期刊文献+
共找到481篇文章
< 1 2 25 >
每页显示 20 50 100
Diagnosing ratio of electron density to collision frequency of plasma surrounding scaled model in a shock tube using low-frequency alternating magnetic field phase shift
1
作者 吴明兴 谢楷 +3 位作者 刘艳 徐晗 张宝 田得阳 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期519-530,共12页
A non-contact low-frequency(LF)method of diagnosing the plasma surrounding a scaled model in a shock tube is proposed.This method utilizes the phase shift occurring after the transmission of an LF alternating magnetic... A non-contact low-frequency(LF)method of diagnosing the plasma surrounding a scaled model in a shock tube is proposed.This method utilizes the phase shift occurring after the transmission of an LF alternating magnetic field through the plasma to directly measure the ratio of the plasma loop average electron density to collision frequency.An equivalent circuit model is used to analyze the relationship of the phase shift of the magnetic field component of LF electromagnetic waves with the plasma electron density and collision frequency.The applicable range of the LF method on a given plasma scale is analyzed.The upper diagnostic limit for the ratio of the electron density(unit:m^(-3))to collision frequency(unit:Hz)exceeds 1×10^(11),enabling an electron density to exceed 1×10^(20)m^(-3)and a collision frequency to be less than 1 GHz.In this work,the feasibility of using the LF phase shift to implement the plasma diagnosis is also assessed.Diagnosis experiments on shock tube equipment are conducted by using both the electrostatic probe method and LF method.By comparing the diagnostic results of the two methods,the inversion results are relatively consistent with each other,thereby preliminarily verifying the feasibility of the LF method.The ratio of the electron density to the collision frequency has a relatively uniform distribution during the plasma stabilization.The LF diagnostic path is a loop around the model,which is suitable for diagnosing the plasma that surrounds the model.Finally,the causes of diagnostic discrepancy between the two methods are analyzed.The proposed method provides a new avenue for diagnosing high-density enveloping plasma. 展开更多
关键词 low-frequency alternating magnetic field phase shift shock-tube plasma diagnosis electron density collision frequency
下载PDF
Acetaminophen overdose-induced acute liver injury can be alleviated by static magnetic field
2
作者 Han-Xiao Chen Xin-Yu Wang +11 位作者 Biao Yu Chuan-Lin Feng Guo-Feng Cheng Lei Zhang Jun-Jun Wang Ying Wang Ruo-Wen Guo Xin-Miao Ji Wen-Jing Xie Wei-Li Chen Chao Song Xin Zhang 《Zoological Research》 SCIE CSCD 2024年第3期478-490,共13页
Acetaminophen(APAP),the most frequently used mild analgesic and antipyretic drug worldwide,is implicated in causing 46%of all acute liver failures in the USA and between 40%and 70%in Europe.The predominant pharmacolog... Acetaminophen(APAP),the most frequently used mild analgesic and antipyretic drug worldwide,is implicated in causing 46%of all acute liver failures in the USA and between 40%and 70%in Europe.The predominant pharmacological intervention approved for mitigating such overdose is the antioxidant N-acetylcysteine(NAC);however,its efficacy is limited in cases of advanced liver injury or when administered at a late stage.In the current study,we discovered that treatment with a moderate intensity static magnetic field(SMF)notably reduced the mortality rate in mice subjected to high-dose APAP from 40%to 0%,proving effective at both the initial liver injury stage and the subsequent recovery stage.During the early phase of liver injury,SMF markedly reduced APAPinduced oxidative stress,free radicals,and liver damage,resulting in a reduction in multiple oxidative stress markers and an increase in the antioxidant glutathione(GSH).During the later stage of liver recovery,application of vertically downward SMF increased DNA synthesis and hepatocyte proliferation.Moreover,the combination of NAC and SMF significantly mitigated liver damage induced by high-dose APAP and increased liver recovery,even 24 h post overdose,when the effectiveness of NAC alone substantially declines.Overall,this study provides a noninvasive non-pharmaceutical tool that offers dual benefits in the injury and repair stages following APAP overdose.Of note,this tool can work as an alternative to or in combination with NAC to prevent or minimize liver damage induced by APAP,and potentially other toxic overdoses. 展开更多
