The 10kV distribution network is an essential component of the power system,and its stable operation is crucial for ensuring reliable power supply.However,various factors can lead to faults in the distribution network...The 10kV distribution network is an essential component of the power system,and its stable operation is crucial for ensuring reliable power supply.However,various factors can lead to faults in the distribution network.In order to enhance the safety and reliability of power distribution,this paper focuses on the analysis of faults in the 10kV distribution network caused by natural factors,operational factors,human factors,and equipment factors.It elucidates the various hazards resulting from distribution network faults and proposes corresponding preventive measures for different types of faults in the 10kV distribution network.The aim is to mitigate or reduce the impact of distribution network faults,ensuring the safe and stable operation of the distribution system.展开更多
Considering the complexity of the geographical surroundings and the height of 10 kV distribution line, the impact of trees on the lightning performance can not be ignored. A model of lightning position judgment and ov...Considering the complexity of the geographical surroundings and the height of 10 kV distribution line, the impact of trees on the lightning performance can not be ignored. A model of lightning position judgment and overvoltage calculation based on the concept of striking distance is built. With the theory of orthogonal test, the main factors of trees' influence on lightning performance are figured out. The results indicate that the location of trees is the main factor. In practical engineering, suitable management of vegetation can improve the lightning performance and reduce the lightning failure of 10 kV distribution line.展开更多
为解决配电线路单相接地故障诊断准确率低的问题,引入行波信号开展了基于行波信号的10 k V配电线路单相接地故障诊断方法的研究。首先利用行波信号提取配电线路故障特征,然后设置配电线路两端行波记录点,通过测距定位确定故障位置实现...为解决配电线路单相接地故障诊断准确率低的问题,引入行波信号开展了基于行波信号的10 k V配电线路单相接地故障诊断方法的研究。首先利用行波信号提取配电线路故障特征,然后设置配电线路两端行波记录点,通过测距定位确定故障位置实现配电线路单相接地故障诊断。结果表明,应用该方法后,配电线路单相接地故障诊断识别准确率达到98.5%以上,可行性较高。展开更多
基金Tibet Autonomous Region Natural Fund Key Project(XZ202201ZR0024G)。
文摘The 10kV distribution network is an essential component of the power system,and its stable operation is crucial for ensuring reliable power supply.However,various factors can lead to faults in the distribution network.In order to enhance the safety and reliability of power distribution,this paper focuses on the analysis of faults in the 10kV distribution network caused by natural factors,operational factors,human factors,and equipment factors.It elucidates the various hazards resulting from distribution network faults and proposes corresponding preventive measures for different types of faults in the 10kV distribution network.The aim is to mitigate or reduce the impact of distribution network faults,ensuring the safe and stable operation of the distribution system.
文摘Considering the complexity of the geographical surroundings and the height of 10 kV distribution line, the impact of trees on the lightning performance can not be ignored. A model of lightning position judgment and overvoltage calculation based on the concept of striking distance is built. With the theory of orthogonal test, the main factors of trees' influence on lightning performance are figured out. The results indicate that the location of trees is the main factor. In practical engineering, suitable management of vegetation can improve the lightning performance and reduce the lightning failure of 10 kV distribution line.
文摘为解决配电线路单相接地故障诊断准确率低的问题,引入行波信号开展了基于行波信号的10 k V配电线路单相接地故障诊断方法的研究。首先利用行波信号提取配电线路故障特征,然后设置配电线路两端行波记录点,通过测距定位确定故障位置实现配电线路单相接地故障诊断。结果表明,应用该方法后,配电线路单相接地故障诊断识别准确率达到98.5%以上,可行性较高。