Thermoacoustic heat pumps are a promising heating technology that utilizes medium/low-grade heat to reduce reliance on electricity.This study proposes a single direct-coupled configuration for a thermoacoustic heat pu...Thermoacoustic heat pumps are a promising heating technology that utilizes medium/low-grade heat to reduce reliance on electricity.This study proposes a single direct-coupled configuration for a thermoacoustic heat pump,aimed at minimizing system complexity and making it suitable for domestic applications.Numerical investiga-tions were conducted under typical household heating conditions,including performance analysis,exergy loss evaluation,and axial distribution of key parameters.Results show that the proposed thermoacoustic heat pump achieves a heating capacity of 5.7 kW and a coefficient of performance of 1.4,with a heating temperature of 300℃and a heat-sink temperature of 55℃.A comparison with existing absorption heat pumps reveals favor-able adaptability for large temperature lift applications.A case study conducted in Finland over an annual cycle analyzes the economic and environmental performance of the system,identifying two distinct modes based on the driving heat source:medium temperature(≥250℃)and low temperature(<250℃),both of which exhibit favorable heating performance.When the thermoacoustic heat pump is driven by waste heat,energy savings of 20.1 MWh/year,emission reductions of 4143 kgCO_(2)/year,and total environmental cost savings of 1629€/year are obtained.These results demonstrate the potential of the proposed thermoacoustic heat pump as a cost-effective and environmentally friendly option for domestic building heating using medium/low-grade heat sources.展开更多
This paper discussed the experimental results of the performance of an organic Rankine cycle(ORC)system with an ultra-low temperature heat source.The low boiling point working medium R134a was adopted in the system.Th...This paper discussed the experimental results of the performance of an organic Rankine cycle(ORC)system with an ultra-low temperature heat source.The low boiling point working medium R134a was adopted in the system.The simulated heat source temperature(SHST)in this work was set from 39.51°C to 48.60°C by the simulated heat source module.The influence of load percentage of simulated heat source(LPSHS)between 50%and 70%,the rotary valve opening(RVO)between 20%and 100%,the resistive load between 36Ωand 180Ωor the no-load of the generator,as well as the autumn and winter ambient temperature on the system performance were studied.The results showed that the stability of the system was promoted when the generator had a resistive load.The power generation(PG)and generator speed(GS)of the system in autumn were better than in winter,but the expander pressure ratio(EPR)was lower than in winter.Keep RVO unchanged,the SHST,the mass flow rate(MFR)of the working medium,GS,and the PG of the system increased with the increasing of LPSHS for different generator resistance load values.When the RVO was 60%,LPSHS was 70%,the SHST was 44.15°C and the resistive load was 72Ω,the highest PG reached 15.11 W.Finally,a simulation formula was obtained for LPSHS,resistance load,and PG,and its correlation coefficient was between 0.9818 and 0.9901.The formula can accurately predict the PG.The experimental results showed that the standard deviation between the experimental and simulated values was below 0.0792,and the relative error was within±5%.展开更多
The spring atmospheric heat source(AHS)over the Tibetan Plateau(TP)has been suggested to affect the Asian summer monsoon and summer precipitation over South China.However,its influence on the summer precipitation in N...The spring atmospheric heat source(AHS)over the Tibetan Plateau(TP)has been suggested to affect the Asian summer monsoon and summer precipitation over South China.However,its influence on the summer precipitation in Northeast China(NEC)remains unknown.The connection between spring TP AHS and subsequent summer precipitation over NEC from 1961 to 2020 is analyzed in this study.Results illustrate that stronger spring TP AHS can enhance subsequent summer NEC precipitation,and higher soil moisture in the Yellow River Valley-North China region(YRVNC)acts as a bridge.During spring,the strong TP AHS could strengthen the transportation of water vapor to East China and lead to excessive rainfall in the YRVNC.Thus,soil moisture increases,which regulates local thermal conditions by decreasing local surface skin temperature and sensible heat.Owing to the memory of soil moisture,the lower spring sensible heat over the YRVNC can last until mid-summer,decrease the land–sea thermal contrast,and weaken the southerly winds over the East Asia–western Pacific region and convective activities over the South China Sea and tropical western Pacific.This modulates the East Asia–Pacific teleconnection pattern,which leads to a cyclonic anomaly and excessive summer precipitation over NEC.展开更多
This study examines the behavior of a micropolar nanofluidflowing over a sheet in the presence of a transverse magneticfield and thermal effects.In addition,chemical(first-order homogeneous)reactions are taken into accoun...This study examines the behavior of a micropolar nanofluidflowing over a sheet in the presence of a transverse magneticfield and thermal effects.In addition,chemical(first-order homogeneous)reactions are taken into account.A similarity transformation is used to reduce the system of governing coupled non-linear partial differ-ential equations(PDEs),which account for the transport of mass,momentum,angular momentum,energy and species,to a set of non-linear ordinary differential equations(ODEs).The Runge-Kutta method along with shoot-ing method is used to solve them.The impact of several parameters is evaluated.It is shown that the micro-rota-tional velocity of thefluid rises with the micropolar factor.Moreover,the radiation parameter can have a remarkable influence on theflow and temperature profiles and on the angular momentum distribution.展开更多
In the present research,we proposed a scheme to address the issues of severe heat damage,high energy consumption,low cooling system efficiency,and wastage of cold capacity in mines.To elucidate the seasonal variations...In the present research,we proposed a scheme to address the issues of severe heat damage,high energy consumption,low cooling system efficiency,and wastage of cold capacity in mines.To elucidate the seasonal variations of environmental temperature through field measurements,we selected a high-temperature working face in a deep mine as our engineering background.To enhance the heat damage control cability of the working face and minimize unnecessary cooling capac-ity loss,we introduced the multi-dimensional heat hazard prevention and control method called"Heat source barrier and cooling equipment".First,we utilize shotcrete and liquid nitrogen injection to eliminate the heat source and implemented pressure equalization ventilation to disrupt the heat transfer path,thereby creating a heat barrier.Second,we establish divi-sional prediction models for airflow temperature based on the variation patterns obtained through numerical simulation.Third,we devise the location and dynamic control strategy for the cooling equipment based on the prediction models.The results of field application show that the heat resistance and cooling linkage method comply with the safety requirement throughout the entire mining cycle while effectively reducing energy consumption.The ambient temperature is maintained below 30℃,resulting in the energy saving of 10%during the high-temperature period and over 50%during the low-temperature period.These findings serve as a valuable reference for managing heat damage in high-temperature working faces.展开更多