关键词 ACETAMINOPHEN Acute liver injury static magnetic fields Oxidative stress DNA synthesis
下载PDF
Determination of the Series Resistance of a Series Vertical-Junction Silicon (N+/P/P+) Solar Cell under Polychromatic Illumination and Magnetic Field: Effect of Optimum Thickness
3
作者 Dibor Faye Babou Dione +1 位作者 Mountaga Boiro Pape Diop 《Journal of Modern Physics》 2024年第10期1543-1554,共12页
By solving the magneto-transport equation for excess minority charge carriers in the base of the series vertical-junction silicon cell, the phenomenological parameters of the cell can be determined from the boundary c... By solving the magneto-transport equation for excess minority charge carriers in the base of the series vertical-junction silicon cell, the phenomenological parameters of the cell can be determined from the boundary conditions. Photocurrent density and photovoltage are determined for each value of applied magnetic field and corresponding optimum thickness, to establish the current-voltage characteristic (Jph(Sf, Sb, z, B, Hop)-Vph(Sf, Sb, z, B, Hop) of the silicon cell under polychromatic illumination. This study will make it possible to reduce the material used (by reducing the optimum thickness), which will help to lower prices. It will also enable us to reduce betting effects (lower series resistance), thereby boosting solar cell efficiency. 展开更多
关键词 Series Vertical Junction Silicon Cell static Regime magnetic field Optimum Thickness Series Resistance
下载PDF
Effects of gradient high-field static magnetic fields on diabetic mice 被引量:5
4
作者 Biao Yu Chao Song +11 位作者 Chuan-Lin Feng Jing Zhang Ying Wang Yi-Ming Zhu Lei Zhang Xin-Miao Ji Xiao-Fei Tian Guo-Feng Cheng Wei-Li Chen Vitalii Zablotskii Hua Wang Xin Zhang 《Zoological Research》 SCIE CAS CSCD 2023年第2期249-258,共10页
Although 9.4 T magnetic resonance imaging(MRI) has been tested in healthy volunteers,its safety in diabetic patients is unclear.Furthermore,the effects of high static magnetic fields(SMFs),especially gradient vs.unifo... Although 9.4 T magnetic resonance imaging(MRI) has been tested in healthy volunteers,its safety in diabetic patients is unclear.Furthermore,the effects of high static magnetic fields(SMFs),especially gradient vs.uniform fields,have not been investigated in diabetics.Here,we investigated the consequences of exposure to 1.0-9.4 T high SMFs of different gradients(>10 T/m vs.0-10 T/m)on type 1 diabetic(T1D) and type 2 diabetic(T2D) mice.We found that 14 h of prolonged treatment of gradient(as high as 55.5 T/m) high SMFs(1.0-8.6 T) had negative effects on T1D and T2D mice,including spleen,hepatic,and renal tissue impairment and elevated glycosylated serum protein,blood glucose,inflammation,and anxiety,while 9.4 T quasi-uniform SMFs at 0-10 T/m did not induce the same effects.In regular T1D mice(blood glucose>16.7 mmol/L),the>10 T/m gradient high SMFs increased malondialdehyde(P<0.01) and decreased superoxide dismutase(P<0.05).However,in the severe T1D mice(blood glucose≥30.0 mmol/L),the>10 T/m gradient high SMFs significantly increased tissue damage and reduced survival rate.In vitro cellular studies showed that gradient high SMFs increased cellular reactive oxygen species and apoptosis and reduced MS-1 cell number and proliferation.Therefore,this study showed that prolonged exposure to high-field(1.0-8.6 T)>10 T/m gradient SMFs(35-1 380 times higher than that of current clinical MRI)can have negative effects on diabetic mice,especially mice with severe T1D,whereas 9.4 T high SMFs at 0-10T/m did not produce the same effects,providing important information for the future development and clinical application of SMFs,especially high-field MRI. 展开更多
关键词 Type 2 diabetes Type 1 diabetes magnetic resonance imaging(MRI) Gradient static magnetic field Quasi-uniform static magnetic field
下载PDF
Development of a low-frequency magnetic lightning mapping system(LFM-LMS)in North China:validation and preliminary results
5
作者 Xiao Li GaoPeng Lu +3 位作者 FanChao Lyu HongBo Zhang Kainat Qamar RuBin Jiang 《Earth and Planetary Physics》 CAS CSCD 2023年第4期460-470,共11页
