[Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived f...[Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived food.[Methods]The samples were extracted with sodium carbonate buffer solution and ethyl acetate,and analyzed by mass spectrometry after solid phase extraction and high performance liquid chromatography separation.[Results]Ten kinds ofα2-receptor agonists showed a good linear relationship in the range of 1-100μg/mL,with the average recovery of over 69%and the relative standard deviation less than 8.32%.The detection limit of 10 kinds of α_(2)-receptor agonists was up to 1μg/kg.[Conclusions]The method has good selectivity and strong anti-interference ability,and can meet the requirements of 10 kinds ofα2-receptor agonists residues in animal derived food.展开更多
In this study, we established a comprehensive method for simultaneous identification and quantification of tetrodotoxin (TTX) in fresh pufferfish tissues and pufferfish-based products using liquid chromatography/qua...In this study, we established a comprehensive method for simultaneous identification and quantification of tetrodotoxin (TTX) in fresh pufferfish tissues and pufferfish-based products using liquid chromatography/quadrupole-linear ion trap mass spectrometry (LC-QqLIT-MS). TTX was extracted by 1% acetic acid-methanol, and most of the lipids were then removed by freezing lipid precipitation, followed by purification and concentration using immunoaffinity columns (IACs). Matrix effects were substantially reduced due to the high specificity of the IACs, and thus, background interference was avoided. Quantitation analysis was therefore performed using an external calibration curve with standards prepared in mobile phase. The method was evaluated by fortifying samples at 1, 10, and 100 ng/g, respectively, and the recoveries ranged from 75.8%--107%, with a relative standard deviation of less than 15%. The TTX calibration curves were linear over the range of 1-1 000 ~tg/L, with a detection limit of 0.3 ng/g and a quantification limit of 1 ng/g. Using this method, samples can be further analyzed using an information- dependent acquisition (IDA) experiment, in the positive mode, from a single liquid chromatography-tandem mass spectrometry injection, which can provide an extra level of confirmation by matching the full product ion spectra acquired for a standard sample with those from an enhanced product ion (EPI) library. The scheduled multiple reaction monitoring method enabled TTX to be screened for, and TTX was positively identified using the IDA and EPI spectra. This method was successfully applied to analyze a total of 206 samples of fresh pufferfish tissues and pufferfish-based products. The results from this study show that the proposed method can be used to quantify and identify TTX in a single run with excellent sensitivity and reproducibility, and is suitable for the analysis of complex matrix pufferfish samples.展开更多
The analysis of hexavalent chromium, Cr(VI), in soil and sediment samples has been predominantly carried out in materials containing elevated levels. Reliable analysis of trace-level of Cr(VI) in sediment samples rema...The analysis of hexavalent chromium, Cr(VI), in soil and sediment samples has been predominantly carried out in materials containing elevated levels. Reliable analysis of trace-level of Cr(VI) in sediment samples remains challenging. Cr(VI) analyses with multipoint calibration and speciated isotope dilution (SID) adapted from U.S. EPA method 6800 were used to measure lower-level Cr(VI) on an ion chromatograph coupled with a tandem mass spectrometer (IC-MS/MS). Lake sediment samples were collected from various locations in Northern Ontario and Cr(VI) was extracted using both alkaline digestion and ethylene diaminetetraacetic acid (EDTA) extraction. Certified reference materials were extracted and analyzed by IC-MS/MS and UV-VIS detection. The SID-MS approach allowed for the quantification of Cr(VI) in samples with concentration levels below 0.5 μg.g-1 wet weight.展开更多
