In the novel prototype of micro-gyroscope structure,the new configured capacitance sensing scheme for the micro gyroscope was analyzed and the virtual instrument based detection scheme was implemented.The digital lock...In the novel prototype of micro-gyroscope structure,the new configured capacitance sensing scheme for the micro gyroscope was analyzed and the virtual instrument based detection scheme was implemented.The digital lock-in amplifier was employed in the capacitance detection to restrain the noise interference.The capacitance analysis shows that 1 fF capacitance variation corresponds to 0.1 degree of the turn angle.The differential capacitance bridge and the charge integral amplifier were used as the front signal input interface.In the implementation of digital lock-in amplifier,a new routine which warranted the exactly matching of the reference phase to signal phase was proposed.The result of the experiment shows that digital lock-in amplifier can greatly eliminate the noise in the output signal.The non linearity of the turn angle output is 2.3% and the minimum resolution of turn angle is 0.04 degrees.The application of the software demodulation in the signal detection of micro-electro-mechanical-system(MEMS)device is a new attempt,and it shows the prospective for a high-performance application.展开更多
Lock-in amplifiers are used to detect and measure very small alternating current(AC)signals down to the range of nVs.Accurate measurements can be made even when the small signals are buried by noise thousands of times...Lock-in amplifiers are used to detect and measure very small alternating current(AC)signals down to the range of nVs.Accurate measurements can be made even when the small signals are buried by noise thousands of times larger.With the digital signal processing(DSP)technology involved in modern instrumentation,a lock-in amplifier is more versatile in sensing and recovering small signals.Combining the virtual instrumentation technology,we reorganize the functional blocks of a programmable lock-in amplifier and build it as a virtual spectrum analyzer,virtual impedance meter,virtual network analyzer,virtual semiconductor parameter analyzer,signal generator,etc.A 4 layer model is used to implement these virtual instruments.The same virtual instrument can also be implemented on a general purpose FPGA developing board.展开更多
A method of implementing high cost-effective and highly integrated digital lock-in amplifier with microcontroller is discussed. And the digital lock-in amplifier is more suitable for meastwing lowfrequency weak signal...A method of implementing high cost-effective and highly integrated digital lock-in amplifier with microcontroller is discussed. And the digital lock-in amplifier is more suitable for meastwing lowfrequency weak signal. Digital signal sequence is obtained through sampling signal measured over an integer number of signal periods, but digital reference sequence is acquired through mathematical operation, then digital phase sensitive detection can be implemented by calculating the cross-correlation function of digital signal sequence and digital reference sequence. In addition, the frequency response and phase character of the digital lock-in amplifier is analyzed. Finally, the designed digital lock-in amplifier is achieved. Expermental results show that the digital lock-in amplifier can be used for measuring weak signal with low ignal-to-noise ratio.展开更多
Introducing a System-on-Chip (SoC) microcontroller (C8051F350) into a ceramic pressure sensor has resulted in the design of a intelligent sensor. An improved algorithm for digital phassensitive detection is used ...Introducing a System-on-Chip (SoC) microcontroller (C8051F350) into a ceramic pressure sensor has resulted in the design of a intelligent sensor. An improved algorithm for digital phassensitive detection is used to perform lock-in amplification of the sensor signal. The compensation for the sensor error is realized by the detection of the sensor's supply voltage and working temperature. The system also has the function of short/open circuit fault detection and can ommamicate with other digital equipment through an RS-485 communication interface. In the design, full utilization of the SoC microcontroller' s internal resource results in the simple hardware structure. Experimental results show that the error of the sensor is less than 0.5% at range ratio 1 : 10. Employing the microcontroller and using lock-in amplification algorithm are an effective method for achieving an intelligent sensor of slowly-varying physical quantities, thereby improving the measuring accuracy and performance.展开更多
