The spherical model of time and location calculation of the lightning discharge is given. The calculations are made by means of radio signals detection by sensors of the distributed network. The full solution of a pro...The spherical model of time and location calculation of the lightning discharge is given. The calculations are made by means of radio signals detection by sensors of the distributed network. The full solution of a problem of lightning discharge cloud-ground type location for three sensors is given. Based on this task the lightning location method for a network of sensors was developed. By means of computational experiments, the analysis of accuracy of the model depending on radio signals detection accuracy at observing stations was done.展开更多
In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave th...In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower.展开更多
Based on data of cloud-to-ground lightning detected by a lightning location system in Jiangsu Province from 2007 to 2012and data of thunderstorm days from seven meteorological observation stations in Huai'an durin...Based on data of cloud-to-ground lightning detected by a lightning location system in Jiangsu Province from 2007 to 2012and data of thunderstorm days from seven meteorological observation stations in Huai'an during 1961-2012,the spatial and temporal distribution characteristics of cloud-to-ground lightning in Huai'an were analyzed.The results show that the total frequency of cloud-to-ground lightning in one day was closely related to the intensity and frequency of thunder and lightning.The seasonal variations in the total frequency of cloud-to-ground lightning in Huai'an.The total frequency was shown in unimodal distribution,and the extreme values always appeared in July or August.Most cloud-to-ground lightning was negative,and its frequency accounted for about95.3% of the total frequency.Cloud-to-ground lightning density was high in the south of Huai'an and low in the north,and the serious and very serious ground flash zones concentrated in the south of Hongze County,and most parts of Xuyi and Jinhu County,so lightning protection should be an important task particularly in these regions.展开更多
雷电作为自然界一种极端天气的表现形式,常给地基、地面、高耸建筑等造成严重破坏。工程防雷措施依赖于土体雷电冲击特性。现阶段,研究人员大多从电气工程角度探究雷电冲击土体造成的危害,但因学科间的差异与局限,雷电作用下岩土工程与...雷电作为自然界一种极端天气的表现形式,常给地基、地面、高耸建筑等造成严重破坏。工程防雷措施依赖于土体雷电冲击特性。现阶段,研究人员大多从电气工程角度探究雷电冲击土体造成的危害,但因学科间的差异与局限,雷电作用下岩土工程与电气工程的交叉融合方面的研究十分欠缺。本文构建土体雷电冲击模型,基于电弧通道能量平衡方程计算雷电放电产生的冲击波压力,将冲击波压力作为外加荷载作用在土体中,并通过修正Mohr-Coulomb屈服准则考虑动荷载下土体应变硬化,利用土体的理想锁定状态方程(Idealized Locked Equation of State)和动态扩孔方法考虑冲击波非稳态加载,探究雷电冲击下土体的弹塑性界面及应力时程变化规律。研究表明:在雷电冲击下,土体应力随时间变化呈现先陡增后迅速衰减的趋势,应力突变点表明土体此时正处于弹塑性交界面;在应力突变点之前,土体附加应力趋于0,处于弹性状态。任一时刻下,随着逐渐远离雷电冲击点,土体应力呈现迅速衰减的趋势,应力发生突变骤降表明此处土体正处于弹塑性交界面;在突变点之后土体附加应力趋于0,处于弹性状态。土体压缩系数对土体的弹塑性界面变化具有显著影响,随着压缩指标增大,土体塑性区半径逐渐减小;随着土体黏聚力逐渐增大,土体塑性区半径逐渐减小;增大土体弹性模量可以增大土体塑性区半径,但变化幅度相对较小;电流波形对土体塑性区中的应力会产生较大影响,而对土体弹性区影响较小。展开更多
A time-of-arrival(TOA) system based on GPS technology for locating VHF radiation sources from lightning has been developed and used in observation sites in the northern Shandong Province,China.The 3D images of the lig...A time-of-arrival(TOA) system based on GPS technology for locating VHF radiation sources from lightning has been developed and used in observation sites in the northern Shandong Province,China.The 3D images of the lightning progression have been obtained successfully for the first time in China.The 3D-channel evolutions of typical negative CG,positive CG and IC lightning flashes have been discussed together with the data of fast electric field change.It