A low-frequency magnetic lightning mapping system(LFM-LMS)was built during the SHAndong Triggered Lightning Experiment(SHATLE),based on continuous measurements of magnetic field radiation from lightning.The hardware a... A low-frequency magnetic lightning mapping system(LFM-LMS)was built during the SHAndong Triggered Lightning Experiment(SHATLE),based on continuous measurements of magnetic field radiation from lightning.The hardware and source-mapping techniques used by the LFM-LMS were introduced;both Monte Carlo simulations and the observation of rocket-triggered lightning examples were employed to examine the location accuracy and detection effectiveness of the LFM-LMS.We estimated that the system’s location accuracy about 100−200 m horizontally and~200 m vertically.A natural intra-cloud lightning flash and a rocket-triggered lightning flash,both with intricate structures and discharging processes,were examined using the three-dimensional mapping results.The progressing path of negative lightning leaders is usually well-defined,and its propagation speed is estimated to be(0.5−1.4)×10^(6)m/s.In summary,the LFM-LMS can reconstruct the three-dimensional morphology of lightning flashes;this technology provides a efficient method for investigating the characteristics of lightning development,as well as the overall electrical strucuture of thunderstorms. 展开更多
关键词 rocket-triggered lightning low-frequency magnetic field lightning mapping observation location accuracy
下载PDF
Design Optimization for Generating a High Static Magnetic Field
6
作者 Hussien A. Elharati Salma Ahmed Alharati +1 位作者 Ziad Omar Wareg Mohamed Amro Waregh 《World Journal of Engineering and Technology》 2023年第4期793-806,共14页
This paper details the creation of a device capable of generating a powerful and consistent static magnetic field. This apparatus serves the purpose of quantifying the magnetostrictive strain found in materials like a... This paper details the creation of a device capable of generating a powerful and consistent static magnetic field. This apparatus serves the purpose of quantifying the magnetostrictive strain found in materials like annealed cobalt ferrite and Terfenol-D, specifically those shaped as cylindrical rods. In our investigation, the use of static magnetic fields proves most advantageous. This choice is made to mitigate the generation of eddy currents, which would inevitably occur if the magnetic field intensity were varied. The fundamental idea behind this design involves employing a C-shaped iron core constructed from low-carbon mild steel. On this core, three coils are mounted, each capable of producing one-third of the required 9000 Oersted (Oe) magnetic field strength. The test specimen is situated within the “jaws” of the C-shaped core, thus completing the magnetic circuit. To manage the heat generated by each coil, a cooling system consisting of copper tubes is employed. These tubes facilitate the flow of air to dissipate the heat. To model and predict the magnetic field strength produced by the coils, finite element analysis (FEMM) software is utilized, and the results align closely with the anticipated outcomes. This design effectively generates a robust and unchanging magnetic field measuring a stable 9000 Oe in total. Consequently, this equipment finds utility in characterizing the magnetic properties of specific materials. 展开更多
关键词 static magnetic field magnetostrictive Strain Eddy Currents magnetic field Strength Finite Element Method magnetics (FEMM)
下载PDF
THE INFLUENCE OF LOW-FREQUENCY VARYING MAGNETIC FIELDON THE PULSATILE FLOW IN A RIGID ROUND TUBE
7
作者 孙东宁 吴望一 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 1997年第2期121-127,共7页
In this paper, the analytic solution of the dynamical equation of the pulsatile flow in a rigid round tube under the low-frequency varying magnetic field is obtained. The velocity distribution and the flow impedance a... In this paper, the analytic solution of the dynamical equation of the pulsatile flow in a rigid round tube under the low-frequency varying magnetic field is obtained. The velocity distribution and the flow impedance are calculated. The results of e valuable for understanding the influence of low-frequency varying magnetic field on hemodynamics and its clinical application. 展开更多
关键词 low-frequency varying magnetic field pulsatile flow IMPEDANCE impedance ratio
下载PDF
Directional growth behavior of a(Al) dendrites during concentration-gradientcontrolled solidification process in static magnetic field 被引量:1
