期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
THE APPLICATION OF WEINSTEIN-CHIEN′S METHOD——THE UPPER AND LOWER LIMITS OF FUNDAMENTAL FREQUENCY OF RECTANGULAR PLATES WITH EDGES ARE THE MIXTURE OF SIMPLY SUPPORTED PORTIONS AND CLAMPED PORTIONS
1
作者 陈政清 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 1984年第3期1399-1408,共10页
In this paper, the method of relaxed boundary conditions is applied to rectangular plates with edges which are a sort of the mixture of simply supported portions and clamped portions, so that the lower limit of fundam... In this paper, the method of relaxed boundary conditions is applied to rectangular plates with edges which are a sort of the mixture of simply supported portions and clamped portions, so that the lower limit of fundamental frequency of such plates is evaluated. A kind of polynomial satisfying the displacement boundary conditions is designed, os that it is enabled to evaluate the upper limit of fundamental frequency by Ritz' method. The practical calculation examples solved by these methods have given satisfactory results. At the end of this paper, it is pointed out that the socalled exact solution of such plates usually evaluated by the force superposition method is essentially a kind of lower limit of solution, if the truncated error of series which occurs in actual calculation is considered. 展开更多
关键词 THE UPPER AND LOWER LIMITS OF FUNDAMENTAL frequency OF RECTANGULAR PLATES WITH EDGES ARE THE MIXTURE OF SIMPLY SUPPORTED PORTIONS AND CLAMPED PORTIONS S METHOD THE APPLICATION OF WEINSTEIN-CHIEN
下载PDF
Impact of Frequency Anti-windup Limiter on Synchronization Stability of Grid Feeding Converter
2
作者 Junru Chen Chenchen Ge +3 位作者 Di Qiang Hua Geng Terence O'Donnell Federico Milano 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第5期1676-1687,共12页
Loss of synchronization is one of the main issues for a grid-feeding converter in a weak grid after being subjected to a large disturbance.The synchronous transient is highly nonlinear due to phase movement and freque... Loss of synchronization is one of the main issues for a grid-feeding converter in a weak grid after being subjected to a large disturbance.The synchronous transient is highly nonlinear due to phase movement and frequency limiters.However,none of the previous research has considered the anti-windup PI in the phase-locked loop,which is commonly implemented in reality and introduced as an additional nonlinear transient.This work provides a taxonomy to evaluate and compare the effect of different anti-windup PI limiters on synchronization stability,including clamping,back-calculation and combined method.Different anti-windup PI limiters allocate zeros and poles differently and have different impacts on damping and stability enhancement.A case study implemented in Matlab/Simulink serves to compare the trajectory of the converter phase and frequency using different anti-windup PI in the scenario of both with and without equilibrium points during the fault.Simulation results show that anti-windup PI limiters increase damping during the fault and thus improve the synchronization stability margin. 展开更多
关键词 frequency Limiter(FL) grid-following converter Phase-Locked Loop(PLL) synchronization stability
原文传递
Frequency Control at the Power Sending Side for HVDC Asynchronous Interconnections Between Yunnan Power Grid and the Rest of CSG 被引量:6
3
作者 Hong Rao Wei Wu +4 位作者 Tian Mao Baorong Zhou Chao Hong Yongjun Liu Xiaoshan Wu 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第1期105-113,共9页
For a large-scale high voltage direct current (HVDC)asynchronous interconnected power grid, the frequency issue atthe power sending side under DC faults is a crucial problem.To solve this problem, based on rotor motio... For a large-scale high voltage direct current (HVDC)asynchronous interconnected power grid, the frequency issue atthe power sending side under DC faults is a crucial problem.To solve this problem, based on rotor motion equations, theeffect of unbalanced power on the system frequency under DCfaults is analyzed. The characteristics and dynamic developmentprocess of frequencies after the injection of disturbances areanalyzed. In addition, the actions and coordinated strategies ofvarious frequency control measures are also investigated. Basedon the testing projects of an asynchronous interconnection in theChina Southern Power Grid (CSG), the frequency features arestudied according to the measured PMU data. The outcome showsthat the frequency problem of the Yunnan Power Grid after anasynchronous interconnection can be solved and controlled. Italso shows that the frequency limit control (FLC) is importantfor the frequency regulation of large scale HVDC asynchronousinterconnected DC power grids. As demonstrated, DC FLC caneffectively suppress the deviation of the transient frequency.However, reasonable frequency regulation parameters shouldbe set and other area frequency control measures should becoordinated to maintain the frequency stability of the system. 展开更多
关键词 Asynchronous interconnected power grid DC overload capacity DC frequency limit control frequency stability PMU data
原文传递
Resolution beyond classical limits with spatial frequency heterodyning 被引量:2
4
作者 A.Mudassar A.R.Harvey +1 位作者 A.H.Greenaway J.D.C.Jones 《Chinese Optics Letters》 SCIE EI CAS CSCD 2006年第3期148-151,共4页
A technique for coherent imaging based on spatial frequency heterodyning is described. Three images corresponding to three physical measurements are recorded. For the first measurement, a scene is simply illuminated w... A technique for coherent imaging based on spatial frequency heterodyning is described. Three images corresponding to three physical measurements are recorded. For the first measurement, a scene is simply illuminated with a coherent beam and for measurements 2 and 3, the scene is projected with cosine and sine fringes, respectively. Due to spatial frequency heterodyning, upper and lower side hand information falls in the pass band of the imager. These bands are separated and correct phases and positions are assigned to these bands in the spatial frequency domain. An extension of bandwidth is achieved in the frequency domain and the inverse frequency domain data then give a high resolution coherent image. 展开更多
关键词 Resolution beyond classical limits with spatial frequency heterodyning
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部