A portable analog lock-in amplifier capable of accurate phase detection is proposed in this paper. The proposed lock-in amplifier, which uses the dual-channel orthometric signals as the references to build the xy coor...A portable analog lock-in amplifier capable of accurate phase detection is proposed in this paper. The proposed lock-in amplifier, which uses the dual-channel orthometric signals as the references to build the xy coordinate system, can detect the relative phase between the input and x-axis based on trigonometric function. The sensitivity of the phase measurement reaches 0.014degree, and a detection precision of 0.1 degree is achieved. At the same time, the performance of the lock-in amplifier is verified in the high precision optical oxygen concentration detection. Experimental results reveal that the portable analog lock-in amplifier is accurate for phase detection applications. In the oxygen sensing experiments, 0.058% oxygen concentration resulted in 0.1 degree phase shift detected by the lock-in amplifier precisely. In addition, the lock-in amplifier is small and economical compared with the commercial lock-in equipments, so it can be easily integrated in many portable devices for industrial applications.展开更多
In view of the low resolution and accuracy of traditional magnetometer,a method of microwave frequency modulation technology based on nitrogen-vacancy(NV)center in diamond for magnetic detection was proposed.The magne...In view of the low resolution and accuracy of traditional magnetometer,a method of microwave frequency modulation technology based on nitrogen-vacancy(NV)center in diamond for magnetic detection was proposed.The magnetometer studied can reduce the frequency noise of system and improve the magnetic sensitivity by microwave frequency modulation.Firstly,ESR spectra by sweeping the microwave frequency was obtained.Further,the microwave frequency modulated was gained through the mixed high-frequency sinusoidal modulation signal generated by signal generator.In addition,the frequency through the lock-in amplifier was locked,and the signal which was proportional to the first derivative of the spectrum was obtained.The experimental results show that the sensitivity of magnetic field detection can reach 17.628 nT/Hz based on microwave frequency modulation technology.The method realizes high resolution and sensitivity for magnetic field detection.展开更多
A kind of signal acquisition circuit and the related signal processing method of the capacitanceelectromagnetic flowmeter (EMF) were introduced. The circuit can eliminate the influence of distributed capacitanceon the...A kind of signal acquisition circuit and the related signal processing method of the capacitanceelectromagnetic flowmeter (EMF) were introduced. The circuit can eliminate the influence of distributed capacitanceon the input impedance of the operational amplifier, and greatly improve the input impedance of the detection circuitto overcome the disadvantage of high signal source impedance. The rotating capacitor filter is a signal processingmethod based on the phase-sensitive detection technology. It can extract the weak signal from the strong and widebandbackground noise, so it is very suitable for the processing of capacitive electromagnetic flow signals. Throughthe comparison of the signal amplitude obtained at different flow rates and the comparison of signal spectrumcomponents before and after the filter, the effectiveness of the bootstrap signal acquisition circuit and rotatingcapacitor filtering method is verified.展开更多
Aiming at the major failure mode of prestressed concrete cylinder pipes (PCCP),namely the fracture of prestressed steel wires,the broken wire detection technology based on orthogonal electromagnetic principle is studi...Aiming at the major failure mode of prestressed concrete cylinder pipes (PCCP),namely the fracture of prestressed steel wires,the broken wire detection technology based on orthogonal electromagnetic principle is studied. The detection system model is established and optimized by using COMSOL finite element simulation software. Furthermore,the theoretical analysis of the wire-breaking effect is carried out. The influence of factors on broken wire signal characteristics such as edge effect,circumferential relative position of the detector and broken wires,excitation frequency and relative permeability of steel wires is analyzed,which provides a theoretical guidance for the field detection. The influence of the steel cylinder structure on the simulation results is analyzed,which provides a reference for the improvement of calculation efficiency. The corresponding detection system is designed and implemented. Concretely,a high-voltage and high-power sinusoidal signal coil drive scheme based on sinusoidal pulse width modulation technology and an intelligent power module is innovatively proposed and the corresponding protection circuit is designed. The broken wire signal could be effectively extracted through a lock-in amplifier. The experimental results show that this system can effectively identify the broken wires with low cost.展开更多
