Close-range photogrammetry is to determine the shape and size of the object, instead of it's absolute position. Therefore, at first, any translation and rotation of the photogrammetric model of the object caused b...Close-range photogrammetry is to determine the shape and size of the object, instead of it's absolute position. Therefore, at first, any translation and rotation of the photogrammetric model of the object caused by whole geodesic, photographic and photogrammetric procedures in close-range photogrammetry could not be considered. However, it is necessary to analyze all the reasons which cause the deformations of the shape and size and to present their corresponding theories and equations. This situation, of course, is very different from the conventional topophotogrammetry. In this paper some specific characters of limit errors in close-range photogrammetry are presented in detail, including limit errors for calibration of interior elements for close-range cameras, the limit errors of relative and absolute orientations in close-range cameras, the limit errors of relative and absolute orientations in close-range photogrammetric procedures, and the limit errors of control works in close-range photogrammetry. A theoretical equation of calibration accuracy for close-range camerais given. Relating to the three examples in this paper, their theoretical accuracy requirement of interior elements of camera change in the scope of ±(0.005–0.350) mm. This discussion permits us to reduce accuracy requirement in calibration for an object with small relief, but the camera platform is located in violent vibration environment. Another theoretical equation of relative RMS of base lines (m S/S) and the equation RMS of start direction are also presented. It is proved that them S/S could be equal to the relative RMS ofm ΔX/ΔX. It is also proved that the permitting RMS of start direction is much bigger than the traditionally used one. Some useful equations of limit errors in close-range photogrammetry are presented as well. Suggestions mentioned above are perhaps beneficial for increasing efficiency, for reducing production cost.展开更多
The purpose of this paper is to discuss the influential factors of iteration accuracy when we use iteration to determine the numerical model for predicting water yield of deep drawdown mines and calculating the ground...The purpose of this paper is to discuss the influential factors of iteration accuracy when we use iteration to determine the numerical model for predicting water yield of deep drawdown mines and calculating the groundwater level. The relationship among the calculation error of groundwater level, the pumping rate, the limit of iteration convergence error, the calculation time, and the aquifer parameters were discussed by using an ideal model. Finally, the water yield of Dianzi iron mine was predicted using the testified numerical model. It is indicated that the calculation error of groundwater level is related to the limit of iteration convergence error, the calculation time and the aquifer parameters, but not to the pumping rate and the variation of groundwater level.展开更多
文摘Close-range photogrammetry is to determine the shape and size of the object, instead of it's absolute position. Therefore, at first, any translation and rotation of the photogrammetric model of the object caused by whole geodesic, photographic and photogrammetric procedures in close-range photogrammetry could not be considered. However, it is necessary to analyze all the reasons which cause the deformations of the shape and size and to present their corresponding theories and equations. This situation, of course, is very different from the conventional topophotogrammetry. In this paper some specific characters of limit errors in close-range photogrammetry are presented in detail, including limit errors for calibration of interior elements for close-range cameras, the limit errors of relative and absolute orientations in close-range cameras, the limit errors of relative and absolute orientations in close-range photogrammetric procedures, and the limit errors of control works in close-range photogrammetry. A theoretical equation of calibration accuracy for close-range camerais given. Relating to the three examples in this paper, their theoretical accuracy requirement of interior elements of camera change in the scope of ±(0.005–0.350) mm. This discussion permits us to reduce accuracy requirement in calibration for an object with small relief, but the camera platform is located in violent vibration environment. Another theoretical equation of relative RMS of base lines (m S/S) and the equation RMS of start direction are also presented. It is proved that them S/S could be equal to the relative RMS ofm ΔX/ΔX. It is also proved that the permitting RMS of start direction is much bigger than the traditionally used one. Some useful equations of limit errors in close-range photogrammetry are presented as well. Suggestions mentioned above are perhaps beneficial for increasing efficiency, for reducing production cost.
文摘The purpose of this paper is to discuss the influential factors of iteration accuracy when we use iteration to determine the numerical model for predicting water yield of deep drawdown mines and calculating the groundwater level. The relationship among the calculation error of groundwater level, the pumping rate, the limit of iteration convergence error, the calculation time, and the aquifer parameters were discussed by using an ideal model. Finally, the water yield of Dianzi iron mine was predicted using the testified numerical model. It is indicated that the calculation error of groundwater level is related to the limit of iteration convergence error, the calculation time and the aquifer parameters, but not to the pumping rate and the variation of groundwater level.