The positive and negative ESI-MS/MS spectra of N-ethoxy(phenyl) phosphoryl amino acids(EPP-AA) were investigated by electrospray ionization(ESI) ion trap mass spectrometry. The fragmentation pathways of [ M + N...The positive and negative ESI-MS/MS spectra of N-ethoxy(phenyl) phosphoryl amino acids(EPP-AA) were investigated by electrospray ionization(ESI) ion trap mass spectrometry. The fragmentation pathways of [ M + Na]^+ and [ M - H]^- ions are proposed and rationalized. The observation may have some potential applications in the interpretation of the MS/MS spectra of novel N-phosphoryl compounds. The complexity of MS/MS spectra of EPP-AA [ M + Na]^+ ions is decreased compared with that of N-dialkyloxyphosphoryl amino acid. Therefore, the new phosphonamidate method may be considered one of the superior methods that can be used in sequencing peptides and proteins extensively.展开更多
The sequence analysis of peptides was performed by nano-electrospray ionization Fourier transform ion cyclotron resonance tandem mass spectrometry(Nano-ESI-FT-ICR-MSn) and several peptides were chosen as examples. W...The sequence analysis of peptides was performed by nano-electrospray ionization Fourier transform ion cyclotron resonance tandem mass spectrometry(Nano-ESI-FT-ICR-MSn) and several peptides were chosen as examples. With the aid of the collision induced dissociation(CID), FT-ICR provides not only precise mass/charge ratio, but also structure information of the selected peptides. The fragment ions were identified according to the observed molecular weights and peptide sequence was determined successfully. So Nano-ESI-FT-ICR-MSn is a useful tool for identification of the amino acid sequence of peptides with high confidence. Besides, a pathway for the dehydration of y ions without amino acids containing carboxylic acid under sustained off-resonance irradiation collision-induced dissociation(SORI-CID) condition was proposed.展开更多
In order to identify the potential nephrotoxic compounds in traditional Chinese medicine Lithospermum erythrorhizon,it was separated into serial fractions according to their polarities.An in vitro method was utilized ...In order to identify the potential nephrotoxic compounds in traditional Chinese medicine Lithospermum erythrorhizon,it was separated into serial fractions according to their polarities.An in vitro method was utilized to determine the nephrotoxicity of these fractions with the help of fluorescence image analysis.As a result,the primary fraction A05 and its secondary fractions C06 "C09 and C12 "C14 were found to have significant toxicity to LLC-PK1 cell line,as determined by the survive rate less than 20% after they were treated with these fractions.These potential nephrotoxic fractions were further analyzed by multistage and high resolution mass spectrometry.The main compounds in these fractions were tentatively identified to be acetylshikonin,isobutyrylshikonin,β,β'-dimethyla-cryloylshikonin,and isovalerylshikonin,which may bring nephrotoxicity.展开更多
Cancer cell spheroids(CCS) are a valuable three-dimensional cell model in cancer studies because they could replicate numerous characteristics of solid tumors. Increasing researches have used matrix-assisted laser des...Cancer cell spheroids(CCS) are a valuable three-dimensional cell model in cancer studies because they could replicate numerous characteristics of solid tumors. Increasing researches have used matrix-assisted laser desorption/ionization mass spectrometry imaging(MALDI-MSI) to investigate the spatial distribution of endogenous compounds(e.g., lipids) in CCS. However, only limited lipid species can be detected owing to a low ion yield by using MALDI. Besides, it is still challenging to fully characterize the structural diversity of lipids due to the existence of isomeric/isobaric species. Here, we carried out the initial application of MALDI coupled with laser-postionization(MALDI-2) and trapped ion mobility spectrometry(TIMS) imaging in HCT116 colon CCS to address these challenges. We demonstrated that MALDI-2 is capable of detecting more number and classes of lipids in HCT116 colon CCS with higher signal intensities than MALDI. TIMS could successfully separate numerous isobaric/isomeric species of lipids in CCS. Interestingly, we found that some isomeric/isobaric species have totally different spatial distributions in colon CCS. Further MS/MS imaging analysis was employed to determine the compositions of fatty acid chains for isomeric species by examining disparities in signal intensities and spatial distributions of product ions. This work stresses the robust ability of TIMS and MALDI-2 imaging in analyzing endogenous lipids in CCS, which could potentially become powerful tools for future cancer studies.展开更多
