Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability,...Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experiment was performed in torsion, compression, and bending tests with four different screw configurations: (I) one medial-to-lateral and one oblique, (II) two me-dial-to-lateral, (III) one medial-to-lateral and one anterior-to-posterior, and (IV) one medial-to-lateral, one anterior-to-posterior and one oblique in simu-lated distal metaphyseal fracture tibiae. Twenty- four Synthes EXPERT tibial IM nails were used for six specimens of each screw configuration. Parts I and II, tibial IM nails were locked with 5.0 mm in-terlocking screws into simulated distal tibiae (PVC and composite analogue tibia). Part III, the two most stable configurations were tested using five pairs of simulated cadaveric distal tibiae metaphy-seal fractures. Results: Significant differences were attributable to distal screw orientation for intrame- dullary nailing of distal tibia fractures. Configura-tions II and IV were found to be more stable than the other two configurations. No significant differ-ence was detected in construct stability in all modes of testing between Configurations II and IV. Dis-cussion: Configuration I did not provide superior stability for the distal tibia fracture fixation. Con-figurations II and IV provided equivalent stability. When choosing IM fixation for treatment of distal tibia metaphyseal fractures two medial-to-lateral screws provide the necessary stability for satisfac-tory fixation. Clinical Relevance: This study indi-cated an option for operative treatment of distal metaphyseal tibia fracture fixation where preserva-tion of soft tissue and rigid stabilization are needed.展开更多
AIM To determine factors correlated with postoperative radial shortening in patients with distal radius fractures treated with volar locking distal radius plates.METHODS A total of 250 patients with a distal radius fr...AIM To determine factors correlated with postoperative radial shortening in patients with distal radius fractures treated with volar locking distal radius plates.METHODS A total of 250 patients with a distal radius fracture stabilised with volar locking plates between January 2010 and December 2014 were included in a multicentre retrospective cohort study. We measured the distance of the distal locking screws to the joint line immediately postoperatively and then measured radial shortening after six to eight weeks using the change in ulnar variance.RESULTS Multivariate linear regression analysis showed that there was a significant linear association between the distance of the screws from the joint line and radial shortening. No other patient, injury, or treatment-related characteristic significantly influenced radial shortening in multivariate analysis.CONCLUSION Distal locking screws should be placed as close as possible to the subchondral joint line to prevent postoperative loss of reduction.展开更多
The locking compression plates (LCP) are efficient tools in open reduction and internal fixation (ORIF), especially in osteoporotic bones. Two important factors of screw density and screw position can affect the funct...The locking compression plates (LCP) are efficient tools in open reduction and internal fixation (ORIF), especially in osteoporotic bones. Two important factors of screw density and screw position can affect the functionality of the bone plate. Several studies have assessed the influence of the screw configurations on the bone-plate stiffness, but the effects of screw positions on the interfragmentary strain, εIF of LCP construct have not been investigated yet. In this study, finite element method was used to investigate the influence of screws number and position on the interfragmentary strain of LCP-femur system for a mid-shaft fracture. Results of this study showed that by insertion of screws closer to the fracture site, εIF decreases by 2nd degree polynomial function versus screw position, but by adding the screws from the ends of the plate, or by moving and placing the screws towards the fracture site, the reduction of εIF will be linear. Results of this study were compared and are in agreement with some studies in the literature, even though their scope was mostly stability of the bone-implant system, whereas our scope was focused on the interfragmentary strain.展开更多
