The emulsion liquid membrane technique was used to extract amino-J acid from industrial dye waste-water.The effects of stirring speed,ratio of the emulsion to water(Rew),ratio of the oil to internal phase(Roi)and memb...The emulsion liquid membrane technique was used to extract amino-J acid from industrial dye waste-water.The effects of stirring speed,ratio of the emulsion to water(Rew),ratio of the oil to internal phase(Roi)and membrane phase components on the extraction rate were investigated and optimized.The results showed that the extraction rate of amino-J acid approached 97% when the stirring speed was 300 r/min,Rew 1:6,Roi 1:1,trioctylamine(TOA)3 mL/100 mL kerosene,and methyl?didecyle?alcohol?acrylate(LMA-2)3 g/100 mL kerosene,respectively.The extraction rate had not changed with the oil phase reused for times.展开更多
The amino acids post-modified ionic liquids-based hybrid monolithic columns were successfully developed.For the first step,using 1-vinyl-3-dodecylimidazole bromide(VDI·Br)and polyhedral oligomeric silsesquioxane ...The amino acids post-modified ionic liquids-based hybrid monolithic columns were successfully developed.For the first step,using 1-vinyl-3-dodecylimidazole bromide(VDI·Br)and polyhedral oligomeric silsesquioxane methacryl substituted(POSS-MA)as monomer and crosslinking agent,the monolithic POSS-VDI matrix material was polymerized in 100μm capillary.The prepared POSS-VDI column is of ion-exchange/reverse-phase mixed-mode retention characteristics.The column e fficiency reached 137,000 N/m for thioureas.The POSS-VDI column has also been successfully applied to recognize and analyze the eff ective components of Traditional Chinese Medicines Fangji and the Root of Kudzu Vine.Furthermore,based on its good chromatographic performances,in the second step,amino acids L-Proline(L-Pro),Glycine(Gly)or DLPhenylalanine(DL-Phe)were further exploited as the anion exchangers to post-modify the POSS-VDI column.The new POSS-VDI-Pro,POSS-VDI-Gly and POSS-VDI-Phe columns exhibited diff erent separation selectivity for the complex egg white protein sample.The present work provides a good route to fabricate versatile amino acids and ionic liquids modified monolithic columns with good separation selectivity.展开更多
文摘The emulsion liquid membrane technique was used to extract amino-J acid from industrial dye waste-water.The effects of stirring speed,ratio of the emulsion to water(Rew),ratio of the oil to internal phase(Roi)and membrane phase components on the extraction rate were investigated and optimized.The results showed that the extraction rate of amino-J acid approached 97% when the stirring speed was 300 r/min,Rew 1:6,Roi 1:1,trioctylamine(TOA)3 mL/100 mL kerosene,and methyl?didecyle?alcohol?acrylate(LMA-2)3 g/100 mL kerosene,respectively.The extraction rate had not changed with the oil phase reused for times.
基金financial support from Hundred Outstanding Innovative Talents in Universities of Hebei Province(SLRC2019016)Natural Science Foundation of Hebei Province(B2019201327)+2 种基金Young Talent of Hebei ProvinceNational Natural Science Foundation of China(21675039)Scientific Research Project of Hebei Provincial Administration of Traditional Chinese Medicine(2015116)。
文摘The amino acids post-modified ionic liquids-based hybrid monolithic columns were successfully developed.For the first step,using 1-vinyl-3-dodecylimidazole bromide(VDI·Br)and polyhedral oligomeric silsesquioxane methacryl substituted(POSS-MA)as monomer and crosslinking agent,the monolithic POSS-VDI matrix material was polymerized in 100μm capillary.The prepared POSS-VDI column is of ion-exchange/reverse-phase mixed-mode retention characteristics.The column e fficiency reached 137,000 N/m for thioureas.The POSS-VDI column has also been successfully applied to recognize and analyze the eff ective components of Traditional Chinese Medicines Fangji and the Root of Kudzu Vine.Furthermore,based on its good chromatographic performances,in the second step,amino acids L-Proline(L-Pro),Glycine(Gly)or DLPhenylalanine(DL-Phe)were further exploited as the anion exchangers to post-modify the POSS-VDI column.The new POSS-VDI-Pro,POSS-VDI-Gly and POSS-VDI-Phe columns exhibited diff erent separation selectivity for the complex egg white protein sample.The present work provides a good route to fabricate versatile amino acids and ionic liquids modified monolithic columns with good separation selectivity.