期刊文献+
共找到226篇文章
< 1 2 12 >
每页显示 20 50 100
LOW TEMPERATURE ALUMINUM FLOATING ELECTROLYSIS IN HEAVY ELECTROLYTE Na_3AlF_6-AlF_3-BaC1_2-NaCl BATH SYSTEM 被引量:4
1
作者 H.M. Lu and K.M. Fang Metallurgy School, University of Science and Technology Beijing, Beijing 100083, China Z.X. Qiu Department of Nonferrous Metallurgy, Northeastern University, Shenyang 110006, China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2000年第4期949-954,共6页
Multiple regression equations of liquidus temperature, electrical conductivity and bath density of the Na_3AlF_6-AlF_3-BaC1_2-NaCl system were obtained from experiments by using orthogonal regression method. The exper... Multiple regression equations of liquidus temperature, electrical conductivity and bath density of the Na_3AlF_6-AlF_3-BaC1_2-NaCl system were obtained from experiments by using orthogonal regression method. The experiments were carried out in 100A cell with low melting point electrolyte, the influences of cathodic current density, electrolytic temperature, density differences of bath and liquid aluminum on current efficiency (CE) were studied; when the electrolyte cryolite ratio was 2.5, w(BaC1_2) and w(NaCl) were 48% and 10%, respectively, CE reached 90% and specific energy consumption was 10.97k Wb/kg/kg. Because of the fact that aluminum metal obtained floated on the surface of molten electrolyte, this electrolysis method was then defined as low temperature aluminum floating electrolysis. The results showed that the new low temperature aluminum electrolysis process in the Na_3AlF_6-AlF_3-BaC1_2-NaCl bath system was practical and promising. 展开更多
关键词 low temperature aluminum floating electrolysis Na_3AlF_6- AlF_3BaC1_2-NaCl bath system current efficiency physico-chemical property
下载PDF
Solvents incubatedπ-πstacking in hole transport layer for perovskite-silicon 2-terminal tandem solar cells with 27.21%efficiency
2
作者 Qiaoyan Ma Jufeng Qiu +10 位作者 Yuzhao Yang Fei Tang Yilin Zeng Nanxi Ma Bohao Yu Feiping Lu Chong Liu Andreas Lambertz Weiyuan Duan Kaining Ding Yaohua Mai 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第7期25-30,I0002,共7页
