For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention....For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention. In this study, a water hammer protection scheme combined with an overflow surge tank and a regulating valve was developed. A mathematical model of the overflow surge tank was developed, and an analytical formula for the height of the overflow surge tank was derived. Furthermore, a practical water supply project was used to evaluate the feasibility of the combined protection scheme and analyze the sensitivity of valve regulation rules. The results showed that the combined protection scheme effectively reduced the height of the surge tank, lessened the difficulties related to construction, and reduced the necessary financial investment for the project. The two-stage closing rule articulated as fast first and then slow could minimize the overflow volume of the surge tank when the power failure occurred, while the two-stage opening rule articulated as slow first and then fast could be more conducive to the safety of the water supply system when the pump started up.展开更多
The extensively built long-distance water transmission pipelines have become the main water sources for urban areas. To ensure the reliability and safety of the water supply, from the viewpoint of overall management, ...The extensively built long-distance water transmission pipelines have become the main water sources for urban areas. To ensure the reliability and safety of the water supply, from the viewpoint of overall management, it would be necessary to establish a system of information management for the pipeline. The monitoring, calculating and analyzing functions of the system serve to give controlling instructions and safe operating rules to the automatic equipment and technician, making sure the resistance coefficient distribution along the pipeline is reasonable; the hydraulic state transition is smooth when operating conditions change or water supply accidents occur, avoiding the damage of water hammer. This paper covered the composition structures of the information management system of long-distance water transmission pipelines and the functions of the subsystems, and finally elaborated on the approaches and steps of building a mathematics model for the analysis of dynamic hydraulic status.展开更多
A novel d!sphase supplying supported liquid membrane (DSSLM), containing supplying feed phase andsupplying stripping phase tor transport behavior ot NI(Ⅱ), have been studied. The supplying supported feed phase in...A novel d!sphase supplying supported liquid membrane (DSSLM), containing supplying feed phase andsupplying stripping phase tor transport behavior ot NI(Ⅱ), have been studied. The supplying supported feed phase included feed solution and di(2-ethyhexyl) phosphoric acid (HDEHP) as the carrier in kerosene, and supplying stripping phase included HDEHP as the cartier in kerosene and HC1 as the stripping agent. The effects of volume ratio of membrane solution to feed solution (O/F), pH, initial concentration of Ni(Ⅱ) and ionic strength in the feedsolution, volume ratio of membrane solution to stripping solution (O/S), concentration of H2SO4 solution, HDEHP concentration in the supplying stripping phase on transport of Ni(/I), the advantages of DSSLM compared to the traditional supported liquid membrane (SLM), the system stability, the reuse of membrane solution and the reten- tion of membrane phase were studied. Experimental results indicated that the optimum transpgrt of Ni(Ⅱ) was oh-tained when H2SO4 concentration was 2.00 mol'L-', HDEHP concentration was 0.120 mol·L-1, and O/S was 4· 1 in the supplying stripping phase, O/F was 1 : 10 and pH was 5.20 in the supplying feed phase. The ionic strength in supplying feed phase had no obvious effect on transport of Ni(Ⅱ). When initial Ni(Ⅱ) concentration was 2.00x 10-4 mol/L, the transport percentage of Ni(Ⅱ) was up to 93.1% in 250 min. The kinetic equation was deduced in terms of the law of mass diffusion and the interface chemistry.展开更多
基金supported by the National Natural Science Foundation of China(Grants No.52179062 and 51879087).
文摘For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention. In this study, a water hammer protection scheme combined with an overflow surge tank and a regulating valve was developed. A mathematical model of the overflow surge tank was developed, and an analytical formula for the height of the overflow surge tank was derived. Furthermore, a practical water supply project was used to evaluate the feasibility of the combined protection scheme and analyze the sensitivity of valve regulation rules. The results showed that the combined protection scheme effectively reduced the height of the surge tank, lessened the difficulties related to construction, and reduced the necessary financial investment for the project. The two-stage closing rule articulated as fast first and then slow could minimize the overflow volume of the surge tank when the power failure occurred, while the two-stage opening rule articulated as slow first and then fast could be more conducive to the safety of the water supply system when the pump started up.
基金Hi-Tech Research and Development Program of China (863 Program)(2002AA601140)
文摘The extensively built long-distance water transmission pipelines have become the main water sources for urban areas. To ensure the reliability and safety of the water supply, from the viewpoint of overall management, it would be necessary to establish a system of information management for the pipeline. The monitoring, calculating and analyzing functions of the system serve to give controlling instructions and safe operating rules to the automatic equipment and technician, making sure the resistance coefficient distribution along the pipeline is reasonable; the hydraulic state transition is smooth when operating conditions change or water supply accidents occur, avoiding the damage of water hammer. This paper covered the composition structures of the information management system of long-distance water transmission pipelines and the functions of the subsystems, and finally elaborated on the approaches and steps of building a mathematics model for the analysis of dynamic hydraulic status.
基金Supported by the Action Plan for the Development of Western China of the Chinese Academy of Sciences(KZCX2-XB2-13)the Knowledge Innovation Program of the Chinese Academy of Sciences(KSCX2-YW-N-003)Research Fund for Excellent Doctoral Thesis of Xi'an University of Tehcnology(602-210805 and 602-210804)
文摘A novel d!sphase supplying supported liquid membrane (DSSLM), containing supplying feed phase andsupplying stripping phase tor transport behavior ot NI(Ⅱ), have been studied. The supplying supported feed phase included feed solution and di(2-ethyhexyl) phosphoric acid (HDEHP) as the carrier in kerosene, and supplying stripping phase included HDEHP as the cartier in kerosene and HC1 as the stripping agent. The effects of volume ratio of membrane solution to feed solution (O/F), pH, initial concentration of Ni(Ⅱ) and ionic strength in the feedsolution, volume ratio of membrane solution to stripping solution (O/S), concentration of H2SO4 solution, HDEHP concentration in the supplying stripping phase on transport of Ni(/I), the advantages of DSSLM compared to the traditional supported liquid membrane (SLM), the system stability, the reuse of membrane solution and the reten- tion of membrane phase were studied. Experimental results indicated that the optimum transpgrt of Ni(Ⅱ) was oh-tained when H2SO4 concentration was 2.00 mol'L-', HDEHP concentration was 0.120 mol·L-1, and O/S was 4· 1 in the supplying stripping phase, O/F was 1 : 10 and pH was 5.20 in the supplying feed phase. The ionic strength in supplying feed phase had no obvious effect on transport of Ni(Ⅱ). When initial Ni(Ⅱ) concentration was 2.00x 10-4 mol/L, the transport percentage of Ni(Ⅱ) was up to 93.1% in 250 min. The kinetic equation was deduced in terms of the law of mass diffusion and the interface chemistry.