目的:颈前路减压融合术是治疗退行性颈椎病的经典手术方式,钉板的使用增加了融合率及稳定性的同时,间接导致了邻近椎体退变和术后吞咽困难的发生。文章通过Meta分析方法比较ROI-C^(TM)自锁系统和传统融合器联合钉板内固定治疗退行性颈...目的:颈前路减压融合术是治疗退行性颈椎病的经典手术方式,钉板的使用增加了融合率及稳定性的同时,间接导致了邻近椎体退变和术后吞咽困难的发生。文章通过Meta分析方法比较ROI-C^(TM)自锁系统和传统融合器联合钉板内固定治疗退行性颈椎病患者的临床结果和并发症情况,为颈前路减压融合术中内固定方式的选择提供循证学支持。方法:检索中国知网、万方、维普、PubMed、Cochrane Library、Web of Science和Embase数据库,检索关于颈前路减压融合术中应用ROI-C^(TM)自锁系统与融合器联合钉板内固定治疗退行性颈椎病的中英文文献。检索时间范围为各数据库建库至2023年7月。由2名研究者严格按照纳入与排除标准选择文献,采用Cochrane偏倚风险工具对随机对照试验进行质量评价,NOS量表对队列研究进行质量评价。采用RevMan 5.4软件进行Meta分析。结局指标包括手术时间、术中出血量、日本骨科协会(Japanese Orthopaedic Association Scores,JOA)评分、颈椎功能障碍指数、C_(2)-C_(7)Cobb角、融合率、邻近椎体退变发生率、融合器沉降率和吞咽困难发生率。结果:共纳入13项研究,其中回顾性队列研究11项,随机对照试验2项,共1136例患者,ROI-C组569例,融合器联合钉板组567例。Meta分析结果显示:ROI-C组与融合器联合钉板组在手术时间(MD=-15.52,95%CI:-18.62至-12.42,P<0.00001),术中出血量(MD=-24.53,95%CI:-32.46至-16.61,P<0.00001),术后邻近节段退变率(RR=0.40,95%CI:0.27-0.60,P<0.00001)和术后总吞咽困难发生率(RR=0.18,95%CI:0.13-0.26,P<0.00001)均具有显著性差异。两者在术后JOA评分、颈椎功能障碍指数、C_(2)-C_(7)Cobb角、融合率和融合器沉降率方面无显著性差异(P≥0.05)。结论:在颈椎前路减压融合术中应用ROI-C^(TM)自锁系统与传统融合器联合钉板内固定治疗退行性颈椎病均可达到满意的临床效果,ROI-C^(TM)自锁系统操作更加简单,相比融合器联合钉板内固定能明显减少手术时间及术中出血量,在减少术后吞咽困难及邻近节段退变发生率等方面具有明显优势,对于跳跃型颈椎病及邻椎病翻修患者,更加推荐使用ROI-C^(TM)自锁系统。但鉴于其可能存在较高的沉降率,对于多节段且合并融合器沉降高危因素如骨质疏松、椎体终板破损的退行性颈椎病患者,仍建议使用融合器联合钉板内固定。展开更多
Background: There are at least 5 very popular methods described for the correction of mild to moderate hallux valgus deformities. Despite of reported and self experienced good results in favorable fitting preoperative...Background: There are at least 5 very popular methods described for the correction of mild to moderate hallux valgus deformities. Despite of reported and self experienced good results in favorable fitting preoperative anatomical conditions of some of these methods;it seems that no one is really satisfying under “difficult” or non favorable preoperative anatomic conditions. How could an optimum operation method for a satisfying correction of a mild to moderate hallux valgus look like? The well known criteria for an optimally satisfying method to achieve full normalization of important forefoot parameters under all conditions should be a lateralization, plantarization and derotation of the Ist metatarsal head and also a normalization of the distal metatarsal articular angle (DMAA) in combination with a soft tissue correction. Methods: In order to achieve this outcome without the disadvantages of shortening or the need for unloading, we developed a new operation technique and new fixation devices. We performed a simple transverse lazy-L subcapital osteotomy and after an additional soft tissue release the Ist metatarsal head was restored to its preplaned optimum position in terms of narrowing the IM angle, plantarization, correction of the hallux valgus angle, derotation of a pronation l malrotation and improvement of the DMAA. Fixation was achieved with an intramedullary angel-stable transfixed 30 mm titanium plate. The rigidity of the implant rendered interfragmental compression or solid bone contact unnecessary. The goal was only an optimal correction. All patients were allowed to ambulate with full weightbearing immediately after the operation. Results: We retrospectively reviewed 346 patients (433 feet) who underwent subcapital osteotomy between May 2007 and December 2011;308 were women and 38 men;their mean age was 65 years. The follow-up investigation was performed on average after 6.5 years (78 months);range 5.5 to 10 years (66 to 120 months). The AOFAS Score improved from 61.18 to 96.82 (t = 55.13, p ° to 4.21° (t = 89.70, p ° to 7.75° (t = 51.68, p ° to 6.61° (t = 29.34, p < 0.001). Minimal shortening of the first metatarsal (0.33 mm) and no recurrence of the deformity was observed. Conclusion: A new access to hallux valgus surgery is presented. Our results show that interfragmental compression between the osteotomy partners or good interfragmental contact is not necessary when a rigid intramedullary fixation device is used. The goal of this approach to hallux valgus surgery was to achieve excellent correction and a very rigid intramedullary angle-stable locked implant. The procedure yielded excellent results and was associated with no recurrence of hallux valgus.展开更多
