Objective:To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.Methods:Seventy-six patients respectively with early transected and avulsed types of...Objective:To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.Methods:Seventy-six patients respectively with early transected and avulsed types of Achilles tendon rupture were selected and treated with internal fixation of steel-wire limited loop.The patients began to take exercise for their lower limbs through continous passive motion as early as possible after surgical repair,and the loops were removed after 3-5 months.Six months later,the condition of complications including Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis,cutaneous sensation in sural nerve dominance region,time back to preinjury work or learning as well as time to physical activities were observed.One year later,the therapeutic effect was evaluated,and the maximum circumferences of bilateral legs and raptured plane circumferences of Achilles tendon were measured.Results:The wound of all patients healed well,no complications like Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis occured,and the cutaneous sensation in sural nerve dominance region was normal.The mean time back to preinjury work or learning as well as to pysical activities of all patients were respectively 10 and 22 weeks.Seventy out of 76 patients(92.1%) achieved an excellent effect,and 6(7.9%) good effect.The excellent and good rate came up to 100%.The maximum circumference in the affected leg decreased to 2 mm averagely compared with the offside,while the ruptured plane circumferences of Achilles tendon in the affected side increased to 2.2 mm compared with the offside.Conclusions:Kor early Achilles tendon rupture,internal fixation of steel-wire limited loop can recover the ankle function better,return to the preinjury state in the shortest lime,and has few complications.展开更多
To solve the flight safety problem caused by nonlinear instabilities(category II pilot induced oscillations, PIOs) of the closed-loop pilot-vehicle system with rate-limiting actuator, the antiwindup(AW) compensati...To solve the flight safety problem caused by nonlinear instabilities(category II pilot induced oscillations, PIOs) of the closed-loop pilot-vehicle system with rate-limiting actuator, the antiwindup(AW) compensation method to avoid category II PIOs is investigated. Firstly, the AW compensation method originally used for controlling input magnitude limited system is introduced, then this method is extended for controlling input rate-limiting system through a circle criterion theorem. Secondly, the establishment of the AW compensator is transformed into the solving of linear matrix inequalities. Finally, an AW compensator establishment algorithm for the closed-loop pilot-vehicle system with the rate-limiting actuator is obtained. The effectiveness of the AW compensation method to avoid category II PIOs is validated by time-domain simulations,and compared with rate-limited feedback(RLF) command rate compensation method. The results show that the AW compensation method can effectively suppress category II PIOs and maintain the nominal performance when the closed-loop pilot-vehicle system is normal. Unlike the command rate compensator which works upon system uninterruptedly, the AW compensation method affects the closed-loop pilot-vehicle system only when the rate-limiting of actuator is activated, so it is a novel PIO avoidance method.展开更多
针对逆变侧交流故障下高压直流(line commutated converter-high voltage direct current,LCC-HVDC)输电系统易引发连续换相失败问题,该文分阶段分析了连续换相失败的产生机理。明确了当产生触发角偏差后,直流电流调节效果与实际触发角...针对逆变侧交流故障下高压直流(line commutated converter-high voltage direct current,LCC-HVDC)输电系统易引发连续换相失败问题,该文分阶段分析了连续换相失败的产生机理。明确了当产生触发角偏差后,直流电流调节效果与实际触发角不匹配是连续换相失败的重要诱因。同时不对称故障后,负序分量通过极控、阀控两级控制系统对实际触发角造成的影响,增加连续换相失败的风险。因此提出了一种基于实际触发角响应的连续换相失败抑制方法,通过实际触发角修正整流侧电流指令值。与此同时,该方法通过陷波器降低负序电流对极控层触发角指令值的影响,通过相序解耦控制器和换相电压相位补偿降低负序电压对阀控层触发角实际值的影响。该方法能实现动态、自适应的电流指令值调整,提升恢复过程中直流电流与实际触发角的匹配度,提升直流系统抵御连续换相失败能力。在CIGRE标准测试模型和实际工程模型中,验证了理论分析的正确性和优化方法的有效性。展开更多
基金It is supported by Scientific Research Planned Project of Taizhou Science and Technology Bureau in Zhejiang:No.031212
文摘Objective:To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.Methods:Seventy-six patients respectively with early transected and avulsed types of Achilles tendon rupture were selected and treated with internal fixation of steel-wire limited loop.The patients began to take exercise for their lower limbs through continous passive motion as early as possible after surgical repair,and the loops were removed after 3-5 months.Six months later,the condition of complications including Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis,cutaneous sensation in sural nerve dominance region,time back to preinjury work or learning as well as time to physical activities were observed.One year later,the therapeutic effect was evaluated,and the maximum circumferences of bilateral legs and raptured plane circumferences of Achilles tendon were measured.Results:The wound of all patients healed well,no complications like Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis occured,and the cutaneous sensation in sural nerve dominance region was normal.The mean time back to preinjury work or learning as well as to pysical activities of all patients were respectively 10 and 22 weeks.Seventy out of 76 patients(92.1%) achieved an excellent effect,and 6(7.9%) good effect.The excellent and good rate came up to 100%.The maximum circumference in the affected leg decreased to 2 mm averagely compared with the offside,while the ruptured plane circumferences of Achilles tendon in the affected side increased to 2.2 mm compared with the offside.Conclusions:Kor early Achilles tendon rupture,internal fixation of steel-wire limited loop can recover the ankle function better,return to the preinjury state in the shortest lime,and has few complications.
基金supported by the National Basic Research Program(973Program)(2015CB755805)the National Natural Science Foundation of China(61374145)
文摘To solve the flight safety problem caused by nonlinear instabilities(category II pilot induced oscillations, PIOs) of the closed-loop pilot-vehicle system with rate-limiting actuator, the antiwindup(AW) compensation method to avoid category II PIOs is investigated. Firstly, the AW compensation method originally used for controlling input magnitude limited system is introduced, then this method is extended for controlling input rate-limiting system through a circle criterion theorem. Secondly, the establishment of the AW compensator is transformed into the solving of linear matrix inequalities. Finally, an AW compensator establishment algorithm for the closed-loop pilot-vehicle system with the rate-limiting actuator is obtained. The effectiveness of the AW compensation method to avoid category II PIOs is validated by time-domain simulations,and compared with rate-limited feedback(RLF) command rate compensation method. The results show that the AW compensation method can effectively suppress category II PIOs and maintain the nominal performance when the closed-loop pilot-vehicle system is normal. Unlike the command rate compensator which works upon system uninterruptedly, the AW compensation method affects the closed-loop pilot-vehicle system only when the rate-limiting of actuator is activated, so it is a novel PIO avoidance method.
文摘针对逆变侧交流故障下高压直流(line commutated converter-high voltage direct current,LCC-HVDC)输电系统易引发连续换相失败问题,该文分阶段分析了连续换相失败的产生机理。明确了当产生触发角偏差后,直流电流调节效果与实际触发角不匹配是连续换相失败的重要诱因。同时不对称故障后,负序分量通过极控、阀控两级控制系统对实际触发角造成的影响,增加连续换相失败的风险。因此提出了一种基于实际触发角响应的连续换相失败抑制方法,通过实际触发角修正整流侧电流指令值。与此同时,该方法通过陷波器降低负序电流对极控层触发角指令值的影响,通过相序解耦控制器和换相电压相位补偿降低负序电压对阀控层触发角实际值的影响。该方法能实现动态、自适应的电流指令值调整,提升恢复过程中直流电流与实际触发角的匹配度,提升直流系统抵御连续换相失败能力。在CIGRE标准测试模型和实际工程模型中,验证了理论分析的正确性和优化方法的有效性。