期刊文献+
共找到24,438篇文章
< 1 2 250 >
每页显示 20 50 100
On the generation of high-quality Nyquist pulses in mode-locked fiber lasers
1
作者 任俞宣 葛锦蔓 +2 位作者 李小军 彭俊松 曾和平 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期424-427,共4页
Nyquist pulses have wide applications in many areas,from electronics to optics.Mode-locked lasers are ideal platforms to generate such pulses.However,how to generate high-quality Nyquist pulses in mode-locked lasers r... Nyquist pulses have wide applications in many areas,from electronics to optics.Mode-locked lasers are ideal platforms to generate such pulses.However,how to generate high-quality Nyquist pulses in mode-locked lasers remains elusive.We address this problem by managing different physical effects in mode-locked fiber lasers through extensive numerical simulations.We find that net dispersion,linear loss,gain and filter shaping can affect the quality of Nyquist pulses significantly.We also demonstrate that Nyquist pulses experience similariton shaping due to the nonlinear attractor effect in the gain medium.Our work may contribute to the design of Nyquist pulse sources and enrich the understanding of pulse shaping dynamics in mode-locked lasers. 展开更多
关键词 mode locking laser SOLITON FIBER PULSE
下载PDF
Dissipative soliton resonance within different dispersion regimes in a single mode-locked laser
2
作者 赵哲韬 舒沁珂 +6 位作者 解梓怡 任俞宣 张颖 袁博 赵春勃 彭俊松 曾和平 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第7期368-372,共5页
Dissipative soliton resonance(DSR) was previously studied in separated mode-locked fiber lasers within different dispersion regimes including anomalous, near-zero and normal dispersion. Here we propose a method to stu... Dissipative soliton resonance(DSR) was previously studied in separated mode-locked fiber lasers within different dispersion regimes including anomalous, near-zero and normal dispersion. Here we propose a method to study DSR in a single mode-locked laser in these different dispersion regimes. This is achieved by virtue of a waveshaper which can control the laser dispersion readily using software, avoiding the usual tedious cutback method. We find that dispersion has a negligible effect on DSR since the pulse duration keeps constant while dispersion is varied. Moreover, we examine the dynamics of DSR on the parameters of the SA including modulation depth and saturation power, and find that the pulse duration can be changed in a large range when the saturation power is decreased. Our numerical simulations could be important to guide relative experimental studies. 展开更多
关键词 mode locking LASER FIBER PULSE
下载PDF
Phase-locked single-mode terahertz quantum cascade lasers array
3
作者 Yunfei Xu Weijiang Li +9 位作者 Yu Ma Quanyong Lu Jinchuan Zhang Shenqiang Zhai Ning Zhuo Junqi Liu Shuman Liu Fengmin Cheng Lijun Wang Fengqi Liu 《Journal of Semiconductors》 EI CAS CSCD 2024年第6期87-91,共5页
We demonstrated a scheme of phase-locked terahertz quantum cascade lasers(THz QCLs)array,with a single-mode pulse power of 108 mW at 13 K.The device utilizes a Talbot cavity to achieve phase locking among five ridge l... We demonstrated a scheme of phase-locked terahertz quantum cascade lasers(THz QCLs)array,with a single-mode pulse power of 108 mW at 13 K.The device utilizes a Talbot cavity to achieve phase locking among five ridge lasers with first-order buried distributed feedback(DFB)grating,resulting in nearly five times amplification of the single-mode power.Due to the optimum length of Talbot cavity depends on wavelength,the combination of Talbot cavity with the DFB grating leads to better power amplification than the combination with multimode Fabry-Perot(F-P)cavities.The Talbot cavity facet reflects light back to the ridge array direction and achieves self-imaging in the array,enabling phase-locked operation of ridges.We set the spacing between adjacent elements to be 220μm,much larger than the free-space wavelength,ensuring the operation of the fundamental supermode throughout the laser's dynamic range and obtaining a high-brightness far-field distribution.This scheme provides a new approach for enhancing the single-mode power of THz QCLs. 展开更多