Thermal energy is abundantly available in our daily life and industrial production,and especially,low-grade heat is often regarded as a byproduct.Collecting and utilizing this ignored energy by low-cost and simple tec...Thermal energy is abundantly available in our daily life and industrial production,and especially,low-grade heat is often regarded as a byproduct.Collecting and utilizing this ignored energy by low-cost and simple technologies may become a smart countermeasure to relieve the energy crisis.Here,a unique device has been demonstrated to achieve high value-added conversion of low-grade heat by introducing redox-active organic alizarin(AZ)onto N-doped hollow carbon nanofibers(N–HCNF)surface.As-prepared N–HCNF/AZ can deliver a high specific capacitance of 514.3 F g^(-1)(at 1 A g^(-1))and an outstanding rate capability of 60.3%even at 50 A g^(-1).Meanwhile,the assembled symmetric proton capacitor can deliver a high energy density of 28.0 Wh kg^(-1) at 350.0 W kg^(-1) and a maximum power density of 35.0 kW kg^(-1) at 17.0 Wh kg^(-1).Significantly,the thermally chargeable proton capacitors can attain a surprisingly high Seebeck coefficient of 15.3 mV K^(-1) and a power factor of 6.02µW g^(-1).Taking advantage of such high performance,a satisfying open-circuit voltage of 481.0 mV with a temperature difference of 54 K is achieved.This research provides new insights into construction of high value-added energy systems requiring high electrochemical performances.展开更多
An active pipe-embedded building envelope, which is an external wall or roof with pipes embedded inside, was presented. This structure may utilize the circulating water in the pipe to transfer heat or coolth inside di...An active pipe-embedded building envelope, which is an external wall or roof with pipes embedded inside, was presented. This structure may utilize the circulating water in the pipe to transfer heat or coolth inside directly. This kind of structure is named "active pipe-embedded building envelope" due to dealing with the thermal energy actively inside the structure mass by circulating water. This structure not only deals with thermal energy before the external disturbance becomes cooling/heating load by using the circulating water, but also may use low-grade energy sources such as evaporative cooling, solar energy, and geothermal energy. In the meantime, this structure can also improve the indoor thermal comfort by tempering the internal wall surface temperature variation due to the thermal removal in the mass. This work further presents the thermal performance of this structure under a typical hot summer weather condition by comparing it with that of the conventional external wall/roof with numerical simulation. The results show that this pipe-embedded structure may reduce the external heat transfer significantly and reduce the internal wall surface temperature for improving thermal comfort. This work also presents the effects of the water temperature and the pipe spacing on the heat transfer of this structure. The internal surface heat transfer may reduce by about 2.6 W/mE when the water temperature reduces by 1℃ as far as a brick wall with pipes embedded inside is concerned. When the pipe spacing reduces by 50 mm, the internal wall surface heat flux can also reduce by about 2.3 W/m2.展开更多
The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowle...The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowledge base and inference engine were proposed while the realization technique of the C language was discussed. An intelligent decision support system (IDSS) model based on such knowledge representation and inference mechanism was developed by domain engineers. The model was verified to have a small kernel and powerful capability in list processing and data driving, which was successfully used in the design of a cooling/heating sources system for a large-sized office building.展开更多
The variability of the summer rainfall over China is analyzed using the EOF procedure with a new parameter (namely, mode station variance percentage) based on 1951-2000 summer rainfall data from 160 stations in Chin...The variability of the summer rainfall over China is analyzed using the EOF procedure with a new parameter (namely, mode station variance percentage) based on 1951-2000 summer rainfall data from 160 stations in China. Compared with mode variance friction, the mode station variance percentage not only reveals more localized characteristics of the variability of the summer rainfall, but also helps to distinguish the regions with a high degree of dominant EOF modes representing the analyzed observational variable. The atmospheric circulation diagnostic studies with the NCEP/NCAR reanalysis daily data from 1966 to 2000 show that in summer, abundant (scarce) rainfall in the belt-area from the upper-middle reaches of the Yangtze River northeastward to the Huaihe River basin is linked to strong (weak) heat sources over the eastern Tibetan Plateau, while the abundant (scarce) rainfall in the area to the south of the middle-lower reaches of the Yangtze River is closely linked to the weak (strong) heat sources over the tropical western Pacific.展开更多
The apparent heat sources (?Q1 ?) and moisture sinks (?Q2 ?) are calculated based on the reanalyzed data of the South China Sea Monsoon Experiment (SCSMEX) from May 1 to August 31, 1998. It is found that the formation...The apparent heat sources (?Q1 ?) and moisture sinks (?Q2 ?) are calculated based on the reanalyzed data of the South China Sea Monsoon Experiment (SCSMEX) from May 1 to August 31, 1998. It is found that the formation and distribution of the atmospheric heat sources are important for the monsoon onset. The earlier onset of the SCS monsoon is the result of enduring atmospheric heating in the Indo–China Peninsula and South China areas. The atmospheric heating firstly appears in the Indo–China Peninsula area and the sensible heat is the major one. The 30–50 day periodic oscillation of atmospheric heat sources between the SCS area and the western Pacific warm pool has a reverse phase distribution before the middle of July and the low frequency oscillation of heat sources in SCS area has an obvious longitudinal propagation. The 30–50 day low frequency oscillation has vital modificatory effects on the summer monsoon evolution during 1998. Key words Apparent heat sources - Apparent moisture sinks - The South China Sea monsoon - Diagnostic Study Sponsored by the National Key Project of Fundamental Research “ SCSMEX” and the Research Fund for the Doctoral Program of Higher Education: “ Study of the Air-sea Interaction in the SCS Monsoon Region”.展开更多
