Road traffic congestion has become an everyday phenomenon in today's cities all around the world.The reason is clear:at peak hours,the road network operates at full capacity.In this way,growing traffic demand cann...Road traffic congestion has become an everyday phenomenon in today's cities all around the world.The reason is clear:at peak hours,the road network operates at full capacity.In this way,growing traffic demand cannot be satisfied,not even with traffic-responsive signal plans.The external impacts of traffic congestion come with a serious socio-economic cost:air pollution,increased travel times and fuel consumption,stress,as well as higher risk of accidents.To tackle these problems,a number of European cities have implemented reduced speed limit measures.Similarly,a general urban speed limit measure is in preparatory phase in Budapest,Hungary.In this context,a complex preliminary impact assessment is needed using a simulated environment.Two typical network parts of Budapest were analyzed with microscopic traffic simulations.The results revealed that speed limits can affect traffic differently in diverse network types indicating that thorough examination and preparation works are needed prior to the introduction of speed limit reduction.展开更多
BACKGROUND In most elderly patients with intertrochanteric fractures,satisfactory fracture reduction can be achieved by closed reduction using a traction table.However,intertrochanteric fractures cannot achieve satisf...BACKGROUND In most elderly patients with intertrochanteric fractures,satisfactory fracture reduction can be achieved by closed reduction using a traction table.However,intertrochanteric fractures cannot achieve satisfactory reduction in a few patients,which is called irreducible intertrochanteric fractures.Especially for type 31A3 irreducible intertrochanteric fractures,limited open reduction of the broken end with different intraoperative reduction methods is required to achieve satisfactory reduction and fixation.AIM To discuss clinical efficacy of intracortical screw insertion plus limited open reduction in type 31A3 irreducible intertrochanteric fractures in the elderly.METHODS A retrospective analysis was performed on 23 elderly patients with type 31A3 irreducible intertrochanteric fractures(12 males and 11 females,aged 65-89-yearsold)who received treatment at the orthopedics department.After type 31A3 irreducible intertrochanteric fractures were confirmed by intraoperative C-arm,all of these cases received intracortical screw insertion plus limited open reduction in the broken end with intramedullary screw internal fixation.The basic information of surgery,reduction effects,and functional recovery scores of the hip joint were assessed.RESULTS All patients were followed up for 13.8 mo on average.The operation time was 53.8±13.6 min(40-95 min).The intraoperative blood loss was 218.5±28.6 mL(170-320 mL).The average number of intraoperative X-rays was 22.8±4.6(18-33).The average time to fracture union was 4.8±0.7 mo.The reduction effect was assessed using Kim’s fracture reduction evaluation.Twenty cases achieved grade I fracture reduction and three cases grade II fracture reduction.All of them achieved excellent or good fracture reduction.Upon the last follow-up,the functional recovery scores score was 83.6±9.8,which was not significantly different from the functional recovery scores score(84.8±10.7)before the fracture(t=0.397,P=0.694).CONCLUSION With careful preoperative preparation,intracortical screw insertion plus limited open reduction contributed to high-quality fracture reduction and fixation.Good clinical outcomes were achieved without increasing operation time and intraoperative blood loss.展开更多
While manganese-based cathodes have been intensively studied for zinc-ion batteries(ZIBs),the limited rate capability and cycle life have always been a difficult problem to be solved.Here,we report a mixed valent mang...While manganese-based cathodes have been intensively studied for zinc-ion batteries(ZIBs),the limited rate capability and cycle life have always been a difficult problem to be solved.Here,we report a mixed valent manganese oxide(MnOx)cathode with superior electrochemical performance,which exhibits a high specific capacity of 450 mA h/g at 0.2 C and a satisfactory specific capacity of 158.3 mA h/g at a high rate of 5 C.The mixed cathode system reduces the charge transfer resistance,and show good surface stability and adsorption properties,so it is beneficial for the storage of Zn^(2+).Meanwhile,coaxial fiber ZIBs(CFZIBs)with splendid flexibility are assembled utilizing the elaborately prepared cathode material.The CFZIBs achieve a reversible capacity of 255.8 m A h/g and the capacity retention rate is as high as 80%after 1000 bending deformations.This study provides new opportunities for designing ZIBs with high performance and high flexibility.展开更多
基金supported by the National Laboratory for Autonomous Systems fund of the Hungarian Ministry for Innovation and Technology(2019-2.1.7-ERA-NET-2021-00019).