The study of the calibration of a series of compounds of environmental concern (six perfluoroalkyl compounds (perfluorooctane sulfonic acid and five perfluoroalkyl carboxylic acids), three preservatives (methyl-, ethy...The study of the calibration of a series of compounds of environmental concern (six perfluoroalkyl compounds (perfluorooctane sulfonic acid and five perfluoroalkyl carboxylic acids), three preservatives (methyl-, ethyl- and propylparabens) and the brominated flame retardant hexabromocyclododecane) by LC-MS/MS has been carries out, with a view to their simultaneous determination in samples of environmental interest. In some cases nonlinear calibration curves are obtained, but restricting the concentration range a linear model may be used to fit the data. Residual analysis has been performed in order to verify which models fit the data better, opting for a compromise decision given the apparent complexity of residuals plots. As Box states there are no perfect models (but models that work better than others).展开更多
In proteomics, b and y ions serve as the backbone ions for peptide sequencing in tandem mass spectrometry. Leveraging the existing ion recognition and separation methods, this article proposes a novel ion classificati...In proteomics, b and y ions serve as the backbone ions for peptide sequencing in tandem mass spectrometry. Leveraging the existing ion recognition and separation methods, this article proposes a novel ion classification approach that combines machine learning with graph theory. By incorporating graph features, the method achieves higher accuracy and efficiency in ion type recognition, with the graph features playing a critical role in the classification process. Specifically, the method achieves a recall rate of nearly 90% for b and y ions, demonstrating its effectiveness in pre-processing de novo sequencing and improving its accuracy. The proposed method represents advancement in ion classification and has the potential to improve the accuracy and efficiency of de novo sequencing.展开更多
The fragmentation pathways of two isomers of brassinosteroids,28-homobrassinolide(28-h-BL)and 28-epihomobrassinolide(28-eh-BL),have been investigated by tandem mass spectrometry(MSn,n=1,2,3,4)with the electrospray ion...The fragmentation pathways of two isomers of brassinosteroids,28-homobrassinolide(28-h-BL)and 28-epihomobrassinolide(28-eh-BL),have been investigated by tandem mass spectrometry(MSn,n=1,2,3,4)with the electrospray ionization(ESI) source.The ESI mass spectrometric fragmentation pathways of protonated 28-h-BL and 28-eh-BL were comprehensively elucidated,and the principles revealed in this investigation could potentially be used to identify and distinguish brassinosteroids and their isomers.展开更多
目的考察离子色谱-串联质谱法(ion chromatography-tandem mass spectrometry,IC-MS/MS)和液相色谱-串联质谱法(liquid chromatography-tandem mass spectrometry,LC-MS/MS)在测定不同食品中氯酸盐和高氯酸盐的一致性。方法利用乙腈/水(...目的考察离子色谱-串联质谱法(ion chromatography-tandem mass spectrometry,IC-MS/MS)和液相色谱-串联质谱法(liquid chromatography-tandem mass spectrometry,LC-MS/MS)在测定不同食品中氯酸盐和高氯酸盐的一致性。方法利用乙腈/水(3:2,V:V)提取鸡蛋、奶粉和菠菜中的目标物,经石墨化炭黑(graphitized carbon black,GCB)小柱净化,以IonPac^(TM)AS20离子色谱柱和CSHTMFluoro-Phenyl液相色谱柱为分析柱,三重四极杆质谱仪检测,内标法定量。对两种方法测得的数据进行正态性检验和差异性分析。比较两种方法的保留时间漂移,考察色谱稳定性。对两种方法测得的浓度进行线性回归和Bland-Altman(B-A)图可视化考察方法一致性。结果两种方法测得氯酸盐(高氯酸盐)的质量浓度在1~500(0.1~50.0)μg/L范围内线性良好(r^(2)>0.999)。IC-MS/MS与LC-MS/MS测定高氯酸盐的定量限均为0.5μg/kg,氯酸盐的定量限分别为5.7μg/kg和4.2μg/kg。回收率范围分别为82.3%~107.4%和94.8%~109.4%,相对标准偏差分别为1.5%~13.6%和1.2%~9.6%。IC-MS/MS(LC-MS/MS)测得鸡蛋、奶粉、菠菜中氯酸盐和高氯酸盐的基质效应分别为12.1%(22.1%)、9.0%(27.4%)、-24.0%(-11.8%)和-16.8%(-18.5%)、-18.6%(-28.4%)、-20.2%(-21.1%)。线性回归法显示两种方法测定氯酸盐和高氯酸盐浓度的回归曲线斜率分别为1.0144和1.0908。B-A图显示绝大多数数据点位于平均值±1.96标准偏差范围。结论两种方法的准确度和精密度均符合化学检验方法验证通则的要求,两种方法测得的氯酸盐、高氯酸盐浓度结果基本一致,但氯酸盐在LC-MS/MS系统中的保留时间稳定性更好,IC-MS/MS在测定食品中氯酸盐、高氯酸盐时的抗基质干扰能力更强。展开更多
基金Supported by Scientific Research Project of Dalian Customs(2022DK09).