Hot dry rock(HDR) is an important geothermal resource and clean energy source that may play an increasingly important role in future energy management. High-temperature HDR resources were recently detected in deep reg...Hot dry rock(HDR) is an important geothermal resource and clean energy source that may play an increasingly important role in future energy management. High-temperature HDR resources were recently detected in deep regions of the Gonghe Basin on the northeastern edge of the Tibetan Plateau, which led to a significant breakthrough in HDR resource exploration in China. This research analyzes the deep temperature distribution, radiogenic heat production, heat flow, and crustal thermal structure in the Qiaboqia Valley, Guide Plain, and Zhacanggou area of the Gonghe Basin based on geothermal exploration borehole logging data, rock thermophysical properties, and regional geophysical exploration data. The results are applied to discuss the heat accumulation mechanism of the HDR resources in the Gonghe Basin. The findings suggest that a low-velocity layer in the thickened crust of the Tibetan Plateau provides the most important source of constant intracrustal heat for the formation of HDR resources in the Gonghe Basin, whereas crustal thickening redistributes the concentrated layer of radioactive elements, which compensates for the relatively low heat production of the basal granite and serves as an important supplement to the heat of the HDR resources. The negative effect is that the downward curvature of the lithospheric upper mantle caused by crustal thickening leads to a small mantle heat flow component. As a result, the heat flows in the Qiaboqia Valley and Guide Plain of the Gonghe Basin are 106.2 and 77.6 m W/m2, respectively, in which the crust-mantle heat flow ratio of the former is 3.12:1, indicating a notably anomalous intracrustal thermal structure. In contrast, the crust-mantle heat flow ratio in the Guide Plain is 1.84:1, which reflects a typical hot crust-cold mantle thermal structure. The Guide Plain and Zhacanggou area show the same increasing temperature trend with depth, which reflects that their geothermal backgrounds and deep high-temperature environments are similar. These results provide important insight on the heat source mechanism of HDR resource formation in the Tibetan Plateau and useful guidance for future HDR resource exploration projects and target sites selection in similar areas.展开更多
Using the summer (June to August) monthly mean data of the National Centers for Environmental Predictions (NCEP) - National Center for Atmospheric Research (NCAR) reanalysis from 1980 to 1997, atmospheric heat sources...Using the summer (June to August) monthly mean data of the National Centers for Environmental Predictions (NCEP) - National Center for Atmospheric Research (NCAR) reanalysis from 1980 to 1997, atmospheric heat sources and moisture sinks are calculated. Anomalous circulation and the vertically integrated heat source with the vertical integrated moisture sink and outgoing longwave radiation (OLR) flux are examined based upon monthly composites for 16 great wet-spells and 8 great dry-spells over the middle-lower reaches of the Yangtze River. The wind anomaly exhibits prominent differences between the great wet-spell and the great dry-spell over the Yangtze River Valley. For the great wet-spell, the anomalous southerly from the Bay of Bengal and the South China Sea and the anomalous northerly over North China enhanced low-level convergence toward a narrow latitudinal belt area (the middle-lower reaches of the Yangtze River). The southerly anomaly is connected with an anticyclonic anomalous circulation system centered at 22 degreesN, 140 degreesE and the northerly anomaly is associated with a cyclonic anomalous circulation system centered at the Japan Sea. In the upper level, the anomalous northwesterly between an anticyclonic anomalous system with the center at 23 degreesN, 105 degreesE and a cyclonic anomalous system with the center at Korea diverged over the middle-lower reaches of the Yangtze River. On the contrary, for the great dry-spell, the anomalous northerly over South China and the anomalous southerly over North China diverged from the Yangtze River Valley in the low level. The former formed in the western part of a cyclonic anomalous system centered at 23 degreesN, 135 degreesE. The latter was located in the western ridge of an anticyclonic anomalous system in the northwestern Pacific. The upper troposphere showed easterly anomaly that converged over the middle-lower reaches of the Yangtze River. A cyclonic anomalous system in South China and an anticyclonic system centered in the Japan Sea enhanced the easterly. Large atmospheric heat source anomalies of opposite signs existed over the western Pacific - the South China Sea, with negative in the great wet-spell and positive in the great dry-spell. The analysis of heat source also revealed positive anomalous heat sources during the great wet-spell and negative anomalous heat sources during the great dry-spell over the Yangtze River valley. The changes of the moisture sink and OLR were correspondingly altered, implying the change of heat source anomaly is due to the latent heat releasing of convective activity. Over the southeastern Tibetan Plateau- the Bay of Bengal, the analysis of heat source shows positive anomalous heat sources during the great wet-spell and negative anomalous heat sources during the great dry-spell because of latent heating change. The change of divergent wind coexisted with the change of heat source. In the great wet-spell, southerly divergent wind anomaly in the low level and northerly divergent wind anomaly in high-level are seen over South China. These divergent wind anomalies are helpful to the low-level convergence anomaly and high-level divergence anomaly over the Yangtze River valley. The low-level northerly divergent wind anomaly and high-level southerly divergent wind anomaly over South China reduced the low-level convergence and high-level divergence over the Yangtze River valley during the great dry-spell.展开更多
Based on the fifth-generation reanalysis dataset from the European Centre for Medium-Range Weather Forecasts for 1979–2019,we investigated the effects of the circumglobal teleconnection(CGT)on the interdecadal variat...Based on the fifth-generation reanalysis dataset from the European Centre for Medium-Range Weather Forecasts for 1979–2019,we investigated the effects of the circumglobal teleconnection(CGT)on the interdecadal variation of the March atmospheric heat source(AHS)over the Southeast Asian low-latitude highlands(SEALLH).The dominant mode of the March AHS over the SEALLH features a monopole structure with an 8–11-year period.Decadal variations in the AHS make an important contribution to the 11-year low-pass filtered component of the AHS index,whichexplains 54.3%of the total variance.The CGT shows a clear interdecadal variation,which explains 59.3%of the total variance.The March AHS over the SEALLH is significantly related to the CGT on interdecadal timescales.When the CGT is optimally excited by a significant cyclonic vorticity source near northern Africa(i.e.,in its positive phase),the SEALLH is dominated by anomalous southerly winds and ascending motions on the east of the anomalous cyclone.The enhanced advection and upward transfer result in a high-enthalpy air mass that converges into and condenses over the SEALLH,leading to a largerthan-average March AHS over this region.The key physical processes revealed by this diagnostic analysis are supported by numerical experiments.展开更多
It is common sense that a deeper well implies higher temperature in the exploration of deep geothermal resources, especially with hot dry rock(HDR) geothermal resources, which are generally exploited in terms of enhan...It is common sense that a deeper well implies higher temperature in the exploration of deep geothermal resources, especially with hot dry rock(HDR) geothermal resources, which are generally exploited in terms of enhanced geothermal systems(EGS). However, temperature is always different even at the same depth in the upper crust due to different heat sources. This paper summarizes the heat sources and classifies them into two types and five sub-types: crustorigin(partial melting, non-magma-generated tectonic events and radiogenic heat production), and mantle-origin(magma and heat conducted from the mantle). A review of global EGS sites is presented related to the five sub-types of heat sources. According to our new catalog, 71% of EGS sites host mantle-origin heat sources. The temperature logging curves indicate that EGS sites which host mantle-origin magma heat sources have the highest temperature. Therefore, high heat flow(>100 m W/m^(2)) regions with mantle-origin magma heat sources should be highlighted for the future exploration of EGS. The principle to identify the heat source is elucidated by applying geophysical and geochemical methods including noble gas isotope geochemistry and lithospheric thermal structure analysis. This analytical work will be helpful for the future exploration and assessment of HDR geothermal resources.展开更多