Room temperature sputtered inorganic nickel oxide(NiO_(x))is one of the most promising hole transport layers(HTL)for perovskite-sillion 2-terminal tandem solar cells with the aid of ultrathin and compact organic layer... Room temperature sputtered inorganic nickel oxide(NiO_(x))is one of the most promising hole transport layers(HTL)for perovskite-sillion 2-terminal tandem solar cells with the aid of ultrathin and compact organic layers to passivate the surface defects.In this study,the aromatic solvent with different substituent groups was used to regulate the conformation of poly[bis(4-phenyl)(2,4,6-trimethylphenyl)am ine](PTAA)layer.As a result,the single-junction perovskite solar cell(PSC)gained a power conversion efficiency(PCE)of 20.63%,contributing to a 27.21%efficiency for monolithic perovskite/silicon(double-side polished)2-terminal tandem solar cell,by applying the alkyl aromatic solvent to enhance theπ-πstacking of PTAA molecular chains.The tandem solar cell can maintain 95%initial efficiency after aging over 1000 h.This study provides a universal approach for improving the photovoltaic performance of NiO_(x)/polymer-based perovskite/silicon tandem solar cells and other single junction inverted PSCs. 展开更多
关键词 Tandem solar cells low temperature deposition Hole transporting property π-πstacking Alkyl aromatic solvent
下载PDF
碳钢-水热虹吸管传热性能的实验研究 被引量:13
3
作者 张于峰 谢慧 +1 位作者 李德英 牛宝联 《天津大学学报》 EI CAS CSCD 北大核心 2006年第2期223-228,共6页
为了研究用于低温地板采暖的碳钢-水热虹吸管的传热性能,在不同的倾角(-4°-90°)、热水温度 (40-60℃)、热水流量(0.1-0.3 m3/h)、热水流向(顺流,逆流)以及蒸发段长度(30-180 mm)下进行了热管性能的实验,其中,蒸发段采用水... 为了研究用于低温地板采暖的碳钢-水热虹吸管的传热性能,在不同的倾角(-4°-90°)、热水温度 (40-60℃)、热水流量(0.1-0.3 m3/h)、热水流向(顺流,逆流)以及蒸发段长度(30-180 mm)下进行了热管性能的实验,其中,蒸发段采用水加热,冷凝段采用风冷.实验结果显示,逆流条件下热管的性能明显优于顺流时;热管的传热功率和壁面温度随热水温度和流量的增加而持续增长,随倾角和蒸发段长度的增加而先增长后下降.在实验范围内热管运行良好,其最佳运行工况为倾角38°,热水温度60℃,热水流量0.3 m3/h,蒸发段长度120 mm且蒸发段热水逆流. 展开更多
关键词 碳钢-水热虹吸管 传热性能 低温地板采暖
下载PDF
夏热冬冷地区低温辐射地板供暖影响因素的正交试验
4
作者 冯梦雅 王汉青 李正明 《科学技术与工程》 北大核心 2024年第6期2367-2377,共11页