文摘[Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived food.[Methods]The samples were extracted with sodium carbonate buffer solution and ethyl acetate,and analyzed by mass spectrometry after solid phase extraction and high performance liquid chromatography separation.[Results]Ten kinds ofα2-receptor agonists showed a good linear relationship in the range of 1-100μg/mL,with the average recovery of over 69%and the relative standard deviation less than 8.32%.The detection limit of 10 kinds of α_(2)-receptor agonists was up to 1μg/kg.[Conclusions]The method has good selectivity and strong anti-interference ability,and can meet the requirements of 10 kinds ofα2-receptor agonists residues in animal derived food.
基金Supported by the National Natural Science Foundation of China(No.41106109)the China National Food Safety Standards Development Project(No.ZHENGHE-2015-356)
文摘In this study, we established a comprehensive method for simultaneous identification and quantification of tetrodotoxin (TTX) in fresh pufferfish tissues and pufferfish-based products using liquid chromatography/quadrupole-linear ion trap mass spectrometry (LC-QqLIT-MS). TTX was extracted by 1% acetic acid-methanol, and most of the lipids were then removed by freezing lipid precipitation, followed by purification and concentration using immunoaffinity columns (IACs). Matrix effects were substantially reduced due to the high specificity of the IACs, and thus, background interference was avoided. Quantitation analysis was therefore performed using an external calibration curve with standards prepared in mobile phase. The method was evaluated by fortifying samples at 1, 10, and 100 ng/g, respectively, and the recoveries ranged from 75.8%--107%, with a relative standard deviation of less than 15%. The TTX calibration curves were linear over the range of 1-1 000 ~tg/L, with a detection limit of 0.3 ng/g and a quantification limit of 1 ng/g. Using this method, samples can be further analyzed using an information- dependent acquisition (IDA) experiment, in the positive mode, from a single liquid chromatography-tandem mass spectrometry injection, which can provide an extra level of confirmation by matching the full product ion spectra acquired for a standard sample with those from an enhanced product ion (EPI) library. The scheduled multiple reaction monitoring method enabled TTX to be screened for, and TTX was positively identified using the IDA and EPI spectra. This method was successfully applied to analyze a total of 206 samples of fresh pufferfish tissues and pufferfish-based products. The results from this study show that the proposed method can be used to quantify and identify TTX in a single run with excellent sensitivity and reproducibility, and is suitable for the analysis of complex matrix pufferfish samples.
文摘The analysis of hexavalent chromium, Cr(VI), in soil and sediment samples has been predominantly carried out in materials containing elevated levels. Reliable analysis of trace-level of Cr(VI) in sediment samples remains challenging. Cr(VI) analyses with multipoint calibration and speciated isotope dilution (SID) adapted from U.S. EPA method 6800 were used to measure lower-level Cr(VI) on an ion chromatograph coupled with a tandem mass spectrometer (IC-MS/MS). Lake sediment samples were collected from various locations in Northern Ontario and Cr(VI) was extracted using both alkaline digestion and ethylene diaminetetraacetic acid (EDTA) extraction. Certified reference materials were extracted and analyzed by IC-MS/MS and UV-VIS detection. The SID-MS approach allowed for the quantification of Cr(VI) in samples with concentration levels below 0.5 μg.g-1 wet weight.
基金Supported by the Education Department of Henan Province(No. 200510459015).
