期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Therapeutic efficacy of methylprednisolone sodium succinate via diverse administration routes for mid-to high-frequency sudden sensorineural hearing loss
1
作者 Xiang-Da Meng Ting-Ting Li Li-Min Deng 《World Journal of Clinical Cases》 SCIE 2024年第18期3321-3331,共11页
BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use o... BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use of methylprednisolone sodium succinate(MPSS)via different administration routes,in combination with conventional medications,remains a topic of interest.AIM To compare the therapeutic efficacy of MPSS administered via different routes in combination with conventional drugs for the treatment of mid-to high-frequency SSNHL.METHODS The medical records of 109 patients with mid-to high-frequency SSNHL were analyzed.The patients were divided into three groups based on the route of administration:Group A[intratympanic(IT)injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection],Group B(intravenous injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection),and Group C(single IT injection of MPSS).The intervention effects were compared and analyzed.RESULTS The posttreatment auditory thresholds in Group A(21.23±3.34)were significantly lower than those in Groups B(28.52±3.36)and C(30.23±4.21;P<0.05).Group A also exhibited a significantly greater speech recognition rate(92.23±5.34)than Groups B and C.The disappearance time of tinnitus,time to hearing recovery,and disappearance time of vertigo in Group A were significantly shorter than those in Groups B and C(P<0.05).The total effective rate in Group A(97.56%)was significantly greater than that in Groups B and C(77.14%and 78.79%,χ^(2)=7.898,P=0.019).Moreover,the incidence of adverse reactions in Groups A and C was significantly lower than that in Group B(4.88%,3.03%vs 2.57%,χ^(2)=11.443,P=0.003),and the recurrence rate in Group A was significantly lower than that in Groups B and C(2.44%vs 20.00%vs 21.21%,χ^(2)=7.120,P=0.028).CONCLUSION IT injection of MPSS combined with conventional treatment demonstrates superior efficacy and safety compared to systemic administration via intravenous infusion and a single IT injection of MPSS.This approach effectively improves patients'hearing and reduces the risk of disease recurrence. 展开更多
关键词 Sudden loss of hearing at middle-and high-frequency of the descending type Methylprednisolone sodium succinate Intratympanic injection Intravenous injection
下载PDF
DEVELOPMENT OF REALISTIC QUALITY LOSS FUNCTIONS FOR INDUSTRIAL APPLICATIONS
2
作者 Abdul-Baasit SHAIBU Byung Rae CHO 《Journal of Systems Science and Systems Engineering》 SCIE EI CSCD 2006年第4期385-398,共14页
A number of quality loss functions, most recently the Taguchi loss function, have been developed to quantify the loss due to the deviation of product performance from the desired target value. All these loss functions... A number of quality loss functions, most recently the Taguchi loss function, have been developed to quantify the loss due to the deviation of product performance from the desired target value. All these loss functions assume the same loss at the specified specification limits. In many real life industrial applications, however, the losses at the two different specifications limits are often not the same. Further, current loss functions assume a product should be reworked or scrapped if product performance falls outside the specification limits. It is a common practice in many industries to replace a defective item rather than spending resources to repair it, especially if considerable amount of time is required. To rectify these two potential problems, this paper proposes more realistic quality loss functions for proper applications to real-world industrial problems. This paper also carries out a comparison studies of all the loss functions it considers. 展开更多
关键词 Modified quadratic loss type exponential loss type exponential loss expected loss within-specification loss out-of-specification loss
原文传递
Development of Ribbon Fiber Type Multi-Channel Power Level Monitor with Low-Insertion/Polarization Loss
3
作者 Maki Inai Akira Haraguchi +3 位作者 Takeo Komiya Kiyotaka Murashima Takashi Sasaki Kazuhito Saitoh 《光学学报》 EI CAS CSCD 北大核心 2003年第S1期181-182,共2页
We would like to propose a new in-line multi-channel power level monitor, which is applicable as tap-monitor for multi-channel WDM signals. Its ribbon fiber structure has far exceeded PLC performance and realized comp... We would like to propose a new in-line multi-channel power level monitor, which is applicable as tap-monitor for multi-channel WDM signals. Its ribbon fiber structure has far exceeded PLC performance and realized compact-size and lower insertion/polarization dependent loss. 展开更多
关键词 of on In as OADM Development of Ribbon Fiber Type Multi-Channel Power Level Monitor with Low-Insertion/Polarization loss with into Figure PDS TFF
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部