Liquefied natural gas(LNG)is regarded as one of the cleanest fossil fuel and has experienced significant developments in recent years.The liquefaction process of natural gas is energy-intensive,while the regasificatio...Liquefied natural gas(LNG)is regarded as one of the cleanest fossil fuel and has experienced significant developments in recent years.The liquefaction process of natural gas is energy-intensive,while the regasification of LNG gives out a huge amount of waste energy since plenty of high grade cold energy(-160℃)from LNG is released to sea water directly in most cases,and also sometimes LNG is burned for regasification.On the other hand,liquid air energy storage(LAES)is an emerging energy storage technology for applications such as peak load shifting of power grids,which generates 30%-40%of compression heat(-200℃).Such heat could lead to energy waste if not recovered and used.The recovery of the compression heat is technically feasible but requires additional capital investment,which may not always be economically attractive.Therefore,we propose a power plant for recovering the waste cryogenic energy from LNG regasification and compression heat from the LAES.The challenge for such a power plant is the wide working temperature range between the low-temperature exergy source(-160℃)and heat source(-200℃).Nitrogen and argon are proposed as the working fluids to address the challenge.Thermodynamic analyses are carried out and the results show that the power plant could achieve a thermal efficiency of 27%and 19%and an exergy efficiency of 40%and 28%for nitrogen and argon,respectively.Here,with the nitrogen as working fluid undergoes a complete Brayton Cycle,while the argon based power plant goes through a combined Brayton and Rankine Cycle.Besides,the economic analysis shows that the payback period of this proposed system is only 2.2 years,utilizing the excess heat from a 5 MW/40 MWh LAES system.The findings suggest that the waste energy based power plant could be co-located with the LNG terminal and LAES plant,providing additional power output and reducing energy waste.展开更多
Liquid air energy storage(LAES)has been regarded as a large-scale electrical storage technology.In this paper,we first investigate the performance of the current LAES(termed as a baseline LAES)over a far wider range o...Liquid air energy storage(LAES)has been regarded as a large-scale electrical storage technology.In this paper,we first investigate the performance of the current LAES(termed as a baseline LAES)over a far wider range of charging pressure(1 to 21 MPa).Our analyses show that the baseline LAES could achieve an electrical round trip efficiency(e RTE)above 60%at a high charging pressure of 19 MPa.The baseline LAES,however,produces a large amount of excess heat particularly at low charging pressures with the maximum occurred at~1 MPa.Hence,the performance of the baseline LAES,especially at low charging pressures,is underestimated by only considering electrical energy in all the previous research.The performance of the baseline LAES with excess heat is then evaluated which gives a high e RTE even at lower charging pressures;the local maximum of 62%is achieved at~4 MPa.As a result of the above,a hybrid LAES system is proposed to provide cooling,heating,hot water and power.To evaluate the performance of the hybrid LAES system,three performance indicators are considered:nominal-electrical round trip efficiency(ne RTE),primary energy savings and avoided carbon dioxide emissions.Our results show that the hybrid LAES can achieve a high ne RTE between 52%and 76%,with the maximum at~5 MPa.For a given size of hybrid LAES(1 MW×8 h),the primary energy savings and avoided carbon dioxide emissions are up to 12.1 MWh and 2.3 ton,respectively.These new findings suggest,for the first time,that small-scale LAES systems could be best operated at lower charging pressures and the technologies have a great potential for applications in local decentralized micro energy networks.展开更多