文摘The positive and negative ESI-MS/MS spectra of N-ethoxy(phenyl) phosphoryl amino acids(EPP-AA) were investigated by electrospray ionization(ESI) ion trap mass spectrometry. The fragmentation pathways of [ M + Na]^+ and [ M - H]^- ions are proposed and rationalized. The observation may have some potential applications in the interpretation of the MS/MS spectra of novel N-phosphoryl compounds. The complexity of MS/MS spectra of EPP-AA [ M + Na]^+ ions is decreased compared with that of N-dialkyloxyphosphoryl amino acid. Therefore, the new phosphonamidate method may be considered one of the superior methods that can be used in sequencing peptides and proteins extensively.
基金Supported by the National Natural Science Foundation of China(No.20675079)
文摘The sequence analysis of peptides was performed by nano-electrospray ionization Fourier transform ion cyclotron resonance tandem mass spectrometry(Nano-ESI-FT-ICR-MSn) and several peptides were chosen as examples. With the aid of the collision induced dissociation(CID), FT-ICR provides not only precise mass/charge ratio, but also structure information of the selected peptides. The fragment ions were identified according to the observed molecular weights and peptide sequence was determined successfully. So Nano-ESI-FT-ICR-MSn is a useful tool for identification of the amino acid sequence of peptides with high confidence. Besides, a pathway for the dehydration of y ions without amino acids containing carboxylic acid under sustained off-resonance irradiation collision-induced dissociation(SORI-CID) condition was proposed.
基金Supported by the National Key Scientific and Technological Project of China(No.2009ZX09502-012)the Research Fund for the Doctoral Program of Higher Education of China(No.20090101110126)the Zhejiang Province Science and Technology Plan Project,China(No.2008C23065)
文摘In order to identify the potential nephrotoxic compounds in traditional Chinese medicine Lithospermum erythrorhizon,it was separated into serial fractions according to their polarities.An in vitro method was utilized to determine the nephrotoxicity of these fractions with the help of fluorescence image analysis.As a result,the primary fraction A05 and its secondary fractions C06 "C09 and C12 "C14 were found to have significant toxicity to LLC-PK1 cell line,as determined by the survive rate less than 20% after they were treated with these fractions.These potential nephrotoxic fractions were further analyzed by multistage and high resolution mass spectrometry.The main compounds in these fractions were tentatively identified to be acetylshikonin,isobutyrylshikonin,β,β'-dimethyla-cryloylshikonin,and isovalerylshikonin,which may bring nephrotoxicity.
基金supported by the National Natural Science Foundation of China (Nos.22036001, 22276034 and 22106130)。
文摘Cancer cell spheroids(CCS) are a valuable three-dimensional cell model in cancer studies because they could replicate numerous characteristics of solid tumors. Increasing researches have used matrix-assisted laser desorption/ionization mass spectrometry imaging(MALDI-MSI) to investigate the spatial distribution of endogenous compounds(e.g., lipids) in CCS. However, only limited lipid species can be detected owing to a low ion yield by using MALDI. Besides, it is still challenging to fully characterize the structural diversity of lipids due to the existence of isomeric/isobaric species. Here, we carried out the initial application of MALDI coupled with laser-postionization(MALDI-2) and trapped ion mobility spectrometry(TIMS) imaging in HCT116 colon CCS to address these challenges. We demonstrated that MALDI-2 is capable of detecting more number and classes of lipids in HCT116 colon CCS with higher signal intensities than MALDI. TIMS could successfully separate numerous isobaric/isomeric species of lipids in CCS. Interestingly, we found that some isomeric/isobaric species have totally different spatial distributions in colon CCS. Further MS/MS imaging analysis was employed to determine the compositions of fatty acid chains for isomeric species by examining disparities in signal intensities and spatial distributions of product ions. This work stresses the robust ability of TIMS and MALDI-2 imaging in analyzing endogenous lipids in CCS, which could potentially become powerful tools for future cancer studies.