8
作者 李磊 徐博 +6 位作者 佟伟平 何立子 班春燕 张辉 左玉波 朱庆丰 崔建忠 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2015年第7期2438-2445,共8页
The large and small sized Cu(solid)/Al(liquid) couples were prepared to investigate the directional growth behavior of primary a(Al) phase during a concentration-gradient-controlled solidification process under ... The large and small sized Cu(solid)/Al(liquid) couples were prepared to investigate the directional growth behavior of primary a(Al) phase during a concentration-gradient-controlled solidification process under various static magnetic fields(SMFs).The results show that in the large couples,the α(Al) dendrites reveal a directional growth character whether without or with the SMF.However,the 12 T magnetic field induces regular growth,consistent deflection and the decrease of secondary arm spacing of the dendrites.In the small couples,the α(Al) dendrites still reveal a directional growth character to some extent with a SMF of ≤5 T.However,an 8.8 T SMF destroys the directional growth and induces severe random deflections of the dendrites.When the SMF increases to 12 T,the a(Al) dendrites become quite regular despite of the consistent deflection.The directional growth arises from the continuous long-range concentration gradient field built in the melt.The morphological modification is mainly related to the suppression of natural convections and the induction of thermoelectric magnetic convection by the SMF. 展开更多
关键词 α(Al) dendrite diffusion couple concentration gradient field static magnetic field directional growth thermoelectric magnetic convection
下载PDF
Effects of static magnetic fields on melt flow in detached solidification 被引量:3
9
作者 彭岚 龚欢 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2015年第3期936-943,共8页
A series of three-dimensional numerical computations were conducted to understand the effects of different static magnetic fields on thermal fluctuation and melt flow during the detached solidification of CdZnTe. Nume... A series of three-dimensional numerical computations were conducted to understand the effects of different static magnetic fields on thermal fluctuation and melt flow during the detached solidification of CdZnTe. Numerical calculations were carried out by three different configurations of magnetic field: without magnetic field, with an axial magnetic field (AMF) and with a cusp-shaped magnetic field (CMF). The results reveal that the magnetic fields can effectively suppress the melt flow and thermal fluctuation and the suppression effect of the AMF is stronger than that of the CMF. Besides, the physical mechanism of thermocapillary?buoyancy convection instability was discussed and the effects of magnetic field on the critical Marangoni number were also obtained. 展开更多
关键词 detached solidification static magnetic field thermocapillary-buoyancy convection numerical simulation CDZNTE
下载PDF
Direct Generation of Intense Compression Waves in Molten Metals by Using a High Static Magnetic Field and Their Application 被引量:5
10
作者 QiangWANG SATORUKAWAI 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2003年第1期5-9,共5页
Compression waves propagating through molten metals are contributed to degassing, accelerating reaction rate,removing exclusions from molten metals and refining solidification structures during metallurgical processin... Compression waves propagating through molten metals are contributed to degassing, accelerating reaction rate,removing exclusions from molten metals and refining solidification structures during metallurgical processing of materials. In the present study, two electromagnetic methods are proposed to generate intense compression wavesdirectly in liquid metals. One is the simultaneous imposition of a high frequency electrical current field and a staticmagnetic field; the other is that of a high frequency magnetic field and a static magnetic field. A mathematical modelbased on compressible fluid dynamics and electromagnetic fields theory has been developed to derive pressure distributions of the generated waves in a metal. It shows that the intensity of compression waves is proportional to thatof the high frequency electromagnetic force. And the frequency is the same as that of the imposed electromagneticforce. On the basis of