期刊文献+
共找到4,285篇文章
< 1 2 215 >
每页显示 20 50 100
Atmospheric transmission algorithm for pulsed X-rays from high-altitude nuclear detonations based on scattering correction
1
作者 Ding-Han Zhu Xiong Zhang +3 位作者 Xiao-Qiang Li Peng Li Yan-Bin Wang Shuang Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期40-52,共13页
In high-altitude nuclear detonations,the proportion of pulsed X-ray energy can exceed 70%,making it a specific monitoring signal for such events.These pulsed X-rays can be captured using a satellite-borne X-ray detect... In high-altitude nuclear detonations,the proportion of pulsed X-ray energy can exceed 70%,making it a specific monitoring signal for such events.These pulsed X-rays can be captured using a satellite-borne X-ray detector following atmospheric transmission.To quantitatively analyze the effects of different satellite detection altitudes,burst heights,and transmission angles on the physical processes of X-ray transport and energy fluence,we developed an atmospheric transmission algorithm for pulsed X-rays from high-altitude nuclear detonations based on scattering correction.The proposed method is an improvement over the traditional analytical method that only computes direct-transmission X-rays.The traditional analytical method exhibits a maximum relative error of 67.79% compared with the Monte Carlo method.Our improved method reduces this error to within 10% under the same conditions,even reaching 1% in certain scenarios.Moreover,its computation time is 48,000 times faster than that of the Monte Carlo method.These results have important theoretical significance and engineering application value for designing satellite-borne nuclear detonation pulsed X-ray detectors,inverting nuclear detonation source terms,and assessing ionospheric effects. 展开更多
关键词 High-altitude nuclear detonation Atmospheric transmission Pulsed x-rays Scattering correction Analytical method Monte Carlo method
下载PDF
Pulmonary Edema and Pleural Effusion Detection Using Efficient Net-V1-B4 Architecture and AdamW Optimizer from Chest X-Rays Images
2
作者 Anas AbuKaraki Tawfi Alrawashdeh +4 位作者 Sumaya Abusaleh Malek Zakarya Alksasbeh Bilal Alqudah Khalid Alemerien Hamzah Alshamaseen 《Computers, Materials & Continua》 SCIE EI 2024年第7期1055-1073,共19页
This paper presents a novelmulticlass systemdesigned to detect pleural effusion and pulmonary edema on chest Xray images,addressing the critical need for early detection in healthcare.A new comprehensive dataset was f... This paper presents a novelmulticlass systemdesigned to detect pleural effusion and pulmonary edema on chest Xray images,addressing the critical need for early detection in healthcare.A new comprehensive dataset was formed by combining 28,309 samples from the ChestX-ray14,PadChest,and CheXpert databases,with 10,287,6022,and 12,000 samples representing Pleural Effusion,Pulmonary Edema,and Normal cases,respectively.Consequently,the preprocessing step involves applying the Contrast Limited Adaptive Histogram Equalization(CLAHE)method to boost the local contrast of the X-ray samples,then resizing the images to 380×380 dimensions,followed by using the data augmentation technique.The classification task employs a deep learning model based on the EfficientNet-V1-B4 architecture and is trained using the AdamW optimizer.The proposed multiclass system achieved an accuracy(ACC)of 98.3%,recall of 98.3%,precision of 98.7%,and F1-score of 98.7%.Moreover,the robustness of the model was revealed by the Receiver Operating Characteristic(ROC)analysis,which demonstrated an Area Under the Curve(AUC)of 1.00 for edema and normal cases and 0.99 for effusion.The experimental results demonstrate the superiority of the proposedmulti-class system,which has the potential to assist clinicians in timely and accurate diagnosis,leading to improved patient outcomes.Notably,ablation-CAM visualization at the last convolutional layer portrayed further enhanced diagnostic capabilities with heat maps on X-ray images,which will aid clinicians in interpreting and localizing abnormalities more effectively. 展开更多
关键词 Image classification decision support system EfficientNet-V1-B4 AdamW optimizer pulmonary edema pleural effusion chest x-rays
下载PDF
Single Tooth Segmentation on Panoramic X-Rays Using End-to-End Deep Neural Networks
3
作者 Yu Sun Jing Feng +5 位作者 Huang Du Juan Liu Baochuan Pang Cheng Li Jinxian Li Dehua Cao 《Open Journal of Stomatology》 2024年第6期316-326,共11页
