RSS-Based Indoor Localization System with Single Base Station
1
作者 Samir Salem Al-Bawri Mohammad Tariqul Islam +4 位作者 Mandeep Jit Singh Mohd Faizal Jamlos Adam Narbudowicz Max J.Ammann Dominique M.M.P.Schreurs 《Computers, Materials & Continua》 SCIE EI 2022年第3期5437-5452,共16页
The paper proposes an Indoor Localization System(ILS)which uses only one fixed Base Station(BS)with simple non-reconfigurable antennas.The proposed algorithm measures Received Signal Strength(RSS)and maps it to the lo... The paper proposes an Indoor Localization System(ILS)which uses only one fixed Base Station(BS)with simple non-reconfigurable antennas.The proposed algorithm measures Received Signal Strength(RSS)and maps it to the location in the room by estimating signal strength of a direct line of sight(LOS)signal and signal of the first order reflection from the wall.The algorithm is evaluated through both simulations and empirical measurements in a furnished open space office,sampling 21 different locations in the room.It is demonstrated the system can identify user’s real-time location with a maximum estimation error below 0.7 m for 80%confidence Cumulative Distribution Function(CDF)user level,demonstrating the ability to accurately estimate the receiver’s location within the room.The system is intended as a cost-efficient indoor localization technique,offering simplicity and easy integration with existing wireless communication systems.Unlike comparable single base station localization techniques,the proposed system does not require beam scanning,offering stable communication capacity while performing the localization process. 展开更多
关键词 Indoor localization localization techniques received signal strength
下载PDF
Identification of LPV system using locally weighted technique
2
作者 ZENG Jiu-sun GAO Chuan-hou LUO Shi-hua 《Applied Mathematics(A Journal of Chinese Universities)》 SCIE CSCD 2010年第4期411-419,共9页
The problem of linear parameter varying (LPV) system identification is considered based on the locally weighted technique which provides estimation of the LPV model parameters at each distinct data time point by giv... The problem of linear parameter varying (LPV) system identification is considered based on the locally weighted technique which provides estimation of the LPV model parameters at each distinct data time point by giving large weights to measurements that are "close" to the current time point and small weights to measurements "far" from the current time point. Issues such as choice of distance function, weighting function and bandwidth selection are discussed. The developed method is easy to implement and simulation results illustrate its efficiency. 展开更多
关键词 Linear parameter varying system locally weighted technique identification.
下载PDF
Simulation Emergency Fire Evacuation Model for Nuclear Power Plant
3
作者 Amany F. Abd El-Aal Adel Zaghloul Magy M. Kandil 《Journal of Power and Energy Engineering》 2021年第4期30-52,共23页
Simulation of egress is vital for minimizing losses during fire disasters, however accurate simulations are scarce and real-life data is hard to come by. In this paper, a Proposed Wireless Fire Evacuation Model (PWFEM... Simulation of egress is vital for minimizing losses during fire disasters, however accurate simulations are scarce and real-life data is hard to come by. In this paper, a Proposed Wireless Fire Evacuation Model (PWFEM) is proposed to simulate fire evacuation process in a short time<span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">to minimize evacuee’s exposure to the harmful radiation and fire hazards. The PWFEM</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">simulation realistic by supposing fire scenario at</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">cabined contains electrical cables inside a standard Main Control Room (MCR) in a Nuclear Power Plant (NPP) building.</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">In addition, a</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">new Hybrid Safest Shortest Exit (HSSE) is developed</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">which consists of three stages: safest route based </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">o</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">n rules-based technique, evacuees location based on the DV-hop technique </span></span></span><span><span><span style="font-family:" color:#c45911;"=""><a href="#ref1" target="_blank"><span style="font-family:Verdana;">[1]</span></a></span><span></span></span></span><span><span></span></span><span></span><span><span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> and shortest route that depends on Dijkstra techniqu</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">e</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">. The PWFEM Simulations </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">are </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">appreciated</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">to yield a realistic fire scenario by using a telecommunications TCP/IP network in</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">form of server and client sides that help in transfer data inside internal networks in the NPP building. </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">O</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">n the server-side, suppose that</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">Consolidated Model of Fire Growth and Smoke Transport (CFAST) fire modeling is applied to simulate the fire scenario in MCR through CFAST model to generate fire products as output data in excel sheets and sends them to the client-side. The client-side then runs HSSE to produce the tree map for safest and shortest routes to help the evacuee for safe exit from his/her location.</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">HSSE can be implemented on evacuee’s watches. From the results, </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">it is </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">concluded that PWFEM can simulate the fire scenario inside MCR,</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">furthermore </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">it is </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">validated that HSEE can be used as an efficient emergency fire evacuation technique that can produce safest and shortest exit route for evacuee in any location inside NPP in very small time. In addition, PWFEM can be used for simulating</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">fire evacuation inside any high-risk buildings and can appreciate</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">yield</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">ing</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> any realistic fire scenario with many types of fire sources in different places inside buildings.</span></span></span> 展开更多
