in biomass conversion.
基金Supported by the National Natural Science Foundation of China(No.52073181,No.52273134).
文摘AIM:To investigate the biocompatibility and bacterial adhesion properties of light responsive materials(LRM)and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular lenses(AIOLs).METHODS:Employing fundamental experimental research techniques,LRM with human lens epithelial cells(hLECs)and human retinal pigment epithelium cells(ARPE-19 cells)were co-cultured.Commercially available intraocular lenses(IOLs)were used as controls to perform cell counting kit-8(CCK-8),cell staining under varying light intensities,cell adhesion and bacterial adhesion experiments.RESULTS:LRM exhibited a stronger inhibitory effect on the proliferation of ARPE19 cells than commercially available IOLs when co-cultured with the undiluted extract for 96h(P<0.05).Under other culturing conditions,the effects on the proliferation of hLECs and ARPE-19 cells were not significantly different between the two materials.Under the influence of light irradiation at intensities of 200 and 300 mW/cm^(2),LRM demonstrated a markedly higher inhibitory effect on the survival of hLECs compared to commercially available IOLs(P<0.0001).They also showed a stronger suppressive effect on the survival rate of ARPE-19 cells,with significant differences observed at 200 mW/cm^(2)(P<0.001)and extremely significant differences at 300 mW/cm^(2)(P<0.0001).Additionally,compared to commercially available IOLs,LRM had a higher number of cells adhering to their surface(P<0.05),as well as a significantly greater number of adherent bacterium(P<0.0001).CONCLUSION:LRM,characterized by their excellent non-contact tunable deformability and low cytotoxicity to ocular tissues,show considerable potential for use in the fabrication of AIOLs.These materials demonstrate strong cell adhesion;however,during photothermal conversion processes involving shape deformation under various light intensities,the resultant temperature rise may harm surrounding cells.These factors suggest that while the material plays a positive role in reducing the incidence of posterior capsule opacification(PCO),it also poses potential risks for retinal damage.Additionally,the strong bacterial adhesion of these materials indicates an increased risk of endophthalmitis.
基金Supported by National Natural Science Foundation of China(No.81870680).
文摘AIM:To establish an animal model of form deprivation amblyopia based on a simulated cataract intraocular lens(IOLs).METHODS:Poly(dimethyl siloxane)-SiO_(2) thin films(PSF)with different degrees of opacity as IOL materials were prepared.The light transmission of the PSF-IOL was measured,and its in vitro biosafety was determined by cell counting kit(CCK)-8 assay using the HLEC-B3 cell line and ARPE-19 cell line.Subsequently,the in vivo safety was determined by implanting the PSF-IOL with 10%wt SiO_(2) into the right eyes of New Zealand white rabbits(PSF-IOL group),and compared with two control groups:contralateral comparison group and normal control(NC)group(Contralateral comparison group:the fellow eye;NC group:a group of binocular normal rabbits without intervention).The flash visual-evoked potentials(F-VEPs)were measured to verify amblyopia.RESULTS:PSFs containing 0,2%,and 10%wt SiO_(2) were successfully constructed.The 0 SiO_(2) PSF was transparent,while the 10%wt SiO_(2) PSF was completely opaque.It was found that PSF did not induce unwanted cytotoxicity in HLECs and ARPE19 cells in vitro.In vitro,PSF-IOL with 10%wt SiO_(2) was also non-toxic,and no significant inflammation or structural changes occurred after four weeks of PSF-IOL implantation.Finally,our IOL-simulated congenital cataract rabbit detected by F-VEPs suggested tentative amblyopia.CONCLUSION:A PSF-IOL that mimics cataracts is created.A novel form deprivation model is created by the IOL-simulated congenital cataract rabbit.It can be developed fast and stable and holds great potential for future study.
基金Supported by National Natural Science Foundation of China(No.81900910)Natural Science Foundation of Zhejiang Province(No.LQ19H120003)Basic Scientific Research Project of Wenzhou(No.Y2023809).
文摘AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants underwent ICL surgery and were divided into the low(<250μm)and normal(250-1000μm)vault groups based on the postoperative vault at 3mo.The preoperative biometric parameters and clinical outcomes were compared between the two groups.The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations.RESULTS:Sixteen(23 eyes)and 36 patients(63 eyes)were in the low and normal vault groups,respectively.All implantation procedures were uneventful with no cataract formation in the early postoperative period.The sulcusto-sulcus lens rise(STSL)and iris ciliary angle(ICA)were correlated with vault at 3mo after surgery.Every 0.1 mm increase in STSL was associated with 38.9μm decrease in the postoperative 3-month vault.A rise of 1 degree in ICA is associated with a reduction of 4μm in vault.CONCLUSION:Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation,suggesting a need for adjustments to the ICL size in these patients.Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery.
基金supported by the Young Scientists Fund of the National Natural Science Foundation of China(Grant No.12104148)the Fundamental Research Funds for the Central Universities(Grant No.531118010565).