In dentistry, panoramic X-ray images are extensively used by dentists for tooth structure analysis and disease diagnosis. However, the manual analysis of these images is time-consuming and prone to misdiagnosis or ove... In dentistry, panoramic X-ray images are extensively used by dentists for tooth structure analysis and disease diagnosis. However, the manual analysis of these images is time-consuming and prone to misdiagnosis or overlooked. While deep learning techniques have been employed to segment teeth in panoramic X-ray images, accurate segmentation of individual teeth remains an underexplored area. In this study, we propose an end-to-end deep learning method that effectively addresses this challenge by employing an improved combinatorial loss function to separate the boundaries of adjacent teeth, enabling precise segmentation of individual teeth in panoramic X-ray images. We validate the feasibility of our approach using a challenging dataset. By training our segmentation network on 115 panoramic X-ray images, we achieve an intersection over union (IoU) of 86.56% for tooth segmentation and an accuracy of 65.52% in tooth counting on 87 test set images. Experimental results demonstrate the significant improvement of our proposed method in single tooth segmentation compared to existing methods. 展开更多
关键词 Single Tooth Segmentation Teeth Counting Panoramic X-Ray Combinatorial Loss
下载PDF
A refined Monte Carlo code for low-energy electron emission from gold material irradiated with sub-keV electrons
4
作者 Li-Heng Zhou Shui-Yan Cao +2 位作者 Tao Sun Yun-Long Wang Jun Ma 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第4期79-92,共14页
Considering the significance of low-energy electrons(LEEs;0–20 eV) in radiobiology, the sensitization potential of gold nanoparticles(AuNPs) as high-flux LEE emitters when irradiated with sub-keV electrons has been s... Considering the significance of low-energy electrons(LEEs;0–20 eV) in radiobiology, the sensitization potential of gold nanoparticles(AuNPs) as high-flux LEE emitters when irradiated with sub-keV electrons has been suggested. In this study, a track-structure Monte Carlo simulation code using the dielectric theory was developed to simulate the transport of electrons below 50 keV in gold. In this code, modifications, particularly for elastic scattering, are implemented for a more precise description of the LEE emission in secondary electron emission. This code was validated using the secondary electron yield and backscattering coefficient. To ensure dosimetry accuracy, we further verified the code for energy deposition calculations using the Monte Carlo toolkit, Geant4. The development of this code provides a basis for future studies regarding the role of AuNPs in targeted radionuclide radiotherapy. 展开更多
关键词 Monte Carlo code Secondary electron emission low-energy electrons
下载PDF
Role of contrast-enhanced serial/spot abdominal X-rays in perioperative follow-up of patients undergoing abdominal surgery:An observational clinical study
5
作者 Osman Nuri Dilek Arif Atay +2 位作者 Orgun Gunes Furkan Karahan Şebnem Karasu 《World Journal of Radiology》 2023年第6期191-200,共10页
BACKGROUND Many imaging methods such as ultrasonography,computed tomography(CT),magnetic resonance imaging,and endoscopy are used to identify the problems or complications that occur in the perioperative period and to... BACKGROUND Many imaging methods such as ultrasonography,computed tomography(CT),magnetic resonance imaging,and endoscopy are used to identify the problems or complications that occur in the perioperative period and to determine the appropriate therapeutic approach.Specialists at surgical clinics and intensive care units sometimes need diagnostic procedures that can give quick results or reveal unexpected results.In particular,rapid on-site evaluation of patients followed under intensive care conditions has several advantages.AIM To determine the problems developing in patients in the perioperative period by contrast-enhanced abdominal X-ray(CE-AXR),revealing their current status or defining the effectiveness of CE-AXR.METHODS The files of the patients who underwent hepatopancreatobiliary or upper gastrointestinal surgery,whose CE-AXR film was taken,were reviewed retrospectively.Abdominal X-ray radiographs taken after ingestion of a watersoluble contrast agent(iohexol,300 mg,50 cc vial)and its application in a drain,nasogastric tube,or stent were evaluated.The contribution of the data obtained in patients who underwent CE-AXR to the diagnosis,follow-up,and treatment processes and the effectiveness of the application were investigated.RESULTS CE-AXR was applied to 131 patients in our clinic,most of whom underwent hepatopancreatobiliary or upper gastrointestinal surgery.It was determined that the data obtained from CE-AXR films taken in 98(74.8%)of the patients