文摘Road traffic congestion has become an everyday phenomenon in today's cities all around the world.The reason is clear:at peak hours,the road network operates at full capacity.In this way,growing traffic demand cannot be satisfied,not even with traffic-responsive signal plans.The external impacts of traffic congestion come with a serious socio-economic cost:air pollution,increased travel times and fuel consumption,stress,as well as higher risk of accidents.To tackle these problems,a number of European cities have implemented reduced speed limit measures.Similarly,a general urban speed limit measure is in preparatory phase in Budapest,Hungary.In this context,a complex preliminary impact assessment is needed using a simulated environment.Two typical network parts of Budapest were analyzed with microscopic traffic simulations.The results revealed that speed limits can affect traffic differently in diverse network types indicating that thorough examination and preparation works are needed prior to the introduction of speed limit reduction.
基金by the National Natural Science Foundation of China,No.81902206.
文摘BACKGROUND In most elderly patients with intertrochanteric fractures,satisfactory fracture reduction can be achieved by closed reduction using a traction table.However,intertrochanteric fractures cannot achieve satisfactory reduction in a few patients,which is called irreducible intertrochanteric fractures.Especially for type 31A3 irreducible intertrochanteric fractures,limited open reduction of the broken end with different intraoperative reduction methods is required to achieve satisfactory reduction and fixation.AIM To discuss clinical efficacy of intracortical screw insertion plus limited open reduction in type 31A3 irreducible intertrochanteric fractures in the elderly.METHODS A retrospective analysis was performed on 23 elderly patients with type 31A3 irreducible intertrochanteric fractures(12 males and 11 females,aged 65-89-yearsold)who received treatment at the orthopedics department.After type 31A3 irreducible intertrochanteric fractures were confirmed by intraoperative C-arm,all of these cases received intracortical screw insertion plus limited open reduction in the broken end with intramedullary screw internal fixation.The basic information of surgery,reduction effects,and functional recovery scores of the hip joint were assessed.RESULTS All patients were followed up for 13.8 mo on average.The operation time was 53.8±13.6 min(40-95 min).The intraoperative blood loss was 218.5±28.6 mL(170-320 mL).The average number of intraoperative X-rays was 22.8±4.6(18-33).The average time to fracture union was 4.8±0.7 mo.The reduction effect was assessed using Kim’s fracture reduction evaluation.Twenty cases achieved grade I fracture reduction and three cases grade II fracture reduction.All of them achieved excellent or good fracture reduction.Upon the last follow-up,the functional recovery scores score was 83.6±9.8,which was not significantly different from the functional recovery scores score(84.8±10.7)before the fracture(t=0.397,P=0.694).CONCLUSION With careful preoperative preparation,intracortical screw insertion plus limited open reduction contributed to high-quality fracture reduction and fixation.Good clinical outcomes were achieved without increasing operation time and intraoperative blood loss.
基金National Natural Science Foundation of China with Grant No.21905304Natural Science Foundation of Shandong Province(No.ZR2019BEM031)+1 种基金the Fundamental Research Funds for the Central Universities(Nos.18CX02158A,05Y18030020 and 19CX05001A)the support from the Western University-Soochow University Center for Synchrotron Radiation Research。
文摘While manganese-based cathodes have been intensively studied for zinc-ion batteries(ZIBs),the limited rate capability and cycle life have always been a difficult problem to be solved.Here,we report a mixed valent manganese oxide(MnOx)cathode with superior electrochemical performance,which exhibits a high specific capacity of 450 mA h/g at 0.2 C and a satisfactory specific capacity of 158.3 mA h/g at a high rate of 5 C.The mixed cathode system reduces the charge transfer resistance,and show good surface stability and adsorption properties,so it is beneficial for the storage of Zn^(2+).Meanwhile,coaxial fiber ZIBs(CFZIBs)with splendid flexibility are assembled utilizing the elaborately prepared cathode material.The CFZIBs achieve a reversible capacity of 255.8 m A h/g and the capacity retention rate is as high as 80%after 1000 bending deformations.This study provides new opportunities for designing ZIBs with high performance and high flexibility.