期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Diagnosing ratio of electron density to collision frequency of plasma surrounding scaled model in a shock tube using low-frequency alternating magnetic field phase shift
1
作者 吴明兴 谢楷 +3 位作者 刘艳 徐晗 张宝 田得阳 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期519-530,共12页
A non-contact low-frequency(LF)method of diagnosing the plasma surrounding a scaled model in a shock tube is proposed.This method utilizes the phase shift occurring after the transmission of an LF alternating magnetic... A non-contact low-frequency(LF)method of diagnosing the plasma surrounding a scaled model in a shock tube is proposed.This method utilizes the phase shift occurring after the transmission of an LF alternating magnetic field through the plasma to directly measure the ratio of the plasma loop average electron density to collision frequency.An equivalent circuit model is used to analyze the relationship of the phase shift of the magnetic field component of LF electromagnetic waves with the plasma electron density and collision frequency.The applicable range of the LF method on a given plasma scale is analyzed.The upper diagnostic limit for the ratio of the electron density(unit:m^(-3))to collision frequency(unit:Hz)exceeds 1×10^(11),enabling an electron density to exceed 1×10^(20)m^(-3)and a collision frequency to be less than 1 GHz.In this work,the feasibility of using the LF phase shift to implement the plasma diagnosis is also assessed.Diagnosis experiments on shock tube equipment are conducted by using both the electrostatic probe method and LF method.By comparing the diagnostic results of the two methods,the inversion results are relatively consistent with each other,thereby preliminarily verifying the feasibility of the LF method.The ratio of the electron density to the collision frequency has a relatively uniform distribution during the plasma stabilization.The LF diagnostic path is a loop around the model,which is suitable for diagnosing the plasma that surrounds the model.Finally,the causes of diagnostic discrepancy between the two methods are analyzed.The proposed method provides a new avenue for diagnosing high-density enveloping plasma. 展开更多
关键词 low-frequency alternating magnetic field phase shift shock-tube plasma diagnosis electron density collision frequency
下载PDF
THE INFLUENCE OF LOW-FREQUENCY VARYING MAGNETIC FIELDON THE PULSATILE FLOW IN A RIGID ROUND TUBE
2
作者 孙东宁 吴望一 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 1997年第2期121-127,共7页
In this paper, the analytic solution of the dynamical equation of the pulsatile flow in a rigid round tube under the low-frequency varying magnetic field is obtained. The velocity distribution and the flow impedance a... In this paper, the analytic solution of the dynamical equation of the pulsatile flow in a rigid round tube under the low-frequency varying magnetic field is obtained. The velocity distribution and the flow impedance are calculated. The results of e valuable for understanding the influence of low-frequency varying magnetic field on hemodynamics and its clinical application. 展开更多
关键词 low-frequency varying magnetic field pulsatile flow IMPEDANCE impedance ratio
下载PDF
Simultaneous resonance of an axially moving ferromagnetic thin plate under a line load in a time-varying magnetic field 被引量:1
3
作者 Xie Mengxue Hu Yuda Xu Haoran 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2023年第4期951-963,共13页
In this paper,the simultaneous resonance of a ferromagnetic thin plate in a time-varying magnetic field,having axial speed and being subjected to a periodic line load,is studied.Based on the large deflection theory of... In this paper,the simultaneous resonance of a ferromagnetic thin plate in a time-varying magnetic field,having axial speed and being subjected to a periodic line load,is studied.Based on the large deflection theory of thin plates and electromagnetic field theory,the nonlinear vibration differential equation of the plate is obtained by using the Hamilton′s principle and the Galerkin method.Then the boundary condition in which the longer opposite sides are clamped and hinged is considered.The dimensionless nonlinear differential equations are solved by using the method of multiple scales,and the analytical solution is given.In addition,the stability analysis is also carried out by using Lyapunov stability theory.Through numerical analysis,the variation curves of system resonance amplitude with frequency tuning parameter,magnetic field strength and external excitation amplitude are obtained.Different parameters that have significant effects on the response of the system,such as the thickness,the axial velocity,the magnetic field intensity,the position,and the frequency of external excitation,are considered and analyzed.The results show that the system has multiple solution regions and obvious nonlinear coupled characteristics. 展开更多
