Numerical and experimental investigation results on the magnetohydrodynamics(MHD) film flows along flat and curved bottom surfaces are summarized in this study. A simplified modeling has been developed to study the ...Numerical and experimental investigation results on the magnetohydrodynamics(MHD) film flows along flat and curved bottom surfaces are summarized in this study. A simplified modeling has been developed to study the liquid metal MHD film state, which has been validated by the existing experimental results. Numerical results on how the inlet velocity(V), the chute width(W) and the inlet film thickness(d0) affect the MHD film flow state are obtained. MHD stability analysis results are also provided in this study. The results show that strong magnetic fields make the stable V decrease several times compared to the case with no magnetic field,especially small radial magnetic fields(Bn) will have a significant impact on the MHD film flow state. Based on the above numerical and MHD stability analysis results flow control methods are proposed for flat and curved MHD film flows. For curved film flow we firstly proposed a new multi-layers MHD film flow system with a solid metal mesh to get the stable MHD film flows along the curved bottom surface. Experiments on flat and curved MHD film flows are also carried out and some firstly observed results are achieved.展开更多
In order to eliminate mal-distribution and ensure the side arm to produce desirable gas quality a special distributor is proposed. The experimental distributor mainly consists of a straight through section,a gas extra...In order to eliminate mal-distribution and ensure the side arm to produce desirable gas quality a special distributor is proposed. The experimental distributor mainly consists of a straight through section,a gas extraction line,a liquid extraction line and a side arm branch. A gas orifice and a liquid orifice are mounted at the gas and liquid extraction line respectively to control the outlet gas quality. The diameter of the liquid orifice was set to 2. 50 mm and three gas orifices with different size( dG= 2. 65,5. 00,10. 00 mm) were tested. The experiments were carried out at an air-water two-phase flow loop. The gas superficial velocity ranged from 6. 0 to 20. 0 m /s and the liquid superficial velocity was in the range of 0. 02- 0. 18 m /s. Flow patterns such as wave flow,slug flow and annular flow were observed. The gas quality of the side arm branch was found mainly determined by the flow area ratio of the gas orifice to the liquid orifice and independent of gas and liquid superficial velocity,flow patterns and extraction flux.展开更多
In this paper, a parallel fuzzy proportional plus fuzzy integral plus fuzzy derivative (FP+FI+FD) controller is proposed. It is derived from the conventional parallel proportional-integral-derivative (PID) contr...In this paper, a parallel fuzzy proportional plus fuzzy integral plus fuzzy derivative (FP+FI+FD) controller is proposed. It is derived from the conventional parallel proportional-integral-derivative (PID) controller. It preserves the linear structure of a conventional parallel PID controller, with analytical formulas. The final shape of the controller is a discrete-time fuzzy version of a conventional parallel PID controller. Computer simulations are performed to evaluate the performance of the FP+FI+FD controller for setpoint tracking and load-disturbance rejection for some complex processes, such as first- and second-order processes with delay, inverse response process with and without delay and higher order processes. Also, the performance of the proposed fuzzy controller is evaluated experimentally on highly nonlinear liquid-flow process with a hysteresis characteristic due to a pneumatic control valve. The simulation and real time control is done using National InstrumentTM hardware and software (LabVIEWTM). The response of the FP+FI+FD controller is compared with the conventional parallel PID controller, tuned with the Ziegler-Nichols (Z-H) and /~strSm- H^gglund (A-H) tuning technique. It is observed that the FP+FI+FD controller performed much better than the conventional PI/PID controller. Simulation and experimental results demonstrate the effectiveness of the proposed parallel FP+FI+FD controller.展开更多
This paper reports an experimental study on a liquid injector assembly integrated with an ultra-high frequency pulsed air jet that operates at 21 kHz. The active air-blasting assembly steadily injects a liquid through...This paper reports an experimental study on a liquid injector assembly integrated with an ultra-high frequency pulsed air jet that operates at 21 kHz. The active air-blasting assembly steadily injects a liquid through four micro-nozzles of 0.4 mm diameters each, positioned around a 1 mm nozzle through which the pulsed actuation jet flows out at supersonic velocity. High-frequency compressible air vortexes and shock waves generated by the injector atomize the liquid stream into finer droplets and distribute them to a larger area to improve mixing with the ambiance. The paper presents the design details and preliminary studies on the flow field characteristics of this novel injection scheme, which is a potential candidate for high-speed flow mixing and control applications.展开更多
