期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
A Hydrogel's Formation Device for Quick Analysis of Liquid Samples Using Laser-Induced Breakdown Spectroscopy 被引量:1
1
作者 郭广盟 王杰 +2 位作者 边访 田地 樊庆文 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第6期661-665,共5页
The laser-induced breakdown spectroscopy technique has irreplaceable advantages in the field of detection due to its multi-phase specimen detection ability.The development of the LIBS technique for liquid analysis is ... The laser-induced breakdown spectroscopy technique has irreplaceable advantages in the field of detection due to its multi-phase specimen detection ability.The development of the LIBS technique for liquid analysis is obstructed by its inherent drawbacks like the surface ripples and extinction of emitted intensity,which make it unpractical.In this work,an in-situ hydrogel formation sampling device was designed and used the hydrogel as the detection phase of LIBS for Cu,Cr and Al in an aqueous solution.With the measured amount of resin placed in the device,the formed hydrogel could be obtained within 20 s after putting the device into water solution.The formed hydrogel could be directly analyzed by LIBS and reflect the elemental information of the water sample.The prominent performance made this hydrogel's formation device especially suitable for quick in-situ environmental liquid analysis using LIBS. 展开更多
关键词 laser-induced breakdown spectroscopy quick analysis liquid samples hydrogel formation
下载PDF
A Perspective of Laser Sampling for Inductively Coupled Plasma-Atomic Emission Spectro metry for Rock and Mineral Analysis
2
作者 Lin Shoulin Peng ZhaofengChina University of Geosciences , Wuhan 430074 《Journal of Earth Science》 SCIE CAS CSCD 1992年第1期120-128,共9页
The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser samp... The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser sampling of liquid samples for inductively coupled plasma -atomic emission spectrometry has been proposed , and its analytical performance investigated.Experimental results showed that,as a method of sample introduction , laser vaporization of liquid samples enjoyed certain advantages , e.g.,much higher sensitivity, much lower detection limit and reduced sample volume , over solution nebulization . A perspective of the application of laser sampling-inductively coupled plasma - actomic emission spectrometry for rock and mineral analysis is estimated as well. 展开更多
关键词 continuous laser sampling complete laser vaporization of samples inductively coupled plasma-atomic emission spectrometry solid sample liquid sample rock and mineral analysis .
下载PDF
Analysis of trace dicyandiamide in stream water using solid phase extraction and liquid chromatography UV spectrometry 被引量:2
3
作者 Huidong Qiu Dongdi Sun +2 位作者 Sameera R.Gunatilake Jinyan She Todd E.Mlsna 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2015年第9期38-42,共5页
An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction.The extraction procedure(including loading,... An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction.The extraction procedure(including loading, washing, and eluting) used a flow rate of1.0 m L/min, and dicyandiamide was eluted with 20 m L of a methanol/acetonitrile mixture(V/V = 2:3), followed by pre-concentration using nitrogen evaporation and analysis with high performance liquid chromatography–ultraviolet spectroscopy(HPLC–UV). Sample extraction was carried out using a Waters Sep-Pak AC-2 Cartridge(with activated carbon).Separation was achieved on a ZIC-Hydrophilic Interaction Liquid Chromatography(ZIC-HILIC)(50 mm × 2.1 mm, 3.5 μm) chromatography column and quantification was accomplished based on UV absorbance. A reliable linear relationship was obtained for the calibration curve using standard solutions(R^2〉 0.999). Recoveries for dicyandiamide ranged from 84.6% to 96.8%, and the relative standard deviations(RSDs, n = 3) were below 6.1% with a detection limit of 5.0 ng/m L for stream water samples. 展开更多
关键词 Dicyandiamide Solid phase extraction Stream water samples High performance liquid chromatography–ultraviolet spectrometry
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部