contributed to the diagnosis,treatment,and follow-up expectations and positively affected the clinical processes.CONCLUSION CE-AXR is a simple procedure that can be applied anywhere,especially in intensive care patients and at bedside,with a portable X-ray device.The simplicity of the procedure,less radiation exposure for the patients,less time wastage,reduction in the CT and endoscopy procedure burden and costs,quick results,rapid assessment of the situation,and enabling the monitoring of processes with repetitive procedures are important advantages.X-rays taken will be useful in terms of being a reference value during the follow-up period of the patient and determining the situation in medicolegal processes. 展开更多
关键词 Abdominal x-rays Contrast medium Diagnosis COMPLICATION Leakage Radiation exposure
下载PDF
Histogram Matched Chest X-Rays Based Tuberculosis Detection Using CNN
6
作者 Joe Louis Paul Ignatius Sasirekha Selvakumar +3 位作者 Kavin Gabriel Joe Louis Paul Aadhithya B.Kailash S.Keertivaas S.A.J.Akarvin Raja Prajan 《Computer Systems Science & Engineering》 SCIE EI 2023年第1期81-97,共17页
Tuberculosis(TB)is a severe infection that mostly affects the lungs and kills millions of people’s lives every year.Tuberculosis can be diagnosed using chest X-rays(CXR)and data-driven deep learning(DL)approaches.Bec... Tuberculosis(TB)is a severe infection that mostly affects the lungs and kills millions of people’s lives every year.Tuberculosis can be diagnosed using chest X-rays(CXR)and data-driven deep learning(DL)approaches.Because of its better automated feature extraction capability,convolutional neural net-works(CNNs)trained on natural images are particularly effective in image cate-gorization.A combination of 3001 normal and 3001 TB CXR images was gathered for this study from different accessible public datasets.Ten different deep CNNs(Resnet50,Resnet101,Resnet152,InceptionV3,VGG16,VGG19,DenseNet121,DenseNet169,DenseNet201,MobileNet)are trained and tested for identifying TB and normal cases.This study presents a deep CNN approach based on histogram matched CXR images that does not require object segmenta-tion of interest,and this coupled methodology of histogram matching with the CXRs improves the accuracy and detection performance of CNN models for TB detection.Furthermore,this research contains two separate experiments that used CXR images with and without histogram matching to classify TB and non-TB CXRs using deep CNNs.It was able to accurately detect TB from CXR images using pre-processing,data augmentation,and deep CNN models.Without histogram matching the best accuracy,sensitivity,specificity,precision and F1-score in the detection of TB using CXR images among ten models are 99.25%,99.48%,99.52%,99.48%and 99.22%respectively.With histogram matching the best accuracy,sensitivity,specificity,precision and F1-score are 99.58%,99.82%,99.67%,99.65%and 99.56%respectively.The proposed meth-odology,which has cutting-edge performance,will be useful in computer-assisted TB diagnosis and aids in minimizing irregularities in TB detection in developing countries. 展开更多
关键词 Tuberculosis detection chest x-ray(CXR) convolutional neural networks(CNNs) transfer learning histogram matching
下载PDF
17例耳硬化症患者的临床与影像学分析
7
作者 魏建初 张敏 +1 位作者 何云生 胡先芳 《中国耳鼻咽喉头颈外科》 CSCD 2024年第4期266-268,共3页
目的分析17例耳硬化症患者的临床特征、影像学表现及手术治疗效果。方法收集2020年5月~2023年5月在湖州市中心医院接受手术治疗的17例(17耳)耳硬化症患者临床、影像学资料,分析其临床表现、颞骨CT影像学表现及手术前后纯音测听结果变化... 目的分析17例耳硬化症患者的临床特征、影像学表现及手术治疗效果。方法收集2020年5月~2023年5月在湖州市中心医院接受手术治疗的17例(17耳)耳硬化症患者临床、影像学资料,分析其临床表现、颞骨CT影像学表现及手术前后纯音测听结果变化。结果17例(17耳)患者中,11耳(64.71%)为前庭窗型,表现为进行性传导性听力损失,其中9耳有耳鸣,3耳有轻微平衡问题;混合型6耳(35.29%)显示混合性听力损失,5耳有耳鸣,3耳有偶发性平衡障碍。影像学上,前庭窗型显示镫骨底板区域骨质增厚、前庭窗密度增加;混合型则显示镫骨底板增厚及耳蜗周围密度减低,1耳可见“双环征”,两种类型耳硬化症患者骨密度差异无统计学意义(P>0.05)。术后均未见耳鸣加重或其他严重并发症,仅2例(11.76%)出现暂时性头晕,术后随访显示术区恢复良好,无感染或其他迟发性并发症;术后听力测试显示气导阈值、气骨导差较术前显著改善(P均<0.05)。结论前庭窗型和混合型耳硬化症的影像学和临床表现各有特点,镫骨成形术可显著改善听力,降低气导阈值和气骨导差,且手术安全、并发症少。 展开更多
关键词 耳硬化(Otosclerosis) 体征和症状(Signs and Symptoms) 颞骨(Temporal Bone) 体层摄影术 X线计算机(Tomography X-Ray Computed) 测听法 纯音(Audiometry Pure-Tone) 听阈(Auditory Threshold)
下载PDF
基于CT图像的水泥稳定RAP材料细观结构研究 被引量:1
8
作者 阳虎 单丽岩 李志伟 《材料导报》 EI CSCD 北大核心 2024年第1期66-71,共6页
研究沥青混合料回收料(RAP)掺加对混合料组成与结构特性的影响,可为其应用在路面结构层以及材料参数设计提供理论支撑。基于X-ray CT与图像处理技术,提出了一种可区分新旧集料的冷再生混合料细观结构识别方法,分析了RAP团粒、旧集料与... 研究沥青混合料回收料(RAP)掺加对混合料组成与结构特性的影响,可为其应用在路面结构层以及材料参数设计提供理论支撑。基于X-ray CT与图像处理技术,提出了一种可区分新旧集料的冷再生混合料细观结构识别方法,分析了RAP团粒、旧集料与新集料的细观特征的差异,研究了RAP的掺加对水泥稳定材料细观结构的影响。结果表明:提出的细观结构识别方法可准确识别水泥稳定RAP材料断面图像中的空隙、砂浆、新集料与旧集料四类区域,完整地保留新旧集料的原始轮廓、大小与形状等信息;RAP团粒中分布较多初始微细裂缝,且旧集料扁平比与棱角性系数均大于新集料;RAP的掺加一方面增加了再生混合料中体积小于0.01 mm3的微空隙与大于100 mm3的大空隙数量,导致材料的密实度降低;另一方面也增加了材料的沥青砂浆含量,提高了再生混合料的平均砂浆膜厚度,使混合料骨架内部力传导更均匀;提高水泥稳定RAP材料中石屑与碎石比例,可使材料的平均空隙体积减小、平均砂浆膜厚度增大,从而改善再生混合料的骨架填充状态。 展开更多