Liquid Air Energy Storage(LAES)is at pilot scale.Air cooling and liquefaction stores energy;reheating revaporises the air at pressure,powering a turbine or engine(Ameel et al.,2013).Liquefaction requires water&CO2...Liquid Air Energy Storage(LAES)is at pilot scale.Air cooling and liquefaction stores energy;reheating revaporises the air at pressure,powering a turbine or engine(Ameel et al.,2013).Liquefaction requires water&CO2 removal,preventing ice fouling.This paper proposes subsequent geological storage of this CO2–offering a novel Carbon Dioxide Removal(CDR)by-product,for the energy storage industry.It additionally assesses the scale constraint and economic opportunity offered by implementing this CDR approach.Similarly,established Compressed Air Energy Storage(CAES)uses air compression and subsequent expansion.CAES could also add CO2 scrubbing and subsequent storage,at extra cost.CAES stores fewer joules per kilogram of air than LAES–potentially scrubbing more CO2 per joule stored.Operational LAES/CAES technologies cannot offer full-scale CDR this century(Stocker et al.,2014),yet they could offer around 4%of projected CO2 disposals for LAES and<25%for current-technology CAES.LAES CDR could reach trillion-dollar scale this century(20 billion USD/year,to first order).A larger,less certain commercial CDR opportunity exists for modified conventional CAES,due to additional equipment requirements.CDR may be commercially critical for LAES/CAES usage growth,and the necessary infrastructure may influence plant scaling and placement.A suggested design for low-pressure CAES theoretically offers global-scale CDR potential within a century(ignoring siting constraints)–but this must be costed against competing CDR and energy storage technologies.展开更多
Suitable control of the humidity can contribute to electric energy savings. However, the present dehumidification system has many weak points. The liquid desiccant air-conditioning system has recently gained growing i...Suitable control of the humidity can contribute to electric energy savings. However, the present dehumidification system has many weak points. The liquid desiccant air-conditioning system has recently gained growing interest from the stand point of reducing energy consumption during dehumidification. In order to find the appropriate ionic liquids(ILs) as a desiccant for the liquid desiccant air-conditioner system, we conducted a systematic evaluation of the humidification capability of 16 types of ILs. Among the tested ILs, tributyl(methyl)phosphonium dimethyl phosphate([P4441][DMPO_4]) exhibited the best dehumidification capacity and had a less corrosive effect on four types of metals as possible piping materials. It should be noted that this [P_(4441)][DMPO_4] has a very stable nature and produced no odor while conducting the experiment and storing for over 1 year at room temperature under ambient conditions. Furthermore, it was revealed that a 77%(w/w) aqueous solution of [P4441][DMPO_4] worked as an efficient desiccant liquid for the liquid desiccant air-conditioner system.展开更多
AIM: To report the results of rhegmatogenous retinal detachment(RRD) repair after pars plana vitrectomy(PPV) without operative use of heavy liquid, and utilizing air tamponade in selected cases.METHODS: RRD pati...AIM: To report the results of rhegmatogenous retinal detachment(RRD) repair after pars plana vitrectomy(PPV) without operative use of heavy liquid, and utilizing air tamponade in selected cases.METHODS: RRD patients without severity of proliferative vitreoretinopathy C2 or more underwent PPV without operative use of heavy liquid, and utilizing air tamponade were consecutively enrolled. Alternative postoperative facedown position or lateral position was required for 3-5 d.RESULTS: Totally 36 eyes of 36 patients(24 males, 66.7%) aged 53.8±10.9 y underwent this modified surgery. The mean number of retinal break was 2.1±1.3. Most of the eyes(29, 80.6%) had retinal detachment involving more than one quadrant. Twenty-two(61.1%) eyes with cataract had combined phacoemulsification and intraocular lens implantation. The mean follow up time was 4.6±1.8 mo. Two eyes with retinal redetachment underwent a second retinal repair surgery with silicone oil tamponade, yielding the primary reattachment rate to 94.4%(34/36). Six(16.7%) eyes had intraocular pressure higher than 25 mm Hg. The visual acuity(logMAR) improved from 0.98±0.74 preoperatively to 0.52±0.31 postoperatively(P〈0.001). CONCLUSION: The success rate of this modified retinal repair surgery is comparable with traditional surgery. This technique can be considered for certain retinal detachment patients, since its apparent advantages included lower surgical complications, reduced surgery expenditure, shorter time for postoperative facedown position, and avoiding silicone oil removal surgery.展开更多