Since the gas infrared absorption spectrum source intensity of several in a thousand, it is even less linewidth is only several nanometers occupying the than the noise of light source. The signal of gas absorption is ...Since the gas infrared absorption spectrum source intensity of several in a thousand, it is even less linewidth is only several nanometers occupying the than the noise of light source. The signal of gas absorption is submerged in the noise, so it is impossible to measure the concentration of gas with spectrum absorption directly. According to the principle and parameters of difference absorption system of CH4 gas, a detection circuit consisted of the lock-in amplifier is designed. The experiment results indicated that the detection circuit can satisfy the demand of the whole system, and the limit concentration is 150×10^-6.展开更多
A fully automated atomic force microscope(AFM)is presented.The mechanical motion of the AFM stage was controlled by three steppers.The fine motion of the AFM was controlled by an MCL one-axis piezo plate.A32.768kHz cr...A fully automated atomic force microscope(AFM)is presented.The mechanical motion of the AFM stage was controlled by three steppers.The fine motion of the AFM was controlled by an MCL one-axis piezo plate.A32.768kHz crystal tuning fork(TF)was used as the transducer with a probe attached.An acoustic sensor was used to measure the interactions between the probe and the sample.An SR850lock-in amplifier was used to monitor the TF signals.An additional lock-in amplifier was used to monitor the acoustic signal.A field programmable gate array(FPGA)board was used to collect the data in automatic mode.The main controller was coded with LabVIEW,which was in charge of Z-axis scan,signal processing and data visualization.A manual mode and an automatic mode were implemented in the controller.Users can switch the two modes at any time during the operation.This AFM system showed several advantages during the test operations.It is simple,flexible and easy to use.展开更多
In order to overcome the deficiencies of traditional pressure sensors, a kind of intelligent pressure sensors with temperature correction is designed. Qccording to the intelligent sensor system of composition and rang...In order to overcome the deficiencies of traditional pressure sensors, a kind of intelligent pressure sensors with temperature correction is designed. Qccording to the intelligent sensor system of composition and range of applications, with fully taking into account the parameters of the connection between of co-ordination, we chose a good usability, high reliability and low cost components composed of the entire measurement system, with controlling and dealing with in 80C51 miller, the system had the temperature and pressure parameters with automatic measurement, amplification, A/D conversion, the weak signal locked amplification, as well as PhaseSensitive Detection (PSD), common-mode signal rejection, the collected signal de-noising processing, cross-sensitivity of the decoupling and show the results. It also has a self-test, automatic temperature condition and on, site communications and other functions.展开更多
基金The National Natural Science Foundation ofChina(No.60402003)The National High Technology Research and Development Pro-gram of China(863Program)(No.2002AA745120)
文摘In the novel prototype of micro-gyroscope structure,the new configured capacitance sensing scheme for the micro gyroscope was analyzed and the virtual instrument based detection scheme was implemented.The digital lock-in amplifier was employed in the capacitance detection to restrain the noise interference.The capacitance analysis shows that 1 fF capacitance variation corresponds to 0.1 degree of the turn angle.The differential capacitance bridge and the charge integral amplifier were used as the front signal input interface.In the implementation of digital lock-in amplifier,a new routine which warranted the exactly matching of the reference phase to signal phase was proposed.The result of the experiment shows that digital lock-in amplifier can greatly eliminate the noise in the output signal.The non linearity of the turn angle output is 2.3% and the minimum resolution of turn angle is 0.04 degrees.The application of the software demodulation in the signal detection of micro-electro-mechanical-system(MEMS)device is a new attempt,and it shows the prospective for a high-performance application.