To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr...To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance.展开更多
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e...For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.展开更多
Investigating the temporal and spatial distributions of the atmospheric heat sources(AHS)over the Tibetan Plateau-Tropical Indian Ocean(TP-TIO)region is of great importance for the understanding of the evolution and d...Investigating the temporal and spatial distributions of the atmospheric heat sources(AHS)over the Tibetan Plateau-Tropical Indian Ocean(TP-TIO)region is of great importance for the understanding of the evolution and development of the South Asian summer monsoon(SASM).This study used the Japanese 55-year Reanalysis(JRA-55)data from 1979 to 2016 and adopted statistical methods to study the characteristics of the AHS between the TP and TIO,and theirs link to the SASM on an interannual scale.The results indicated that the monthly variations of the AHS in the two regions were basically anti-phase,and that the summer AHS in the TP was obviously stronger than that in the TIO.There were strong AHS and atmospheric moisture sink(AMS)centers in both the eastern and western TP in summer.The AHS center in the east was stronger than that in the west,and the AMS centers showed the opposite pattern.In the TIO,a strong AHS center in the northwest-southeast direction was located near 10°S,90°E.Trend analysis showed that summer AHS in the TIO was increasing significantly,especially before 1998,whereas there was a weakening trend in the TP.The difference of the summer AHS between the TP and TIO(hereafter IQ)was used to measure the thermal contrast between the TP and the TIO.The IQ showed an obvious decreasing trend.After 1998,there was a weak thermal contrast between the TP and the TIO,which mainly resulted from the enhanced AHS in the TIO.The land-sea thermal contrast,the TIO Hadley circulation in the southern hemisphere and the SASM circulation all weakened,resulting in abnormal circulation and abnormal precipitation in the Bay of Bengal(BOB).展开更多
Forward modelling of gravity and magnetic data was done simultaneously to show the correlation between gravity and magnetic anomalies on a measured heat flux region. The results were used to characterize the heat sour...Forward modelling of gravity and magnetic data was done simultaneously to show the correlation between gravity and magnetic anomalies on a measured heat flux region. The results were used to characterize the heat source structures in Eburru area. Modelling was done using Oasis montaj geosoft software which is an iteration process where the gravity and magnetic anomalies were calculated and compared to the observed residual anomaly until there was a fit. The start model was constructed based on depths from Euler deconvolution and models constrained using stratigraphy data from the existing wells in the study area. <span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">Forward modelling of gravity and magnetic data revealed intrusions within the Earth’s subsurface with depth to the top of the sources ranging from </span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">739 m</span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> to </span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">5811 m</span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">. The density of the sources ranges between </span></span></span></span><span><span><span><span style="font-family:""><span style="font-family:Verdana;">3.0 g/cm</span><sup><span style="font-family:Verdana;">3</span></sup></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> and </span></span></span></span><span><span><span><span style="font-family:""><span style="font-family:Verdana;">3.2 g/cm</span><sup><span style="font-family:Verdana;">3</span></sup></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> while their magnetic susceptibility was zero. This implies that intrusions from the mantle with a magnetic susceptibility of zero have temperatures exceeding the curie temperature of rocks. The density of the intrusions modelled was higher than 2.67 </span></span></span></span><span><span><span><span style="font-family:""><span style="font-family:Verdana;">g/cm</span><sup><span style="font-family:Verdana;">3</span></sup></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">, the average crustal density, hence it explains the observed positive gravity anomaly. </span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">The results also revealed that areas with high heat flux have shallow heat sources and if the heat sources are deep, then there must be a good heat transfer mechanism to the surface.</span></span></span></span>展开更多
In this paper there are established the global existence and finite time blow-up results of nonnegative solution for the following parabolic system ut = △u + v^P(x0, t) - au^τ, x ∈ Ω, t 〉 0, △u + v^P(x0, t...In this paper there are established the global existence and finite time blow-up results of nonnegative solution for the following parabolic system ut = △u + v^P(x0, t) - au^τ, x ∈ Ω, t 〉 0, △u + v^P(x0, t) - bu^τ, x ∈ Ω, t 〉 0 subject to homogeneous Dirichlet conditions and nonnegative initial data, where x0 ∈ Ω is a fixed point, p, q, r, s ≥ 1 and a, b 〉 0 are constants. In the situation when nonnegative solution (u, v) of the above problem blows up in finite time, it is showed that the blow-up is global and this differs from the local sources case. Moreover, for the special case r = s = 1, lim t→T*(T*-t)^p+1/pq-1u(x,t)=(p+1)^1/pq-1(q+1)^p/pq-1(pq-1)^-p+1/pq-1, lim t→T*(T*-t)^q+1/pq-1u(x,t)=(p+1)^1/pq-1(q+1)^p/pq-1(pq-1)^-p+1/pq-1 are obtained uniformly on compact subsets of/2, where T* is the blow-up time.展开更多
This article is focused on technical and economic evaluation of more than 6-years experiences of operating the Waste Heat Recovery technology—the manner and system of flue gas processing generated in the combustion p...This article is focused on technical and economic evaluation of more than 6-years experiences of operating the Waste Heat Recovery technology—the manner and system of flue gas processing generated in the combustion process in heat & power plants, cogeneration units, etc., which burn the gaseous fuel, primarily natural gas, or methane, biogas, geothermal gas, or other gaseous mixtures containing hydrogen. The solution proposes a more effective and non-traditional use of gaseous fuel for heating, the flue gases of which are processed in order to extract additional utilisable heat, with potential elimination of CO2 from them. Deploying of the heating plant in an island regime (OFF-GRID) enables definition of the benefits brought by the 3 years of operational experience and presents visions for the future offering the possibility to utilise the support energy services at the municipal as well as regional level.展开更多
基金financially supported by the National Natural Sci-ence Foundation of China (Grant No.51876213 and No.51976230)Strategic Priority Research Programme,CAS (No.XDA21080300)+1 种基金the Open Project of CAS Laboratory of Cryogenics,No.CRYO202214supported by University of Canterbury with the award No.452DISDZ.