关键词 RAP 水泥稳定材料 X-ray CT 细观结构 冷再生技术
下载PDF
M^(3)Res-Transformer:新冠肺炎胸部X-ray图像识别模型 被引量:1
9
作者 周涛 刘赟璨 +3 位作者 侯森宝 常晓玉 叶鑫宇 陆惠玲 《电子学报》 EI CAS CSCD 北大核心 2024年第2期589-601,共13页
新冠肺炎(COVID-19)自爆发以来严重影响人类生命健康,近年来残差神经网络广泛应用于COVID-19识别任务中,辅助医生快速地诊断COVID-19患者,但是COVID-19图像病变区域形状复杂、大小不一,与周围组织的边界模糊,导致网络难以提取有效特征.... 新冠肺炎(COVID-19)自爆发以来严重影响人类生命健康,近年来残差神经网络广泛应用于COVID-19识别任务中,辅助医生快速地诊断COVID-19患者,但是COVID-19图像病变区域形状复杂、大小不一,与周围组织的边界模糊,导致网络难以提取有效特征.本文针对上述问题,提出一种M^(3)Res-Transformer的新冠肺炎胸部X-ray图像识别模型,采用Res-Transformer作为模型的主干网络,结合ResNet和ViT,有效地整合局部病变特征和全局特征;设计混合残差注意力模块(mixed residual attention Module,mraM),同时考虑通道和空间位置的相互依赖性,增强网络的特征表达能力;为了增大感受野,提取多尺度特征,通过叠加具有不同扩张率的扩张卷积构造多尺度扩张残差模块(multiscale dilated residual Module,mdrM),根据不同层次特征尺度的差异,使用3个逐渐收缩尺度的mdrM进行多尺度特征提取;提出上下文交叉感知模块(contextual cross-awareness Module,ccaM),使用深层特征中的语义信息来引导浅层特征,然后将浅层特征中的空间信息嵌入深层特征中,采用交叉加权注意力机制高效聚合深层和浅层特征,获得更丰富的上下文信息.为了验证本文所提模型的有效性,在新冠肺炎胸部X-ray图像数据集上进行实验,与先进的CNN分类模型、融合不同注意力机制的ResNet50模型、基于Transformer的分类模型对比以及消融实验.结果表明,本文所提模型的Acc、Pre、Rec、F1-Score与Spe指标分别为96.33%、96.36%、96.33%、96.35%与96.26%,在COVID-19胸部X-ray图像识别任务中有效提升了识别精度,并通过可视化方法对其进行进一步验证,为COVID-19的辅助诊断提供重要的参考价值. 展开更多
关键词 COVID-19 胸部X-ray图像 残差神经网络 vision transformer 注意力机制
下载PDF
X-ray在鱼体组织及微量元素检测中的应用
10
作者 宋一帆 张胜茂 +4 位作者 张衡 唐峰华 张寒野 石永闯 崔雪森 《应用光学》 CAS 北大核心 2024年第1期166-176,共11页
鱼类硬质组织物,特别是骨骼支持鱼体和保护其体内器官的组织,对其进行特征检测分析是研究鱼类游泳运动、鱼类解剖、鱼体建模等的数据基础。随着X-ray技术的发展和国产设备的广泛应用,其仪器设备成本明显降低,使得X-ray在渔业研究与自动... 鱼类硬质组织物,特别是骨骼支持鱼体和保护其体内器官的组织,对其进行特征检测分析是研究鱼类游泳运动、鱼类解剖、鱼体建模等的数据基础。随着X-ray技术的发展和国产设备的广泛应用,其仪器设备成本明显降低,使得X-ray在渔业研究与自动化生产中的应用成为可能。首先介绍了X-ray技术的基本原理与其在鱼体组织检测中的应用,X-ray技术在鱼体组织及微量元素检测中的应用主要分为鱼类组织器官的无损检测和鱼体微量元素检测两部分,其中分别介绍了包括照相法、数字成像法、衍射技术和吸收光谱法等X-ray技术;然后综述其在鱼体组织器官建模、鱼骨检测、鱼类化石研究、鱼耳石分析和鱼体微量元素检测方面的应用,总结了Xray在渔业领域应用中存在的问题;最后对X-ray的渔业应用方向进行展望。 展开更多
关键词 X-RAY 鱼体骨骼 鱼类耳石 鱼体建模 鱼体微量元素
下载PDF
Global hybrid simulations of soft X-ray emissions in the Earth’s magnetosheath 被引量:2
11
作者 Jin Guo TianRan Sun +6 位作者 San Lu QuanMing Lu Yu Lin XueYi Wang Chi Wang RongSheng Wang Kai Huang 《Earth and Planetary Physics》 EI CSCD 2024年第1期47-58,共12页
Earth’s magnetopause is a thin boundary separating the shocked solar wind plasma from the magnetospheric plasmas,and it is also the boundary of the solar wind energy transport to the magnetosphere.Soft X-ray imaging ... Earth’s magnetopause is a thin boundary separating the shocked solar wind plasma from the magnetospheric plasmas,and it is also the boundary of the solar wind energy transport to the magnetosphere.Soft X-ray imaging allows investigation of the large-scale magnetopause by providing a two-dimensional(2-D)global view from a satellite.By performing 3-D global hybrid-particle-in-cell(hybrid-PIC)simulations,we obtain soft X-ray images of Earth’s magnetopause under different solar wind conditions,such as different plasma densities and directions of the southward interplanetary magnetic field.In all cases,magnetic reconnection occurs at low latitude magnetopause.The soft X-ray images observed by a hypothetical satellite are shown,with all of the following identified:the boundary of the magnetopause,the cusps,and the magnetosheath.Local X-ray emissivity in the magnetosheath is characterized by large amplitude fluctuations(up to 160%);however,the maximum line-of-sight-integrated X-ray intensity matches the tangent directions of the magnetopause well,indicating that these fluctuations have limited impact on identifying the magnetopause boundary in the X-ray images.Moreover,the magnetopause boundary can be identified using multiple viewing geometries.We also find that solar wind conditions have little effect on the magnetopause identification.The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission will provide X-ray images of the magnetopause for the first time,and our global hybrid-PIC simulation results can help better understand the 2-D X-ray images of the magnetopause from a 3-D perspective,with particle kinetic effects considered. 展开更多
关键词 MAGNETOPAUSE X-ray emissivity X-ray imaging SMILE global hybrid-PIC simulation
下载PDF
The Soft X-ray Imager(SXI)on the SMILE Mission 被引量:4
12
作者 S.Sembay A.L.Alme +83 位作者 D.Agnolon T.Arnold A.Beardmore A.Belén Balado Margeli C.Bicknell C.Bouldin G.Branduardi-Raymont T.Crawford J.P.Breuer T.Buggey G.Butcher R.Canchal J.A.Carter A.Cheney Y.Collado-Vega H.Connor T.Crawford N.Eaton C.Feldman C.Forsyth T.Frantzen G.Galgóczi J.Garcia G.Y.Genov C.Gordillo H-P.Gröbelbauer M.Guedel Y.Guo M.Hailey D.Hall R.Hampson J.Hasiba O.Hetherington A.Holland S-Y.Hsieh M.W.J.Hubbard H.Jeszenszky M.Jones T.Kennedy K.Koch-Mehrin S.Kögl S.Krucker K.D.Kuntz C.Lakin G.Laky O.Lylund A.Martindale J.Miguel Mas Hesse R.Nakamura K.Oksavik N.Østgaard H.Ottacher R.Ottensamer C.Pagani S.Parsons P.Patel J.Pearson G.Peikert F.S.Porter T.Pouliantis B.H.Qureshi W.Raab G.Randal A.M.Read N.M.M.Roque M.E.Rostad C.Runciman S.Sachdev A.Samsonov M.Soman D.Sibeck S.Smit J.Søndergaard R.Speight S.Stavland M.Steller TianRan Sun J.Thornhill W.Thomas K.Ullaland B.Walsh D.Walton C.Wang S.Yang 《Earth and Planetary Physics》 EI CSCD 2024年第1期5-14,共10页