为了研究夏热冬冷地区低温辐射地板供暖影响因素,采用L25(56)的正交试验方法探究供水温度、管间流速、管径、管间距、填充层厚度5因素对地板表面平均温度和均匀度的影响,获得各因素对试验指标的影响趋势、显著性程度和组合的最优解。研... 为了研究夏热冬冷地区低温辐射地板供暖影响因素,采用L25(56)的正交试验方法探究供水温度、管间流速、管径、管间距、填充层厚度5因素对地板表面平均温度和均匀度的影响,获得各因素对试验指标的影响趋势、显著性程度和组合的最优解。研究表明:对地板表面平均温度的影响程度为供水温度>管间距>管径>填充层厚度>管间流速,对均匀度的影响程度为管间距>供水温度>填充层厚度>管径>管间流速,最优水平组合为:供水温度取35℃,管间流速取0.4 m/s,管径取16 mm,管间距取100 mm,填充层厚度取75 mm。试验结果为夏热冬冷地区辐射供暖设计提供借鉴,亦可对数值分析软件与统计学的结合提供思路。 展开更多
关键词 低温辐射地板供暖 数值模拟 正交试验 地板表面平均温度 均匀度
下载PDF
粮食散装平房仓整仓低温储粮示范仓试验
5
作者 赵彩兰 裘骏凯 +2 位作者 陆萍 龚刘闯 杨俊俊 《粮食与食品工业》 2024年第3期58-61,共4页
本试验采用整仓低温储粮的方式,研究了试验仓粮温、冷却壁温度和粮情的变化。结果表明:采用粮面低温机组控温控湿,粮堆接触面采用冷却壁和冷却地坪控温的方式,能够实现粮堆最高温度低于15℃的设计目标,并保持了储粮品质的基本稳定。
关键词 整仓低温原理 冷却壁和地坪 低温试验 试验分析
下载PDF
兰州某教育园区综合体育馆采暖系统设计
6
作者 冯坤旋 《技术与市场》 2024年第3期79-82,共4页
以兰州某教育园区综合体育馆为例,介绍了综合体育馆在热源唯一的情况下根据综合体育馆建筑功能布置,同时考虑兰州位于西北寒冷地区的气候特点,在满足各功能分区设计参数的条件下,对整体采暖设计方案进行创新性优化,在同一建筑不同分区采... 以兰州某教育园区综合体育馆为例,介绍了综合体育馆在热源唯一的情况下根据综合体育馆建筑功能布置,同时考虑兰州位于西北寒冷地区的气候特点,在满足各功能分区设计参数的条件下,对整体采暖设计方案进行创新性优化,在同一建筑不同分区采用3种不同的采暖方式保证整体采暖系统,在满足实际使用需求的同时,达到经济合理、节能可靠的目的。 展开更多
关键词 综合体育馆 采暖设计 低温地板辐射采暖 大空间采暖
下载PDF
用于地暖系统的水-水换热装置设计
7
作者 高理福 《建筑热能通风空调》 2009年第2期64-65,共2页
通过对地暖系统使用的常规热交换机组的改进设计,可以解决常规热交换机组在使用过程中出现的采暖初、末期不能提供满足地暖系统设计要求的供水温度、机组调控能力弱、投资大等问题。现场使用证明,改进的换热装置结构简单,运行稳定。调... 通过对地暖系统使用的常规热交换机组的改进设计,可以解决常规热交换机组在使用过程中出现的采暖初、末期不能提供满足地暖系统设计要求的供水温度、机组调控能力弱、投资大等问题。现场使用证明,改进的换热装置结构简单,运行稳定。调控方便等特点,其投资费用较常规热交换装置节约30%左右。 展开更多
关键词 地暖系统 热交换机组 直连混水系统
下载PDF
快速固化水性环氧厚涂型底漆的制备及性能研究
8
作者 刘钦 王燕 熊俊 《涂层与防护》 2023年第3期13-18,共6页
采用基于腰果壳油改性的水性环氧固化剂搭配低相对分子质量液体环氧树脂以及助剂,制备了快速固化、底中合一的水性环氧地坪涂料,尤其在低温下,快速固化的特点同样能够继续保持。同时,地坪涂料具备良好的涂膜外观、粘接强度以及耐化学性... 采用基于腰果壳油改性的水性环氧固化剂搭配低相对分子质量液体环氧树脂以及助剂,制备了快速固化、底中合一的水性环氧地坪涂料,尤其在低温下,快速固化的特点同样能够继续保持。同时,地坪涂料具备良好的涂膜外观、粘接强度以及耐化学性能。缩短了施工周期,使得水性地坪涂料的快速施工成为可能。 展开更多
关键词 快速固化 水性环氧地坪涂料 低温 厚涂
下载PDF
Energy absorption potential of concrete floors containing secondary (shrinkage and temperature) reinforcements
9
作者 K. S. SIVAKUMARAN R. M. KOROL Xiao FAN 《Frontiers of Structural and Civil Engineering》 CSCD 2014年第3期282-291,共10页