文摘Thermoacoustic heat pumps are a promising heating technology that utilizes medium/low-grade heat to reduce reliance on electricity.This study proposes a single direct-coupled configuration for a thermoacoustic heat pump,aimed at minimizing system complexity and making it suitable for domestic applications.Numerical investiga-tions were conducted under typical household heating conditions,including performance analysis,exergy loss evaluation,and axial distribution of key parameters.Results show that the proposed thermoacoustic heat pump achieves a heating capacity of 5.7 kW and a coefficient of performance of 1.4,with a heating temperature of 300℃and a heat-sink temperature of 55℃.A comparison with existing absorption heat pumps reveals favor-able adaptability for large temperature lift applications.A case study conducted in Finland over an annual cycle analyzes the economic and environmental performance of the system,identifying two distinct modes based on the driving heat source:medium temperature(≥250℃)and low temperature(<250℃),both of which exhibit favorable heating performance.When the thermoacoustic heat pump is driven by waste heat,energy savings of 20.1 MWh/year,emission reductions of 4143 kgCO_(2)/year,and total environmental cost savings of 1629€/year are obtained.These results demonstrate the potential of the proposed thermoacoustic heat pump as a cost-effective and environmentally friendly option for domestic building heating using medium/low-grade heat sources.
基金This work was supported by Tianjin Natural Science Foundation(No.21JCZDJC00750).
文摘This paper discussed the experimental results of the performance of an organic Rankine cycle(ORC)system with an ultra-low temperature heat source.The low boiling point working medium R134a was adopted in the system.The simulated heat source temperature(SHST)in this work was set from 39.51°C to 48.60°C by the simulated heat source module.The influence of load percentage of simulated heat source(LPSHS)between 50%and 70%,the rotary valve opening(RVO)between 20%and 100%,the resistive load between 36Ωand 180Ωor the no-load of the generator,as well as the autumn and winter ambient temperature on the system performance were studied.The results showed that the stability of the system was promoted when the generator had a resistive load.The power generation(PG)and generator speed(GS)of the system in autumn were better than in winter,but the expander pressure ratio(EPR)was lower than in winter.Keep RVO unchanged,the SHST,the mass flow rate(MFR)of the working medium,GS,and the PG of the system increased with the increasing of LPSHS for different generator resistance load values.When the RVO was 60%,LPSHS was 70%,the SHST was 44.15°C and the resistive load was 72Ω,the highest PG reached 15.11 W.Finally,a simulation formula was obtained for LPSHS,resistance load,and PG,and its correlation coefficient was between 0.9818 and 0.9901.The formula can accurately predict the PG.The experimental results showed that the standard deviation between the experimental and simulated values was below 0.0792,and the relative error was within±5%.
基金supported by the Open Research Fund of TPESER(Grant No.TPESER202205)the Second Tibetan Plateau Scientific Expedition and Research Program(Grant No.2019QZKK0101)。
文摘The spring atmospheric heat source(AHS)over the Tibetan Plateau(TP)has been suggested to affect the Asian summer monsoon and summer precipitation over South China.However,its influence on the summer precipitation in Northeast China(NEC)remains unknown.The connection between spring TP AHS and subsequent summer precipitation over NEC from 1961 to 2020 is analyzed in this study.Results illustrate that stronger spring TP AHS can enhance subsequent summer NEC precipitation,and higher soil moisture in the Yellow River Valley-North China region(YRVNC)acts as a bridge.During spring,the strong TP AHS could strengthen the transportation of water vapor to East China and lead to excessive rainfall in the YRVNC.Thus,soil moisture increases,which regulates local thermal conditions by decreasing local surface skin temperature and sensible heat.Owing to the memory of soil moisture,the lower spring sensible heat over the YRVNC can last until mid-summer,decrease the land–sea thermal contrast,and weaken the southerly winds over the East Asia–western Pacific region and convective activities over the South China Sea and tropical western Pacific.This modulates the East Asia–Pacific teleconnection pattern,which leads to a cyclonic anomaly and excessive summer precipitation over NEC.
文摘This study examines the behavior of a micropolar nanofluidflowing over a sheet in the presence of a transverse magneticfield and thermal effects.In addition,chemical(first-order homogeneous)reactions are taken into account.A similarity transformation is used to reduce the system of governing coupled non-linear partial differ-ential equations(PDEs),which account for the transport of mass,momentum,angular momentum,energy and species,to a set of non-linear ordinary differential equations(ODEs).The Runge-Kutta method along with shoot-ing method is used to solve them.The impact of several parameters is evaluated.It is shown that the micro-rota-tional velocity of thefluid rises with the micropolar factor.Moreover,the radiation parameter can have a remarkable influence on theflow and temperature profiles and on the angular momentum distribution.
基金supported by the National Natural Science Foundation of China (51874281)the Graduate Innovation Program of China University of Mining and Technology (2022WLKXJ006)the Postgraduate Research&Practice Innovation Program of Jiangsu Province (KYCX22_2612).
文摘In the present research,we proposed a scheme to address the issues of severe heat damage,high energy consumption,low cooling system efficiency,and wastage of cold capacity in mines.To elucidate the seasonal variations of environmental temperature through field measurements,we selected a high-temperature working face in a deep mine as our engineering background.To enhance the heat damage control cability of the working face and minimize unnecessary cooling capac-ity loss,we introduced the multi-dimensional heat hazard prevention and control method called"Heat source barrier and cooling equipment".First,we utilize shotcrete and liquid nitrogen injection to eliminate the heat source and implemented pressure equalization ventilation to disrupt the heat transfer path,thereby creating a heat barrier.Second,we establish divi-sional prediction models for airflow temperature based on the variation patterns obtained through numerical simulation.Third,we devise the location and dynamic control strategy for the cooling equipment based on the prediction models.The results of field application show that the heat resistance and cooling linkage method comply with the safety requirement throughout the entire mining cycle while effectively reducing energy consumption.The ambient temperature is maintained below 30℃,resulting in the energy saving of 10%during the high-temperature period and over 50%during the low-temperature period.These findings serve as a valuable reference for managing heat damage in high-temperature working faces.