Insulation is one of the most important parts in a high voltage equipment.There are gaseous,liquid and solid insulations which are commonly used.In a high voltage transformer for example the insulating materials are a...Insulation is one of the most important parts in a high voltage equipment.There are gaseous,liquid and solid insulations which are commonly used.In a high voltage transformer for example the insulating materials are all used.During operation of a high voltage equipment high electric stress may occur.Under extreme condition failure of the insulation may take place.Excessive electric field in air may cause corona discharges while in liquid insulation discharges may take place in the form of streamer.This paper reports experimental results on the corona and streamer discharges in air and silicone oil.The discharges were artificially generated around a needle tip in a needle-plane electrode system with gap length of 4 mm under sinusoidal and triangular voltages.The needle was made of steel with tip radius of 3 μm and curvature angle of 30°.The needle was made by Ogura Jewelry.The discharge pulses were measured using personal-computer based partial discharge(PD)measurement system with sensitivity of better than 0.5 pC.The system is able to measure discharge in time sequential.Phase-resolved analysis of the discharges was done to interpret the physical processes behind the discharges.The experimental results showed that corona discharges took place at negative half cycles.The discharges were concentrated around 270° of phase angle of applied voltage.The discharge magnitude and discharge number of corona clearly dependent on the instantaneous of applied voltage.These were strongly supported by the application of triangular voltage.Streamer discharges occurred at both positive and negative half cycles.The discharges pulses concentrated around the peak of applied voltage at phase angle of 90° and 270°.Experimental results under sinusoidal and triangular voltages revealed that streamer discharge magnitude as well as probability of occurrence was strongly dependent on the instantaneous applied voltage.展开更多
Triheptyl cellulose/ethyl cellulose(3/97)binary blend membranes were prepared from tetrahydrofuran,chloroform and dichloromethane solutions and their air separation capabit- ities were studied at different temperature...Triheptyl cellulose/ethyl cellulose(3/97)binary blend membranes were prepared from tetrahydrofuran,chloroform and dichloromethane solutions and their air separation capabit- ities were studied at different temperatures.With increasing temperature from 25 to 85℃,the flux QOEA of O_2-enriched air(OEA),O_2 permselectivity and the O_2 concentration Yo_2 in the OEA all increase.The membranes show a unique trend in their Yo_2~QOEA relationship,that is,the air separation capability increases simultaneously with the OEA permeation capability.The magnitudes of QOEA and Yo_2 for 17μm-thick membrane after the testg time of 36hours at 70℃ are 5×10^(-4)cm^3 (STP)/s·cm^2 and 37.6%,respectively.The air separation capability depends slightly on membrane forming solvents.展开更多
A multi-tube air-lift loop reactor (MT-ALR) is presented in this paper. Based on the energy conservation, a mathematical model describing the liquid circulation flow rate was developed, which was determined by gas vel...A multi-tube air-lift loop reactor (MT-ALR) is presented in this paper. Based on the energy conservation, a mathematical model describing the liquid circulation flow rate was developed, which was determined by gas velocity, the cross areas of riser and downcomer, gas hold-up and the local frictional loss coefficient. The experimental data indicate that either increase of gas flow rate or reduction of the downcomer diameter contributes to higher liquid circulation rate. The correlation between total and the local frictional loss coefficients was also established.Effects of gas flowrate in two risers and diameter of downcomer on the liquid circulation rate were examined. The value of total frictional loss coefficient was measured as a function of the cross area of downcomer and independent of the gas flow rate. The calculated results of liquid circulation rates agreed well with the experimental data with an average relative error of 9.6%.展开更多
The liquid phase turbulent structure of an air-water bubbly horizontal flow in a circular pipe has been investigated experimentally. Three-dimensional measurements were implemented with two "X" type probes o...The liquid phase turbulent structure of an air-water bubbly horizontal flow in a circular pipe has been investigated experimentally. Three-dimensional measurements were implemented with two "X" type probes oriented in different planes, and local liquid-phase velocities and turbulent stresses were simultaneously obtained. Systematic measurements were conducted covering a range of local void fraction from 0 to 11.7%. The important experiment results and parametric trends are summarized and discussed.展开更多