The Soft X-ray Imager(SXI)is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission.SMILE is a joint science mission between the European Space Agency(ESA)and the Chinese... The Soft X-ray Imager(SXI)is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission.SMILE is a joint science mission between the European Space Agency(ESA)and the Chinese Academy of Sciences(CAS)and is due for launch in 2025.SXI is a compact X-ray telescope with a wide field-of-view(FOV)capable of encompassing large portions of Earth’s magnetosphere from the vantage point of the SMILE orbit.SXI is sensitive to the soft X-rays produced by the Solar Wind Charge eXchange(SWCX)process produced when heavy ions of solar wind origin interact with neutral particles in Earth’s exosphere.SWCX provides a mechanism for boundary detection within the magnetosphere,such as the position of Earth’s magnetopause,because the solar wind heavy ions have a very low density in regions of closed magnetic field lines.The sensitivity of the SXI is such that it can potentially track movements of the magnetopause on timescales of a few minutes and the orbit of SMILE will enable such movements to be tracked for segments lasting many hours.SXI is led by the University of Leicester in the United Kingdom(UK)with collaborating organisations on hardware,software and science support within the UK,Europe,China and the United States. 展开更多
关键词 Soft X-ray Imaging micropore optics large area CCD
下载PDF
Two methods for separating the magnetospheric solar wind charge exchange soft X-ray emission from the diffuse X-ray background 被引量:2
13
作者 YingJie Zhang TianRan Sun +5 位作者 JenniferACarter WenHao Liu Steve Sembay ShuiNai Zhang Li Ji Chi Wang 《Earth and Planetary Physics》 EI CSCD 2024年第1期119-132,共14页
Solar wind charge exchange(SWCX)is the process of solar wind high-valence ions exchanging charges with neutral components and generating soft X-rays.Recently,detecting the SWCX emission from the magnetosphere is propo... Solar wind charge exchange(SWCX)is the process of solar wind high-valence ions exchanging charges with neutral components and generating soft X-rays.Recently,detecting the SWCX emission from the magnetosphere is proposed as a new technique to study the magnetosphere using panoramic soft X-ray imaging.To better prepare for the data analysis of upcoming magnetospheric soft X-ray imaging missions,this paper compares the magnetospheric SWCX emission obtained by two methods in an XMM-Newton observation,during which the solar wind changed dramatically.The two methods differ in the data used to fit the diffuse X-ray background(DXB)parameters in spectral analysis.The method adding data from the ROSAT All-Sky Survey(RASS)is called the RASS method.The method using the quiet observation data is called the Quiet method,where quiet observations usually refer to observations made by the same satellite with the same target but under weaker solar wind conditions.Results show that the spectral compositions of magnetospheric SWCX emission obtained by the two methods are very similar,and the changes in intensity over time are highly consistent,although the intensity obtained by the RASS method is about 2.68±0.56 keV cm^(-2)s^(-1)sr^(-1)higher than that obtained by the Quiet method.Since the DXB intensity obtained by the RASS method is about 2.84±0.74 keV cm^(-2)s^(-1)sr^(-1)lower than that obtained by the Quiet method,and the linear correlation coefficient between the difference of SWCX and DXB obtained by the two methods in diffe rent energy band is close to-1,the diffe rences in magnetospheric SWCX can be fully attributed to the diffe rences in the fitted DXB.The difference between the two methods is most significant when the energy is less than 0.7 keV,which is also the main energy band of SWCX emission.In addition,the difference between the two methods is not related to the SWCX intensity and,to some extent,to solar wind conditions,because SWCX intensity typically va ries with the solar wind.In summary,both methods are robust and reliable,and should be considered based on the best available options. 展开更多
关键词 solar wind charge exchange(SWCX) ROSAT All-Sky Survey(RASS) soft X-ray X-ray imaging MAGNETOSPHERE