关键词 quantum cascade lasers phase locking TERAHERTZ single mode
下载PDF
A novel dual-channel thermo-optic locking method for the whispering gallery mode microresonator
4
作者 范文杰 刘文耀 +6 位作者 潘梓文 王蓉 刘来 邢恩博 周彦汝 唐军 刘俊 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期438-444,共7页
Mode locking can be effectively achieved by using the thermo-optic effects in the whispering gallery mode(WGM)optical microcavity,without the help of external equipment.Therefore,it has the advantages of small size,lo... Mode locking can be effectively achieved by using the thermo-optic effects in the whispering gallery mode(WGM)optical microcavity,without the help of external equipment.Therefore,it has the advantages of small size,low integration costs,and self-locking,which shows great potential for application.However,the conventional single-channel microcavity thermal-locking method that relies solely on internal thermal balance will inevitably be disturbed by the external environment.This limitation affects the locking time and stability.Therefore,in this paper,we propose a new method for closed-loop thermal locking of a dual-channel microcavity.The thermal locking of the signal laser and the thermal regulation of the control laser are carried out respectively by synchronously drawing a dual-path tapered fiber.The theoretical model of the thermal dynamics of the dual-channel microcavity system is established,and the influence of the control-laser power on the thermal locking of the signal laser is confirmed.The deviation between the locking voltage of the signal laser and the set point value is used as a closed-loop feedback parameter to achieve long-term and highly stable mode locking of the signal laser.The results show that in the 2.63 h thermal-locking test,the locking stability is an order of magnitude higher than that of the single tapered fiber.This solution addresses the issue of thermal locking being disrupted by the external environment,and offers new possibilities for important applications such as spectroscopy and micro-optical sensor devices. 展开更多
关键词 optical microcavity thermo-optic locking thermal nonlinearity effect
下载PDF
Early Treatment Outcome of Humeral Shaft Fracture Non-Union in Adults: Comparative Study of Plating versus Interlocking Nailing
5
作者 Abdullallahi Bello Galadima Lukman Olalekan Ajiboye +1 位作者 Muhammad Nuhu Salihu Isha Nurudeen 《Health》 2024年第4期371-381,共11页
Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is... Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is a major problem in this part of the world. This non-union is a major treatment challenge with increased cost of care and morbidity in this part of the world. Humeral shaft non-union can be treated with locked intra-medullary nailing (LIMN) or dynamic compression plating (DCP). Study on comparison of these methods of fixation in this part of the world is scarce in literature search, hence the reason for this study. Objective: The objectives of this study are: (1) to compare early clinical outcome following fixation of humeral shaft fracture nonunion with DCP versus LIMN;(2) to compare the time of radiologic fracture union of DCP with LIMN;(3) to compare complications following fixation of humeral shaft fracture nonunion with DCP versus LIMN. Patients and Methods: This was a randomized control study done