This paper experimentally investigates the namely, normal density concrete and structural low-density energy absorption potential of two types of concrete floors, concrete, containing secondary (shrinkage and tempera... This paper experimentally investigates the namely, normal density concrete and structural low-density energy absorption potential of two types of concrete floors, concrete, containing secondary (shrinkage and temperature) reinforcements. The test program considered the following secondary reinforcements: 1) traditional welded-wire steel mesh, 2) steel fiber and 3) poly composite fiber. To estimate the extent to which crushing of floor slab materials would help absorb energy, a series of concrete penetration tests employing patch loading was undertaken on scaled down model slabs. Each concrete-secondary reinforcement combination considered slabs of 50 mm in depth with square plan dimensions ranging from 50 to 500 mm, resulting in a total of 30 test specimens. The first part of the paper discusses the test specimens, the test setup, and the test procedure. The second part of the paper presents the experimental results and establishes the energy absorption of different concrete- secondary reinforcement combinations. Sieve analysis results of the crushed specimens were used to derive a "work index" value that relates the pulverized particle size distributions to energy inputs. The work index values of concrete-secondary reinforcement systems can be used to assess the energy dissipation potential associated with such floor slabs in buildings undergoing progressive collapse. The results indicate that floors with secondary reinforcements could play an important role in helping arrest global progressive collapse. 展开更多
关键词 concrete floors structural low-density concrete shrinkage and temperature reinforcements energy absorption penetration tests sieve analysis
原文传递
地板辐射与散热器供暖系统经济性分析 被引量:12
10
作者 马仲元 马宏雷 +1 位作者 杨桂春 李德英 《暖通空调》 北大核心 2005年第9期58-59,36,共3页
对两种供暖系统进行了初投资和年运行费用比较,同时对其各自的优缺点进行了分析,在肯定了低温地板辐射供暖系统的优点后,得出了散热器供暖系统经济性优于地板辐射供暖系统的结论。
关键词 低温地板辐射供暖系统 散热器供暖系统 经济性分析 辐射供暖系统 地板辐射 散热器 年运行费用 低温地板 初投资
下载PDF
实用太阳能低温热水地板辐射采暖系统设计 被引量:8
11
作者 胡粉娥 魏生贤 +2 位作者 陶昌 何禧佳 赵德荣 《可再生能源》 CAS 北大核心 2010年第1期85-88,共4页
