Most of the controllers of IM (induction motor) for industrial applications have been designed based on PI controller without consideration of CL (core loss) and SLL (stray load loss). To get the precise perform...Most of the controllers of IM (induction motor) for industrial applications have been designed based on PI controller without consideration of CL (core loss) and SLL (stray load loss). To get the precise performances of torque as well as rotor speed and flux, the above mentioned losses should be considered. Conventional PI controller has overshoot effect at the transient period of the speed response curve. On the other hand, fuzzy logic and ANN (artificial neural network) based controllers can minimize the overshoot effect at the transient period because they have the abilities to deal with the nonlinear systems. In this paper, a comparative analysis is done between PI, fuzzy logic and ANN based speed controllers to find the suitable control strategy for IM with consideration of CL and SLL. The simulation analysis is done by using Matlab/Simulink software. The simulation results show that the fuzzy logic based speed controller gives better responses than ANN and conventional PI based speed controllers in terms of rotor speed, electromagnetic torque and rotor flux of IM.展开更多
Continuous power supply of urban power networks(UPNs)is quite essential for the public security of a city because the UPN acts as the basis for other infrastructure networks.In recent years,UPN is threatened by extrem...Continuous power supply of urban power networks(UPNs)is quite essential for the public security of a city because the UPN acts as the basis for other infrastructure networks.In recent years,UPN is threatened by extreme weather events.An accurate modeling of load loss risk under extreme weather is quite essential for the preventive action of UPN.Con-sidering the forecast intensity of a typhoon disaster,this paper proposes analytical modeling of disaster-induced load loss for preventive allocation of mobile power sources(MPSs)in UPNs.First,based on the topological structure and fragility model of overhead lines and substations,we establish an analytical load loss model of multi-voltage-level UPN to quantify the spatial dis-tribution of disaster-induced load loss at the substation level.Second,according to the projected load loss distribution,a preventive allocation method of MPS is proposed,which makes the best use of MPS and dispatches the limited power supply to most vulnerable areas in the UPN.Finally,the proposed meth-od is validated by the case study of a practical UPN in China.展开更多
The research reported in this paper focuses on non-technical power loss reduction for power distribution systems. Such reduction of costs of energy not served (ENS.COST), is intelligently evaluated and optimized using...The research reported in this paper focuses on non-technical power loss reduction for power distribution systems. Such reduction of costs of energy not served (ENS.COST), is intelligently evaluated and optimized using a firefly algorithm, from where savings of 43.3% on energy not served are achieved.展开更多
Load flow studies play a critical role in the analysis of power systems. They enable the computation of voltage, current, and power flows in a power system. They provide valuable insights into the steady-state perform...Load flow studies play a critical role in the analysis of power systems. They enable the computation of voltage, current, and power flows in a power system. They provide valuable insights into the steady-state performance of the power system under different operating conditions. Choosing a slack bus is a vital step in conducting load flow simulations. A slack bus is a PV bus that includes a generator and is used to balance real and reactive power during load flow studies. Many studies have been conducted on the selection of slack buses in load flow analysis. However, varied conclusions regarding the impact on system losses and power flows were obtained during these studies. Therefore, using the IEEE-14 bus test system, this study investigated the effects of slack bus selection in strong and weak grids by alternating slack buses among PV buses and observing the effects on bus voltage magnitude, bus voltage phase angle, total power flows, and active and reactive power losses. The study noted that the effect of slack bus selection on these system quantities is contingent upon the voltage stability of the grid. Whereas in a robust grid, system losses and power flows remained constant irrespective of the choice of slack bus, a weak grid experienced some variations in these system quantities under similar circumstances. The simulation results led to the conclusion that, to a large extent, the voltage stability of the grid plays a significant role in determining the degree to which slack bus selection affects system losses and other quantities in load flow studies.展开更多
文摘Most of the controllers of IM (induction motor) for industrial applications have been designed based on PI controller without consideration of CL (core loss) and SLL (stray load loss). To get the precise performances of torque as well as rotor speed and flux, the above mentioned losses should be considered. Conventional PI controller has overshoot effect at the transient period of the speed response curve. On the other hand, fuzzy logic and ANN (artificial neural network) based controllers can minimize the overshoot effect at the transient period because they have the abilities to deal with the nonlinear systems. In this paper, a comparative analysis is done between PI, fuzzy logic and ANN based speed controllers to find the suitable control strategy for IM with consideration of CL and SLL. The simulation analysis is done by using Matlab/Simulink software. The simulation results show that the fuzzy logic based speed controller gives better responses than ANN and conventional PI based speed controllers in terms of rotor speed, electromagnetic torque and rotor flux of IM.
基金supported by National Natural Science Foundation of China(No.52307094).
文摘Continuous power supply of urban power networks(UPNs)is quite essential for the public security of a city because the UPN acts as the basis for other infrastructure networks.In recent years,UPN is threatened by extreme weather events.An accurate modeling of load loss risk under extreme weather is quite essential for the preventive action of UPN.Con-sidering the forecast intensity of a typhoon disaster,this paper proposes analytical modeling of disaster-induced load loss for preventive allocation of mobile power sources(MPSs)in UPNs.First,based on the topological structure and fragility model of overhead lines and substations,we establish an analytical load loss model of multi-voltage-level UPN to quantify the spatial dis-tribution of disaster-induced load loss at the substation level.Second,according to the projected load loss distribution,a preventive allocation method of MPS is proposed,which makes the best use of MPS and dispatches the limited power supply to most vulnerable areas in the UPN.Finally,the proposed meth-od is validated by the case study of a practical UPN in China.
文摘The research reported in this paper focuses on non-technical power loss reduction for power distribution systems. Such reduction of costs of energy not served (ENS.COST), is intelligently evaluated and optimized using a firefly algorithm, from where savings of 43.3% on energy not served are achieved.
文摘Load flow studies play a critical role in the analysis of power systems. They enable the computation of voltage, current, and power flows in a power system. They provide valuable insights into the steady-state performance of the power system under different operating conditions. Choosing a slack bus is a vital step in conducting load flow simulations. A slack bus is a PV bus that includes a generator and is used to balance real and reactive power during load flow studies. Many studies have been conducted on the selection of slack buses in load flow analysis. However, varied conclusions regarding the impact on system losses and power flows were obtained during these studies. Therefore, using the IEEE-14 bus test system, this study investigated the effects of slack bus selection in strong and weak grids by alternating slack buses among PV buses and observing the effects on bus voltage magnitude, bus voltage phase angle, total power flows, and active and reactive power losses. The study noted that the effect of slack bus selection on these system quantities is contingent upon the voltage stability of the grid. Whereas in a robust grid, system losses and power flows remained constant irrespective of the choice of slack bus, a weak grid experienced some variations in these system quantities under similar circumstances. The simulation results led to the conclusion that, to a large extent, the voltage stability of the grid plays a significant role in determining the degree to which slack bus selection affects system losses and other quantities in load flow studies.