基金This work was supported by the National Natural Science Foundation of China(U1802256,21773118)Leading Edge Technology of Jiangsu Province(BK20202008)+1 种基金Postgraduate Research&Practice Innovation Program of Jiangsu Province(KYCX21_0204)Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD).
文摘Thermal energy is abundantly available in our daily life and industrial production,and especially,low-grade heat is often regarded as a byproduct.Collecting and utilizing this ignored energy by low-cost and simple technologies may become a smart countermeasure to relieve the energy crisis.Here,a unique device has been demonstrated to achieve high value-added conversion of low-grade heat by introducing redox-active organic alizarin(AZ)onto N-doped hollow carbon nanofibers(N–HCNF)surface.As-prepared N–HCNF/AZ can deliver a high specific capacitance of 514.3 F g^(-1)(at 1 A g^(-1))and an outstanding rate capability of 60.3%even at 50 A g^(-1).Meanwhile,the assembled symmetric proton capacitor can deliver a high energy density of 28.0 Wh kg^(-1) at 350.0 W kg^(-1) and a maximum power density of 35.0 kW kg^(-1) at 17.0 Wh kg^(-1).Significantly,the thermally chargeable proton capacitors can attain a surprisingly high Seebeck coefficient of 15.3 mV K^(-1) and a power factor of 6.02µW g^(-1).Taking advantage of such high performance,a satisfying open-circuit voltage of 481.0 mV with a temperature difference of 54 K is achieved.This research provides new insights into construction of high value-added energy systems requiring high electrochemical performances.
基金Project(51178201) supported by the National Natural Science Foundation of China Project(2011CDB292) supported by the Natural Science Foundation of Hubei Province,China
文摘An active pipe-embedded building envelope, which is an external wall or roof with pipes embedded inside, was presented. This structure may utilize the circulating water in the pipe to transfer heat or coolth inside directly. This kind of structure is named "active pipe-embedded building envelope" due to dealing with the thermal energy actively inside the structure mass by circulating water. This structure not only deals with thermal energy before the external disturbance becomes cooling/heating load by using the circulating water, but also may use low-grade energy sources such as evaporative cooling, solar energy, and geothermal energy. In the meantime, this structure can also improve the indoor thermal comfort by tempering the internal wall surface temperature variation due to the thermal removal in the mass. This work further presents the thermal performance of this structure under a typical hot summer weather condition by comparing it with that of the conventional external wall/roof with numerical simulation. The results show that this pipe-embedded structure may reduce the external heat transfer significantly and reduce the internal wall surface temperature for improving thermal comfort. This work also presents the effects of the water temperature and the pipe spacing on the heat transfer of this structure. The internal surface heat transfer may reduce by about 2.6 W/mE when the water temperature reduces by 1℃ as far as a brick wall with pipes embedded inside is concerned. When the pipe spacing reduces by 50 mm, the internal wall surface heat flux can also reduce by about 2.3 W/m2.
文摘The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowledge base and inference engine were proposed while the realization technique of the C language was discussed. An intelligent decision support system (IDSS) model based on such knowledge representation and inference mechanism was developed by domain engineers. The model was verified to have a small kernel and powerful capability in list processing and data driving, which was successfully used in the design of a cooling/heating sources system for a large-sized office building.
基金This work was supported by the National Key Program for Developing Basic Research (Grant No. 2004CB418303)the National Natural Science Foundation of China (Grant No. 40175018).
文摘The variability of the summer rainfall over China is analyzed using the EOF procedure with a new parameter (namely, mode station variance percentage) based on 1951-2000 summer rainfall data from 160 stations in China. Compared with mode variance friction, the mode station variance percentage not only reveals more localized characteristics of the variability of the summer rainfall, but also helps to distinguish the regions with a high degree of dominant EOF modes representing the analyzed observational variable. The atmospheric circulation diagnostic studies with the NCEP/NCAR reanalysis daily data from 1966 to 2000 show that in summer, abundant (scarce) rainfall in the belt-area from the upper-middle reaches of the Yangtze River northeastward to the Huaihe River basin is linked to strong (weak) heat sources over the eastern Tibetan Plateau, while the abundant (scarce) rainfall in the area to the south of the middle-lower reaches of the Yangtze River is closely linked to the weak (strong) heat sources over the tropical western Pacific.
基金National Key Project of Fundamental Research u SCSMEX" the Research Fund for the Doctoral Program of Higher Education:" Stud
文摘The apparent heat sources (?Q1 ?) and moisture sinks (?Q2 ?) are calculated based on the reanalyzed data of the South China Sea Monsoon Experiment (SCSMEX) from May 1 to August 31, 1998. It is found that the formation and distribution of the atmospheric heat sources are important for the monsoon onset. The earlier onset of the SCS monsoon is the result of enduring atmospheric heating in the Indo–China Peninsula and South China areas. The atmospheric heating firstly appears in the Indo–China Peninsula area and the sensible heat is the major one. The 30–50 day periodic oscillation of atmospheric heat sources between the SCS area and the western Pacific warm pool has a reverse phase distribution before the middle of July and the low frequency oscillation of heat sources in SCS area has an obvious longitudinal propagation. The 30–50 day low frequency oscillation has vital modificatory effects on the summer monsoon evolution during 1998. Key words Apparent heat sources - Apparent moisture sinks - The South China Sea monsoon - Diagnostic Study Sponsored by the National Key Project of Fundamental Research “ SCSMEX” and the Research Fund for the Doctoral Program of Higher Education: “ Study of the Air-sea Interaction in the SCS Monsoon Region”.