下载PDF
Exploring battery material failure mechanisms through synchrotron X-ray characterization techniques 被引量:1
14
作者 Lingzhe Fang Xiaozhao Liu Tao Li 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第7期128-135,共8页
Rechargeable battery cycling performance and related safety have been persistent concerns.It is crucial to decipher the capacity fading induced by electrode material failure via a range of techniques.Among these,synch... Rechargeable battery cycling performance and related safety have been persistent concerns.It is crucial to decipher the capacity fading induced by electrode material failure via a range of techniques.Among these,synchrotron-based X-ray techniques with high flux and brightness play a key role in understanding degradation mechanisms.In this comprehensive review,we summarize recent advancements in degra-dation modes and mechanisms that were revealed by synchrotron X-ray methodologies.Subsequently,an overview of X-ray absorption spectroscopy and X-ray scattering techniques is introduced for charac-terizing failure phenomena at local coordination atomic environment and long-range order crystal struc-ture scale,respectively.At last,we envision the future of exploring material failure mechanism. 展开更多
关键词 Battery failure Synchrotron-based techniques X-ray scattering X-ray absorption spectroscopy
下载PDF
Tomographic reconstruction of the Earth’s magnetosheath from multiple spacecraft:a theoretical study 被引量:2
15
作者 A.M.Jorgensen TianRan Sun +4 位作者 Y.Huang L.Li R.Xu L.Dai Chi Wang 《Earth and Planetary Physics》 EI CSCD 2024年第1期204-214,共11页
Following our earlier work on tomographic reconstruction of the magnetosheath soft X-ray emissions with superposed epoch analysis of many images recorded from a single spacecraft we now explore the instantaneous recon... Following our earlier work on tomographic reconstruction of the magnetosheath soft X-ray emissions with superposed epoch analysis of many images recorded from a single spacecraft we now explore the instantaneous reconstruction of the magnetosheath and magnetopause using a few images recorded simultaneously from a few spacecraft.This work is motivated by the prospect of possibly having two or three soft X-ray imagers in space in the coming years,and that many phenomena which occur at the magnetopause boundary,such as reconnection events and pressure pulse responses,do not lend themselves as well to superposed epoch analysis.If the reconstruction is successful-which we demonstrate in this paper that it can be-this collection of imagers can be used to reconstruct the magnetosheath and magnetopause from a single image from each spacecraft,allowing for high time resolution reconstructions.In this paper we explore the reconstruction using,two,three,and four spacecraft.We show that the location of the subsolar point of the magnetopause can be determined with just two satellites,and that volume emissions of soft X-rays,and the shape of the boundary,can be reconstructed using three or more satellites. 展开更多
关键词 MAGNETOSHEATH TOMOGRAPHY soft X-ray imaging SMILE
下载PDF
The CCD instrument background of the SMILE SXI 被引量:2
16
作者 M.W.J.Hubbard O.Hetherington +6 位作者 D.J.Hall T.W.Buggey S.Parsons T.Arnold A.Holland C.Pagani S.Sembay 《Earth and Planetary Physics》 EI CSCD 2024年第1期15-24,共10页
The ESA and CAS SMILE mission orbit is highly elliptical and will pass through multiple radiation environments.The Soft X-ray Imager(SXI)instrument aboard has a radiation shutter door designed to close when the surrou... The ESA and CAS SMILE mission orbit is highly elliptical and will pass through multiple radiation environments.The Soft X-ray Imager(SXI)instrument aboard has a radiation shutter door designed to close when the surrounding radiation flux is high.The shutter door will close when passing below an altitude threshold to protect against trapped particles in the Earth’s Van Allen Belts.Therefore,two radiation environments can be approximated based on the shutter door position:open and closed.The instrument background for the CCDs(Charge-Coupled Devices)that form the focal plane array of the SXI were evaluated for the two environments.Due to the correlation of the space environment with the solar cycle,the solar minima and maxima,the background was also evaluated at these two extremes.The results demonstrated that the highest instrument background will occur during solar minima due to the main contributing source being Galactic Cosmic Rays(GCRs).It was also found that the open background was highest for solar minima and that the closed background was highest during solar maxima.This is due to the radiation shutter door acting as a scattering centre and the changes in the energy flux distribution of the GCRs between the two solar extremes. 展开更多