for 2 years in which fifty adult patients with humeral shaft non-union were recruited. The patients were grouped into 2 (P = DCP & N = LIMN). Forty five of the patients completed the follow up periods of the study and then analyzed. The P group had ORIF with DCP while the N group had ORIF with LIMN. Both groups had grafting with cancellous bones. Each patient was followed up for a period of 6 months at the time which radiographic union is expected. Any patient without clinical and/or radiographic evidence of union after six months of surgery was diagnosed as having recurrent non-union. The data generated was analyzed using SPSS Version 23. The results were presented in charts and tables. The paired t-test was used while considering p value Result: Forty five patients completed follow up. There was a male preponderance (4:1), right humerus predominated (3:2). Motor vehicular accidents were the commonest cause of the fractures (62%). Most non-union fractures occurred at the level of the middle 3<sup>rd</sup> of the humeral shaft (60%). Failed TBS treatment was the commonest indication for the osteosynthesis (71%). More patients had plating (53%) compared to 47% who had LIMN. Most patients (93.4%) had union between 3 to 6 months irrespective of fixation type with no significant statistical difference between the union rate of DCP and LIMN (p value 0.06) with similar functional outcome and complication rates irrespective of the type of fixation. Conclusion: This study showed that the success rates in term of fracture union, outcome functional grades and complication rates were not directly dependent on the types of the fixation: plating or locked intra-medullary nailing. 展开更多
关键词 Humeral Shaft NON-UNION Dynamic Compression Plating locked Intra-Medullary Nailing Early Treatment Outcome Early Outcome
下载PDF
Unlocking Cellular Mysteries:Advancements in Single-Cell Omics Analysis with Genome-Scale Metabolic Modeling
6
《Bulletin of the Chinese Academy of Sciences》 2024年第1期52-52,共1页
The widespread applications of single-cell technologies have generated a large amount of single-cell data,resulting in a growing need for single-cell data analysis and interpretation methods.While methods such as mach... The widespread applications of single-cell technologies have generated a large amount of single-cell data,resulting in a growing need for single-cell data analysis and interpretation methods.While methods such as machine learning allow for single-cell data analysis,they cannot interpret the data very well. 展开更多
关键词 methods. METABOLIC lockING
下载PDF
Dynamic behaviors of rockslides subjected to brittle failure of locked segments 被引量:1
7
作者 HU Kai ZHAO Xiao-yan ZHANG Guang-ze 《Journal of Mountain Science》 SCIE CSCD 2023年第2期532-541,共10页
Locked segments are recognized as a critical role that controls the stability of rock slopes but remain an unclear and challenging problem with respect to their role incorporated into the failure mechanism.In order to... Locked segments are recognized as a critical role that controls the stability of rock slopes but remain an unclear and challenging problem with respect to their role incorporated into the failure mechanism.In order to study the effect of the locked segments on the initial failure process of rockslides,thirty-six groups of locked segment specimens with three different lithologies were prepared,direct shear tests were carried out to obtain the accelerations caused by brittle failure of the locked segment specimens.Experiment results showed that the maximum accelerations caused by the brittle failure of locked segment specimens was 2.91 g in the horizontal direction,and 3.18 g in the vertical direction.We took the Wangjiayan rockslide in 2008 Wenchuan earthquake as an example,the critical balance condition of the sliding mass under combined effect of gravity and accelerations induced by brittle failure of locked segment was analyzed,which indicated that the initial failure process of the Wangjiayan rockslides was notably influenced by the existence of the locked segment.The departure acceleration and direction of the Wangjiayan rockslide were proposed.The study results can provide a new insight into the understanding of the initial failure mechanism of rockslides with locked segments. 展开更多