theoretical analyses, pressure change in liquid gallium was examined by a pressure transducerunder various conditions. The observed results approximately agreed with the predictions derived from the theoreticalanalyses and calculations. Moreover, the effect of the generated waves on improvement of solidification structureswas also examined. It shows that the generated compression waves can refine solidification structures when they wereapplied to solidification process of Sn-Pb alloy. This study indicates a new method to generate compression wavesby imposing high frequency electromagnetic force locally on molten metals and this kind of compression waves canprobably overcome the difficulties when waves are excited by mechanical vibration in high temperature environments. 展开更多
关键词 High static magnetic field Compression wave Electromagnetic processing of materials Maeneto-hvdrodvnamics. Solidification process
下载PDF
Effects of static magnetic field on human umbilical vessel endothelial cell 被引量:5
11
作者 李飞 徐可为 +4 位作者 王海昌 郭文怡 憨勇 刘兵 张荣庆 《Journal of Medical Colleges of PLA(China)》 CAS 2007年第2期106-110,共5页
Objective: To investigate the effects of static magnetic field(SMF) on the viability, adhesion molecule expression of human umbilical vessel endothelial cell. Methods: Magnetic flux intensity was 0. 1 mT, 1 mT, 10 mT.... Objective: To investigate the effects of static magnetic field(SMF) on the viability, adhesion molecule expression of human umbilical vessel endothelial cell. Methods: Magnetic flux intensity was 0. 1 mT, 1 mT, 10 mT. Cell viability and proliferation were measured with 3H-TdR and MTT methods; and apoptosis of human umbilical vein endothelial cell (HUVEC) was studied by flow cytometry and transmission electric microscopy. ELISA was used to measure the expression of ICAM-1 and VCAM-1 on endothelium. Results: 0. 1 mT SMF had no effects on the growth of HUVEC. however,SMF of 1 mT, 10 mT attenuated growth of HUVEC. 10 mT static magnetic field could induce apoptosis and necrosis of HUVEC. 10 mT SMF enhanced the expression of ICAM-1 and VCAM-1 on endothelium. Conclusion: The effect of SMF depends on the intensity of SMF. 10 mT SMF has adverse effects on human umbilical vessel endothelial cell. 展开更多
关键词 static magnetic field ENDOTHELIUM PROLIFERATION APOPTOSIS adhesion molecule
下载PDF
Effects of 13 T Static Magnetic Fields (SMF) in the Cell Cycle Distribution and Cell Viability in Immortalized Hamster Cells and Human Primary Fibroblasts Cells 被引量:2
12
作者 赵国平 陈少鹏 +8 位作者 赵烨 朱玲燕 黄佩 鲍凌志 王军 王磊 吴李君 吴跃进 许安 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第1期123-128,共6页
Magnetic resonance image (MRI) systems with a much higher magnetic flux density were developed and applied for potential use in medical diagnostic. Recently, much attention has been paid to the biological effects of... Magnetic resonance image (MRI) systems with a much higher magnetic flux density were developed and applied for potential use in medical diagnostic. Recently, much attention has been paid to the biological effects of static, strong magnetic fields (SMF). With the 13 T SMF facility in the Institute of Plasma Physics, Chinese Academy of Sciences, the present study focused on the cellular effects of the SMF with 13 T on the cell viability and the cell cycle distribution in immortalized hamster cells, such as human-hamster hybrid (AL) cells, Chinese hamster ovary (CHO) cells, DNA double-strand break repair deficient mutant (XRS-5) cells, and human primary skin fibroblasts (AG1522) cells. It was found that the exposure of 13 T SMF had less effect on the colony formation in either nonsynchronized or synchronized AL cells. Moreover, as compared to non-exposed groups, there were slight differences in the cell cycle distribution no matter in either synchronized or nonsynchronized immortalized hamster ceils after exposure to 13 T SMF. However, it should be noted that the percentage of exposed AG1522 cells at G0/G1 phase was decreased by 10% as compared to the controls. Our data indicated that although 13 T SMF had minimal effects in immortalized hamster cells, the cell cycle distribution was slightly modified by SMF in human primary fibroblasts. 展开更多
关键词 static magnetic fields immortalized hamster cells human primary fibroblasts cells
下载PDF
Research on electromagnetic relay's dynamic characteristics disturbed by uniform static magnetic field 被引量:3