关键词 instrument background X-ray astronomy space radiation
下载PDF
Jet formation and penetration performance of a double-layer charge liner with chemically-deposited tungsten as the inner liner 被引量:2
17
作者 Bihui Hong Wenbin Li +2 位作者 Yiming Li Zhiwei Guo Binyou Yan 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第3期374-385,共12页
This paper proposes a type of double-layer charge liner fabricated using chemical vapor deposition(CVD)that has tungsten as its inner liner.The feasibility of this design was evaluated through penetration tests.Double... This paper proposes a type of double-layer charge liner fabricated using chemical vapor deposition(CVD)that has tungsten as its inner liner.The feasibility of this design was evaluated through penetration tests.Double-layer charge liners were fabricated by using CVD to deposit tungsten layers on the inner surfaces of pure T2 copper liners.The microstructures of the tungsten layers were analyzed using a scanning electron microscope(SEM).The feasibility analysis was carried out by pulsed X-rays,slug-retrieval test and static penetration tests.The shaped charge jet forming and penetration law of inner tungsten-coated double-layer liner were studied by numerical simulation method.The results showed that the double-layer liners could form well-shaped jets.The errors between the X-ray test results and the numerical results were within 11.07%.A slug-retrieval test was found that the retrieved slug was similar to a numerically simulated slug.Compared with the traditional pure copper shaped charge jet,the penetration depth of the double-layer shaped charge liner increased by 11.4% and>10.8% respectively.In summary,the test results are good,and the numerical simulation is in good agreement with the test,which verified the feasibility of using the CVD method to fabricate double-layer charge liners with a high-density and high-strength refractory metal as the inner liner. 展开更多
关键词 Shaped charge Chemical vapor deposition TUNGSTEN Double-layer charge liner X-ray PENETRATION
下载PDF
Finding the magnetopause location using soft X-ray observations and a statistical inverse method 被引量:1
18
作者 Gonzalo Cucho-Padin Hyunju Connor +2 位作者 Jaewoong Jung Brian Walsh David G.Sibeck 《Earth and Planetary Physics》 EI CSCD 2024年第1期184-203,共20页
Variability in the location and shape of the dayside magnetopause is attributed to magnetic reconnection,a fundamental process that enables the transfer of mass,energy,and momentum from the solar wind into the magneto... Variability in the location and shape of the dayside magnetopause is attributed to magnetic reconnection,a fundamental process that enables the transfer of mass,energy,and momentum from the solar wind into the magnetosphere.The spatial and temporal properties of the magnetopause,under varying solar and magnetospheric conditions,remain largely unknown because empirical studies using in-situ observations are challenging to interpret.Global wide field-of-view(FOV)imaging is the only means to simultaneously observe the spatial distribution of the plasma properties over the vast dayside magnetospheric region and,subsequently,quantify the energy transport from the interplanetary medium into the terrestrial magnetosphere.Two upcoming missions,ESA/CAS SMILE and NASA’s LEXI will provide wide-field imagery of the dayside magnetosheath in soft X-rays,an emission generated by charge exchange interactions between high charge-state heavy ions of solar wind origin and exospheric neutral atoms.High-cadence two-dimensional observations of the magnetosheath will allow the estimation of dynamic properties of its inner boundary,the magnetopause,and enable studies of its response to changes in the solar wind dynamic pressure and interplanetary magnetic field orientation.This work introduces a statistically-based estimation approach based on inverse theory to estimate the spatial distribution of magnetosheath soft X-ray emissivities and,with this,identify the location of the magnetopause over the Sun−Earth line.To do so,we simulate the magnetosheath structure using the MHD-based OpenGGCM model and generate synthetic soft X-ray images using LEXI’s orbit and attitude information.Our results show that 3-D estimations using the described statistically-based technique are robust against Poisson-distributed shot noise inherent to soft X-ray images.Also,our proposed methodology shows that the accuracy of both three-dimensional(3-D)estimation and the magnetopause standoff distance calculation highly depends on the observational point. 展开更多