文摘Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experiment was performed in torsion, compression, and bending tests with four different screw configurations: (I) one medial-to-lateral and one oblique, (II) two me-dial-to-lateral, (III) one medial-to-lateral and one anterior-to-posterior, and (IV) one medial-to-lateral, one anterior-to-posterior and one oblique in simu-lated distal metaphyseal fracture tibiae. Twenty- four Synthes EXPERT tibial IM nails were used for six specimens of each screw configuration. Parts I and II, tibial IM nails were locked with 5.0 mm in-terlocking screws into simulated distal tibiae (PVC and composite analogue tibia). Part III, the two most stable configurations were tested using five pairs of simulated cadaveric distal tibiae metaphy-seal fractures. Results: Significant differences were attributable to distal screw orientation for intrame- dullary nailing of distal tibia fractures. Configura-tions II and IV were found to be more stable than the other two configurations. No significant differ-ence was detected in construct stability in all modes of testing between Configurations II and IV. Dis-cussion: Configuration I did not provide superior stability for the distal tibia fracture fixation. Con-figurations II and IV provided equivalent stability. When choosing IM fixation for treatment of distal tibia metaphyseal fractures two medial-to-lateral screws provide the necessary stability for satisfac-tory fixation. Clinical Relevance: This study indi-cated an option for operative treatment of distal metaphyseal tibia fracture fixation where preserva-tion of soft tissue and rigid stabilization are needed.
文摘AIM To determine factors correlated with postoperative radial shortening in patients with distal radius fractures treated with volar locking distal radius plates.METHODS A total of 250 patients with a distal radius fracture stabilised with volar locking plates between January 2010 and December 2014 were included in a multicentre retrospective cohort study. We measured the distance of the distal locking screws to the joint line immediately postoperatively and then measured radial shortening after six to eight weeks using the change in ulnar variance.RESULTS Multivariate linear regression analysis showed that there was a significant linear association between the distance of the screws from the joint line and radial shortening. No other patient, injury, or treatment-related characteristic significantly influenced radial shortening in multivariate analysis.CONCLUSION Distal locking screws should be placed as close as possible to the subchondral joint line to prevent postoperative loss of reduction.
文摘The locking compression plates (LCP) are efficient tools in open reduction and internal fixation (ORIF), especially in osteoporotic bones. Two important factors of screw density and screw position can affect the functionality of the bone plate. Several studies have assessed the influence of the screw configurations on the bone-plate stiffness, but the effects of screw positions on the interfragmentary strain, εIF of LCP construct have not been investigated yet. In this study, finite element method was used to investigate the influence of screws number and position on the interfragmentary strain of LCP-femur system for a mid-shaft fracture. Results of this study showed that by insertion of screws closer to the fracture site, εIF decreases by 2nd degree polynomial function versus screw position, but by adding the screws from the ends of the plate, or by moving and placing the screws towards the fracture site, the reduction of εIF will be linear. Results of this study were compared and are in agreement with some studies in the literature, even though their scope was mostly stability of the bone-implant system, whereas our scope was focused on the interfragmentary strain.
