期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Thiocyanate ion selective electrode based on bis(N-3-methylphenyl salicylidenaminato)copper(Ⅱ) ionophore
1
作者 A.Benvidi M.T.Ghanbarzadeh +2 位作者 M.Dehghan M.Mazloum-Ardakani R.Vafazadeh 《Chinese Chemical Letters》 SCIE CAS CSCD 2014年第12期1639-1642,共4页
In this work a PVC membrane electrode based on bis(N-3-methyl phenyl salicylidenaminato)copper(II)as ionophore was prepared.The electrode was tested by inorganic anions and showed good selectivity for thiocyanate ... In this work a PVC membrane electrode based on bis(N-3-methyl phenyl salicylidenaminato)copper(II)as ionophore was prepared.The electrode was tested by inorganic anions and showed good selectivity for thiocyanate ion.This sensor showed Nerstian behavior with a slope of a-59.3 mV per decade at 25℃.The proposed electrode exhibited a wide linear range from 1.0 × 10^-6 mol/L to 1.0× 10^-1 mol/L with a detection limit of 5.0×10^-7 mol/L.The electrode response was independent of pH in the range of 4.0-10.0.The response time is about 9-21s,and the electrode can be used for over 60 days without considerable deterioration.The prepared sensor was applied as an indicator electrode in potentiometric titration of SCN^- with Ag^+ ion and to determine the thiocyanate in samples of urine and saliva. 展开更多
关键词 Thiocyanate PVC membrane electrode Potentiometric determination lonophore
原文传递
A bismuth(Ⅲ) PVC membrane ion selective electrode based on5-(3,4,5-trimethoxyphenyl)-4-amino-1,2,4-triazole-3-thiol
2
作者 Hai-Xia Wang Zhen-Ning Yan +2 位作者 Xiang-Li Wen Yun-Xia Kang Shuang-Yan Zhang 《Chinese Chemical Letters》 SCIE CAS CSCD 2015年第9期1147-1149,共3页
The construction,performance characteristics and application of a new bismuth(Ⅲ) PVC membrane electrode based on 5-(3,4,5-trimethoxyphenyl)-4-amino-1,2,4-triazole-3-thiol are reported in this paper.The designed s... The construction,performance characteristics and application of a new bismuth(Ⅲ) PVC membrane electrode based on 5-(3,4,5-trimethoxyphenyl)-4-amino-1,2,4-triazole-3-thiol are reported in this paper.The designed sensor exhibited a Nernstian response for Bi^3+ ion ranging from 5.0×10^-7 mol/L to1.0×10^-2 mol/L with a slope of 19.8 mV/decade.The operational pH range of the sensor is 3.0-6.0.The electrode shows a response time of 6 s and can be used for at least five weeks without any considerable divergence in potentials.It exhibits very good selectivity relative to a wide variety of alkali,alkaline earth,transition and heavy metal ions.The proposed electrode could be used as an indicator electrode in potentiometric titration of Bi^3+ ions with EDTA and in the determination of Bi^3+ content in stomach medicine. 展开更多
关键词 Bi^3+ PVC-membrane Ion-selective electrode Potentiometry lonophore
原文传递