关键词 Rockslides ROCKFALLS locked segment Direct shear test Initial failure mechanism Sudden departure Brittle failure
下载PDF
Locking plates for distal fibula fractures in young and elderly patients:A retrospective study 被引量:1
8
作者 Francesco Roberto Evola Giovanni Francesco Di Fede +3 位作者 Giuseppe Evola Martina Barchitta Antonella Agodi Gianfranco Longo 《World Journal of Orthopedics》 2023年第7期540-546,共7页
BACKGROUND Ankle fractures are common injuries in the young and elderly populations.To prevent post-traumatic arthritis,an anatomic reconstruction of the ankle structure is mandatory.Open reduction and internal fixati... BACKGROUND Ankle fractures are common injuries in the young and elderly populations.To prevent post-traumatic arthritis,an anatomic reconstruction of the ankle structure is mandatory.Open reduction and internal fixation is the treatment of choice among orthopaedics.Conventional plates allow stability of the fracture if bone quality is present.Locking plates might offer an advantage for the treatment of lateral malleolar fracture in patients with comminution,severe instability,distal fractures,or osteoporotic bone.Our hospital introduced a new locking plate for fracture of the distal fibula.AIM To evaluate locking plates in terms of outcomes and complications in young and elderly patients.METHODS We retrospectively reviewed a total of 67 patients treated for displaced distal fibula fractures.Demographic data,number of comorbidities,use of inter fragmentary screw,complication,time of fracture healing,partial or full weight bearing,and reoperation were recorded for all patients.Clinical outcome was assessed by the American Orthopedic Foot and Ankle Society clinical scoring system.Radiographs were obtained at 4,8,12,16,20,and 24 wk until radiographic union was obtained.RESULTS All patients displayed complete bony union on radiographic assessment,and no patients developed any serious complications.We observed two superficial infections,one delayed wound healing,and two plate intolerances.Significant differences were observed between the two age groups in terms of radiographic healing(11.9 wk in younger patients vs 13.7 wk in older patients;P=0.011)and in the American Orthopedic Foot and Ankle Society score at 6 mo after surgery(88.2 in younger patients vs 86.0 in older patients;P=0.001)and at 12 mo after surgery(92.6 in younger patients vs 90.0 in older patients;P=0.000).CONCLUSION Locking plates provide a stable and rigid fixation in multifragmentary and comminuted fractures or in the presence of poor bone quality. 展开更多
关键词 Ankle fracture locking plate Distal fibula fracture OUTCOME COMPLICATIONS OSTEOPOROSIS
下载PDF
Perspectives of spin-valley locking devices
9
作者 陶玲玲 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第10期15-21,共7页
