Plain concrete plate and fiber concrete plate subjected to temperature drop load were analyzed on stochastic finite element method (FEM).It is found that fibers can enhance concrete ability to resist tem- perature dro...Plain concrete plate and fiber concrete plate subjected to temperature drop load were analyzed on stochastic finite element method (FEM).It is found that fibers can enhance concrete ability to resist tem- perature drop load for improving concrete's fracture energy and deferring the crack process.It is found for concrete not to improve apparently its tensile strength and fracture energy is recommended to be its appraisal parameter.展开更多
An experimental study was carried out to investigate the amount of drugs loaded on microneedles. The microneedles were made with poly (lactic acid). Aqueous poly (vinyl alcohol) solutions were prepared as drug solutio...An experimental study was carried out to investigate the amount of drugs loaded on microneedles. The microneedles were made with poly (lactic acid). Aqueous poly (vinyl alcohol) solutions were prepared as drug solutions. Two drug loading approaches, i.e., dropping and dipping, were examined. It was found that capillary number is the only relevant dimensionless group for the two methods. For the dropping approach, dried drugs will spread near the bottom of a microneedle patch provided the surface tension is low. As for the dipping approach, both a single microneedle and an array of nine microneedles were examined. For a single microneedle, high capillary rises before pulling and pulling speed are two key factors to increase the drug loading volume. For an array of microneedles, the effect of capillary rise owing to the interaction between microneedles would increase the drug loading volume several times higher than a single microneedle of the same dimension.展开更多
This study explains the relationship between friction coefficient and pressure change at a range of Reynolds (21,056 - 28,574) and (0 - 1.4) solid loading ratio of two-phase flow (gas-solid) inside a circular copper p...This study explains the relationship between friction coefficient and pressure change at a range of Reynolds (21,056 - 28,574) and (0 - 1.4) solid loading ratio of two-phase flow (gas-solid) inside a circular copper pipe by using laboratory apparatus and solving the equations mathematically. An experimentally relationship of friction coefficient and pressure change with Reynolds number and flow velocity obtained also the relationship between the Solid loading ratio with friction coefficient and pressure change has been done for a Limit range of Reynolds number. It was noticed that the increase in friction coefficient and pressure change for two-phase flow was occurred when solid loading ratio increased. Also the relationship between pressure change and Reynolds number was direct proportion while the relationship between friction coefficient and Reynolds Number was inversely related.展开更多
文摘Plain concrete plate and fiber concrete plate subjected to temperature drop load were analyzed on stochastic finite element method (FEM).It is found that fibers can enhance concrete ability to resist tem- perature drop load for improving concrete's fracture energy and deferring the crack process.It is found for concrete not to improve apparently its tensile strength and fracture energy is recommended to be its appraisal parameter.
文摘An experimental study was carried out to investigate the amount of drugs loaded on microneedles. The microneedles were made with poly (lactic acid). Aqueous poly (vinyl alcohol) solutions were prepared as drug solutions. Two drug loading approaches, i.e., dropping and dipping, were examined. It was found that capillary number is the only relevant dimensionless group for the two methods. For the dropping approach, dried drugs will spread near the bottom of a microneedle patch provided the surface tension is low. As for the dipping approach, both a single microneedle and an array of nine microneedles were examined. For a single microneedle, high capillary rises before pulling and pulling speed are two key factors to increase the drug loading volume. For an array of microneedles, the effect of capillary rise owing to the interaction between microneedles would increase the drug loading volume several times higher than a single microneedle of the same dimension.
文摘This study explains the relationship between friction coefficient and pressure change at a range of Reynolds (21,056 - 28,574) and (0 - 1.4) solid loading ratio of two-phase flow (gas-solid) inside a circular copper pipe by using laboratory apparatus and solving the equations mathematically. An experimentally relationship of friction coefficient and pressure change with Reynolds number and flow velocity obtained also the relationship between the Solid loading ratio with friction coefficient and pressure change has been done for a Limit range of Reynolds number. It was noticed that the increase in friction coefficient and pressure change for two-phase flow was occurred when solid loading ratio increased. Also the relationship between pressure change and Reynolds number was direct proportion while the relationship between friction coefficient and Reynolds Number was inversely related.