was found that significant differences existed between the negative and positive CG lightning flashes in terms of the initiation and propagation of the radiation sources.The preliminary breakdown of a negative CG lightning flash propagated at a speed about 5.2×104 m/s.The stepped leader of negative CG lightning flashes was trigged by negative initial breakdown.Thereafter,it propagated downward at a speed of 1.3×105 m/s.The initial process of the positive CG lightning flashes was also a propagation process of negative streamer.These streamers propagated dominantly horizontally in the positive charge region and accumulated positive charges at the origin of the lightning,and as a consequence,initiated downward positive streamers.A new type of lightning discharge that was triggered by a narrow bipolar pulse(NBP) is discussed in this study.The NBP was originated at altitude of about 10.5 km in the upper positive charge region.As a distinct difference from normal IC flash,its channels extended horizontally all around and produced a lot of radiation sources.The source power of the NBP could approach 16.7 kW,which is much greater than that of normal lightning discharge ranging between 100 mW and 500 W.The 3D propagation of this new type of lightning discharge was observed and obtained for the first time in China.The possible initiation mechanism of this new type of light-ning is discussed here.展开更多
为了探讨闪电探测站布局对闪电定位精度的影响,基于福建省九仙山自然闪电观测试验基地的磁场波形观测资料,选取探测站网内外不同方位和不同距离的10次地闪回击,以10站(或9站)同步的定位结果为基准,利用到达时间差法(Time of Arrival,TO...为了探讨闪电探测站布局对闪电定位精度的影响,基于福建省九仙山自然闪电观测试验基地的磁场波形观测资料,选取探测站网内外不同方位和不同距离的10次地闪回击,以10站(或9站)同步的定位结果为基准,利用到达时间差法(Time of Arrival,TOA),对比分析了任意5—8站不同测站组合情况下的定位结果差异性,并探讨定位差异性的可能原因。结果表明:闪电定位与测站数量和测站布局密切相关,同样的测站数量,不同测站布局的定位结果存在较大差异,而随着测站数量的增加,由测站布局不同所带来的差异性逐渐减小。相同的测站数量和布局,对不同方位距离闪电的定位偏差也存在明显不同。在测站网外围区域的闪电定位偏差明显大于网内,网外闪电定位结果往往呈现“带状分布”,距离测站网越远,这种“带状分布”的偏差分布越明显,这是由于双曲线交汇形成的狭长空间区域所致。展开更多
文摘The spherical model of time and location calculation of the lightning discharge is given. The calculations are made by means of radio signals detection by sensors of the distributed network. The full solution of a problem of lightning discharge cloud-ground type location for three sensors is given. Based on this task the lightning location method for a network of sensors was developed. By means of computational experiments, the analysis of accuracy of the model depending on radio signals detection accuracy at observing stations was done.
文摘In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower.
文摘Based on data of cloud-to-ground lightning detected by a lightning location system in Jiangsu Province from 2007 to 2012and data of thunderstorm days from seven meteorological observation stations in Huai'an during 1961-2012,the spatial and temporal distribution characteristics of cloud-to-ground lightning in Huai'an were analyzed.The results show that the total frequency of cloud-to-ground lightning in one day was closely related to the intensity and frequency of thunder and lightning.The seasonal variations in the total frequency of cloud-to-ground lightning in Huai'an.The total frequency was shown in unimodal distribution,and the extreme values always appeared in July or August.Most cloud-to-ground lightning was negative,and its frequency accounted for about95.3% of the total frequency.Cloud-to-ground lightning density was high in the south of Huai'an and low in the north,and the serious and very serious ground flash zones concentrated in the south of Hongze County,and most parts of Xuyi and Jinhu County,so lightning protection should be an important task particularly in these regions.
