Experiment was carried out to simulate different loading level elements under coupling of stray current and 5% chlorine salt solution. When calculating corrosion of reinforcement, the influence of loading should be co...Experiment was carried out to simulate different loading level elements under coupling of stray current and 5% chlorine salt solution. When calculating corrosion of reinforcement, the influence of loading should be considered based on the first law of Faraday electrolysis. The current density of the corrosion was measured by the linear polarization resistance method. The function of corrosion current density was obtained by nonlinear fitting method, and the influence coefficient of loading level to electrochemical equivalent was obtained base on the function of corrosion current density. The experimental results show that the corrosion current density increases with stress ratio of concrete structures. The reinforcement corrosion weight can be calculated through the influence coefficients of electrochemical equivalent and the result is in line with the actual situation.展开更多
The creep behavior of bamboo due to the complicated influences of environment and stress will lead to a sustained increase in deformation,which serious effects the service performance of structures.To investigate the ...The creep behavior of bamboo due to the complicated influences of environment and stress will lead to a sustained increase in deformation,which serious effects the service performance of structures.To investigate the creep behavior of recombinant bamboo,twenty-four recombinant bamboo specimens were tested under lasting compressive and tensile loads at different load levels.The typical failure modes of recombinant bamboo under a lasting load at a high load level were buckling failure and brittle fracturing due to creep compressive creep and tensile creep development,respectively.At a high load level,the creep deformation of recombinant bamboo initially develops unsteadily and increases rapidly until failure;at a low load level,creep deformation rapidly develops in the early stage and stabilizes in the middle and late stages.The load level has notable effects on the overall creep deformation and the proportion of creep deformation.The residual deformation of creep will generally increase and the recovery of creep will decrease with increasing load level.Based on the Burgers model,predictive models that can take the load levels into account were proposed to evaluate the compressive and tensile creep behaviors of recombinant bamboo.The proposed models can be used to accurately evaluate the strain-time behavior of recombinant bamboo.展开更多
Elpipes are polymer-insulated underground HVDC electric pipelines based on metallic conductors.Elpipes use relatively rigid extruded conductors designed for higher capacity and efficiency that are practical for overhe...Elpipes are polymer-insulated underground HVDC electric pipelines based on metallic conductors.Elpipes use relatively rigid extruded conductors designed for higher capacity and efficiency that are practical for overhead power lines.Rigid insulation may be used.In this paper,we discuss the technical trade-offs for elpipes,and application of elpipes linking load centers to remote dispatchable hydro power,energy storage sites,and large dispatchable loads,to achieve load leveling through non-local storage and dispatchable loads,via the HVDC grid.Elpipes with voltage source converters(VSC) enable placing many AC/DC power taps on a single HVDC loop.It is advantageous to build up a continental scale HVDC grid from local loops that tie together 10-20 taps.展开更多
Seismic method is usually used for elastic parametric estimation. This is why this method presents dynamic parameters of Earth. Frequency seismic range changes greatly from geodynamic modelling time. Now we have oppor...Seismic method is usually used for elastic parametric estimation. This is why this method presents dynamic parameters of Earth. Frequency seismic range changes greatly from geodynamic modelling time. Now we have opportunity to use geodesy result for some years for elastic parameters estimation. Static solution from elastic theory may be used for the interpretation of long term results. It presents static elastic parameter. The inverse problem for different types of vertical surface loading on one year period is calculated. Two cases of loading with maximal and minimal area are presented. Results are determined by space geodesy and leveling methods. Current relation between atmospheric pressure and vertical displacements was estimated at the center of Siberian Anti Cyclone with size varied from 2000 km to 3000 kin. Pressure-displacement coefficients (PDC) can be achieved by three years obser- vation (0.997 mm/mbar for NVSK GPS station). It is used for elastic module study of geology medium with maximum thickness up to 600 km. In the context of elastic model, the modulus of rigidity is estimated to be 113 GPa. Vast expanse of anti-cyclone may relate with rheology of crust and upper mantle. Smaller size of surface loading - local loading is seasonal variation of water reservoir. Annual vertical changes were obtained by leveling near the dam of the reservoir. PDC ratio was 1.15 mm/bar for these places. In elastic theory, the Young modulus E = 80 GPa (Poisson ratio = 0.25, the modulus of rigidity - 32 GPa) was calculated by sixteen years of leveling measurements. This result can effectively be represented for upper crust. Our results were checked by solution for coseismic displacement of Chyia- Altai earthquake (Sep. 27, 2003, M = 7.3). Coseismic results calculated by static modules agree with experimental coseismic GPS data at 10% level.展开更多
