diketone type chelating ligands have high coordinative activity and selectivity, and are widely applied in analytical chemistry. In order to obtain profounder understanding to the properties of bis(4 acylpyrazolone ...diketone type chelating ligands have high coordinative activity and selectivity, and are widely applied in analytical chemistry. In order to obtain profounder understanding to the properties of bis(4 acylpyrazolone 5), A new 4 acylpyrazol 5 one derivative (H 2BPMPP) was syntheszed, which contains a heterocyclic ring between two 1 phenyl 3 methyl 4 acylpyrazol 5 one rings. The new compound was characterized by element analyses, UV, IR and 1H NMR spectra. The equilibrium of the keto enol tautomerism was studied. The results show that a lower dielectric constant of solvent favors the enol form which has a higher λ max . Due to special merits of paraffin wax, the solid liquid extraction behavior of Ce(Ⅲ) with molten paraffin wax as a diluent was also investigated at higher temperature. The value of the pH 1/2 was 3.19 and the value of log K ex was 3.467. The chemical composition of the complex was obtained by the slope analysis method.展开更多
To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry ...To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%.展开更多
A reliable,selective and sensitive liquid chromatography tandem mass spectrometry method was developed and validated for the quantification of lamotrigine in human plasma using lamotrigine13C3,d3 as an internal standa...A reliable,selective and sensitive liquid chromatography tandem mass spectrometry method was developed and validated for the quantification of lamotrigine in human plasma using lamotrigine13C3,d3 as an internal standard.Analyte and internal standard were extracted from human plasma by solid-phase extraction and detected in positive ion mode by tandem mass spectrometry with electrospray ionization(ESI) interface.Chromatographic separation was performed on a Chromolith s SpeedROD;RP-18e column(50-4.6 mm i.d.) using acetonitrile:570.1 mM ammonium formate solution(90:10,v/v) as the mobile phase at a flow rate of 0.500 mL/min.The calibration curves were linear over the range of 5.02-1226.47 ng/mL with the lower limit of quantitation validated at 5.02 ng/mL.The analytes were found stable in human plasma through three freeze(-20℃)-thaw(ice-cold water bath) cycles and under storage on bench-top in ice-cold water bath for at least 6.8 h,and also in the mobile phase at 10℃ for at least 57h.The method has shown good reproducibility,as the intra-and inter-day precisions were within 3.0%,while the accuracies were within 76.0% of nominal values.The validated LC-MS/MS method was applied for the evaluation of pharmacokinetic and bioequivalence parameters of lamotrigine after an oral administration of 50mg lamotrigine tablet to thirty-two healthy adult male volunteers.展开更多
An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction.The extraction procedure(including loading,...An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction.The extraction procedure(including loading, washing, and eluting) used a flow rate of1.0 m L/min, and dicyandiamide was eluted with 20 m L of a methanol/acetonitrile mixture(V/V = 2:3), followed by pre-concentration using nitrogen evaporation and analysis with high performance liquid chromatography–ultraviolet spectroscopy(HPLC–UV). Sample extraction was carried out using a Waters Sep-Pak AC-2 Cartridge(with activated carbon).Separation was achieved on a ZIC-Hydrophilic Interaction Liquid Chromatography(ZIC-HILIC)(50 mm × 2.1 mm, 3.5 μm) chromatography column and quantification was accomplished based on UV absorbance. A reliable linear relationship was obtained for the calibration curve using standard solutions(R^2〉 0.999). Recoveries for dicyandiamide ranged from 84.6% to 96.8%, and the relative standard deviations(RSDs, n = 3) were below 6.1% with a detection limit of 5.0 ng/m L for stream water samples.展开更多
文摘diketone type chelating ligands have high coordinative activity and selectivity, and are widely applied in analytical chemistry. In order to obtain profounder understanding to the properties of bis(4 acylpyrazolone 5), A new 4 acylpyrazol 5 one derivative (H 2BPMPP) was syntheszed, which contains a heterocyclic ring between two 1 phenyl 3 methyl 4 acylpyrazol 5 one rings. The new compound was characterized by element analyses, UV, IR and 1H NMR spectra. The equilibrium of the keto enol tautomerism was studied. The results show that a lower dielectric constant of solvent favors the enol form which has a higher λ max . Due to special merits of paraffin wax, the solid liquid extraction behavior of Ce(Ⅲ) with molten paraffin wax as a diluent was also investigated at higher temperature. The value of the pH 1/2 was 3.19 and the value of log K ex was 3.467. The chemical composition of the complex was obtained by the slope analysis method.
基金supported by the Preventive medicine and public health research project of Anhui,China(No.2011Y0103)the Natural Science Foundation of Anhui,China(No.11040606M216)
文摘To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%.
文摘A reliable,selective and sensitive liquid chromatography tandem mass spectrometry method was developed and validated for the quantification of lamotrigine in human plasma using lamotrigine13C3,d3 as an internal standard.Analyte and internal standard were extracted from human plasma by solid-phase extraction and detected in positive ion mode by tandem mass spectrometry with electrospray ionization(ESI) interface.Chromatographic separation was performed on a Chromolith s SpeedROD;RP-18e column(50-4.6 mm i.d.) using acetonitrile:570.1 mM ammonium formate solution(90:10,v/v) as the mobile phase at a flow rate of 0.500 mL/min.The calibration curves were linear over the range of 5.02-1226.47 ng/mL with the lower limit of quantitation validated at 5.02 ng/mL.The analytes were found stable in human plasma through three freeze(-20℃)-thaw(ice-cold water bath) cycles and under storage on bench-top in ice-cold water bath for at least 6.8 h,and also in the mobile phase at 10℃ for at least 57h.The method has shown good reproducibility,as the intra-and inter-day precisions were within 3.0%,while the accuracies were within 76.0% of nominal values.The validated LC-MS/MS method was applied for the evaluation of pharmacokinetic and bioequivalence parameters of lamotrigine after an oral administration of 50mg lamotrigine tablet to thirty-two healthy adult male volunteers.
基金Department of Chemistry at Mississippi State University for financial support for this project
文摘An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction.The extraction procedure(including loading, washing, and eluting) used a flow rate of1.0 m L/min, and dicyandiamide was eluted with 20 m L of a methanol/acetonitrile mixture(V/V = 2:3), followed by pre-concentration using nitrogen evaporation and analysis with high performance liquid chromatography–ultraviolet spectroscopy(HPLC–UV). Sample extraction was carried out using a Waters Sep-Pak AC-2 Cartridge(with activated carbon).Separation was achieved on a ZIC-Hydrophilic Interaction Liquid Chromatography(ZIC-HILIC)(50 mm × 2.1 mm, 3.5 μm) chromatography column and quantification was accomplished based on UV absorbance. A reliable linear relationship was obtained for the calibration curve using standard solutions(R^2〉 0.999). Recoveries for dicyandiamide ranged from 84.6% to 96.8%, and the relative standard deviations(RSDs, n = 3) were below 6.1% with a detection limit of 5.0 ng/m L for stream water samples.