13
作者 Guo-fu ZHAI Qi-ya WANG Wan-bin REN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第4期577-582,共6页
Electromagnetic relay is a widely used apparatus which usually works in a magnetic disturbance environment. To evaluate its electromagnetic compatibility (EMC) in a static magnetic field, dynamic characteristics of a ... Electromagnetic relay is a widely used apparatus which usually works in a magnetic disturbance environment. To evaluate its electromagnetic compatibility (EMC) in a static magnetic field, dynamic characteristics of a clapper relay in a uniform static magnetic field situation based on the finite element method (FEM) is studied. Influences of the magnetic field on dynamic parameters (delay time, pick-up time, end pressure, and final velocity) as well as a situation in which the relay cannot function normally are analyzed. Simulation reveals that the external magnetic field which weakens the relay’s air-gap field has a greater influence on the relay’s dynamic parameters than the one strengthening the field. The validity of the simulation is verified by measured results of coil current and armature displacement. 展开更多
关键词 Dynamic characteristics Uniform static magnetic field Electromagnetic relay Finite element method (FEM) Electromagnetic compatibility (EMC)
下载PDF
Influence of Alternating and Static Magnetic Fields on Drug Release from Hybrid Hydrogels Containing Magnetic Nanoparticles 被引量:2
14
作者 Marianna Uva Daniela Pasqui +2 位作者 Lorenzo Mencuccini Serena Fedi Rolando Barbucci 《Journal of Biomaterials and Nanobiotechnology》 2014年第2期116-127,共12页
Hybrid hydrogels of carboxymethylcellulose (CMC), containing two different amounts of CoFe2O4 magnetic nanoparticles (50% and 70% in relation to the quantity of the polymer) as crosslinkers, were prepared. The hybrid ... Hybrid hydrogels of carboxymethylcellulose (CMC), containing two different amounts of CoFe2O4 magnetic nanoparticles (50% and 70% in relation to the quantity of the polymer) as crosslinkers, were prepared. The hybrid hydrogels were chemically and morphologically characterized and their viscoelastic properties and swelling degrees were analyzed. The hydrogels were tested as controlled drug delivery systems by applying one static and two different alternating magnetic fields. The application of the two alternating magnetic fields (AMF) to the hybrid hydrogels induced a higher release of methylene blue (MB), used as a model drug, than without the application of any magnetic field, especially at low frequency (4 Hz) and high magnetic intensity (0.5 T). In contrast, when the hybrid hydrogels were exposed to a static magnetic field (SMF) the release of MB was slowed down. Furthermore the two different amounts of magnetic nanoparticles induce different responses to the magnetic field. The greater number of nanoparticles in the CMC-NP-70 hydrogel leads to the formation of some NPs clusters limiting the drug release;conversely, the CMC-NP-50 hydrogel, containing a lower amount of nanoparticles, shows a higher release of MB vs. time. In conclusion, we were able to get a potential system for modulation of the drug delivery: the release behaviour of hybrid hydrogels can be modulated by applying alternating and static magnetic fields cyclically. A possible explanation for the release mechanism is about the structural modification of the polymeric chains that occurs when the hybrid hydrogels are exposed to the magnetic fields. 展开更多
关键词 magnetic HYDROGELS ALTERNATING magnetic field static magnetic field Controlled Release COBALT FERRITE Nanoparticles
下载PDF
The effects of a static magnetic field on the microwave absorption of hydrogen plasma in carbon nanotubes: a numerical study 被引量:1
15
作者 彭志华 龚学余 +2 位作者 彭延峰 郭燕春 宁艳桃 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第7期541-545,共5页
