Air channeling in the annulus between the casing and the cement sheath and/or between the cement sheath and formation is the main factor affecting the safe operation of natural gas wells at high temperatures and press...Air channeling in the annulus between the casing and the cement sheath and/or between the cement sheath and formation is the main factor affecting the safe operation of natural gas wells at high temperatures and pressures.Prevention of this problem requires,in general,excellent anti-channeling performances of the cement sheath.Three methods to predict such anti-channeling performances are proposed here,which use the weightless pressure of cement slurry,the permeability of cement stone and the volume expansion rate of cement sheath as input parameters.Guided by this approach,the anti-channeling performances of the cement slurry are evaluated by means of indoor experiments,and the cement slurry is optimized accordingly.The results show that the dangerous transition time of the cement slurry with optimized dosage of admixture is only 76 min,the permeability of cement stone is 0.005 md,the volume shrinkage at final setting is only 0.72%,and the anti-channeling performances are therefore maximized.The effective utilization of the optimized cement slurry in some representative wells(LD10–1-A1 and LD10–1-A2 in LD10–1 gas field)is also discussed.展开更多
Cementing carbonate reservoirs is generally a difficult task.The so-called thixotropic cement slurry has gained considerable attention in this regard as it can help tofix some notable problems.More precisely,it can ea...Cementing carbonate reservoirs is generally a difficult task.The so-called thixotropic cement slurry has gained considerable attention in this regard as it can help tofix some notable problems.More precisely,it can easilyfill the leakage layer;moreover,its gelling strength can grow rapidly when pumping stops,thereby increasing the resistance to gas channeling,effectively preventing this undesired phenomenon in many cases.High-temperature thixotropic cement slurry systems,however,are still in an early stage of development and additional research is needed to make them a viable option.In the present study,using a self-developed composite high-temperature thixotropic additive as a basis,it is shown that the compressive strength can be adjusted by tuning the proportion of silica sand,the high-temperature retarder,fluid loss additive and dispersant(compatible with the thixotropic additive).According to the tests,the developed high-temperature thixotropic cement slurry system has a 14 d compressive strength of 29.73 MPa at 150°C,and a thickening time of 330 min when the dosage of retarder is 2%.At the same time,the rheological property,water loss,permeability,water separation rate,and settlement stability of the cement slurry system meet the requirements of cementing construction.展开更多
随着可再生能源接入电网比例的逐步增大,热力发电厂需要应对更加频繁、更大范围的负荷变化,给电厂的高阶大惯性过热汽温过程的控制带来严峻的挑战。为此,文中针对一类高阶大惯性过热汽温过程,提出一种基于相位补偿的自抗扰控制(phase co...随着可再生能源接入电网比例的逐步增大,热力发电厂需要应对更加频繁、更大范围的负荷变化,给电厂的高阶大惯性过热汽温过程的控制带来严峻的挑战。为此,文中针对一类高阶大惯性过热汽温过程,提出一种基于相位补偿的自抗扰控制(phase compensation based active disturbance rejection control,PC-ADRC)方法。首先,阐述过热汽温系统的工作原理和控制难点。然后,采用低频近似法详细推导相位补偿(phase compensation,PC)网络模型,提出采用PC网络对模型动态特性进行补偿,得到等效降阶模型的简化思路。为便于工程应用,给出PC-ADRC系统的简单实现方法和等效模型分析。最后,对PC-ADRC系统的稳定性和鲁棒性进行研究。理论分析和仿真结果表明,所提出的PC-ADRC系统能有效提升高阶过程控制系统的鲁棒性和快速响应能力。展开更多
This study aimed at assessing the usefulness of carbon microfiber (CMF) in improving the compressive-toughness of sodium metasilicate-activated calcium aluminate/Class F fly ash foamed cement at hydrothermal temperatu...This study aimed at assessing the usefulness of carbon microfiber (CMF) in improving the compressive-toughness of sodium metasilicate-activated calcium aluminate/Class F fly ash foamed cement at hydrothermal temperatures of up to 300°C. When the CMFs came in contact with a pore solution of cement, their surfaces underwent alkali-caused oxidation, leading to the formation of metal (Na, Ca, Al)-complexed carboxylate groups. The extent of this oxidation was enhanced by the temperature increase, corresponding to the incorporation of more oxidation derivatives at higher temperatures. Although micro-probe examinations did not show any defects in the fibers, the enhanced oxidation engendered shrinkage of the interlayer spacing between the C-basal planes in CMFs, and a decline in their thermal stability. On the other hand, the complexed carboxylate groups present on the surfaces of oxidized fibers played a pivotal role in improving the adherence of fibers to the cement matrix. Such fiber/cement interfacial bonds contributed significantly to the excellent bridging effect of fibers, resistance to the cracks development and propagation, and to improvement of the post-crack material ductility. Consequently, the compressive toughness of the 85°-, 200°-, and 300°C-autoclaved foamed cements reinforced with 10 wt% CMF was 2.4-, 2.9-, and 3.1-fold higher than for cement without the reinforcement.展开更多
基金funded by the CNOOC Scientific Research Project“Study of cementing key properties and its matching technology of LD-10 gas field”(Grant No.CCL2019ZJFN1227).
