A new method for the enrichment of Strychnos alkaloids in biological samples via liquid-phase microextxaodon (LPME) based on porous polypropylene hollow fibers in combination with on-line sweeping in micellar electr...A new method for the enrichment of Strychnos alkaloids in biological samples via liquid-phase microextxaodon (LPME) based on porous polypropylene hollow fibers in combination with on-line sweeping in micellar electrokinodc chromatography was developed. The calibration curve was linear over the range of 20-200 ng mL^-1 for both strychnine and brucine in human urine sample. The detection limits (S/N = 3:1) for strychnine and brucine were 1 ng mL^-1 and 2 ng mL^-1, respectively. The LPME-sweeping method has been successfully applied to the analysis of strychnine and brucine in real urine samples.展开更多
The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamox...The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamoxifen (TAM) in biological fluids including human urine and plasma. The drug was extracted from a 15 mL aqueous sample (source phase;SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase;MP) followed by the back-extraction into a second aqueous solution (receiving phase;RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency were examined and optimized. An enrichment factor of 360 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1 - 500 ng?mL–1 and the limit of detection was found to be 0.5 ng?mL–1 in aqueous medium. A reasonable relative recovery (≥89%) and satisfactory intra-assay (3.7% - 4.2%, n = 3) and inter-assay (7.5% - 7.8%, n = 3) precision illustrated good performance of the analytical procedure in spiked human urine and plasma samples.展开更多
A method termed hollow fiber liquid phase microextraction (HF-LPME) was utilized to extract three chlo- rophenols, 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP) and 2,4,6- trichlorophenol (2,4,6-TCP), separately...A method termed hollow fiber liquid phase microextraction (HF-LPME) was utilized to extract three chlo- rophenols, 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP) and 2,4,6- trichlorophenol (2,4,6-TCP), separately from water. The extracted chlorophenols were then separated, identified, and quantified by UV-Vis spectrophotometry with photodiode array detection (UV-Vis/DAD). In the study, experimental con-ditions such as organic phase identity, acceptor phase volume, sample agitation, extraction time, acceptor phase NaOH concentration, donor phase HCl concentration, salt addition, and UV absorption wavelength were optimized. The statistical parameters of the proposed method were investigated under the selected con-ditions. The analytical characteristics of the method such as detection limit, accuracy, precision, relative standard deviation (R.S.D.) and relative standard error (R.S.E.) was calculated. The results showed that the proposed method is simple, rapid, accurate and precise for the analysis of ternary mixtures.展开更多
A simple method based on hollow fiber liquid-phase microextraction (HF-LPME) followed by high performance liquid chro-matography (HPLC) analysis was successfully developed for the determination of UV filters in cosmet...A simple method based on hollow fiber liquid-phase microextraction (HF-LPME) followed by high performance liquid chro-matography (HPLC) analysis was successfully developed for the determination of UV filters in cosmetic products. A canular extractor was assembled by mounting a hollow fiber inside an external tube with a tee-connector. The organic solvent was immobilized into the fiber to form a liquid membrane as the acceptor phase. The sample was continuously injected into the extractor and the UV filters were extracted from the aqueous sample into organic acceptor phase. The main parameters affecting HF-LPME including extraction solvent, sample volume, sample flow rate, pH values and ionic strength were investigated. Toluene has been verified to be suitable as the acceptor phase. Under the optimized HF-LPME conditions, the enrichment factors of five UV filters varying from 24 to 57 were achieved. The limits of detection for the five UV filters were in the range of 1-100 μg L-1 .The relative standard deviations (RSDs) of HF-LPME and HPLC analysis were lower than 5.2%. The proposed method has been successfully applied to the analysis of the varied cosmetic products.展开更多
A temperature-controlled ionic liquid dispersive liquid-phase microextraction in combination with high performance liquid chromatography was developed for the enrichment and determination of triazine herbicides such a...A temperature-controlled ionic liquid dispersive liquid-phase microextraction in combination with high performance liquid chromatography was developed for the enrichment and determination of triazine herbicides such as cyanazine,simazine,and atrazine in water samples.1-Octyl-3-methylimidazolium hexafluorophosphate([C8MIM][PF6]) was selected as the extraction solvent.Several experimental parameters were optimized.Under the optimal conditions,the linear range for cyanazine was in the concentration range of 0.5–80 mg/L and the linear range for simazine and atrazine was in the range of1.0–100 mg/L.The limit of detection(LOD,S/N = 3) was in the ranges of 0.05–0.06 mg/L,and the intra day and inter day precision(RSDs,n = 6) was in the ranges of 3.2%–6.6% and 4.8%–8.9%,respectively.Four real water samples were analyzed with the developed method,and the experimental results showed that the spiked recoveries were satisfactory.All these exhibited that the developed method was a valuable tool for monitoring such pollutants.展开更多
建立了顶空液相微萃取/气相色谱-质谱联用测定中药枳壳中有机挥发物的方法。在顶空液相微萃取实验条件优化的基础上,确定了最佳实验条件:以正辛烷作为有机萃取剂,体积为2μL,样品用量为0.3g,液滴距离样品表面0.8 cm处,萃取8 m in后直接...建立了顶空液相微萃取/气相色谱-质谱联用测定中药枳壳中有机挥发物的方法。在顶空液相微萃取实验条件优化的基础上,确定了最佳实验条件:以正辛烷作为有机萃取剂,体积为2μL,样品用量为0.3g,液滴距离样品表面0.8 cm处,萃取8 m in后直接进样。与固相微萃取/气相色谱-质谱法相比,顶空液相微萃取法定性了30种成分,固相微萃取法定性了24种成分,顶空液相微萃取法操作简单、快速,实验结果灵敏度更高,且萃取效率高,重复性好,可用于中药枳壳中有机挥发物的快速分析。展开更多
基金This work was supported both by the Natural Science Foundation of Hebei Province(B2006000413)the Scientific Research Foundation for the Returned 0verseas Chinese Scholars,State Education Ministry.