文摘By including certain point group symmetry in the classification of band topology,Fu proposed a class of threedimensionaltopological crystalline insulators(TCIs)without spin-orbit coupling in 2011.In Fu’s model,surface states(ifpresent)doubly degenerate atГandM when time-reversal and C_(4) symmetries are preserved.The analogs of Fu’s modelwith surface states quadratically degenerate atM are widely studied,while surface states with quadratic degeneracy atГare rarely reported.In this study,we propose a three-dimensional TCI without spin-orbit coupling in a judiciously designednonsymmorphic photonic metacrystal.The surface states of photonic TCIs exhibit quadratic band degeneracy in the(001)surface Brillouin zone(BZ)center(Гpoint).The gapless surface states and their quadratic dispersion are protected by C4and time-reversal symmetries,which correspond to the nontrivial band topology characterized by Z_(2)topological invariant.Moreover,the surface states along lines fromГto the(001)surface BZ boundary exhibit zigzag feature,which is interpretedfrom symmetry perspective by building composite operators constructed by the product of glide symmetries with timereversalsymmetry.The metacrystal array surrounded with air possesses high order hinge states with electric fields highlylocalized at the hinge that may apply to optical sensors.The gapless surface states and hinge states reside in a cleanfrequency bandgap.The topological surface states emerge at the boundary of the metacrystal and perfect electric conductor(PEC),which provide a pathway for topologically manipulating light propagation in photonic devices.
文摘The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract surgery in diabetic patients poses many challenges:Poor epithelial healing,decreased corneal sensitivity,increased central corneal thickness,decreased endothelial cell count,variable topography,poor pupillary dilatation,anterior capsular phimosis,posterior capsular opacification(PCO),chances of progression of diabetic retinopathy(DR),zonular weakness,and vitreous prolapse and diabetic macular edema.Selection of an appropriate intraocular lens(IOL)is crucial for visual rehabilitation and monitoring DR.The choice of IOL in diabetic cataract patients is a challenging scenario.Square-edge IOLs are favored for their capacity to mitigate PCO,whereas hydrophilic counterparts may incur calcification in the setting of proliferative DR.The advisability of premium IOLs for achieving spectacle independence warrants judicious evaluation,particularly in the presence of advanced retinopathy.Optimal IOL placement within the capsular bag is advocated to minimize postoperative complications.Rigorous preoperative assessment and informed patient counseling regarding IOL options are indispensable for optimizing surgical outcomes.This review article covers various aspects regarding the choice of IOLs in different case scenarios and complications in the diabetic population.
基金supported by National Natural Science Foundation of China(Nos.12305224,U23B2099 and 11975065)the Natural Science Foundation of Liaoning Province(No.2021-BS-223)+1 种基金the Liaoning Provincial Department of Education Youth Fund Project(No.LJKQZ20222309)supports from the National Laboratory of Heavy-ion Research Facility(HIRFL)in the Institute of Modern Physics in Lanzhou,China.
文摘In this paper,high-energy Ne ions were used to irradiate Zr_(63.5)Cu_(23)Al_(9)Fe_(4.5) metallic glass(MG)and crystalline W to investigate their difference in mechanical response after irradiation.The results showed that with the irradiation dose increased,the tensile micro-strain increased,nano-hardness increased from 7.11 GPa to 7.90 GPa and 8.62 GPa,Young’s modulus increased,and H3/E2 increased which indicating that the plastic deformability decreased in crystalline W.Under the same irradiation conditions,the Zr_(63.5)Cu_(23)Al_(9)Fe_(4.5) MG still maintained the amorphous structure and became more disordered despite the longer range and stronger displacement damage of Ne ions in Zr_(63.5)Cu_(23)Al_(9)Fe_(4.5) MG than in crystalline W.Unlike the irradiation hardening and embrittlement behavior of crystalline W,Zr_(63.5)Cu_(23)Al_(9)Fe_(4.5) MG showed the gradual decrease in hardness from 6.02 GPa to 5.89 GPa and 5.50 GPa,the decrease in modulus and the increase in plastic deformability with the increasing dose.Possibly,the irradiation softening and toughening phenomenon of Zr_(63.5)Cu_(23)Al_(9)Fe_(4.5) MG could provide new ideas for the design of nuclear materials.
基金the Deputyship for Research and Innovation,Ministry of Education in Saudi Arabia for funding this research work through the project(No.IFKSUOR3-433-1)。
文摘AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defocus profile in young adults.METHODS:Seventeen young adults(2 males and 15 females;age 23.17±4.48y)were randomly assigned to wear two designs binocularly with a one-week washout period in between.Total of four MFGPCL designs were assessed.All designs were distance-center that varied in two add power(+1.50 and 3.00 D)and/or two distance zone(DZ)diameters(1.50 and 3.00 mm;design A:DZ 1.5/add 3.0,B:DZ 1.5/add 1.5,C:DZ 3.0/add 3.0,D:DZ 3.0/add 1.5).ChT,AL,and peripheral refraction data were collected on each subject at baseline,on days 1 and 7 of MFGPCL daily wear.ChT was assessed in four quadrants using a spectraldomain optical coherence tomography.RESULTS:AL was shortened by-26±44μm with lens C,-18±27μm with lens D,-13±29μm with lens A,and-8±30μm with lens B(all P<0.05).A significant overall increase in ChT was observed with all 4 designs(lens A:+6±6μm,B:+3±7μm,C:+8±7μm,and D:+8±7μm).Temporal and superior choroid exhibited more choroidal thickening associated with MFGPCL.All designs induced significant relative peripheral myopia(RPM)beyond the central 20o across the horizontal meridian in both nasal and temporal fields(P<0.05).CONCLUSION:MFGPCLs show a significant influence on ChT and AL,which are associated with significant increase in RPM after short-term wear.The reliability and feasibility of quantifying short-term changes in ChT support its use as a promising marker for the long-term efficacy of myopia-controlling treatments.