Valleytronics is an emerging field of research which utilizes the valley degree of freedom to encode information.However,it is technically nontrivial to produce a stable valley polarization and to achieve efficient co... Valleytronics is an emerging field of research which utilizes the valley degree of freedom to encode information.However,it is technically nontrivial to produce a stable valley polarization and to achieve efficient control and manipulation of valleys.Spin–valley locking refers to the coupling between spin and valley degrees of freedom in the materials with large spin–orbit coupling(SOC)and enables the manipulation of valleys indirectly through controlling spins.Here,we review the recent advances in spin–valley locking physics and outline possible device implications.In particular,we focus on the spin–valley locking induced by SOC and external electric field in certain two-dimensional materials with inversion symmetry and demonstrate the intriguing switchable valley–spin polarization,which can be utilized to design the promising electronic devices,namely,valley-spin valves and logic gates. 展开更多
关键词 spin–valley locking SPINTRONICS valleytronics spin–orbit coupling
下载PDF
An injection-locking diode laser at 671 nm with a wide tuning range up to 6 GHz
10
作者 宋红芳 沈玥 李可 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第9期60-66,共7页
We present a compact injection-locking diode laser module to generate 671 nm laser light with a high output power up to 150 m W.The module adopts a master-slave injection-locking scheme,and the injection-locking state... We present a compact injection-locking diode laser module to generate 671 nm laser light with a high output power up to 150 m W.The module adopts a master-slave injection-locking scheme,and the injection-locking state is monitored using the transmission spectrum from a Fabry-Perot interferometer.Beat frequency spectrum measurement shows that the injection-locked slave laser has no other frequency components within the 150-MHz detection bandwidth.It is found that without additional electronic feedback,the slave laser can follow the master laser over a wide range of 6 GHz.All the elements of the module are commercially available,which favors fast construction of a complete 671-nm laser system for the preparation of cold^(6)Li atoms with only one research-grade diode laser as the seeding source. 展开更多
关键词 injection lock diode laser ^(6)Li atoms
下载PDF
Locked nucleic acid real-time polymerase chain reaction method identifying two polymorphisms of hepatitis B virus genotype C2 infections,rt269L and rt269I
11
作者 Kijeong Kim Yu-Min Choi +3 位作者 Dong Hyun Kim Junghwa Jang Won Hyeok Choe Bum-Joon Kim 《World Journal of Gastroenterology》 SCIE CAS 2023年第11期1721-1734,共14页
BACKGROUND The presence of two distinct hepatitis B virus(HBV)Pol RT polymorphisms,rt269L and rt269I,could contribute to the unique clinical or virological phenotype of HBV genotype C2.Therefore,a simple and sensitive... BACKGROUND The presence of two distinct hepatitis B virus(HBV)Pol RT polymorphisms,rt269L and rt269I,could contribute to the unique clinical or virological phenotype of HBV genotype C2.Therefore,a simple and sensitive method capable of identifying both types in chronic hepatitis B(CHB)patients infected with genotype C2 should be developed.AIM To develop a novel simple and sensitive locked nucleic acid(LNA)-real timepolymerase chain reaction(RT-PCR)method capable of identifying two rt269 types in CHB genotype C2 patients.METHODS We designed proper primer and probe sets for LNA-RT-PCR for the separation of rt269 types.Using synthesized DNAs of the wild type and variant forms,melting temperature analysis,detection sensitivity,and endpoint genotyping for LNA-RT-PCR were performed.The developed LNA-RT-PCR method was applied to a total of 94 CHB patients of genotype C2 for the identification of two rt269 polymorphisms,and these results were compared with those obtained by a direct sequencing protocol.RESULTS The LNA-RT-PCR method could identify two rt269L and rt269I polymorphisms of three genotypes,two rt269L types[‘L1’(WT)and‘L2’]and one