浮式液化天然气生产储卸装置(floating liquefied natural gas system,FLNG)特种液货船作为开发海上天然气田的新式装置,极大的方便了对处于深海的气田的开发利用,该文以“Prelude”号FLNG作为母船,提出一种新型FLNG低温能量管理系统。...浮式液化天然气生产储卸装置(floating liquefied natural gas system,FLNG)特种液货船作为开发海上天然气田的新式装置,极大的方便了对处于深海的气田的开发利用,该文以“Prelude”号FLNG作为母船,提出一种新型FLNG低温能量管理系统。该系统主要利用液态空气作为媒介储存和释放能量,通过液态空气冷能与混合制冷循环相结合实现天然气液化过程,在提高LNG生产性能的同时集成了CO_(2)液化循环和电力的生产,通过CO_(2)液化和剩余冷能发电提高系统的输出性能,实现了FLNG船舶冷能的多级利用,也为FLNG船舶冷能利用提供新方法,新途径。所提系统相较于基准模型具有更好的性能,在7.04年可实现成本回收。最后采用多目标性能优化,进一步提高系统㶲效率达60.67%,同时降低约2.3%的成本。该FLNG低温能量管理系统有高效、低耗、稳收益、低碳化等特点,可更好优化海上LNG供应链,促进航运业“双碳”发展。展开更多
基金partial support of UK EPSRC under grants EP/V012053/1,EP/S032622/1,EP/P004709/1,EP/P003605/1 and EP/N032888/1the British Council under 2020-RLWK12-10478 and 2019-RLWK11-10724。
文摘Liquefied natural gas(LNG)is regarded as one of the cleanest fossil fuel and has experienced significant developments in recent years.The liquefaction process of natural gas is energy-intensive,while the regasification of LNG gives out a huge amount of waste energy since plenty of high grade cold energy(-160℃)from LNG is released to sea water directly in most cases,and also sometimes LNG is burned for regasification.On the other hand,liquid air energy storage(LAES)is an emerging energy storage technology for applications such as peak load shifting of power grids,which generates 30%-40%of compression heat(-200℃).Such heat could lead to energy waste if not recovered and used.The recovery of the compression heat is technically feasible but requires additional capital investment,which may not always be economically attractive.Therefore,we propose a power plant for recovering the waste cryogenic energy from LNG regasification and compression heat from the LAES.The challenge for such a power plant is the wide working temperature range between the low-temperature exergy source(-160℃)and heat source(-200℃).Nitrogen and argon are proposed as the working fluids to address the challenge.Thermodynamic analyses are carried out and the results show that the power plant could achieve a thermal efficiency of 27%and 19%and an exergy efficiency of 40%and 28%for nitrogen and argon,respectively.Here,with the nitrogen as working fluid undergoes a complete Brayton Cycle,while the argon based power plant goes through a combined Brayton and Rankine Cycle.Besides,the economic analysis shows that the payback period of this proposed system is only 2.2 years,utilizing the excess heat from a 5 MW/40 MWh LAES system.The findings suggest that the waste energy based power plant could be co-located with the LNG terminal and LAES plant,providing additional power output and reducing energy waste.
基金the partial support from UK EPSRC Manifest Project under EP/N032888/1,EP/P003605/1a UK FCO Science&Innovation Network grant(Global Partnerships Fund)an IGI/IAS Global Challenges Funding(IGI/IAS ID 3041)。
文摘Liquid air energy storage(LAES)has been regarded as a large-scale electrical storage technology.In this paper,we first investigate the performance of the current LAES(termed as a baseline LAES)over a far wider range of charging pressure(1 to 21 MPa).Our analyses show that the baseline LAES could achieve an electrical round trip efficiency(e RTE)above 60%at a high charging pressure of 19 MPa.The baseline LAES,however,produces a large amount of excess heat particularly at low charging pressures with the maximum occurred at~1 MPa.Hence,the performance of the baseline LAES,especially at low charging pressures,is underestimated by only considering electrical energy in all the previous research.The performance of the baseline LAES with excess heat is then evaluated which gives a high e RTE even at lower charging pressures;the local maximum of 62%is achieved at~4 MPa.As a result of the above,a hybrid LAES system is proposed to provide cooling,heating,hot water and power.To evaluate the performance of the hybrid LAES system,three performance indicators are considered:nominal-electrical round trip efficiency(ne RTE),primary energy savings and avoided carbon dioxide emissions.Our results show that the hybrid LAES can achieve a high ne RTE between 52%and 76%,with the maximum at~5 MPa.For a given size of hybrid LAES(1 MW×8 h),the primary energy savings and avoided carbon dioxide emissions are up to 12.1 MWh and 2.3 ton,respectively.These new findings suggest,for the first time,that small-scale LAES systems could be best operated at lower charging pressures and the technologies have a great potential for applications in local decentralized micro energy networks.
