Linear scan computed tomography (LCT) is of great benefit to online industrial scanning and security inspection due to its characteristics of straight-line source trajectory and high scanning speed. However, in prac...Linear scan computed tomography (LCT) is of great benefit to online industrial scanning and security inspection due to its characteristics of straight-line source trajectory and high scanning speed. However, in practical applications of LCT, there are challenges to image reconstruction due to limited-angle and insufficient data. In this paper, a new reconstruction algorithm based on total-variation (TV) minimization is developed to reconstruct images from limited-angle and insufficient data in LCT. The main idea of our approach is to reformulate a TV problem as a linear equality constrained problem where the objective function is separable, and then minimize its augmented Lagrangian function by using alternating direction method (ADM) to solve subproblems. The proposed method is robust and efficient in the task of reconstruction by showing the convergence of ADM. The numerical simulations and real data reconstructions show that the proposed reconstruction method brings reasonable performance and outperforms some previous ones when applied to an LCT imaging problem.展开更多
In this paper an electron microscopic image of diameter 80 – 120 nm and of dimensions 180×220 pixels is used as a test object to fabricate Fresnel zone plate hologram. The author proposes a different set of pupi...In this paper an electron microscopic image of diameter 80 – 120 nm and of dimensions 180×220 pixels is used as a test object to fabricate Fresnel zone plate hologram. The author proposes a different set of pupils: one pupil still being a delta function and the other being a function of = sqrt(x2+y2). The obtained reconstructed images in case of scanning holography are investigated.展开更多
It is difficult to develop image reconstruction algorithms for tomographic gamma scanning based on drummed radioactive residues or wastes.In this paper,a novel reconstruction algorithm of transmission image for tomogr...It is difficult to develop image reconstruction algorithms for tomographic gamma scanning based on drummed radioactive residues or wastes.In this paper,a novel reconstruction algorithm of transmission image for tomographic gamma scanning is proposed.It is based on the conventional transmission equation and equivalent gamma-ray track length modified by a Monte Carlo method.The algorithm is implemented by simulating the samples on the established platform.For the verification experiments of the algorithm,several cubic voxel samples were designed and manufactured.Experimental tests were conducted.The tomographic gamma scanning of transmission images is compared with the linear attenuation coefficients by the simulated values and experimental data with the algorithm and the reference values.The results show that the absolute relative errors of the reconstructed images are less than 5%.展开更多
CeO2/TiO2 composite nanoparticles with different Ce/Ti molar ratios have been successfully synthesized via sol-gel method. It was found that the band gap of the nanocomposite is tunable by varying Ce/Ti content. The n...CeO2/TiO2 composite nanoparticles with different Ce/Ti molar ratios have been successfully synthesized via sol-gel method. It was found that the band gap of the nanocomposite is tunable by varying Ce/Ti content. The nonlinear response of the sample was studied by using the nanosecond laser pulses from a Q switched Nd:Yag laser employing the Z-scan method. Open aperture Z-scan experiment revealed that with the increase in the CeO2 amount in the nanocomposite, the non-linearity of the composite increases, and it was assumed that this could be due to the modification of TiO2 dipole symmetry by the addition of CeO2. Closed aperture Z-scan experiment showed that when the CeO2 amount increases, positive nonlinear refraction decreases, and this could be attributed to the increase in the two photon absorption which subsequently suppresses the nonlinear refraction.展开更多
基金the National High Technology Research and Development Program of China(Grant No.2012AA011603)
文摘Linear scan computed tomography (LCT) is of great benefit to online industrial scanning and security inspection due to its characteristics of straight-line source trajectory and high scanning speed. However, in practical applications of LCT, there are challenges to image reconstruction due to limited-angle and insufficient data. In this paper, a new reconstruction algorithm based on total-variation (TV) minimization is developed to reconstruct images from limited-angle and insufficient data in LCT. The main idea of our approach is to reformulate a TV problem as a linear equality constrained problem where the objective function is separable, and then minimize its augmented Lagrangian function by using alternating direction method (ADM) to solve subproblems. The proposed method is robust and efficient in the task of reconstruction by showing the convergence of ADM. The numerical simulations and real data reconstructions show that the proposed reconstruction method brings reasonable performance and outperforms some previous ones when applied to an LCT imaging problem.
文摘In this paper an electron microscopic image of diameter 80 – 120 nm and of dimensions 180×220 pixels is used as a test object to fabricate Fresnel zone plate hologram. The author proposes a different set of pupils: one pupil still being a delta function and the other being a function of = sqrt(x2+y2). The obtained reconstructed images in case of scanning holography are investigated.
基金Supported by the Foundation for Returned Oversea Chinese Scholars(No.33)
文摘It is difficult to develop image reconstruction algorithms for tomographic gamma scanning based on drummed radioactive residues or wastes.In this paper,a novel reconstruction algorithm of transmission image for tomographic gamma scanning is proposed.It is based on the conventional transmission equation and equivalent gamma-ray track length modified by a Monte Carlo method.The algorithm is implemented by simulating the samples on the established platform.For the verification experiments of the algorithm,several cubic voxel samples were designed and manufactured.Experimental tests were conducted.The tomographic gamma scanning of transmission images is compared with the linear attenuation coefficients by the simulated values and experimental data with the algorithm and the reference values.The results show that the absolute relative errors of the reconstructed images are less than 5%.
基金Project supported by the Department of Science and Technology(DST),Govt.of India
文摘CeO2/TiO2 composite nanoparticles with different Ce/Ti molar ratios have been successfully synthesized via sol-gel method. It was found that the band gap of the nanocomposite is tunable by varying Ce/Ti content. The nonlinear response of the sample was studied by using the nanosecond laser pulses from a Q switched Nd:Yag laser employing the Z-scan method. Open aperture Z-scan experiment revealed that with the increase in the CeO2 amount in the nanocomposite, the non-linearity of the composite increases, and it was assumed that this could be due to the modification of TiO2 dipole symmetry by the addition of CeO2. Closed aperture Z-scan experiment showed that when the CeO2 amount increases, positive nonlinear refraction decreases, and this could be attributed to the increase in the two photon absorption which subsequently suppresses the nonlinear refraction.