文摘The study of the calibration of a series of compounds of environmental concern (six perfluoroalkyl compounds (perfluorooctane sulfonic acid and five perfluoroalkyl carboxylic acids), three preservatives (methyl-, ethyl- and propylparabens) and the brominated flame retardant hexabromocyclododecane) by LC-MS/MS has been carries out, with a view to their simultaneous determination in samples of environmental interest. In some cases nonlinear calibration curves are obtained, but restricting the concentration range a linear model may be used to fit the data. Residual analysis has been performed in order to verify which models fit the data better, opting for a compromise decision given the apparent complexity of residuals plots. As Box states there are no perfect models (but models that work better than others).
文摘In proteomics, b and y ions serve as the backbone ions for peptide sequencing in tandem mass spectrometry. Leveraging the existing ion recognition and separation methods, this article proposes a novel ion classification approach that combines machine learning with graph theory. By incorporating graph features, the method achieves higher accuracy and efficiency in ion type recognition, with the graph features playing a critical role in the classification process. Specifically, the method achieves a recall rate of nearly 90% for b and y ions, demonstrating its effectiveness in pre-processing de novo sequencing and improving its accuracy. The proposed method represents advancement in ion classification and has the potential to improve the accuracy and efficiency of de novo sequencing.
基金supported by the National Natural Science Foundation of China(90717002 and 90717002)the Fundamental Research Funds for the Central Universitiesthe Project Sponsored by the Scientific Research Fundation for the Returned Overseas Chinese Scholars,Education Ministry of China
文摘The fragmentation pathways of two isomers of brassinosteroids,28-homobrassinolide(28-h-BL)and 28-epihomobrassinolide(28-eh-BL),have been investigated by tandem mass spectrometry(MSn,n=1,2,3,4)with the electrospray ionization(ESI) source.The ESI mass spectrometric fragmentation pathways of protonated 28-h-BL and 28-eh-BL were comprehensively elucidated,and the principles revealed in this investigation could potentially be used to identify and distinguish brassinosteroids and their isomers.
文摘目的考察离子色谱-串联质谱法(ion chromatography-tandem mass spectrometry,IC-MS/MS)和液相色谱-串联质谱法(liquid chromatography-tandem mass spectrometry,LC-MS/MS)在测定不同食品中氯酸盐和高氯酸盐的一致性。方法利用乙腈/水(3:2,V:V)提取鸡蛋、奶粉和菠菜中的目标物,经石墨化炭黑(graphitized carbon black,GCB)小柱净化,以IonPac^(TM)AS20离子色谱柱和CSHTMFluoro-Phenyl液相色谱柱为分析柱,三重四极杆质谱仪检测,内标法定量。对两种方法测得的数据进行正态性检验和差异性分析。比较两种方法的保留时间漂移,考察色谱稳定性。对两种方法测得的浓度进行线性回归和Bland-Altman(B-A)图可视化考察方法一致性。结果两种方法测得氯酸盐(高氯酸盐)的质量浓度在1~500(0.1~50.0)μg/L范围内线性良好(r^(2)>0.999)。IC-MS/MS与LC-MS/MS测定高氯酸盐的定量限均为0.5μg/kg,氯酸盐的定量限分别为5.7μg/kg和4.2μg/kg。回收率范围分别为82.3%~107.4%和94.8%~109.4%,相对标准偏差分别为1.5%~13.6%和1.2%~9.6%。IC-MS/MS(LC-MS/MS)测得鸡蛋、奶粉、菠菜中氯酸盐和高氯酸盐的基质效应分别为12.1%(22.1%)、9.0%(27.4%)、-24.0%(-11.8%)和-16.8%(-18.5%)、-18.6%(-28.4%)、-20.2%(-21.1%)。线性回归法显示两种方法测定氯酸盐和高氯酸盐浓度的回归曲线斜率分别为1.0144和1.0908。B-A图显示绝大多数数据点位于平均值±1.96标准偏差范围。结论两种方法的准确度和精密度均符合化学检验方法验证通则的要求,两种方法测得的氯酸盐、高氯酸盐浓度结果基本一致,但氯酸盐在LC-MS/MS系统中的保留时间稳定性更好,IC-MS/MS在测定食品中氯酸盐、高氯酸盐时的抗基质干扰能力更强。