文摘Liquid Air Energy Storage(LAES)is at pilot scale.Air cooling and liquefaction stores energy;reheating revaporises the air at pressure,powering a turbine or engine(Ameel et al.,2013).Liquefaction requires water&CO2 removal,preventing ice fouling.This paper proposes subsequent geological storage of this CO2–offering a novel Carbon Dioxide Removal(CDR)by-product,for the energy storage industry.It additionally assesses the scale constraint and economic opportunity offered by implementing this CDR approach.Similarly,established Compressed Air Energy Storage(CAES)uses air compression and subsequent expansion.CAES could also add CO2 scrubbing and subsequent storage,at extra cost.CAES stores fewer joules per kilogram of air than LAES–potentially scrubbing more CO2 per joule stored.Operational LAES/CAES technologies cannot offer full-scale CDR this century(Stocker et al.,2014),yet they could offer around 4%of projected CO2 disposals for LAES and<25%for current-technology CAES.LAES CDR could reach trillion-dollar scale this century(20 billion USD/year,to first order).A larger,less certain commercial CDR opportunity exists for modified conventional CAES,due to additional equipment requirements.CDR may be commercially critical for LAES/CAES usage growth,and the necessary infrastructure may influence plant scaling and placement.A suggested design for low-pressure CAES theoretically offers global-scale CDR potential within a century(ignoring siting constraints)–but this must be costed against competing CDR and energy storage technologies.
基金supported by a fund for environmental research from Tottori University
文摘Suitable control of the humidity can contribute to electric energy savings. However, the present dehumidification system has many weak points. The liquid desiccant air-conditioning system has recently gained growing interest from the stand point of reducing energy consumption during dehumidification. In order to find the appropriate ionic liquids(ILs) as a desiccant for the liquid desiccant air-conditioner system, we conducted a systematic evaluation of the humidification capability of 16 types of ILs. Among the tested ILs, tributyl(methyl)phosphonium dimethyl phosphate([P4441][DMPO_4]) exhibited the best dehumidification capacity and had a less corrosive effect on four types of metals as possible piping materials. It should be noted that this [P_(4441)][DMPO_4] has a very stable nature and produced no odor while conducting the experiment and storing for over 1 year at room temperature under ambient conditions. Furthermore, it was revealed that a 77%(w/w) aqueous solution of [P4441][DMPO_4] worked as an efficient desiccant liquid for the liquid desiccant air-conditioner system.
基金Supported by the Innovation Research Project of the Eye Hospital of Wenzhou Medical University (No. YNCX201308)
文摘AIM: To report the results of rhegmatogenous retinal detachment(RRD) repair after pars plana vitrectomy(PPV) without operative use of heavy liquid, and utilizing air tamponade in selected cases.METHODS: RRD patients without severity of proliferative vitreoretinopathy C2 or more underwent PPV without operative use of heavy liquid, and utilizing air tamponade were consecutively enrolled. Alternative postoperative facedown position or lateral position was required for 3-5 d.RESULTS: Totally 36 eyes of 36 patients(24 males, 66.7%) aged 53.8±10.9 y underwent this modified surgery. The mean number of retinal break was 2.1±1.3. Most of the eyes(29, 80.6%) had retinal detachment involving more than one quadrant. Twenty-two(61.1%) eyes with cataract had combined phacoemulsification and intraocular lens implantation. The mean follow up time was 4.6±1.8 mo. Two eyes with retinal redetachment underwent a second retinal repair surgery with silicone oil tamponade, yielding the primary reattachment rate to 94.4%(34/36). Six(16.7%) eyes had intraocular pressure higher than 25 mm Hg. The visual acuity(logMAR) improved from 0.98±0.74 preoperatively to 0.52±0.31 postoperatively(P〈0.001). CONCLUSION: The success rate of this modified retinal repair surgery is comparable with traditional surgery. This technique can be considered for certain retinal detachment patients, since its apparent advantages included lower surgical complications, reduced surgery expenditure, shorter time for postoperative facedown position, and avoiding silicone oil removal surgery.