针对我国能源消耗结构带来的环境问题,在现有太阳能资源和低温地板辐射采暖理论基础上,设计了家用小型太阳能低温热水地板辐射采暖系统。介绍了系统结构和工作原理,并以云南香格里拉气象条件为例对所设计的系统进行了实例计算,在采暖代... 针对我国能源消耗结构带来的环境问题,在现有太阳能资源和低温地板辐射采暖理论基础上,设计了家用小型太阳能低温热水地板辐射采暖系统。介绍了系统结构和工作原理,并以云南香格里拉气象条件为例对所设计的系统进行了实例计算,在采暖代表日,集热器与采暖房间的面积之比约为2:5。此系统具有较好的经济、节能、环保效益,具有良好的推广应用价值。 展开更多
关键词 太阳能 低温热水地板辐射采暖 系统设计
下载PDF
低温辐射地板供暖与供新风室内热环境及通风效率实验研究 被引量:10
12
作者 吴小舟 赵加宁 王沣浩 《暖通空调》 北大核心 2015年第9期64-69,共6页
实验研究了低温辐射地板供暖系统分别与混合通风系统和置换通风系统复合时,办公房间室内热环境参数分布及新风系统的通风效率。结果表明:当辐射地板表面温度为25~29℃、送风温度为15~19℃及新风换气次数为4.2h-1时,低温辐射地板供暖与... 实验研究了低温辐射地板供暖系统分别与混合通风系统和置换通风系统复合时,办公房间室内热环境参数分布及新风系统的通风效率。结果表明:当辐射地板表面温度为25~29℃、送风温度为15~19℃及新风换气次数为4.2h-1时,低温辐射地板供暖与混合通风复合室内热环境参数分布相对比较均匀,室内空气垂直温差较小,不超过1℃,新风系统的通风效率大约为1.0;与置换通风复合室内热环境参数分布相对比较不均匀,室内空气垂直温差较大,最大能达到4℃,新风系统的通风效率为1.1左右。 展开更多
关键词 低温辐射地板供暖 混合通风 置换通风 室内热环境 通风效率 垂直温差
下载PDF
低温热水地面辐射采暖方式的热工性能分析 被引量:4
13
作者 陈艳华 刘胜君 刘江华 《建筑节能》 CAS 2008年第1期8-11,共4页
随着供暖技术的发展、建筑物功能的逐步完善和人们生活质量的不断提高,选择一种经济、实用、环保、节能、可靠的采暖方式越来越受到人们重视。以新型采暖方式——低温热水地面辐射采暖为对象,建立了研究的几何模型及数学模型。通过具体... 随着供暖技术的发展、建筑物功能的逐步完善和人们生活质量的不断提高,选择一种经济、实用、环保、节能、可靠的采暖方式越来越受到人们重视。以新型采暖方式——低温热水地面辐射采暖为对象,建立了研究的几何模型及数学模型。通过具体的传热性能方面的计算和分析,从物体表面得热角度与传统散热器采暖方式对比,阐明了低温热水地面辐射采暖系统的优势。进一步揭示了低温热水地面辐射采暖室内温度比散热器采暖低2℃的理论根据,完善了低温地面辐射的理论研究,也为开发和改进新型采暖技术提供依据。 展开更多
关键词 低温热水 辐射 地面采暖 散热器采暖
下载PDF
低温热水地板与热泵空调器采暖测试对比分析 被引量:4
14
作者 王文 何雪冰 +2 位作者 陈建苹 张素云 刘宪英 《重庆建筑大学学报》 CSCD 2001年第2期43-50,共8页
通过对重庆地区一住宅内低温热水地板供暖系统的测试 ,分析对比了该系统与热泵空调器采暖方式对室内热舒适性的影响及运行费用的差别 ,同时对地板辐射和对流散热的综合效果进行分析 。
关键词 低温热水 地板采暖 热泵 空调器 舒适性 测试
下载PDF
低温地板辐射供暖特性参数的研究 被引量:7
15
作者 冯晓梅 肖勇全 《暖通空调》 北大核心 2004年第1期1-4,共4页
建立了低温地板辐射供暖房间各围护结构的热平衡关系式 ,计算了地板表面温度、热流密度、室内空气温度和围护结构内表面温度。介绍了计算地板表面温度和围护结构内表面温度的耦合程序 ,测试了地板辐射供暖房间的特性参数。
关键词 低温地板辐射供暖 热平衡 数值计算 围护结构 热流密度 耦合程序
下载PDF
新型低温热水辐射供暖地面与墙面构造实验研究 被引量:9
16
作者 费玉敏 王随林 闫全英 《暖通空调》 北大核心 2011年第12期71-73,83,共4页
介绍了新型低温热水辐射供暖地面和墙面的构造并建立了实验系统。实验研究了地面供暖和墙面供暖的热工性能,地面辐射供暖分别采用了木地板面层和瓷砖面层,墙面辐射供暖分别采用了有孔蜂窝铝板面层和无孔蜂窝铝板面层。实验结果表明,对... 介绍了新型低温热水辐射供暖地面和墙面的构造并建立了实验系统。实验研究了地面供暖和墙面供暖的热工性能,地面辐射供暖分别采用了木地板面层和瓷砖面层,墙面辐射供暖分别采用了有孔蜂窝铝板面层和无孔蜂窝铝板面层。实验结果表明,对于墙面辐射供暖,有孔蜂窝铝板加热面的温度及热流密度大于无孔蜂窝铝板;对于地面辐射供暖,瓷砖面层的表面温度及热流密度大于木地板。地面辐射供暖的辐射传热比例大于57%,墙面辐射供暖的辐射传热比例大于65%。 展开更多