关键词 MAGNETOPAUSE soft X-ray TOMOGRAPHY
下载PDF
Preface to the Special Issue on Modeling and Data Analysis Methods for the SMILE mission 被引量:1
19
作者 TianRan Sun Hyunju Connor Andrey Samsonov 《Earth and Planetary Physics》 EI CSCD 2024年第1期1-4,共4页
The SMILE(Solar wind Magnetosphere Ionosphere Link Explorer)project(http://www.nssc.cas.cn/smile/,https://www.cosmos.esa.int/web/smile/mission)is a joint spacecraft mission of the European Space Agency(ESA)and the Chi... The SMILE(Solar wind Magnetosphere Ionosphere Link Explorer)project(http://www.nssc.cas.cn/smile/,https://www.cosmos.esa.int/web/smile/mission)is a joint spacecraft mission of the European Space Agency(ESA)and the Chinese Academy of Sciences(CAS)with an expected launch in 2025.SMILE aims to study the global interactions of solar wind–magnetosphere–ionosphere innovatively by imaging the Earth’s magnetosheath and cusps in soft X-rays and the northern auroral region in ultraviolet(UV)while simultaneously measuring plasma and magnetic field parameters in the solar wind and magnetosheath along a highly-elliptical and highly-inclined orbit.This special issue is composed of 22 articles,presenting recent progress in modeling and data analysis techniques developed for the SMILE mission.In this preface,we categorize the articles into the following seven topics and provide brief summaries:(1)instrument descriptions of the Soft X-ray Imager(SXI),(2)numerical modeling of the X-ray signals,(3)data processing of the X-ray images,(4)boundary tracing methods from the simulated images,(5)physical phenomena and a mission concept related to the scientific goals of SMILE-SXI,(6)studies of the aurora,and(7)ground-based support for SMILE. 展开更多
关键词 SMILE X-ray imaging MAGNETOSPHERE auroral IONOSPHERE
下载PDF
Estimating the subsolar magnetopause position from soft X-ray images using a low-pass image filter 被引量:1
20
作者 Hyangpyo Kim Hyunju K.Connor +9 位作者 Jaewoong Jung Brian M.Walsh David Sibeck Kip D.Kuntz Frederick S.Porter Catriana K.Paw U Rousseau A.Nutter Ramiz Qudsi Rumi Nakamura Michael Collier 《Earth and Planetary Physics》 EI CSCD 2024年第1期173-183,共11页
The Lunar Environment heliospheric X-ray Imager(LEXI)and Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)missions will image the Earth’s dayside magneto pause and cusps in soft X-rays after their respective l... The Lunar Environment heliospheric X-ray Imager(LEXI)and Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)missions will image the Earth’s dayside magneto pause and cusps in soft X-rays after their respective launches in the near future,to specify glo bal magnetic reconnection modes for varying solar wind conditions.To suppo rt the success of these scientific missions,it is critical to develop techniques that extract the magnetopause locations from the observed soft X-ray images.In this research,we introduce a new geometric equation that calculates the subsolar magnetopause position(RS)from a satellite position,the look direction of the instrument,and the angle at which the X-ray emission is maximized.Two assumptions are used in this method:(1)The look direction where soft X-ray emissions are maximized lies tangent to the magnetopause,and(2)the magnetopause surface near the subsolar point is almost spherical and thus RSis nea rly equal to the radius of the magneto pause curvature.We create synthetic soft X-ray images by using the Open Geospace General Circulation Model(OpenGGCM)global magnetohydrodynamic model,the galactic background,the instrument point spread function,and Poisson noise.We then apply the fast Fourier transform and Gaussian low-pass filte rs to the synthetic images to re move noise and obtain accurate look angles for the soft X-ray pea ks.From the filte red images,we calculate RS and its accuracy for different LEXI locations,look directions,and solar wind densities by using the OpenGGCM subsolar magnetopause location as ground truth.Our method estimates RS with an accuracy of<0.3 RE when the solar wind density exceeds>10 cm-3.The accuracy improves for greater solar wind densities and during southward interplanetary magnetic fields.The method ca ptures the magnetopause motion during southwa rd interplaneta ry magnetic field turnings.Consequently,the technique will enable quantitative analysis of the magnetopause motion and help reveal the dayside reconnection modes for dynamic solar wind conditions.This technique will suppo rt the LEXI and SMILE missions in achieving their scientific o bjectives. 展开更多
关键词 soft X-ray MAGNETOPAUSE RECONNECTION low-pass filter LEXI SMILE
下载PDF
上一页 1 2 215 下一页 到第
使用帮助 返回顶部