文摘雷电作为自然界一种极端天气的表现形式,常给地基、地面、高耸建筑等造成严重破坏。工程防雷措施依赖于土体雷电冲击特性。现阶段,研究人员大多从电气工程角度探究雷电冲击土体造成的危害,但因学科间的差异与局限,雷电作用下岩土工程与电气工程的交叉融合方面的研究十分欠缺。本文构建土体雷电冲击模型,基于电弧通道能量平衡方程计算雷电放电产生的冲击波压力,将冲击波压力作为外加荷载作用在土体中,并通过修正Mohr-Coulomb屈服准则考虑动荷载下土体应变硬化,利用土体的理想锁定状态方程(Idealized Locked Equation of State)和动态扩孔方法考虑冲击波非稳态加载,探究雷电冲击下土体的弹塑性界面及应力时程变化规律。研究表明:在雷电冲击下,土体应力随时间变化呈现先陡增后迅速衰减的趋势,应力突变点表明土体此时正处于弹塑性交界面;在应力突变点之前,土体附加应力趋于0,处于弹性状态。任一时刻下,随着逐渐远离雷电冲击点,土体应力呈现迅速衰减的趋势,应力发生突变骤降表明此处土体正处于弹塑性交界面;在突变点之后土体附加应力趋于0,处于弹性状态。土体压缩系数对土体的弹塑性界面变化具有显著影响,随着压缩指标增大,土体塑性区半径逐渐减小;随着土体黏聚力逐渐增大,土体塑性区半径逐渐减小;增大土体弹性模量可以增大土体塑性区半径,但变化幅度相对较小;电流波形对土体塑性区中的应力会产生较大影响,而对土体弹性区影响较小。
基金supported by National Natural Science Foundation of China (Grant No.40775004)Knowledge Innovation Program of the Chinese Academy of Sciences (Grant No.KZCX2-YW-206-2)the R & D Special Fund for Public Welfare Industry (meteorology) (Grant No.GYHY2007622)
文摘A time-of-arrival(TOA) system based on GPS technology for locating VHF radiation sources from lightning has been developed and used in observation sites in the northern Shandong Province,China.The 3D images of the lightning progression have been obtained successfully for the first time in China.The 3D-channel evolutions of typical negative CG,positive CG and IC lightning flashes have been discussed together with the data of fast electric field change.It was found that significant differences existed between the negative and positive CG lightning flashes in terms of the initiation and propagation of the radiation sources.The preliminary breakdown of a negative CG lightning flash propagated at a speed about 5.2×104 m/s.The stepped leader of negative CG lightning flashes was trigged by negative initial breakdown.Thereafter,it propagated downward at a speed of 1.3×105 m/s.The initial process of the positive CG lightning flashes was also a propagation process of negative streamer.These streamers propagated dominantly horizontally in the positive charge region and accumulated positive charges at the origin of the lightning,and as a consequence,initiated downward positive streamers.A new type of lightning discharge that was triggered by a narrow bipolar pulse(NBP) is discussed in this study.The NBP was originated at altitude of about 10.5 km in the upper positive charge region.As a distinct difference from normal IC flash,its channels extended horizontally all around and produced a lot of radiation sources.The source power of the NBP could approach 16.7 kW,which is much greater than that of normal lightning discharge ranging between 100 mW and 500 W.The 3D propagation of this new type of lightning discharge was observed and obtained for the first time in China.The possible initiation mechanism of this new type of light-ning is discussed here.
文摘为了探讨闪电探测站布局对闪电定位精度的影响,基于福建省九仙山自然闪电观测试验基地的磁场波形观测资料,选取探测站网内外不同方位和不同距离的10次地闪回击,以10站(或9站)同步的定位结果为基准,利用到达时间差法(Time of Arrival,TOA),对比分析了任意5—8站不同测站组合情况下的定位结果差异性,并探讨定位差异性的可能原因。结果表明:闪电定位与测站数量和测站布局密切相关,同样的测站数量,不同测站布局的定位结果存在较大差异,而随着测站数量的增加,由测站布局不同所带来的差异性逐渐减小。相同的测站数量和布局,对不同方位距离闪电的定位偏差也存在明显不同。在测站网外围区域的闪电定位偏差明显大于网内,网外闪电定位结果往往呈现“带状分布”,距离测站网越远,这种“带状分布”的偏差分布越明显,这是由于双曲线交汇形成的狭长空间区域所致。