Linear vibration table can provide harmonic accelerations to excite the nonlinear error terms of Pendulous Integrating Gyro Accelerometer(PIGA).Integral precession calibration method is proposed to calibrate PIGA on a...Linear vibration table can provide harmonic accelerations to excite the nonlinear error terms of Pendulous Integrating Gyro Accelerometer(PIGA).Integral precession calibration method is proposed to calibrate PIGA on a linear vibration table in this paper.Based on the precise expressions of PIGA’s inputs,the error calibration model of PIGA is established.Precession angular velocity errors of PIGA are suppressed by integer periodic precession and the errors caused by non-integer periods vibrating are compensated.The complete calibration process,including planning,preparation,PIGA testing,and coefficient identification,is designed to optimize the test operations and evaluate the calibration results.The effect of the main errors on calibration uncertainty is analyzed and the relative sensitivity function is proposed to further optimize the test positions.Experimental and simulation results verify that the proposed 10-position calibration method can improve calibration uncertainties after compensating for the related errors.The order of calibration uncertainties of the second-and third-order coefficients are decreased to 10^(-8)(rad.s^(-1))/g^(2)and 10^(-8)(rad.s^(-1))/g3,respectively.Compared with the other two classical calibration methods,the calibration uncertainties of PIGA’s nonlinear error coefficients can be effectively reduced and the proportional residual errors are decreased less than 3×10-6(rad.s^(-1))/g by using the proposed calibration method.展开更多
Negative stiffness mechanisms can improve low-frequency vibration isolation performance and have been widely used in the vibration isolation of precision equipment. However, the negative stiffness mechanism usually in...Negative stiffness mechanisms can improve low-frequency vibration isolation performance and have been widely used in the vibration isolation of precision equipment. However, the negative stiffness mechanism usually introduces a nonlinear stiffness,resulting in a nonlinear response and worsening the vibration isolation performance, especially under large amplitude vibration.In this paper, an electromagnetic spring with linear negative stiffness(ESLNS) is proposed, in which the antagonistic ampere forces of the energized coils are used to generate negative stiffness within a long linear stroke. The magnetic field distribution is improved through the design of the magnetic circuit, thereby increasing the stiffness generation efficiency. The stiffness can be adjusted bidirectionally by current within the range of positive and negative stiffness. An electromagnetic stiffness model was established based on the equivalent magnetic circuit method. Experimental measurements verified the accuracy of the model and proved the linearity of the electromagnetic spring. A vibration isolator with high static and low dynamic stiffness(HSLDS) based on the ESLNS is designed and tested. The experimental results prove that the introduction of the ESLNS can effectively expand the isolation frequency band without changing the equilibrium position. Moreover, the vibration isolator with ESLNS does not produce nonlinear response. The proposed electromagnetic spring with linear negative stiffness extends the application range of HSLDS isolators to a large amplitude vibration environment.展开更多
文摘Linear vibration table can provide harmonic accelerations to excite the nonlinear error terms of Pendulous Integrating Gyro Accelerometer(PIGA).Integral precession calibration method is proposed to calibrate PIGA on a linear vibration table in this paper.Based on the precise expressions of PIGA’s inputs,the error calibration model of PIGA is established.Precession angular velocity errors of PIGA are suppressed by integer periodic precession and the errors caused by non-integer periods vibrating are compensated.The complete calibration process,including planning,preparation,PIGA testing,and coefficient identification,is designed to optimize the test operations and evaluate the calibration results.The effect of the main errors on calibration uncertainty is analyzed and the relative sensitivity function is proposed to further optimize the test positions.Experimental and simulation results verify that the proposed 10-position calibration method can improve calibration uncertainties after compensating for the related errors.The order of calibration uncertainties of the second-and third-order coefficients are decreased to 10^(-8)(rad.s^(-1))/g^(2)and 10^(-8)(rad.s^(-1))/g3,respectively.Compared with the other two classical calibration methods,the calibration uncertainties of PIGA’s nonlinear error coefficients can be effectively reduced and the proportional residual errors are decreased less than 3×10-6(rad.s^(-1))/g by using the proposed calibration method.
基金supported by the National Natural Science Foundation of China(Grant Nos. 62325302, 62203076, 62103065)the China Postdoctoral Science Foundation(Grant No. 2021M700584)+1 种基金the Program of Shanghai Academic/Technology Research Leader(Grant No. 21XD1421400)the Natural Science Foundation of Chongqing, China(Grant No.cstc2020jcyj-zdxmX0014)。
文摘Negative stiffness mechanisms can improve low-frequency vibration isolation performance and have been widely used in the vibration isolation of precision equipment. However, the negative stiffness mechanism usually introduces a nonlinear stiffness,resulting in a nonlinear response and worsening the vibration isolation performance, especially under large amplitude vibration.In this paper, an electromagnetic spring with linear negative stiffness(ESLNS) is proposed, in which the antagonistic ampere forces of the energized coils are used to generate negative stiffness within a long linear stroke. The magnetic field distribution is improved through the design of the magnetic circuit, thereby increasing the stiffness generation efficiency. The stiffness can be adjusted bidirectionally by current within the range of positive and negative stiffness. An electromagnetic stiffness model was established based on the equivalent magnetic circuit method. Experimental measurements verified the accuracy of the model and proved the linearity of the electromagnetic spring. A vibration isolator with high static and low dynamic stiffness(HSLDS) based on the ESLNS is designed and tested. The experimental results prove that the introduction of the ESLNS can effectively expand the isolation frequency band without changing the equilibrium position. Moreover, the vibration isolator with ESLNS does not produce nonlinear response. The proposed electromagnetic spring with linear negative stiffness extends the application range of HSLDS isolators to a large amplitude vibration environment.