文摘Insulation is one of the most important parts in a high voltage equipment.There are gaseous,liquid and solid insulations which are commonly used.In a high voltage transformer for example the insulating materials are all used.During operation of a high voltage equipment high electric stress may occur.Under extreme condition failure of the insulation may take place.Excessive electric field in air may cause corona discharges while in liquid insulation discharges may take place in the form of streamer.This paper reports experimental results on the corona and streamer discharges in air and silicone oil.The discharges were artificially generated around a needle tip in a needle-plane electrode system with gap length of 4 mm under sinusoidal and triangular voltages.The needle was made of steel with tip radius of 3 μm and curvature angle of 30°.The needle was made by Ogura Jewelry.The discharge pulses were measured using personal-computer based partial discharge(PD)measurement system with sensitivity of better than 0.5 pC.The system is able to measure discharge in time sequential.Phase-resolved analysis of the discharges was done to interpret the physical processes behind the discharges.The experimental results showed that corona discharges took place at negative half cycles.The discharges were concentrated around 270° of phase angle of applied voltage.The discharge magnitude and discharge number of corona clearly dependent on the instantaneous of applied voltage.These were strongly supported by the application of triangular voltage.Streamer discharges occurred at both positive and negative half cycles.The discharges pulses concentrated around the peak of applied voltage at phase angle of 90° and 270°.Experimental results under sinusoidal and triangular voltages revealed that streamer discharge magnitude as well as probability of occurrence was strongly dependent on the instantaneous applied voltage.
文摘Triheptyl cellulose/ethyl cellulose(3/97)binary blend membranes were prepared from tetrahydrofuran,chloroform and dichloromethane solutions and their air separation capabit- ities were studied at different temperatures.With increasing temperature from 25 to 85℃,the flux QOEA of O_2-enriched air(OEA),O_2 permselectivity and the O_2 concentration Yo_2 in the OEA all increase.The membranes show a unique trend in their Yo_2~QOEA relationship,that is,the air separation capability increases simultaneously with the OEA permeation capability.The magnitudes of QOEA and Yo_2 for 17μm-thick membrane after the testg time of 36hours at 70℃ are 5×10^(-4)cm^3 (STP)/s·cm^2 and 37.6%,respectively.The air separation capability depends slightly on membrane forming solvents.
基金Supported by Liaoning Provincial Natural Science Foundation(No.972050).
文摘A multi-tube air-lift loop reactor (MT-ALR) is presented in this paper. Based on the energy conservation, a mathematical model describing the liquid circulation flow rate was developed, which was determined by gas velocity, the cross areas of riser and downcomer, gas hold-up and the local frictional loss coefficient. The experimental data indicate that either increase of gas flow rate or reduction of the downcomer diameter contributes to higher liquid circulation rate. The correlation between total and the local frictional loss coefficients was also established.Effects of gas flowrate in two risers and diameter of downcomer on the liquid circulation rate were examined. The value of total frictional loss coefficient was measured as a function of the cross area of downcomer and independent of the gas flow rate. The calculated results of liquid circulation rates agreed well with the experimental data with an average relative error of 9.6%.
基金Supported by the National Natural Science Foundation of China(Grant No.59995460)
文摘The liquid phase turbulent structure of an air-water bubbly horizontal flow in a circular pipe has been investigated experimentally. Three-dimensional measurements were implemented with two "X" type probes oriented in different planes, and local liquid-phase velocities and turbulent stresses were simultaneously obtained. Systematic measurements were conducted covering a range of local void fraction from 0 to 11.7%. The important experiment results and parametric trends are summarized and discussed.
文摘浮式液化天然气生产储卸装置(floating liquefied natural gas system,FLNG)特种液货船作为开发海上天然气田的新式装置,极大的方便了对处于深海的气田的开发利用,该文以“Prelude”号FLNG作为母船,提出一种新型FLNG低温能量管理系统。该系统主要利用液态空气作为媒介储存和释放能量,通过液态空气冷能与混合制冷循环相结合实现天然气液化过程,在提高LNG生产性能的同时集成了CO_(2)液化循环和电力的生产,通过CO_(2)液化和剩余冷能发电提高系统的输出性能,实现了FLNG船舶冷能的多级利用,也为FLNG船舶冷能利用提供新方法,新途径。所提系统相较于基准模型具有更好的性能,在7.04年可实现成本回收。最后采用多目标性能优化,进一步提高系统㶲效率达60.67%,同时降低约2.3%的成本。该FLNG低温能量管理系统有高效、低耗、稳收益、低碳化等特点,可更好优化海上LNG供应链,促进航运业“双碳”发展。