A rigid mode of long-span cantilevered roof was tested in wind tunnel. By analyzing the relation between wind angle and wind pressure coefficient and the relation between wind angle and wind shape factor, we found tha...A rigid mode of long-span cantilevered roof was tested in wind tunnel. By analyzing the relation between wind angle and wind pressure coefficient and the relation between wind angle and wind shape factor, we found that 90° is the most disadvantageous wind angle. Furthermore, the fluctuation of wind pressure at the windward edge was reflected by power spectrum density (PSD) and coherence function. The correlation coefficients of measuring points on outer and inner surfaces verifys that the largest lift force was produced at 90°.展开更多
Full-scale measurements are regarded as the most reliable method to evaluate wind effects on large buildings and structures. Some selected results are presented in this paper from the full-scale measurement of wind ef...Full-scale measurements are regarded as the most reliable method to evaluate wind effects on large buildings and structures. Some selected results are presented in this paper from the full-scale measurement of wind effects on a long-span steel roof structure during the passage of Typhoon Fanapi. Some fi eld data, including wind speed and direction, acceleration responses, etc., were continuously and simultaneously recorded during the passage of the typhoon. Comprehensive analysis of the measured data is conducted to evaluate the typhoon-generated wind characteristics and its effects on a long-span steel roof. The fi rst four natural frequencies and their vibration mode shapes of the Guangzhou International Sports Arena(GISA) roof are evaluated by the stochastic subspace identifi cation(SSI) method and comparisons with those from fi nite element(FE) analysis are made. Meanwhile, damping ratios of the roof are also identifi ed by the SSI method and compared with those identifi ed by the random decrement method; the amplitude-dependent damping behaviors are also discussed. The fullscale measurement results are further compared with the corresponding wind tunnel test results to evaluate its reliability. The results obtained from this study are valuable for academic and professional engineers involved in the design of large-span roof structures.展开更多
文摘A rigid mode of long-span cantilevered roof was tested in wind tunnel. By analyzing the relation between wind angle and wind pressure coefficient and the relation between wind angle and wind shape factor, we found that 90° is the most disadvantageous wind angle. Furthermore, the fluctuation of wind pressure at the windward edge was reflected by power spectrum density (PSD) and coherence function. The correlation coefficients of measuring points on outer and inner surfaces verifys that the largest lift force was produced at 90°.
基金National Natural Science Foundation of China under Grant Nos.51222801 and 51378134Yangcheng Scholarship in Guangzhou Municipal Universities under Project No.12A004Sthe Research Funding for Ph.D Programme in Higher Education Universities under Project No.20124410110005
文摘Full-scale measurements are regarded as the most reliable method to evaluate wind effects on large buildings and structures. Some selected results are presented in this paper from the full-scale measurement of wind effects on a long-span steel roof structure during the passage of Typhoon Fanapi. Some fi eld data, including wind speed and direction, acceleration responses, etc., were continuously and simultaneously recorded during the passage of the typhoon. Comprehensive analysis of the measured data is conducted to evaluate the typhoon-generated wind characteristics and its effects on a long-span steel roof. The fi rst four natural frequencies and their vibration mode shapes of the Guangzhou International Sports Arena(GISA) roof are evaluated by the stochastic subspace identifi cation(SSI) method and comparisons with those from fi nite element(FE) analysis are made. Meanwhile, damping ratios of the roof are also identifi ed by the SSI method and compared with those identifi ed by the random decrement method; the amplitude-dependent damping behaviors are also discussed. The fullscale measurement results are further compared with the corresponding wind tunnel test results to evaluate its reliability. The results obtained from this study are valuable for academic and professional engineers involved in the design of large-span roof structures.