基金supported by National Key R&D Program of China(Grant No.2018YFB1501803)。
文摘Hot dry rock(HDR) is an important geothermal resource and clean energy source that may play an increasingly important role in future energy management. High-temperature HDR resources were recently detected in deep regions of the Gonghe Basin on the northeastern edge of the Tibetan Plateau, which led to a significant breakthrough in HDR resource exploration in China. This research analyzes the deep temperature distribution, radiogenic heat production, heat flow, and crustal thermal structure in the Qiaboqia Valley, Guide Plain, and Zhacanggou area of the Gonghe Basin based on geothermal exploration borehole logging data, rock thermophysical properties, and regional geophysical exploration data. The results are applied to discuss the heat accumulation mechanism of the HDR resources in the Gonghe Basin. The findings suggest that a low-velocity layer in the thickened crust of the Tibetan Plateau provides the most important source of constant intracrustal heat for the formation of HDR resources in the Gonghe Basin, whereas crustal thickening redistributes the concentrated layer of radioactive elements, which compensates for the relatively low heat production of the basal granite and serves as an important supplement to the heat of the HDR resources. The negative effect is that the downward curvature of the lithospheric upper mantle caused by crustal thickening leads to a small mantle heat flow component. As a result, the heat flows in the Qiaboqia Valley and Guide Plain of the Gonghe Basin are 106.2 and 77.6 m W/m2, respectively, in which the crust-mantle heat flow ratio of the former is 3.12:1, indicating a notably anomalous intracrustal thermal structure. In contrast, the crust-mantle heat flow ratio in the Guide Plain is 1.84:1, which reflects a typical hot crust-cold mantle thermal structure. The Guide Plain and Zhacanggou area show the same increasing temperature trend with depth, which reflects that their geothermal backgrounds and deep high-temperature environments are similar. These results provide important insight on the heat source mechanism of HDR resource formation in the Tibetan Plateau and useful guidance for future HDR resource exploration projects and target sites selection in similar areas.
基金Supported by National Key Programme for Developing Basic Sciences G1998040900 Part 1 and IAPInnovation Foundation 8-1308.
文摘Using the summer (June to August) monthly mean data of the National Centers for Environmental Predictions (NCEP) - National Center for Atmospheric Research (NCAR) reanalysis from 1980 to 1997, atmospheric heat sources and moisture sinks are calculated. Anomalous circulation and the vertically integrated heat source with the vertical integrated moisture sink and outgoing longwave radiation (OLR) flux are examined based upon monthly composites for 16 great wet-spells and 8 great dry-spells over the middle-lower reaches of the Yangtze River. The wind anomaly exhibits prominent differences between the great wet-spell and the great dry-spell over the Yangtze River Valley. For the great wet-spell, the anomalous southerly from the Bay of Bengal and the South China Sea and the anomalous northerly over North China enhanced low-level convergence toward a narrow latitudinal belt area (the middle-lower reaches of the Yangtze River). The southerly anomaly is connected with an anticyclonic anomalous circulation system centered at 22 degreesN, 140 degreesE and the northerly anomaly is associated with a cyclonic anomalous circulation system centered at the Japan Sea. In the upper level, the anomalous northwesterly between an anticyclonic anomalous system with the center at 23 degreesN, 105 degreesE and a cyclonic anomalous system with the center at Korea diverged over the middle-lower reaches of the Yangtze River. On the contrary, for the great dry-spell, the anomalous northerly over South China and the anomalous southerly over North China diverged from the Yangtze River Valley in the low level. The former formed in the western part of a cyclonic anomalous system centered at 23 degreesN, 135 degreesE. The latter was located in the western ridge of an anticyclonic anomalous system in the northwestern Pacific. The upper troposphere showed easterly anomaly that converged over the middle-lower reaches of the Yangtze River. A cyclonic anomalous system in South China and an anticyclonic system centered in the Japan Sea enhanced the easterly. Large atmospheric heat source anomalies of opposite signs existed over the western Pacific - the South China Sea, with negative in the great wet-spell and positive in the great dry-spell. The analysis of heat source also revealed positive anomalous heat sources during the great wet-spell and negative anomalous heat sources during the great dry-spell over the Yangtze River valley. The changes of the moisture sink and OLR were correspondingly altered, implying the change of heat source anomaly is due to the latent heat releasing of convective activity. Over the southeastern Tibetan Plateau- the Bay of Bengal, the analysis of heat source shows positive anomalous heat sources during the great wet-spell and negative anomalous heat sources during the great dry-spell because of latent heating change. The change of divergent wind coexisted with the change of heat source. In the great wet-spell, southerly divergent wind anomaly in the low level and northerly divergent wind anomaly in high-level are seen over South China. These divergent wind anomalies are helpful to the low-level convergence anomaly and high-level divergence anomaly over the Yangtze River valley. The low-level northerly divergent wind anomaly and high-level southerly divergent wind anomaly over South China reduced the low-level convergence and high-level divergence over the Yangtze River valley during the great dry-spell.
基金This work was supported by the National Natural Science Foundation of China(Grant No.42030603)the Natural Science Foundation of Yunnan Province(2019FY003006)the Postgraduate Research and Innovation foundation of Yunnan University(2021Z017).
文摘Based on the fifth-generation reanalysis dataset from the European Centre for Medium-Range Weather Forecasts for 1979–2019,we investigated the effects of the circumglobal teleconnection(CGT)on the interdecadal variation of the March atmospheric heat source(AHS)over the Southeast Asian low-latitude highlands(SEALLH).The dominant mode of the March AHS over the SEALLH features a monopole structure with an 8–11-year period.Decadal variations in the AHS make an important contribution to the 11-year low-pass filtered component of the AHS index,whichexplains 54.3%of the total variance.The CGT shows a clear interdecadal variation,which explains 59.3%of the total variance.The March AHS over the SEALLH is significantly related to the CGT on interdecadal timescales.When the CGT is optimally excited by a significant cyclonic vorticity source near northern Africa(i.e.,in its positive phase),the SEALLH is dominated by anomalous southerly winds and ascending motions on the east of the anomalous cyclone.The enhanced advection and upward transfer result in a high-enthalpy air mass that converges into and condenses over the SEALLH,leading to a largerthan-average March AHS over this region.The key physical processes revealed by this diagnostic analysis are supported by numerical experiments.