基金supported by the National Magnetic Confinement Fusion Science Program of China(Nos.2014GB125003 and 2013GB114002)National Natural Science Foundation of China(No.11105044)
文摘Numerical and experimental investigation results on the magnetohydrodynamics(MHD) film flows along flat and curved bottom surfaces are summarized in this study. A simplified modeling has been developed to study the liquid metal MHD film state, which has been validated by the existing experimental results. Numerical results on how the inlet velocity(V), the chute width(W) and the inlet film thickness(d0) affect the MHD film flow state are obtained. MHD stability analysis results are also provided in this study. The results show that strong magnetic fields make the stable V decrease several times compared to the case with no magnetic field,especially small radial magnetic fields(Bn) will have a significant impact on the MHD film flow state. Based on the above numerical and MHD stability analysis results flow control methods are proposed for flat and curved MHD film flows. For curved film flow we firstly proposed a new multi-layers MHD film flow system with a solid metal mesh to get the stable MHD film flows along the curved bottom surface. Experiments on flat and curved MHD film flows are also carried out and some firstly observed results are achieved.
基金Sponsored by the National Natural Science Foundation of China (Grant No.51006123)the Fundamental Research Funds for the Central Universities (Grant No.14CX05028A)
文摘In order to eliminate mal-distribution and ensure the side arm to produce desirable gas quality a special distributor is proposed. The experimental distributor mainly consists of a straight through section,a gas extraction line,a liquid extraction line and a side arm branch. A gas orifice and a liquid orifice are mounted at the gas and liquid extraction line respectively to control the outlet gas quality. The diameter of the liquid orifice was set to 2. 50 mm and three gas orifices with different size( dG= 2. 65,5. 00,10. 00 mm) were tested. The experiments were carried out at an air-water two-phase flow loop. The gas superficial velocity ranged from 6. 0 to 20. 0 m /s and the liquid superficial velocity was in the range of 0. 02- 0. 18 m /s. Flow patterns such as wave flow,slug flow and annular flow were observed. The gas quality of the side arm branch was found mainly determined by the flow area ratio of the gas orifice to the liquid orifice and independent of gas and liquid superficial velocity,flow patterns and extraction flux.
文摘In this paper, a parallel fuzzy proportional plus fuzzy integral plus fuzzy derivative (FP+FI+FD) controller is proposed. It is derived from the conventional parallel proportional-integral-derivative (PID) controller. It preserves the linear structure of a conventional parallel PID controller, with analytical formulas. The final shape of the controller is a discrete-time fuzzy version of a conventional parallel PID controller. Computer simulations are performed to evaluate the performance of the FP+FI+FD controller for setpoint tracking and load-disturbance rejection for some complex processes, such as first- and second-order processes with delay, inverse response process with and without delay and higher order processes. Also, the performance of the proposed fuzzy controller is evaluated experimentally on highly nonlinear liquid-flow process with a hysteresis characteristic due to a pneumatic control valve. The simulation and real time control is done using National InstrumentTM hardware and software (LabVIEWTM). The response of the FP+FI+FD controller is compared with the conventional parallel PID controller, tuned with the Ziegler-Nichols (Z-H) and /~strSm- H^gglund (A-H) tuning technique. It is observed that the FP+FI+FD controller performed much better than the conventional PI/PID controller. Simulation and experimental results demonstrate the effectiveness of the proposed parallel FP+FI+FD controller.
文摘This paper reports an experimental study on a liquid injector assembly integrated with an ultra-high frequency pulsed air jet that operates at 21 kHz. The active air-blasting assembly steadily injects a liquid through four micro-nozzles of 0.4 mm diameters each, positioned around a 1 mm nozzle through which the pulsed actuation jet flows out at supersonic velocity. High-frequency compressible air vortexes and shock waves generated by the injector atomize the liquid stream into finer droplets and distribute them to a larger area to improve mixing with the ambiance. The paper presents the design details and preliminary studies on the flow field characteristics of this novel injection scheme, which is a potential candidate for high-speed flow mixing and control applications.