Cold thermal energy storage is an active method for reducing the peak electrical demand and electricity consumption of air con-ditioners.This paper investigates two different cases:partial operating mode-load levellin...Cold thermal energy storage is an active method for reducing the peak electrical demand and electricity consumption of air con-ditioners.This paper investigates two different cases:partial operating mode-load levelling(POM-LL)and demand-limiting mode(DLM).4E(energy,exergy,economic,environment)analyses along with a multi-objective optimization process based on a genetic algorithm is applied to determine optimal design values.Exergy efficiency,total annual cost and payback-period time are considered as objective functions in this study.The results have shown that POM and DLM decreased the electricity consumption by 10.36%and 11.29%,respectively,resulting in raising the annual costs by 11.08%and 11.42%.Also,their annual payback periods were 4.36 and 4.18 years each.In addition,using off-peak hours instead of on-peak hours for electricity consumption and reducing electricity consump-tion are the two main ways of decreasing CO_(2) emissions during electricity generation.Therefore,the CO_(2) emissions through POM and DLM are 13.31%and 13.72%less than those of conventional systems,respectively.展开更多
To investigate the fire endurance of wood beams exposed to three-side fire, we conducted bearing capacity tests of two wood beams and experiments of five wood beams exposed to three-side fire. The finite element softw...To investigate the fire endurance of wood beams exposed to three-side fire, we conducted bearing capacity tests of two wood beams and experiments of five wood beams exposed to three-side fire. The finite element software ANSYS was also used to predict the fire endurance of those beams with the indirect order coupling method. It was found that the fire endurance decreases as the load level increases, and the reduction ratio tends to decrease. In the case of a certain load level, the fire endurance is improved if the section size is increased or covered by the fire protection coating. The central deformation increases as the fire duration increases, and the ratio of increase tends to rise. On another note, an increase in the density of wood leads to a rise in the fire endurance of a given beam. From the finite element method (FEM) calculation results, the fire endurance decreases as the load level increases, and the reduction ratio tends to decrease. When the load level is greater than 0.5, the fire endurance is significantly reduced, and it does not change significantly when the load level changes. Lastly, for a load level magnitude below 0.5, the fire endurance and load level are proportional to one another.展开更多
According to the service environment of subway structure,experiment is carried out to simulate influence of different loading levels to reinforcement corrosion of R.C element affected by stray current and chlorine sal...According to the service environment of subway structure,experiment is carried out to simulate influence of different loading levels to reinforcement corrosion of R.C element affected by stray current and chlorine salt solution. The current density of the corrosion is measured with the linear polarization resistance method,together with the qualitative analysis and quantitative calculation. Experiment shows that rebar corrosion current density increase accordingly with the increase of loading level. The quantitative relations and the time of rust corrosion of reinforcement are obtained.展开更多
基金Funded by the National Natural Science Foundation of China(No.50808005)the National "11-5" Science and Technology Supporting Program(No.2006BAJ27B04)the Major Program of Beijing Municipal Natural Sci-ence Foundation(No.8100001)and Beijing talent innovation
文摘Experiment was carried out to simulate different loading level elements under coupling of stray current and 5% chlorine salt solution. When calculating corrosion of reinforcement, the influence of loading should be considered based on the first law of Faraday electrolysis. The current density of the corrosion was measured by the linear polarization resistance method. The function of corrosion current density was obtained by nonlinear fitting method, and the influence coefficient of loading level to electrochemical equivalent was obtained base on the function of corrosion current density. The experimental results show that the corrosion current density increases with stress ratio of concrete structures. The reinforcement corrosion weight can be calculated through the influence coefficients of electrochemical equivalent and the result is in line with the actual situation.
基金supported by the National Natural Science Foundation of China(No.51208262 and No.51778300)the Natural Science Foundation of Jiangsu Province(No.BK20191390)+1 种基金the 333 Project(No.BRA2016421)the Qinglan Project of Jiangsu Province(QL2017).
文摘The creep behavior of bamboo due to the complicated influences of environment and stress will lead to a sustained increase in deformation,which serious effects the service performance of structures.To investigate the creep behavior of recombinant bamboo,twenty-four recombinant bamboo specimens were tested under lasting compressive and tensile loads at different load levels.The typical failure modes of recombinant bamboo under a lasting load at a high load level were buckling failure and brittle fracturing due to creep compressive creep and tensile creep development,respectively.At a high load level,the creep deformation of recombinant bamboo initially develops unsteadily and increases rapidly until failure;at a low load level,creep deformation rapidly develops in the early stage and stabilizes in the middle and late stages.The load level has notable effects on the overall creep deformation and the proportion of creep deformation.The residual deformation of creep will generally increase and the recovery of creep will decrease with increasing load level.Based on the Burgers model,predictive models that can take the load levels into account were proposed to evaluate the compressive and tensile creep behaviors of recombinant bamboo.The proposed models can be used to accurately evaluate the strain-time behavior of recombinant bamboo.