rt269I type(‘I’)in single(63 samples,72.4%)or mixed forms(24 samples,27.6%)in 87(92.6%sensitivity)of 94 samples from Korean CHB patients.When the results were compared with those obtained by the direct sequencing protocol,the LNA-RT-PCR method showed the same results in all but one of 87 positive detected samples(98.9%specificity).CONCLUSION The newly developed LNA-RT-PCR method could identify two rt269 polymorphisms,rt269L and rt269I,in CHB patients with genotype C2 infections.This method could be effectively used for the understanding of disease progression in genotype C2 endemic areas. 展开更多
关键词 Hepatitis B virus Genotype C2 POLYMERASE rt269 locked nucleic acid-real time-polymerase chain reaction Chronic hepatitis B
下载PDF
Knee locking caused by osteochondroma of the proximal tibia adjacent to the pes anserinus:A case report
12
作者 Tatsuru Sonobe Michiyuki Hakozaki +3 位作者 Yohei Matsuo Yojiro Takahashi Katsuhiro Yoshida Shinichi Konno 《World Journal of Clinical Cases》 SCIE 2023年第23期5595-5601,共7页
BACKGROUND Osteochondroma is one of the most common benign bone tumors,and it may cause bone and joint deformities and limited range of motion of an adjacent joint.The pes anserinus region is one of the most frequent ... BACKGROUND Osteochondroma is one of the most common benign bone tumors,and it may cause bone and joint deformities and limited range of motion of an adjacent joint.The pes anserinus region is one of the most frequent sites of osteochondroma,but knee locking caused by osteochondromas in the pes anserinus region is extremely rare.CASE SUMMARY We describe a 13-year-old Japanese girl’s extra-articular knee locking that occurred when the semitendinosus tendon got caught in osteochondroma that had developed in the pes anserinus region.The osteochondroma was surgically resected.The postoperative outcome has been excellent,with no recurrence of knee locking or tumor one-year post-surgery.CONCLUSION When a young person develops knee locking,the possibility of extra-articular as well as intra-articular locking should be considered.Osteochondroma,one of the causes of extra-articular locking,can be treated with surgery with good postoperative results. 展开更多
关键词 Extra-articular knee locking Impingement OSTEOCHONDROMA Pes anserinus Tibia Surgery Case report
下载PDF
Triggering,clicking,locking and crepitus of the finger:A comprehensive overview
13
作者 Pieter W Jordaan Raymond Klumpp Marco Zeppieri 《World Journal of Orthopedics》 2023年第10期733-740,共8页
Triggering,locking,clicking,and crepitus of the fingers are common symptoms patients present with.Even though crepitus and triggering can occur as part of the same underlying diagnosis,it is important to differentiate... Triggering,locking,clicking,and crepitus of the fingers are common symptoms patients present with.Even though crepitus and triggering can occur as part of the same underlying diagnosis,it is important to differentiate between them,as they usually indicate different possible diagnoses.The differential diagnoses that should be considered include trigger finger,metacarpophalangeal joint(MCPJ)arthritis,fractures or dislocations,extensor digitorum communis subluxation or dislocation,locked MCPJ,avascular necrosis of the metacarpal head,and Dupuytren’s disease.A thorough clinical examination with appropriate special investigations can permit the clinician to make the correct diagnosis.Appropriate management of a confirmed diagnosis is successful in providing symptomatic improvement. 展开更多
关键词 Trigger finger lockING Crepitus Metacarpophalangeal joint DISLOCATION Differential diagnosis
下载PDF
高渗透率下基于并网逆变器阻抗重塑的锁相环设计方法 被引量:3
14
作者 杨明 杨倬 +2 位作者 李玉龙 赵月圆 朱军 《电工技术学报》 EI CSCD 北大核心 2024年第2期554-566,共13页