关键词 ferromagnetic thin plate time-varying magnetic field simultaneous resonance axially moving line load
下载PDF
Experiment on low-frequency electromagnetic waves propagating in shock-tube-generated magnetized cylindrical enveloping plasma 被引量:1
4
作者 Shaoshuai GUO Kai XIE +2 位作者 Bin SUN Ruoyao XI Yan LIU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2021年第7期67-77,共11页
We propose a method of applying a static magnetic field to reduce the attenuation of the magnetic field component(SH) of low-frequency electromagnetic(LF EM) waves in dense plasma. The principle of this method is to a... We propose a method of applying a static magnetic field to reduce the attenuation of the magnetic field component(SH) of low-frequency electromagnetic(LF EM) waves in dense plasma. The principle of this method is to apply a static magnetic field to limit electron movement, thereby increasing the equivalent resistance and thus reducing the induced current and SH. We consider the static magnetic field acting on the plasma of the entire induced current loop rather than on the local plasma, where the induced current is excited by the magnetic field component of LF EM waves. Analytical expressions of SH suitable for magnetized cylindrical enveloping plasma are derived by adopting an equivalent circuit approach, by which SHis calculated with respect to various plasma parameter settings. The results show that SH can be reduced under a static magnetic field and the maximum magnetic field strength that mitigates blackout is less than 0.1 T. Experiments in which LF EM waves propagate in a shock-tubegenerated magnetized cylindrical enveloping plasma are also conducted. SH measured under the magnetic field(the magnetic field strength B0 acting on the magnetic field probe was about0.06 T) reduces at f=10 MHz and f=30 MHz when ne≈1.9×1013 cm-3, which is consistent with theoretical results. The verification of the theory thus suggests that applying a static magnetic field with a weak magnetic field has the potential to improve the transmission capacity of LF EM waves in dense plasma. 展开更多
关键词 static magnetic field shock tube low-frequency electromagnetic waves cylindrical enveloping plasma
下载PDF
Development of a low-frequency magnetic lightning mapping system(LFM-LMS)in North China:validation and preliminary results
5
作者 Xiao Li GaoPeng Lu +3 位作者 FanChao Lyu HongBo Zhang Kainat Qamar RuBin Jiang 《Earth and Planetary Physics》 CAS CSCD 2023年第4期460-470,共11页
A low-frequency magnetic lightning mapping system(LFM-LMS)was built during the SHAndong Triggered Lightning Experiment(SHATLE),based on continuous measurements of magnetic field radiation from lightning.The hardware a... A low-frequency magnetic lightning mapping system(LFM-LMS)was built during the SHAndong Triggered Lightning Experiment(SHATLE),based on continuous measurements of magnetic field radiation from lightning.The hardware and source-mapping techniques used by the LFM-LMS were introduced;both Monte Carlo simulations and the observation of rocket-triggered lightning examples were employed to examine the location accuracy and detection effectiveness of the LFM-LMS.We estimated that the system’s location accuracy about 100−200 m horizontally and~200 m vertically.A natural intra-cloud lightning flash and a rocket-triggered lightning flash,both with intricate structures and discharging processes,were examined using the three-dimensional mapping results.The progressing path of negative lightning leaders is usually well-defined,and its propagation speed is estimated to be(0.5−1.4)×10^(6)m/s.In summary,the LFM-LMS can reconstruct the three-dimensional morphology of lightning flashes;this technology provides a efficient method for investigating the characteristics of lightning development,as well as the overall electrical strucuture of thunderstorms. 展开更多
关键词 rocket-triggered lightning low-frequency magnetic field lightning mapping observation location accuracy
下载PDF
Numerical and experimental studies on the effectiveness of time-varying electromagnetic fields in reducing electron density
6
作者 郭韶帅 谢楷 +2 位作者 徐晗 付麦霞 牛营营 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第6期30-40,共11页