关键词 低温热水辐射供暖 辐射地面构造 辐射墙面构造 热工性能 实验
下载PDF
低温地板辐射采暖系统中辐射板布置方式的优化 被引量:7
17
作者 刘成林 杨昌智 《节能技术》 CAS 2004年第2期6-8,共3页
低温地板辐射采暖系统作为一种既节能又舒适的新型采暖方式 ,国内外对其节能性和节能能力进行了相当多的研究 ,但对如何进行低温地板辐射采暖系统优化设计的研究很少 ,本文基于热网模型 ,利用数值模拟 ,在等舒适度情况下对不同的辐射板... 低温地板辐射采暖系统作为一种既节能又舒适的新型采暖方式 ,国内外对其节能性和节能能力进行了相当多的研究 ,但对如何进行低温地板辐射采暖系统优化设计的研究很少 ,本文基于热网模型 ,利用数值模拟 ,在等舒适度情况下对不同的辐射板的布置方式 (周边布置和中心布置 )和辐射板铺设位置的情况下的能耗进行分析 ,并进一步对如何优化辐射板铺设位置进行了探讨 。 展开更多
关键词 低温地板 辐射采暖系统 辐射板布置方式 节能 布置优化
下载PDF
硼泥陶粒混凝土用于低温热水地板辐射供暖 被引量:4
18
作者 李井永 刘春泽 +2 位作者 周大伟 王芳 齐毅 《沈阳建筑大学学报(自然科学版)》 EI CAS 2005年第6期697-700,共4页
目的研究硼泥陶粒混凝土作为低温热水地板辐射供暖系统蓄热层的作法及其性能.方法辽化湖畔花园小区住宅楼工程中,用硼泥陶粒混凝土代替豆石混凝土作低温热水地板辐射供暖系统蓄热层,取暖期内对试验工程进行温度监测实验.结果试验工程混... 目的研究硼泥陶粒混凝土作为低温热水地板辐射供暖系统蓄热层的作法及其性能.方法辽化湖畔花园小区住宅楼工程中,用硼泥陶粒混凝土代替豆石混凝土作低温热水地板辐射供暖系统蓄热层,取暖期内对试验工程进行温度监测实验.结果试验工程混凝土试块强度平均值为27.5 MPa,合格率为100%,厚度均在允许偏差内,合格率100%;外观鉴定混凝土表面无裂缝,并根据温度监测结果画出了取暖期内每天温度随时间变化的曲线图.结论用硼泥陶粒混凝土作低温热水地板辐射供暖系统的蓄热层,与用豆石混凝土相比,减轻了建筑物自重、减缓了传热速度、增强了房间的热稳定性. 展开更多
关键词 低温热水地板辐射供暖系统 硼泥陶粒 硼泥陶粒混凝土 施工工艺
下载PDF
太阳辐射照度对供暖热过程影响研究 被引量:3
19
作者 戎向阳 王磊 +1 位作者 冯雅 余南阳 《暖通空调》 北大核心 2008年第1期19-23,共5页
模拟了低温地板辐射供暖与对流散热器供暖系统在不同太阳辐射照度下的动态热过程。对比了室内温度及供暖耗热量等指标,结果表明在高太阳辐射照度地区地板辐射供暖系统室内过热现象更明显,地板辐射供暖能耗与散热器供暖能耗比值随太阳辐... 模拟了低温地板辐射供暖与对流散热器供暖系统在不同太阳辐射照度下的动态热过程。对比了室内温度及供暖耗热量等指标,结果表明在高太阳辐射照度地区地板辐射供暖系统室内过热现象更明显,地板辐射供暖能耗与散热器供暖能耗比值随太阳辐射照度的增大而增加,因此选择高太阳辐射照度地区的供暖形式时应优先采用热响应较快的散热器供暖形式。 展开更多
关键词 太阳能 低温地板辐射供暖 对流散热器供暖 建筑节能
下载PDF
通水间断时长对太阳能低温地板采暖系统供暖性能的影响 被引量:3
20
作者 李金平 徐奥博 +2 位作者 甄箫斐 黄娟娟 王春龙 《农业工程学报》 EI CAS CSCD 北大核心 2018年第24期217-223,共7页
为了揭示供暖水泵通断模式对太阳能低温地板采暖系统供暖性能的影响,试验和理论研究了通水时长相同间断时长不同时系统的供回水温差变化规律,分析了系统的供热量、热损失率、运行能耗及太阳能保证率的变化,研究了供暖时系统内外因素与... 为了揭示供暖水泵通断模式对太阳能低温地板采暖系统供暖性能的影响,试验和理论研究了通水时长相同间断时长不同时系统的供回水温差变化规律,分析了系统的供热量、热损失率、运行能耗及太阳能保证率的变化,研究了供暖时系统内外因素与供热量的相关性,研究结果表明:太阳能采暖系统23 d不同通断模式的运行试验结果表明,环境条件相近及通水时长都为8min时,间断时长越长,供回水温差越大;系统在3种通断模式下的供热量由高到低依次为间断6、5、11 min;间断6 min时比间断5 min时系统太阳能保证率增多5.27%,热损失率减少2.79%,运行能耗减少6.67%,对比可得间断6 min时系统运行较好;由23 d的运行效果可得,间断6 min时系统平均供热效率最高;室外温度、供水温度、回水温度、流量、风速等因素与供热量都有显著相关性,供水温度和环境温度对系统供热量影响较大,循环流量和环境风速的影响较小。 展开更多
关键词 太阳能 供暖 温度 太阳能低温地板采暖系统 通断模式 太阳能保证率 供热量 运行能耗
下载PDF
上一页 1 2 12 下一页 到第
使用帮助 返回顶部