针对锁相环、电网阻抗与并网逆变器相互耦合所引发的系统稳定性下降问题。首先,建立考虑电网阻抗的锁相环控制结构模型,通过分析锁相环闭环传递函数可知,电网阻抗会使锁相环系统产生右半平面闭环极点,严重影响锁相环与逆变器系统的稳定... 针对锁相环、电网阻抗与并网逆变器相互耦合所引发的系统稳定性下降问题。首先,建立考虑电网阻抗的锁相环控制结构模型,通过分析锁相环闭环传递函数可知,电网阻抗会使锁相环系统产生右半平面闭环极点,严重影响锁相环与逆变器系统的稳定性。其次,通过分析逆变器系统输出阻抗,说明锁相环所引入的负阻抗是逆变器系统稳定裕度下降的主要原因。鉴于此,该文提出一种新型锁相环设计方法,理论分析表明,所提方法既能够保证高渗透率下锁相环具有高鲁棒性,又能够对逆变器系统输出阻抗进行重塑,有效拓宽系统对电网阻抗的适应范围。最后,通过仿真与实验验证所提新型锁相环设计方法的有效性。 展开更多
关键词 高渗透率 并网逆变器 锁相环 阻抗重塑 鲁棒性
下载PDF
Surgical Treatment of Olecranon Fractures Using a Medartis Screw-Locked H-Shaped Plate (Medartis Trilock Olecrane Plate) at the Moulins Yzeure Hospital Center (France)
15
作者 Saint Luc Mungina Sedou Charlène Tshitala +2 位作者 Hocine Benyahia Kadinekene Kapuku Kibadi Kapay 《Surgical Science》 2023年第11期673-680,共8页
Introduction: Olecranon fractures represent approximately 10% of upper limb fractures, orthopedic treatment is often doomed to failure and surgical treatment consists of fixing the fracture sites. Patients and Methods... Introduction: Olecranon fractures represent approximately 10% of upper limb fractures, orthopedic treatment is often doomed to failure and surgical treatment consists of fixing the fracture sites. Patients and Methods: This study retrospectively analyzed 130 patients, 90 men and 40 women, aged on average 48.7 ± 11.9 years (30 to 65) treated between 2018 and 2020 in the Orthopedics and trauma department at the Moulins-Yzeure hospital center, for olecranon fracture using the Medartis H-locked plate. The study aimed to evaluate the results of this surgical method, particularly with regard to postoperative complications. Results: Among the 130 patients, there were 90 men and 40 women, with an average age of 48.7 ± 11.9 years (30 to 65). 50% of all patients were aged over 51 years. The plate used was standard, the same for the 130 patients with the same operating technique. The left side was more affected at 53.8%, the dominant side was less affected at 46%;the majority of patients had been temporarily immobilized with a posterior cast splint before surgery. The average time between trauma and operation was 9 days with a minimum time of 1 day and a maximum of 30 days. At a maximum follow-up of 2 years postoperatively, all patients reported satisfactory results with a return to their previous activities within 60 days after surgery. Conclusion: Medartis H-locked plate osteosynthesis is a reliable solution for the surgical treatment of olecranon fractures. 展开更多
关键词 Olecranon Fracture Treatment SURGERY locked Plate Medartis
下载PDF
Locked Posterior Shoulder Dislocation with Impression Fracture Treated All Arthroscopically with the Use of an Allograft Bone Block: A Case Report
16
作者 Adrian Błasiak Mikołaj Podsiadło +1 位作者 Marek Śliwa Roman Brzóska 《Open Journal of Orthopedics》 2023年第1期31-40,共10页
Background: Locked posterior shoulder dislocations are uncommon and possess many difficulties in diagnosis. They are often overlooked during the initial examination and delayed diagnosis adversely affects healing proc... Background: Locked posterior shoulder dislocations are uncommon and possess many difficulties in diagnosis. They are often overlooked during the initial examination and delayed diagnosis adversely affects healing process. Apart from many open treatment options, there are reports of single attempts to treat such cases arthroscopically. Purpose: We present an original case of a posterior locked dislocation of the shoulder joint with a fracture of the lesser tuberosity followed by reverse Hill-Sachs fracture, treated in a novel fashion all-arthroscopically with the use of allogenic bone graft. Method: According to Constant Shoulder Score that tries to assess functional and subjective performance of the shoulder joint before the operation and after 12 months, we achieved a leap from 11 to 84. Results: The patient restored almost full range of motion and painless movement in activities of daily life as well as during sports. Conclusion: The use of an arthroscope reduces the invasiveness of the procedure, improves visualization of the joint and allows augmentation of the bone loss without performing an open approach. We believe that this is a promising method of treatment for selected cases of locked posterior shoulder dislocation. 展开更多