文摘Lock-in amplifiers are used to detect and measure very small alternating current(AC)signals down to the range of nVs.Accurate measurements can be made even when the small signals are buried by noise thousands of times larger.With the digital signal processing(DSP)technology involved in modern instrumentation,a lock-in amplifier is more versatile in sensing and recovering small signals.Combining the virtual instrumentation technology,we reorganize the functional blocks of a programmable lock-in amplifier and build it as a virtual spectrum analyzer,virtual impedance meter,virtual network analyzer,virtual semiconductor parameter analyzer,signal generator,etc.A 4 layer model is used to implement these virtual instruments.The same virtual instrument can also be implemented on a general purpose FPGA developing board.
文摘A method of implementing high cost-effective and highly integrated digital lock-in amplifier with microcontroller is discussed. And the digital lock-in amplifier is more suitable for meastwing lowfrequency weak signal. Digital signal sequence is obtained through sampling signal measured over an integer number of signal periods, but digital reference sequence is acquired through mathematical operation, then digital phase sensitive detection can be implemented by calculating the cross-correlation function of digital signal sequence and digital reference sequence. In addition, the frequency response and phase character of the digital lock-in amplifier is analyzed. Finally, the designed digital lock-in amplifier is achieved. Expermental results show that the digital lock-in amplifier can be used for measuring weak signal with low ignal-to-noise ratio.
基金supported by Research Project of "SUSTSpring Bud"(No.2008BWZ042)from Shandong University of Science and Technology
文摘Introducing a System-on-Chip (SoC) microcontroller (C8051F350) into a ceramic pressure sensor has resulted in the design of a intelligent sensor. An improved algorithm for digital phassensitive detection is used to perform lock-in amplification of the sensor signal. The compensation for the sensor error is realized by the detection of the sensor's supply voltage and working temperature. The system also has the function of short/open circuit fault detection and can ommamicate with other digital equipment through an RS-485 communication interface. In the design, full utilization of the SoC microcontroller' s internal resource results in the simple hardware structure. Experimental results show that the error of the sensor is less than 0.5% at range ratio 1 : 10. Employing the microcontroller and using lock-in amplification algorithm are an effective method for achieving an intelligent sensor of slowly-varying physical quantities, thereby improving the measuring accuracy and performance.
文摘A portable analog lock-in amplifier capable of accurate phase detection is proposed in this paper. The proposed lock-in amplifier, which uses the dual-channel orthometric signals as the references to build the xy coordinate system, can detect the relative phase between the input and x-axis based on trigonometric function. The sensitivity of the phase measurement reaches 0.014degree, and a detection precision of 0.1 degree is achieved. At the same time, the performance of the lock-in amplifier is verified in the high precision optical oxygen concentration detection. Experimental results reveal that the portable analog lock-in amplifier is accurate for phase detection applications. In the oxygen sensing experiments, 0.058% oxygen concentration resulted in 0.1 degree phase shift detected by the lock-in amplifier precisely. In addition, the lock-in amplifier is small and economical compared with the commercial lock-in equipments, so it can be easily integrated in many portable devices for industrial applications.
基金National Natural Science Foundation of China(Nos.51635011,61503346,51727808)National Science Foundation of Shanxi Province(No.201701D121080)
文摘In view of the low resolution and accuracy of traditional magnetometer,a method of microwave frequency modulation technology based on nitrogen-vacancy(NV)center in diamond for magnetic detection was proposed.The magnetometer studied can reduce the frequency noise of system and improve the magnetic sensitivity by microwave frequency modulation.Firstly,ESR spectra by sweeping the microwave frequency was obtained.Further,the microwave frequency modulated was gained through the mixed high-frequency sinusoidal modulation signal generated by signal generator.In addition,the frequency through the lock-in amplifier was locked,and the signal which was proportional to the first derivative of the spectrum was obtained.The experimental results show that the sensitivity of magnetic field detection can reach 17.628 nT/Hz based on microwave frequency modulation technology.The method realizes high resolution and sensitivity for magnetic field detection.