When an aircraft or a hypersonic vehicle re-enters the atmosphere,the plasma sheath generated can severely attenuate electromagnetic wave signals,causing the problem of communication blackout.A new method based on tim... When an aircraft or a hypersonic vehicle re-enters the atmosphere,the plasma sheath generated can severely attenuate electromagnetic wave signals,causing the problem of communication blackout.A new method based on time-varying E×B fields is proposed to improve on the existing static E×B fields and mitigate the radio blackout problem.The use of the existing method is limited by the invalid electron density reduction resulting from current density j=0 A m^(-2)in plasma beyond the Debye radius.The most remarkable feature is the introduction of a time-varying electric field to increase the current density in the plasma to overcome the Debye shielding effect on static electric field.Meanwhile,a magnetic field with the same frequency and phase as the electric field is applied to ensure that the electromagnetic force is always acting on the plasma in one direction.In order to investigate the effect of time-varying E×B fields on the plasma electron density distribution,two directions of voltage application are considered in numerical simulation.The simulation results indicate that different voltage application methods generate electromagnetic forces in different directions in the plasma,resulting in repulsion and vortex effects in the plasma.A comparison of the vortex effect and repulsion effect reveals that the vortex effect is better at reducing the electron density.The local plasma electron density can be reduced by more than 80%through the vortex effect,and the dimensions of the area of reduced electron density reach approximately 6 cm×4 cm,meeting the requirements of electromagnetic wave propagation.Besides,the vortex effect of reducing the electron density in RAM-C(radio attenuation measurements for the study of communication blackout)reentry at an altitude of 40 km is analyzed.On the basis of the simulation results,an experiment based on a rectangular-window discharge device is proposed to demonstrate the effectiveness of the vortex effect.Experimental results show that time-varying E×B fields can reduce the electron density in plasma of 3 cm thickness by 80%at B=0.07 T and U_(0)=1000 V.The investigations confirm the effectiveness of the proposed method in terms of reducing the required strength of the magnetic field and overcoming the Debye shielding effect.Additionally,the method is expected to provide a new way to apply a magnetic window in engineering applications. 展开更多
关键词 BLACKOUT magnetic window method time-varying E×B fields
下载PDF
Macro-physical field of large diameter magnesium alloy billet electromagnetic direct-chill casting:A comparative study 被引量:5
7
作者 Yonghui Jia Xingrui Chen +2 位作者 Qichi Le Hang Wang Lei Bao 《Journal of Magnesium and Alloys》 SCIE EI CAS 2020年第3期716-730,共15页
A comprehensive two-dimensional axisymmetric mathematical model that couples transient electromagnetic force with fluid flow,heat transfer,and solidification was established to describe the interaction of multiphysics... A comprehensive two-dimensional axisymmetric mathematical model that couples transient electromagnetic force with fluid flow,heat transfer,and solidification was established to describe the interaction of multiphysics field during DC casting.The melt flow,heat transfer,and solidification characteristics under differential phase pulse magnetic field and differential phase low-frequency electromagnetic field(DP-PMF and DP-LFEF)were numerically investigated by means of numerical simulation during electromagnetic direct-chill(DC)casting of AZ31 alloy at the same casting conditions.The effects of differential phase electromagnetic fields on Lorentz forces distributions,melt flow,heat transfer,and liquid sump shape were discussed systematically.Based on measured current waveform,the results were compared with those obtained without magnetic field(MF)and under conventional pulse magnetic field(PMF)and low-frequency electromagnetic field(LFEF)under the same conditions.The results show that the application of magnetic fields can significantly change the solidification process of DC casting.Differential phase magnetic fields(DP-LFEF and DP-PMF)can effectively reduce the temperature of the melt in the liquid sump,and the shallower liquid sump depth can be obtained under the differential phase magnetic fields.A large velocity vibration amplitude and a lower temperature are available simultaneously under DP-PMF,resulting in more uniform temperature distribution. 展开更多
关键词 Magnesium alloy Differential phase magnetic field low-frequency magnetic field Heat transfer Direct-chill casting Numerical simulation
下载PDF