关键词 locked Posterior Shoulder Dislocation ARTHROSCOPY Bone Graft Case Report
下载PDF
弱电网下基于电网电压前馈的并网逆变器阻抗重塑控制策略 被引量:2
17
作者 杨明 杨倬 +1 位作者 李玉龙 朱军 《电工技术学报》 EI CSCD 北大核心 2024年第8期2553-2566,共14页
弱电网下,锁相环在基波以上频段引入的负阻特性,会降低系统输出阻抗的相位,严重影响系统稳定性。鉴于此,该文通过系统控制框图等效变换,推导得到可以消除锁相环负阻特性的电网电压前馈函数,进而提出一种基于电网电压前馈控制的并网逆变... 弱电网下,锁相环在基波以上频段引入的负阻特性,会降低系统输出阻抗的相位,严重影响系统稳定性。鉴于此,该文通过系统控制框图等效变换,推导得到可以消除锁相环负阻特性的电网电压前馈函数,进而提出一种基于电网电压前馈控制的并网逆变器阻抗重塑控制策略。同时,为了提高该策略的普适性,该文利用函数近似和多目标约束为电网电压前馈函数的优化提供两种设计方法,并从系统基波电流跟踪性能、并网功率因数等方面进行误差分析,从而证明其函数优化设计方法的可行性。理论分析表明,优化后的电网电压前馈控制策略,可以有效地对系统输出阻抗相位特性进行重塑,很大程度上拓宽了系统对电网阻抗的适应范围。最后,通过仿真与实验验证所提控制策略的有效性。 展开更多
关键词 弱电网 并网逆变器 阻抗重塑 锁相环 稳定性
下载PDF
锁定钢板联合皮质螺钉内固定治疗踝关节骨折伴下胫腓分离对踝关节功能及生活质量的影响 被引量:2
18
作者 韦志坤 王旭东 +3 位作者 杨金杰 牛朋彦 邵菲 任少海 《临床外科杂志》 2024年第1期71-74,共4页
目的 探讨锁定钢板联合皮质螺钉内固定治疗踝关节骨折伴下胫腓分离对踝关节功能及生活质量的影响。方法 2020年5月~2021年12月我院收治的踝关节骨折伴下胫腓分离病人120例,依据随机数字表法将其分为对照组和观察组,每组各60例。对照组... 目的 探讨锁定钢板联合皮质螺钉内固定治疗踝关节骨折伴下胫腓分离对踝关节功能及生活质量的影响。方法 2020年5月~2021年12月我院收治的踝关节骨折伴下胫腓分离病人120例,依据随机数字表法将其分为对照组和观察组,每组各60例。对照组采用单纯皮质螺钉固定治疗,观察组采用锁定钢板联合皮质螺钉内固定治疗。术前、术后6个月对两组恢复功能对比,比较X线片、手术时间、愈合时间、术中失血量,术后并发症,生活能力(BI)评估两组病人生活能力。依照美国足踝外科协会评分系统评估病人踝关节功能。结果 术前两组病人关节功能无差异(P>0.05),术后,对照组最远行走评分(15.89±0.85)分、足部对线评分(15.06±0.71)分、疼痛反应评分(29.03±4.48)分、地面行走评分(15.65±0.59)分;观察组分别为(16.19±0.87)分、(15.29±0.76)分、(31.24±4.55)分、(15.96±0.68)分。观察组最远行走、足部对线、疼痛反应、地面步行高于对照组,差异有统计学意义(P<0.05)。与对照组比较,观察组术中出血量少,愈合时间较短,差异有统计学意义(P<0.05)。术前两组BI指数比较,差异无统计学意义(P>0.05);观察组术后BI指数高于对照组,两组比较,差异有统计学意义(P<0.05)。两组并发症总发生率比较无差异(P>0.05)。结论 锁定钢板联合皮质螺钉内固定技术治疗踝关节骨折合并下胫腓分离,可改善踝关节功能,降低术中出血量,促进愈合,提高生活能力。 展开更多
关键词 踝关节骨折 下胫腓分离 锁定钢板 皮质螺钉内固定 踝关节功能
下载PDF
Locke’s Tolerance Theory and the Workmanship Argument
19
作者 WU Yuntong ZHANG Lidan 《Cultural and Religious Studies》 2023年第11期549-554,共6页
John Locke’s tolerance theory involves the core issue of the relationship between reason and belief in the philosophy of religion.However,there is always controversy over whether the scope of adaptation of this theor... John Locke’s tolerance theory involves the core issue of the relationship between reason and belief in the philosophy of religion.However,there is always controversy over whether the scope of adaptation of this theory is within a religion,between religions,or in a broader field.Considering that the overall moral approach of Locke’s philosophy requires the workmanship argument as a defense,and examining it from this point of view,it can be found that Locke’s efforts to transcend Creationism with this argument have resulted in a successful breakthrough,which makes tolerance not only a religion topic,but also a social principle. 展开更多
关键词 John locke the workmanship argument tolerance theory moral approach
下载PDF
基于改进正交锁相环的永磁同步电机无位置传感器控制 被引量:1
20
作者 吴翔 陈硕 +2 位作者 李佳 张甲哲 张晓 《电工技术学报》 EI CSCD 北大核心 2024年第2期475-486,共12页
针对传统正交锁相环(QPLL)应用于永磁同步电机无位置传感器控制中存在的反转失效与加、减速工况下出现显著的转子位置直流偏移误差问题,该文提出一种改进的正交锁相环(IQPLL)。其通过重构鉴相器环节,使得鉴相器的输出与永磁同步电机的... 针对传统正交锁相环(QPLL)应用于永磁同步电机无位置传感器控制中存在的反转失效与加、减速工况下出现显著的转子位置直流偏移误差问题,该文提出一种改进的正交锁相环(IQPLL)。其通过重构鉴相器环节,使得鉴相器的输出与永磁同步电机的转向不再相关,从而解决传统QPLL在电机反转时估算转子位置出现180°偏差的问题。此外,在新型鉴相器结构下,设计前馈环路以补偿加、减速工况下的位置直流偏移误差。并建立了IQPLL的小信号模型,根据系统的频率响应特性给出了IQPLL的参数设计方法。实验结果表明,相对于传统的QPLL,所提出的IQPLL可实现永磁同步电机无位置传感器控制正、反转稳定运行,并有效抑制了加、减速工况下的转子位置直流偏移误差。 展开更多
关键词 永磁同步电机 正交锁相环 无位置传感器控制
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部