文摘A kind of signal acquisition circuit and the related signal processing method of the capacitanceelectromagnetic flowmeter (EMF) were introduced. The circuit can eliminate the influence of distributed capacitanceon the input impedance of the operational amplifier, and greatly improve the input impedance of the detection circuitto overcome the disadvantage of high signal source impedance. The rotating capacitor filter is a signal processingmethod based on the phase-sensitive detection technology. It can extract the weak signal from the strong and widebandbackground noise, so it is very suitable for the processing of capacitive electromagnetic flow signals. Throughthe comparison of the signal amplitude obtained at different flow rates and the comparison of signal spectrumcomponents before and after the filter, the effectiveness of the bootstrap signal acquisition circuit and rotatingcapacitor filtering method is verified.
基金National Natural Science Foundation of China(No.61304244)
文摘Aiming at the major failure mode of prestressed concrete cylinder pipes (PCCP),namely the fracture of prestressed steel wires,the broken wire detection technology based on orthogonal electromagnetic principle is studied. The detection system model is established and optimized by using COMSOL finite element simulation software. Furthermore,the theoretical analysis of the wire-breaking effect is carried out. The influence of factors on broken wire signal characteristics such as edge effect,circumferential relative position of the detector and broken wires,excitation frequency and relative permeability of steel wires is analyzed,which provides a theoretical guidance for the field detection. The influence of the steel cylinder structure on the simulation results is analyzed,which provides a reference for the improvement of calculation efficiency. The corresponding detection system is designed and implemented. Concretely,a high-voltage and high-power sinusoidal signal coil drive scheme based on sinusoidal pulse width modulation technology and an intelligent power module is innovatively proposed and the corresponding protection circuit is designed. The broken wire signal could be effectively extracted through a lock-in amplifier. The experimental results show that this system can effectively identify the broken wires with low cost.
基金Doctorate Foundation of Hebei Province(03547020D) Natural Science Foundation of Heilongjiang Province(F0312)
文摘Since the gas infrared absorption spectrum source intensity of several in a thousand, it is even less linewidth is only several nanometers occupying the than the noise of light source. The signal of gas absorption is submerged in the noise, so it is impossible to measure the concentration of gas with spectrum absorption directly. According to the principle and parameters of difference absorption system of CH4 gas, a detection circuit consisted of the lock-in amplifier is designed. The experiment results indicated that the detection circuit can satisfy the demand of the whole system, and the limit concentration is 150×10^-6.
文摘A fully automated atomic force microscope(AFM)is presented.The mechanical motion of the AFM stage was controlled by three steppers.The fine motion of the AFM was controlled by an MCL one-axis piezo plate.A32.768kHz crystal tuning fork(TF)was used as the transducer with a probe attached.An acoustic sensor was used to measure the interactions between the probe and the sample.An SR850lock-in amplifier was used to monitor the TF signals.An additional lock-in amplifier was used to monitor the acoustic signal.A field programmable gate array(FPGA)board was used to collect the data in automatic mode.The main controller was coded with LabVIEW,which was in charge of Z-axis scan,signal processing and data visualization.A manual mode and an automatic mode were implemented in the controller.Users can switch the two modes at any time during the operation.This AFM system showed several advantages during the test operations.It is simple,flexible and easy to use.
文摘In order to overcome the deficiencies of traditional pressure sensors, a kind of intelligent pressure sensors with temperature correction is designed. Qccording to the intelligent sensor system of composition and range of applications, with fully taking into account the parameters of the connection between of co-ordination, we chose a good usability, high reliability and low cost components composed of the entire measurement system, with controlling and dealing with in 80C51 miller, the system had the temperature and pressure parameters with automatic measurement, amplification, A/D conversion, the weak signal locked amplification, as well as PhaseSensitive Detection (PSD), common-mode signal rejection, the collected signal de-noising processing, cross-sensitivity of the decoupling and show the results. It also has a self-test, automatic temperature condition and on, site communications and other functions.