基金supported by the National Key Research and Development Program of China(Grant No.2018YFB1501801)the Youth Innovation Promotion Association of Chinese Academy of Sciences(No.2020067)。
文摘It is common sense that a deeper well implies higher temperature in the exploration of deep geothermal resources, especially with hot dry rock(HDR) geothermal resources, which are generally exploited in terms of enhanced geothermal systems(EGS). However, temperature is always different even at the same depth in the upper crust due to different heat sources. This paper summarizes the heat sources and classifies them into two types and five sub-types: crustorigin(partial melting, non-magma-generated tectonic events and radiogenic heat production), and mantle-origin(magma and heat conducted from the mantle). A review of global EGS sites is presented related to the five sub-types of heat sources. According to our new catalog, 71% of EGS sites host mantle-origin heat sources. The temperature logging curves indicate that EGS sites which host mantle-origin magma heat sources have the highest temperature. Therefore, high heat flow(>100 m W/m^(2)) regions with mantle-origin magma heat sources should be highlighted for the future exploration of EGS. The principle to identify the heat source is elucidated by applying geophysical and geochemical methods including noble gas isotope geochemistry and lithospheric thermal structure analysis. This analytical work will be helpful for the future exploration and assessment of HDR geothermal resources.
文摘To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance.
基金This work was supported by the National Key Research and Development Program of China(No.2019YFE0193200 KY202001)Science and Technology Planning Project of Beijing(No.Z201100008320001 KY191004).
文摘For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.
基金Strategic Priority Research Program of Chinese Academy of Sciences(XDA20060501)2019 Non-funded Science and Technology Research Project of Zhanjiang(20051817454-6338)2020 Guangdong Ocean University College Student Innovation and Entrepreneurship Project(580520153)
文摘Investigating the temporal and spatial distributions of the atmospheric heat sources(AHS)over the Tibetan Plateau-Tropical Indian Ocean(TP-TIO)region is of great importance for the understanding of the evolution and development of the South Asian summer monsoon(SASM).This study used the Japanese 55-year Reanalysis(JRA-55)data from 1979 to 2016 and adopted statistical methods to study the characteristics of the AHS between the TP and TIO,and theirs link to the SASM on an interannual scale.The results indicated that the monthly variations of the AHS in the two regions were basically anti-phase,and that the summer AHS in the TP was obviously stronger than that in the TIO.There were strong AHS and atmospheric moisture sink(AMS)centers in both the eastern and western TP in summer.The AHS center in the east was stronger than that in the west,and the AMS centers showed the opposite pattern.In the TIO,a strong AHS center in the northwest-southeast direction was located near 10°S,90°E.Trend analysis showed that summer AHS in the TIO was increasing significantly,especially before 1998,whereas there was a weakening trend in the TP.The difference of the summer AHS between the TP and TIO(hereafter IQ)was used to measure the thermal contrast between the TP and the TIO.The IQ showed an obvious decreasing trend.After 1998,there was a weak thermal contrast between the TP and the TIO,which mainly resulted from the enhanced AHS in the TIO.The land-sea thermal contrast,the TIO Hadley circulation in the southern hemisphere and the SASM circulation all weakened,resulting in abnormal circulation and abnormal precipitation in the Bay of Bengal(BOB).
文摘Forward modelling of gravity and magnetic data was done simultaneously to show the correlation between gravity and magnetic anomalies on a measured heat flux region. The results were used to characterize the heat source structures in Eburru area. Modelling was done using Oasis montaj geosoft software which is an iteration process where the gravity and magnetic anomalies were calculated and compared to the observed residual anomaly until there was a fit. The start model was constructed based on depths from Euler deconvolution and models constrained using stratigraphy data from the existing wells in the study area. <span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">Forward modelling of gravity and magnetic data revealed intrusions within the Earth’s subsurface with depth to the top of the sources ranging from </span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">739 m</span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> to </span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">5811 m</span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">. The density of the sources ranges between </span></span></span></span><span><span><span><span style="font-family:""><span style="font-family:Verdana;">3.0 g/cm</span><sup><span style="font-family:Verdana;">3</span></sup></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> and </span></span></span></span><span><span><span><span style="font-family:""><span style="font-family:Verdana;">3.2 g/cm</span><sup><span style="font-family:Verdana;">3</span></sup></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> while their magnetic susceptibility was zero. This implies that intrusions from the mantle with a magnetic susceptibility of zero have temperatures exceeding the curie temperature of rocks. The density of the intrusions modelled was higher than 2.67 </span></span></span></span><span><span><span><span style="font-family:""><span style="font-family:Verdana;">g/cm</span><sup><span style="font-family:Verdana;">3</span></sup></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">, the average crustal density, hence it explains the observed positive gravity anomaly. </span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">The results also revealed that areas with high heat flux have shallow heat sources and if the heat sources are deep, then there must be a good heat transfer mechanism to the surface.</span></span></span></span>
基金This study is supported partially by the research program of natural science of universities in Jiangsu province(05KJB110144 and 05KJB110063)the natural science foundation of Yancheng normal institute.
文摘In this paper there are established the global existence and finite time blow-up results of nonnegative solution for the following parabolic system ut = △u + v^P(x0, t) - au^τ, x ∈ Ω, t 〉 0, △u + v^P(x0, t) - bu^τ, x ∈ Ω, t 〉 0 subject to homogeneous Dirichlet conditions and nonnegative initial data, where x0 ∈ Ω is a fixed point, p, q, r, s ≥ 1 and a, b 〉 0 are constants. In the situation when nonnegative solution (u, v) of the above problem blows up in finite time, it is showed that the blow-up is global and this differs from the local sources case. Moreover, for the special case r = s = 1, lim t→T*(T*-t)^p+1/pq-1u(x,t)=(p+1)^1/pq-1(q+1)^p/pq-1(pq-1)^-p+1/pq-1, lim t→T*(T*-t)^q+1/pq-1u(x,t)=(p+1)^1/pq-1(q+1)^p/pq-1(pq-1)^-p+1/pq-1 are obtained uniformly on compact subsets of/2, where T* is the blow-up time.
文摘This article is focused on technical and economic evaluation of more than 6-years experiences of operating the Waste Heat Recovery technology—the manner and system of flue gas processing generated in the combustion process in heat & power plants, cogeneration units, etc., which burn the gaseous fuel, primarily natural gas, or methane, biogas, geothermal gas, or other gaseous mixtures containing hydrogen. The solution proposes a more effective and non-traditional use of gaseous fuel for heating, the flue gases of which are processed in order to extract additional utilisable heat, with potential elimination of CO2 from them. Deploying of the heating plant in an island regime (OFF-GRID) enables definition of the benefits brought by the 3 years of operational experience and presents visions for the future offering the possibility to utilise the support energy services at the municipal as well as regional level.