文摘Air channeling in the annulus between the casing and the cement sheath and/or between the cement sheath and formation is the main factor affecting the safe operation of natural gas wells at high temperatures and pressures.Prevention of this problem requires,in general,excellent anti-channeling performances of the cement sheath.Three methods to predict such anti-channeling performances are proposed here,which use the weightless pressure of cement slurry,the permeability of cement stone and the volume expansion rate of cement sheath as input parameters.Guided by this approach,the anti-channeling performances of the cement slurry are evaluated by means of indoor experiments,and the cement slurry is optimized accordingly.The results show that the dangerous transition time of the cement slurry with optimized dosage of admixture is only 76 min,the permeability of cement stone is 0.005 md,the volume shrinkage at final setting is only 0.72%,and the anti-channeling performances are therefore maximized.The effective utilization of the optimized cement slurry in some representative wells(LD10–1-A1 and LD10–1-A2 in LD10–1 gas field)is also discussed.
基金funded by the National Natural Science Foundation of China(51974355).
文摘Cementing carbonate reservoirs is generally a difficult task.The so-called thixotropic cement slurry has gained considerable attention in this regard as it can help tofix some notable problems.More precisely,it can easilyfill the leakage layer;moreover,its gelling strength can grow rapidly when pumping stops,thereby increasing the resistance to gas channeling,effectively preventing this undesired phenomenon in many cases.High-temperature thixotropic cement slurry systems,however,are still in an early stage of development and additional research is needed to make them a viable option.In the present study,using a self-developed composite high-temperature thixotropic additive as a basis,it is shown that the compressive strength can be adjusted by tuning the proportion of silica sand,the high-temperature retarder,fluid loss additive and dispersant(compatible with the thixotropic additive).According to the tests,the developed high-temperature thixotropic cement slurry system has a 14 d compressive strength of 29.73 MPa at 150°C,and a thickening time of 330 min when the dosage of retarder is 2%.At the same time,the rheological property,water loss,permeability,water separation rate,and settlement stability of the cement slurry system meet the requirements of cementing construction.
文摘随着可再生能源接入电网比例的逐步增大,热力发电厂需要应对更加频繁、更大范围的负荷变化,给电厂的高阶大惯性过热汽温过程的控制带来严峻的挑战。为此,文中针对一类高阶大惯性过热汽温过程,提出一种基于相位补偿的自抗扰控制(phase compensation based active disturbance rejection control,PC-ADRC)方法。首先,阐述过热汽温系统的工作原理和控制难点。然后,采用低频近似法详细推导相位补偿(phase compensation,PC)网络模型,提出采用PC网络对模型动态特性进行补偿,得到等效降阶模型的简化思路。为便于工程应用,给出PC-ADRC系统的简单实现方法和等效模型分析。最后,对PC-ADRC系统的稳定性和鲁棒性进行研究。理论分析和仿真结果表明,所提出的PC-ADRC系统能有效提升高阶过程控制系统的鲁棒性和快速响应能力。
文摘This study aimed at assessing the usefulness of carbon microfiber (CMF) in improving the compressive-toughness of sodium metasilicate-activated calcium aluminate/Class F fly ash foamed cement at hydrothermal temperatures of up to 300°C. When the CMFs came in contact with a pore solution of cement, their surfaces underwent alkali-caused oxidation, leading to the formation of metal (Na, Ca, Al)-complexed carboxylate groups. The extent of this oxidation was enhanced by the temperature increase, corresponding to the incorporation of more oxidation derivatives at higher temperatures. Although micro-probe examinations did not show any defects in the fibers, the enhanced oxidation engendered shrinkage of the interlayer spacing between the C-basal planes in CMFs, and a decline in their thermal stability. On the other hand, the complexed carboxylate groups present on the surfaces of oxidized fibers played a pivotal role in improving the adherence of fibers to the cement matrix. Such fiber/cement interfacial bonds contributed significantly to the excellent bridging effect of fibers, resistance to the cracks development and propagation, and to improvement of the post-crack material ductility. Consequently, the compressive toughness of the 85°-, 200°-, and 300°C-autoclaved foamed cements reinforced with 10 wt% CMF was 2.4-, 2.9-, and 3.1-fold higher than for cement without the reinforcement.