文摘Elpipes are polymer-insulated underground HVDC electric pipelines based on metallic conductors.Elpipes use relatively rigid extruded conductors designed for higher capacity and efficiency that are practical for overhead power lines.Rigid insulation may be used.In this paper,we discuss the technical trade-offs for elpipes,and application of elpipes linking load centers to remote dispatchable hydro power,energy storage sites,and large dispatchable loads,to achieve load leveling through non-local storage and dispatchable loads,via the HVDC grid.Elpipes with voltage source converters(VSC) enable placing many AC/DC power taps on a single HVDC loop.It is advantageous to build up a continental scale HVDC grid from local loops that tie together 10-20 taps.
文摘Seismic method is usually used for elastic parametric estimation. This is why this method presents dynamic parameters of Earth. Frequency seismic range changes greatly from geodynamic modelling time. Now we have opportunity to use geodesy result for some years for elastic parameters estimation. Static solution from elastic theory may be used for the interpretation of long term results. It presents static elastic parameter. The inverse problem for different types of vertical surface loading on one year period is calculated. Two cases of loading with maximal and minimal area are presented. Results are determined by space geodesy and leveling methods. Current relation between atmospheric pressure and vertical displacements was estimated at the center of Siberian Anti Cyclone with size varied from 2000 km to 3000 kin. Pressure-displacement coefficients (PDC) can be achieved by three years obser- vation (0.997 mm/mbar for NVSK GPS station). It is used for elastic module study of geology medium with maximum thickness up to 600 km. In the context of elastic model, the modulus of rigidity is estimated to be 113 GPa. Vast expanse of anti-cyclone may relate with rheology of crust and upper mantle. Smaller size of surface loading - local loading is seasonal variation of water reservoir. Annual vertical changes were obtained by leveling near the dam of the reservoir. PDC ratio was 1.15 mm/bar for these places. In elastic theory, the Young modulus E = 80 GPa (Poisson ratio = 0.25, the modulus of rigidity - 32 GPa) was calculated by sixteen years of leveling measurements. This result can effectively be represented for upper crust. Our results were checked by solution for coseismic displacement of Chyia- Altai earthquake (Sep. 27, 2003, M = 7.3). Coseismic results calculated by static modules agree with experimental coseismic GPS data at 10% level.
文摘Cold thermal energy storage is an active method for reducing the peak electrical demand and electricity consumption of air con-ditioners.This paper investigates two different cases:partial operating mode-load levelling(POM-LL)and demand-limiting mode(DLM).4E(energy,exergy,economic,environment)analyses along with a multi-objective optimization process based on a genetic algorithm is applied to determine optimal design values.Exergy efficiency,total annual cost and payback-period time are considered as objective functions in this study.The results have shown that POM and DLM decreased the electricity consumption by 10.36%and 11.29%,respectively,resulting in raising the annual costs by 11.08%and 11.42%.Also,their annual payback periods were 4.36 and 4.18 years each.In addition,using off-peak hours instead of on-peak hours for electricity consumption and reducing electricity consump-tion are the two main ways of decreasing CO_(2) emissions during electricity generation.Therefore,the CO_(2) emissions through POM and DLM are 13.31%and 13.72%less than those of conventional systems,respectively.
基金Project supported by the National Natural Science Foundation of China (No. 51178115)the Priority Academic Program Development of Jiangsu Higher Education Institutionsthe Shanghai Rising-Star Program (Nos. 11QH1402100 and 07QB14031), China
文摘To investigate the fire endurance of wood beams exposed to three-side fire, we conducted bearing capacity tests of two wood beams and experiments of five wood beams exposed to three-side fire. The finite element software ANSYS was also used to predict the fire endurance of those beams with the indirect order coupling method. It was found that the fire endurance decreases as the load level increases, and the reduction ratio tends to decrease. In the case of a certain load level, the fire endurance is improved if the section size is increased or covered by the fire protection coating. The central deformation increases as the fire duration increases, and the ratio of increase tends to rise. On another note, an increase in the density of wood leads to a rise in the fire endurance of a given beam. From the finite element method (FEM) calculation results, the fire endurance decreases as the load level increases, and the reduction ratio tends to decrease. When the load level is greater than 0.5, the fire endurance is significantly reduced, and it does not change significantly when the load level changes. Lastly, for a load level magnitude below 0.5, the fire endurance and load level are proportional to one another.
基金National Natural Science Foundation of China (Granted No.50808005)National"11-5"Science and Technology Supporting Program(Granted No.2006BAJ27B04)Major Program of Beijing Municipal Natural Science Foundation(Granted No.8100001)
文摘According to the service environment of subway structure,experiment is carried out to simulate influence of different loading levels to reinforcement corrosion of R.C element affected by stray current and chlorine salt solution. The current density of the corrosion is measured with the linear polarization resistance method,together with the qualitative analysis and quantitative calculation. Experiment shows that rebar corrosion current density increase accordingly with the increase of loading level. The quantitative relations and the time of rust corrosion of reinforcement are obtained.