文摘A new method for the enrichment of Strychnos alkaloids in biological samples via liquid-phase microextxaodon (LPME) based on porous polypropylene hollow fibers in combination with on-line sweeping in micellar electrokinodc chromatography was developed. The calibration curve was linear over the range of 20-200 ng mL^-1 for both strychnine and brucine in human urine sample. The detection limits (S/N = 3:1) for strychnine and brucine were 1 ng mL^-1 and 2 ng mL^-1, respectively. The LPME-sweeping method has been successfully applied to the analysis of strychnine and brucine in real urine samples.
文摘The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamoxifen (TAM) in biological fluids including human urine and plasma. The drug was extracted from a 15 mL aqueous sample (source phase;SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase;MP) followed by the back-extraction into a second aqueous solution (receiving phase;RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency were examined and optimized. An enrichment factor of 360 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1 - 500 ng?mL–1 and the limit of detection was found to be 0.5 ng?mL–1 in aqueous medium. A reasonable relative recovery (≥89%) and satisfactory intra-assay (3.7% - 4.2%, n = 3) and inter-assay (7.5% - 7.8%, n = 3) precision illustrated good performance of the analytical procedure in spiked human urine and plasma samples.
文摘A method termed hollow fiber liquid phase microextraction (HF-LPME) was utilized to extract three chlo- rophenols, 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP) and 2,4,6- trichlorophenol (2,4,6-TCP), separately from water. The extracted chlorophenols were then separated, identified, and quantified by UV-Vis spectrophotometry with photodiode array detection (UV-Vis/DAD). In the study, experimental con-ditions such as organic phase identity, acceptor phase volume, sample agitation, extraction time, acceptor phase NaOH concentration, donor phase HCl concentration, salt addition, and UV absorption wavelength were optimized. The statistical parameters of the proposed method were investigated under the selected con-ditions. The analytical characteristics of the method such as detection limit, accuracy, precision, relative standard deviation (R.S.D.) and relative standard error (R.S.E.) was calculated. The results showed that the proposed method is simple, rapid, accurate and precise for the analysis of ternary mixtures.
基金supported by the National Natural Science Foundation of China (90813015 & 20935002)
文摘A simple method based on hollow fiber liquid-phase microextraction (HF-LPME) followed by high performance liquid chro-matography (HPLC) analysis was successfully developed for the determination of UV filters in cosmetic products. A canular extractor was assembled by mounting a hollow fiber inside an external tube with a tee-connector. The organic solvent was immobilized into the fiber to form a liquid membrane as the acceptor phase. The sample was continuously injected into the extractor and the UV filters were extracted from the aqueous sample into organic acceptor phase. The main parameters affecting HF-LPME including extraction solvent, sample volume, sample flow rate, pH values and ionic strength were investigated. Toluene has been verified to be suitable as the acceptor phase. Under the optimized HF-LPME conditions, the enrichment factors of five UV filters varying from 24 to 57 were achieved. The limits of detection for the five UV filters were in the range of 1-100 μg L-1 .The relative standard deviations (RSDs) of HF-LPME and HPLC analysis were lower than 5.2%. The proposed method has been successfully applied to the analysis of the varied cosmetic products.
基金financially supported by the National Natural Science Foundation of China (No. 21377167)Program for New Century Excellent Talents in University (No. NCET-10-0813)
文摘A temperature-controlled ionic liquid dispersive liquid-phase microextraction in combination with high performance liquid chromatography was developed for the enrichment and determination of triazine herbicides such as cyanazine,simazine,and atrazine in water samples.1-Octyl-3-methylimidazolium hexafluorophosphate([C8MIM][PF6]) was selected as the extraction solvent.Several experimental parameters were optimized.Under the optimal conditions,the linear range for cyanazine was in the concentration range of 0.5–80 mg/L and the linear range for simazine and atrazine was in the range of1.0–100 mg/L.The limit of detection(LOD,S/N = 3) was in the ranges of 0.05–0.06 mg/L,and the intra day and inter day precision(RSDs,n = 6) was in the ranges of 3.2%–6.6% and 4.8%–8.9%,respectively.Four real water samples were analyzed with the developed method,and the experimental results showed that the spiked recoveries were satisfactory.All these exhibited that the developed method was a valuable tool for monitoring such pollutants.
文摘建立了顶空液相微萃取/气相色谱-质谱联用测定中药枳壳中有机挥发物的方法。在顶空液相微萃取实验条件优化的基础上,确定了最佳实验条件:以正辛烷作为有机萃取剂,体积为2μL,样品用量为0.3g,液滴距离样品表面0.8 cm处,萃取8 m in后直接进样。与固相微萃取/气相色谱-质谱法相比,顶空液相微萃取法定性了30种成分,固相微萃取法定性了24种成分,顶空液相微萃取法操作简单、快速,实验结果灵敏度更高,且萃取效率高,重复性好,可用于中药枳壳中有机挥发物的快速分析。