文摘目的:颈前路减压融合术是治疗退行性颈椎病的经典手术方式,钉板的使用增加了融合率及稳定性的同时,间接导致了邻近椎体退变和术后吞咽困难的发生。文章通过Meta分析方法比较ROI-C^(TM)自锁系统和传统融合器联合钉板内固定治疗退行性颈椎病患者的临床结果和并发症情况,为颈前路减压融合术中内固定方式的选择提供循证学支持。方法:检索中国知网、万方、维普、PubMed、Cochrane Library、Web of Science和Embase数据库,检索关于颈前路减压融合术中应用ROI-C^(TM)自锁系统与融合器联合钉板内固定治疗退行性颈椎病的中英文文献。检索时间范围为各数据库建库至2023年7月。由2名研究者严格按照纳入与排除标准选择文献,采用Cochrane偏倚风险工具对随机对照试验进行质量评价,NOS量表对队列研究进行质量评价。采用RevMan 5.4软件进行Meta分析。结局指标包括手术时间、术中出血量、日本骨科协会(Japanese Orthopaedic Association Scores,JOA)评分、颈椎功能障碍指数、C_(2)-C_(7)Cobb角、融合率、邻近椎体退变发生率、融合器沉降率和吞咽困难发生率。结果:共纳入13项研究,其中回顾性队列研究11项,随机对照试验2项,共1136例患者,ROI-C组569例,融合器联合钉板组567例。Meta分析结果显示:ROI-C组与融合器联合钉板组在手术时间(MD=-15.52,95%CI:-18.62至-12.42,P<0.00001),术中出血量(MD=-24.53,95%CI:-32.46至-16.61,P<0.00001),术后邻近节段退变率(RR=0.40,95%CI:0.27-0.60,P<0.00001)和术后总吞咽困难发生率(RR=0.18,95%CI:0.13-0.26,P<0.00001)均具有显著性差异。两者在术后JOA评分、颈椎功能障碍指数、C_(2)-C_(7)Cobb角、融合率和融合器沉降率方面无显著性差异(P≥0.05)。结论:在颈椎前路减压融合术中应用ROI-C^(TM)自锁系统与传统融合器联合钉板内固定治疗退行性颈椎病均可达到满意的临床效果,ROI-C^(TM)自锁系统操作更加简单,相比融合器联合钉板内固定能明显减少手术时间及术中出血量,在减少术后吞咽困难及邻近节段退变发生率等方面具有明显优势,对于跳跃型颈椎病及邻椎病翻修患者,更加推荐使用ROI-C^(TM)自锁系统。但鉴于其可能存在较高的沉降率,对于多节段且合并融合器沉降高危因素如骨质疏松、椎体终板破损的退行性颈椎病患者,仍建议使用融合器联合钉板内固定。
文摘Background: There are at least 5 very popular methods described for the correction of mild to moderate hallux valgus deformities. Despite of reported and self experienced good results in favorable fitting preoperative anatomical conditions of some of these methods;it seems that no one is really satisfying under “difficult” or non favorable preoperative anatomic conditions. How could an optimum operation method for a satisfying correction of a mild to moderate hallux valgus look like? The well known criteria for an optimally satisfying method to achieve full normalization of important forefoot parameters under all conditions should be a lateralization, plantarization and derotation of the Ist metatarsal head and also a normalization of the distal metatarsal articular angle (DMAA) in combination with a soft tissue correction. Methods: In order to achieve this outcome without the disadvantages of shortening or the need for unloading, we developed a new operation technique and new fixation devices. We performed a simple transverse lazy-L subcapital osteotomy and after an additional soft tissue release the Ist metatarsal head was restored to its preplaned optimum position in terms of narrowing the IM angle, plantarization, correction of the hallux valgus angle, derotation of a pronation l malrotation and improvement of the DMAA. Fixation was achieved with an intramedullary angel-stable transfixed 30 mm titanium plate. The rigidity of the implant rendered interfragmental compression or solid bone contact unnecessary. The goal was only an optimal correction. All patients were allowed to ambulate with full weightbearing immediately after the operation. Results: We retrospectively reviewed 346 patients (433 feet) who underwent subcapital osteotomy between May 2007 and December 2011;308 were women and 38 men;their mean age was 65 years. The follow-up investigation was performed on average after 6.5 years (78 months);range 5.5 to 10 years (66 to 120 months). The AOFAS Score improved from 61.18 to 96.82 (t = 55.13, p ° to 4.21° (t = 89.70, p ° to 7.75° (t = 51.68, p ° to 6.61° (t = 29.34, p < 0.001). Minimal shortening of the first metatarsal (0.33 mm) and no recurrence of the deformity was observed. Conclusion: A new access to hallux valgus surgery is presented. Our results show that interfragmental compression between the osteotomy partners or good interfragmental contact is not necessary when a rigid intramedullary fixation device is used. The goal of this approach to hallux valgus surgery was to achieve excellent correction and a very rigid intramedullary angle-stable locked implant. The procedure yielded excellent results and was associated with no recurrence of hallux valgus.