Minimum Attenuation of Physiologically-Patterned, 1 µTesla Magnetic Fields through Simulated Skull and Cerebral Space
8
作者 Michael A. Persinger Kevin S. Saroka 《Journal of Electromagnetic Analysis and Applications》 2013年第4期151-156,共6页
To answer the queries concerning penetrability of ~1 μT, physiologically patterned, time-varying magnetic fields through the cranium, the proportions of attenuation through thicknesses and densities of ~3 times that ... To answer the queries concerning penetrability of ~1 μT, physiologically patterned, time-varying magnetic fields through the cranium, the proportions of attenuation through thicknesses and densities of ~3 times that of the human skull were measured directly. There was no reduction in the intensity of the magnetic field when two 2 cm thick dried pine boards (4.3 × 103 kg·m-3) were placed between the pairs of solenoids separated by the approximate width of the skull. Although volumes of water containing intracellular concentrations of ions did not attenuate the field intensity, placement of 290 cm2 of 2 mm sheets of duct metal reduced the amplitude by 25%. Spectra comparisons showed a clear congruence in profiles between direct measurement of the applied field and the original computer-generated pattern. These results indicate there is little validity to claims that weak, time-varying magnetic fields applied in this manner are eliminated or significantly attenuated by the human skull. 展开更多
关键词 time-varying magnetic fieldS Penetrability of the SKULL ATTENUATION Factors PHYSIOLOGICAL Concentrations of Ions 1 MicroTesla magnetic fieldS
下载PDF
Parametric instability of a liquid metal sessile drop under the action of low-frequency alternating magnetic fields 被引量:2
9
作者 雷作胜 郭加宏 +3 位作者 FAUTRELLE Yves ERNST Roland ETAY Jacqueline 任忠鸣 《Journal of Hydrodynamics》 SCIE EI CSCD 2013年第2期300-308,共9页
A 2-D mathematical model is developed in order to simulate a parametric electromagnetic instability oscillation process of a liquid metal droplet under the action of low frequency magnetic field. The Arbitrary Lagrang... A 2-D mathematical model is developed in order to simulate a parametric electromagnetic instability oscillation process of a liquid metal droplet under the action of low frequency magnetic field. The Arbitrary Lagrangian-Eulerian (ALE) method and weak form constraint boundary condition are introduced in this model for implementation of the surface tension and electromagnetic force on liquid droplet free surface. The results of the numerical calculations indicate the appearance of various regimes of oscillation. It is found that according to the magnetic field frequency various types of oscillation modes may be found. The oscillation is originated from an instability phenomenon. The stability diagram of liquid metal droplet in the parameter space of magnetic frequency and magnetic flux density is determined numerically. The diagram is very similar to that found in the so-called parametric instability. 展开更多
关键词 sessile drop parametric instability low-frequency alternating magnetic fields numerical simulation
原文传递
Application of microspectral luminescent analysis to study the intracellular metabolism in single cells and cell systems
10
作者 Natalia A. Karnaukhova Larisa A. Sergievich Valery N. Karnaukhov 《Natural Science》 2010年第5期444-449,共6页
Spectral luminescent analysis of single cells and cellular systems enable us to reveal the initial changes of intracellular metabolism that can followed by human diseases or failure in biocenosis. Two cytodiagnostic s... Spectral luminescent analysis of single cells and cellular systems enable us to reveal the initial changes of intracellular metabolism that can followed by human diseases or failure in biocenosis. Two cytodiagnostic systems of de-vices and techniques have been developed: 1) Microspectrofluorimeters registering the fluo-rescent spectra of individual cells or intracellular organelles used for fundamental investigations of cell reactions and for discovering and studying new dimensionless fluorescent characteristic parameters reflecting the biochemical or physiological properties of the cells;2) Double- and multi-wave microfluorimeters for rapid registration of fluorescent characteristic para- meters for many cells to obtain statistical information about cell population. These techni- ques are useful especially in medical and eco-logical investigations. 展开更多
关键词 INTRACELLULAR Metabolism Spectral LUMINESCENT ANALYSIS Microspectrofluorimeters Double and MULTI-WAVE Microfluorimeters Cytodiagnostics low-frequency Variable magnetic fields Solar Activity
下载PDF
上一页 1 下一页 到第