关键词 Fire Safety Fire Evacuation Model NPP Evacuation localization technique CFAST Model DV-Hop technique Dijkstra Algorithm
下载PDF
MICROSCOPIC CORROSION STUDIES OF DUPLEX STAINLESS STEELS 被引量:1
4
作者 C.Leygraf J.Pan M.Femenia 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2004年第5期625-631,共7页
Electrochemical scanning tunneling microscopy and scanning electrochemical microscopy have been used for in situ monitoring of localized corrosion processes of different Duplex stainless steels (DSS) in acidic chlorid... Electrochemical scanning tunneling microscopy and scanning electrochemical microscopy have been used for in situ monitoring of localized corrosion processes of different Duplex stainless steels (DSS) in acidic chloride solutions. The techniques allow imaging of local dissolution events with micrometer resolution, as opposed to conventional electrochemical techniques, which only give an overall view of the corrosion behavior. In addition, combined scanning Kelvin probe force microscopy and magnetic force microscopy were used for mapping the Volta potential variation over the surface of DSSs. A significant difference in Volta potential between the austenite and ferrite phases suggests galvanic interaction between the phases. A compositional gradient appears within 2 micrometers across the phase boundary, as seen with scanning Auger microscopy (SAM). In all, the studies suggest that higher alloyed DSS exhibit a more homogeneous dissolution behavior than lower alloyed DSS, due to higher and more similar corrosion resistance of the two phases, and enhanced resistance of the ferrite/austenite phase boundary regions. 展开更多
关键词 duplex stainless steel corrosion mechanism local electrochemical technique surface analysis micrometer resolution
下载PDF
A correlation between pulse diagnosis of human body and health monitoring of structures
5
作者 C.C.Chang Henry T.Y.Yang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2004年第1期117-125,共9页
The concept of health monitoring is a key aspect of the field of medicine that has been practiced for a long time. A commonly used diagnostic and health monitoring practice is pulse diagnosis, which can be traced back... The concept of health monitoring is a key aspect of the field of medicine that has been practiced for a long time. A commonly used diagnostic and health monitoring practice is pulse diagnosis, which can be traced back approximately five thousand years in the recorded history of China. With advances in the development of modern technology, the concept of health monitoring of a variety of engineering structures in several applications has begun to attract widespread attention. Of particular interest in this study is the health monitoring of civil structures. It seem natural, and even beneficial, that these two health-monitoring methods, one as applies to the human body and the other to civil structures, should be analyzed and compared. In this paper, the basic concepts and theories of the two monitoring methods are first discussed. Similarities are then summarized and commented upon. It is hoped that this correlation analysis may help provide structural engineers with some insights into the intrinsic concept of using pulse diagnosis in human health monitoring, which may of be some benefit in the development of modern structural health monitoring methods. 展开更多
关键词 human health monitoring pulse diagnosis structural health monitoring vibration-based techniques local detection techniques
下载PDF
Snapping wrist due to bony prominence and tenosynovitis of the first extensor compartment:A case report
6
作者 Chia Jung Hu Po-Chin Chow I-Shiang Tzeng 《World Journal of Clinical Cases》 SCIE 2021年第16期3908-3913,共6页
BACKGROUND A snapping wrist is a rare symptom that results from the sudden impingement of one anatomic structure against another,subsequently causing a sudden movement only during wrist movement.CASE SUMMARY A 30-year... BACKGROUND A snapping wrist is a rare symptom that results from the sudden impingement of one anatomic structure against another,subsequently causing a sudden movement only during wrist movement.CASE SUMMARY A 30-year-old woman with a history of right wrist contusion reported right wrist snapping after overuse.The snapping became symptomatic after moving heavy objects.The pain persisted even when she received 1 mo of conservative treatment.Physical examination showed painful wrist snapping during wrist radioulnar motion and thumb abduction-adduction.Radiography demonstrated bone overgrowth over the radial styloid process.Sonography disclosed a tendon jumping over a bony prominence in the first compartment during wrist motion.Magnetic resonance imaging revealed no anomalous tendon nor tumorlike lesion.Under the wide-awake local anesthesia no tourniquet(WALANT)technique,the lesion was identified in the first extensor compartment.The patient received stepwise extensor retinaculum release,synovectomy,and bone spur removal.By 6th week,the patient was completely free of pain and unable to snap her wrist.She started working 7 wk after the surgery.One year after the surgery,the wrist snap was not recurrent.CONCLUSION Careful physical examination and dynamic sonography may confirm the diagnosis of a snapping wrist.With the WALANT technique,the lesion could be identified under direct vision,and we could take stepwise interventions according to intraoperative presentations. 展开更多
关键词 Snapping wrist TENOSYNOVITIS Wide-awake local anesthesia no tourniquet technique Orthopedics Snapping syndromes WRIST Case report