We theoretically investigate the microwave absorption properties of hydrogen plasma in iron-catalyzed high- pressure disproportionation-grown carbon nanotubes under an external static magnetic field in the frequency r... We theoretically investigate the microwave absorption properties of hydrogen plasma in iron-catalyzed high- pressure disproportionation-grown carbon nanotubes under an external static magnetic field in the frequency range 0.3 GHz to 30 GHz, using the Maxwell equations in conjunction with a general expression for the effective complex permittivity of magnetized plasma known as the Appleton Hartree formula. The effects of the external static magnetic field intensity and the incident microwave propagation direction on the microwave absorption of hydrogen plasma in CNTs are studied in detail. The numerical results indicate that the microwave absorption properties of hydrogen plasma in iron-catalyzed high-pressure disproportionation-grown carbon nanotubes can be obviously improved when the exter- nal static magnetic field is applied to the material. It is found that the specified frequency microwave can be strongly absorbed by the hydrogen plasma in iron-catalyzed high-pressure disproportionation-grown carbon nanotubes over a wide range of incidence angles by adjusting the external magnetic field intensity and the parameters of the hydrogen plasma. 展开更多
关键词 carbon nanotubes hydrogen plasma static magnetic field microwave absorption
下载PDF
Experimental study on freezing of liquids under static magnetic field 被引量:5
16
作者 Hongxia Zhao Feng Zhang +2 位作者 Hanqing Hu Sheng Liu Jitian Han 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2017年第9期1288-1293,共6页
Freezing processes of several liquids under static magnetic field(SMF) less than 50 mT were investigated. Central temperature of liquid samples held in glass test tubes immersed in a liquid bath was measured and colle... Freezing processes of several liquids under static magnetic field(SMF) less than 50 mT were investigated. Central temperature of liquid samples held in glass test tubes immersed in a liquid bath was measured and collected. Nucleation temperature and phase transition time were obtained from freezing curves. Normality tests were performed for nucleation temperature of these liquids with/without magnetic field and normality distributions were justified. Analysis of variances was carried out for nucleation temperature of these liquids with magnetic field flux density as the influencing factor. Results showed that no significant difference was found for deionized water with or without SMF. However, differences exist in 0.9% NaCl solution and 5% ethylene glycol solution with and without SMF. Nucleation temperature of 0.9% NaCl with SMF is lower than that without SMF, while its phase transition time is shorter than that without SMF. Nucleation temperature of 5% ethylene glycol with SMF is higher than that without SMF, while its phase transition time is not modified with SMF. 展开更多
关键词 Liquid Freezing static magnetic field Nucleation temperature Phase transition time
下载PDF
Effect of Static Magnetic Field on α-Amylase Activity and Enzymatic Reaction 被引量:1
17
作者 贾绍义 刘勇 +1 位作者 吴松海 王志斌 《Transactions of Tianjin University》 EI CAS 2009年第4期272-275,共4页
The effect of magnetic field on a-amylase was studied. Under the experimental conditions, a-amylase solution was treated by 0.15 T, 0.30 T and 0.45 T static magnetic fields for a known period of time, then the activit... The effect of magnetic field on a-amylase was studied. Under the experimental conditions, a-amylase solution was treated by 0.15 T, 0.30 T and 0.45 T static magnetic fields for a known period of time, then the activity, kinetic parameters, and the secondary conformation were investigated. The results showed that there was a considerable effect of the magnetic exposure on the α-amylase. The activity was increased by 27%, 34.1%, 37.8% compared with the control. It was also found that both kinetic parameters Km and Vm could be decreased due to the increasing magnetic field, Km decreased from 2.20×10^2 to 0.87×10^2, whereas Vm decreased from 2.0×10^3 g/min to 1.1 ×10^3 g/min. At the same time, there were some irregular changes in a-amylase secondary conformation. 展开更多
关键词 static magnetic field or-amylase ACTIVITY secondary conformation Michaelis constant
下载PDF
Static and 50 Hz Electromagnetic Fields Effects on Human Neuronal-Like Cells Vibration Bands in the Mid-Infrared Region 被引量:1
18
作者 Emanuele Calabrò Salvatore Condello +1 位作者 Salvatore Magazù Riccardo Ientile 《Journal of Electromagnetic Analysis and Applications》 2011年第2期69-78,共10页
Human neuronal-like cells were exposed to static and 50 Hz electromagnetic fields at the intensities of 2 mT and 1 mT, respectively. The effects of exposure were investigated in the mid-infrared region by means of Fou... Human neuronal-like cells were exposed to static and 50 Hz electromagnetic fields at the intensities of 2 mT and 1 mT, respectively. The effects of exposure were investigated in the mid-infrared region by means of Fourier self deconvolu-tion spectroscopic analysis. After exposure of 3 hours to static and 50 Hz electromagnetic fields, the vibration bands of CH2 methilene group increased significantly after both exposures, suggesting a relative increase of lipid related to conformational changes in the cell membrane due to electromagnetic fields. In addition, PO2- stretching phosphate bands decreased after both exposures, suggesting that alteration in DNA/RNA can be occurred. In particular, exposure of 3 hours to 50 Hz electromagnetic fields produced significant increases in β-sheet contents in amide I, and around the 1740 cm?1 band assigned to non-hydrogen-bonded ester carbonyl stretching mode, that can be related to unfolding processes of proteins structure and cells death. Further exposure up to 18 hours to static magnetic field produced an increase in β-sheet contents as to α-helix components of amide I region, as well. 展开更多
关键词 static magnetic field 50 HZ Electromagnetic field Neuronal-Like CELLS FTIR Spectroscopy
下载PDF
Characteristics of Transient Outward Potassium Channel Exposed to 3 mT Static Magnetic Field 被引量:1
19
作者 李刚 程立君 +3 位作者 乔晓艳 林凌 张璐 李媛媛 《Transactions of Tianjin University》 EI CAS 2009年第5期319-323,共5页
Acutely isolated mouse hippocampal CA3 pyramidal neurons were exposed to 3 mT static magnetic field,and the characteristics of transient outward K+ channel were studied using the whole-cell patch-clamp technique.The e... Acutely isolated mouse hippocampal CA3 pyramidal neurons were exposed to 3 mT static magnetic field,and the characteristics of transient outward K+ channel were studied using the whole-cell patch-clamp technique.The experiment revealed that the amplitude of transient outward potassium channel current was reduced.The maximum activated current densities of control group and exposure group were 163.62±20.68 pA/pF and 98.74±16.57 pA/pF(n=12,P<0.01) respectively.The static magnetic field exposure affected the activation and inactivation process of transient outward potassium channel current.Due to the magnetic field exposure,the half-activation voltage of the activation curves changed from 5.59±1.96 mV to 27.87±7.24 mV(n=12,P<0.05) ,and the slope factor changed from 19.43±2.11 mV to 25.87±4.22 mV(n=12,P<0.05) .The half-inactivation voltage of the inactivation curves also changed from-56.09±0.89 mV to-57.16±1.10 mV(n=12,P>0.05) and the slope factor of the inactivation curves from 8.69±0.80 mV to 10.87±1.02 mV(n=12,P<0.05) .The results show that the static magnetic field can change the characteristics of transient outward K+ channel,and affect the physiological functions of neurons. 展开更多
关键词 transient outward potassium channel current patch-clamp technique static magnetic field biological effect NEURONS
下载PDF
Efficacy of static magnetic field for pain of adjuvant arthritis rats 被引量:1
20
作者 Shigeyuki Kanai Norimasa Taniguchi 《Advances in Bioscience and Biotechnology》 2012年第4期511-515,共5页
Rats suffering from adjuvant arthritis (AA) were used to examine the effect of a static magnetic field (SMF) upon pain relief. Rats were divided into SMF- treated AA rats, non-SMF treated AA rats and control rats. Fol... Rats suffering from adjuvant arthritis (AA) were used to examine the effect of a static magnetic field (SMF) upon pain relief. Rats were divided into SMF- treated AA rats, non-SMF treated AA rats and control rats. Following SMF stimulation, we measured blood flow volume in the paw and then reactive speed response to thermal stimulation. The AA groups exhibited significantly lower blood volume and reactivity to thermal stimulation compared to the control group. Compared to non-SMF, SMF exhibited increased blood flow volume in both the tail and paw, along with an increased reactive speed response to thermal stimulation. Our findings suggest that an improved of blood flow and reactive speed response, induced by SMF, appears to be effective for the relief of pain induced by chronic inflammation. 展开更多
关键词 static magnetic field (Smf) ADJUVANT ARTHRITIS (Aa) BLOOD Flow REACTIVE Speed Response
下载PDF
上一页 1 2 25 下一页 到第
使用帮助 返回顶部