BACKGROUND Non-proliferative diabetic retinopathy(NPDR)poses a significant challenge in diabetes management due to its microvascular changes in the retina.Laser photocoagulation,a conventional therapy,aims to mitigate...BACKGROUND Non-proliferative diabetic retinopathy(NPDR)poses a significant challenge in diabetes management due to its microvascular changes in the retina.Laser photocoagulation,a conventional therapy,aims to mitigate the risk of progressing to proliferative diabetic retinopathy(PDR).AIM To compare the efficacy and safety of multi-spot vs single-spot scanning panretinal laser photocoagulation in NPDR patients.METHODS Forty-nine NPDR patients(86 eyes)treated between September 2020 and July 2022 were included.They were randomly allocated into single-spot(n=23,40 eyes)and multi-spot(n=26,46 eyes)groups.Treatment outcomes,including bestcorrected visual acuity(BCVA),central macular thickness(CMT),and mean threshold sensitivity,were assessed at predetermined intervals over 12 months.Adverse reactions were also recorded.RESULTS Energy levels did not significantly differ between groups(P>0.05),but the multi-spot group exhibited lower energy density(P<0.05).BCVA and CMT improvements were noted in the multi-spot group at one-month posttreatment(P<0.05).Adverse reaction incidence was similar between groups(P>0.05).CONCLUSION While energy intensity and safety were comparable between modalities,multi-spot scanning demonstrated lower energy density and showed superior short-term improvements in BCVA and CMT for NPDR patients,with reduced laser-induced damage.展开更多
BACKGROUND The prevalence of diabetes mellitus(DM)in China is high,and the base is broad.Diabetic retinopathy(DR)is a critical condition affecting the life and health of a nation and its economic development.DR is a c...BACKGROUND The prevalence of diabetes mellitus(DM)in China is high,and the base is broad.Diabetic retinopathy(DR)is a critical condition affecting the life and health of a nation and its economic development.DR is a common complication of DM.AIM To investigate the efficacy of laser photocoagulation combined with intravitreal injection of conbercept for treating macular edema.METHODS Overall,130 patients with diabetic macular edema(DME)hospitalized in The Third People’s Hospital of Changzhou from January 2019 to June 2022 were retrospectively included.According to the treatment plan,130 patients with DME were categorized into an observation and a control group,with 65 patients in each group.The control group received laser photocoagulation,and the observation group received laser photocoagulation with intravitreal injection of conbercept.Observe changes in vision,cytokines in the eye and so on.RESULTS The total efficacy rate in the observation group(93.85%)was higher than that in the control group(78.46%)(P<0.05).In both groups,the best corrected visual acuity correction effect improved after treatment,and the observation group was superior to the control group(P<0.05).Retinal thickness and central macular thickness improved after treatment,and the observation group was superior to the control group(P<0.05).The levels of vascular endothelial growth factor,interleukin-6,soluble intercellular adhesion molecule-1,and basic fibroblast growth factor in both groups improved after treatment,and the observation group was superior to the control group(P<0.05).CONCLUSION In patients with macular edema,combining laser photocoagulation and intravitreal injections of conbercept for DME is a more effective and safer strategy to improve vision,and lower intraocular cytokine levels.展开更多
Low-level laser therapy(LLLT) may have an effect on the pain associated with orthodontic treatment. The aim of this study was to evaluate the effect of LLLT on pain and somatosensory sensitization induced by orthodont...Low-level laser therapy(LLLT) may have an effect on the pain associated with orthodontic treatment. The aim of this study was to evaluate the effect of LLLT on pain and somatosensory sensitization induced by orthodontic treatment. Forty individuals(12–33 years old; mean ± standard deviations: 20.8 ± 5.9 years) scheduled to receive orthodontic treatment were randomly divided into a laser group(LG) or a placebo group(PG)(1:1). The LG received LLLT(810-nm gallium-aluminium-arsenic diode laser in continuous mode with the power set at 400 mW, 2 J·cm–2) at 0 h, 2 h, 24 h, 4 d, and 7 d after treatment, and the PG received inactive treatment at the same time points. In both groups, the non-treated side served as a control. A numerical rating scale(NRS) of pain, pressure pain thresholds(PPTs), cold detection thresholds(CDTs), warmth detection thresholds(WDTs), cold pain thresholds(CPTs), and heat pain thresholds(HPTs) were tested on both sides at the gingiva and canine tooth and on the hand. The data were analysed by a repeated measures analysis of variance(ANOVA). The NRS pain scores were significantly lower in the LG group(P = 0.01). The CDTs,CPTs, WDTs, HPTs, and PPTs at the gingiva and the PPTs at the canine tooth were significantly less sensitive on the treatment side of the LG compared with that of the PG(P < 0.033). The parameters tested also showed significantly less sensitivity on the nontreatment side of the LG compared to that of the PG(P < 0.043). There were no differences between the groups for any quantitative sensory testing(QST) measures of the hand. The application of LLLT appears to reduce the pain and sensitivity of the tooth and gingiva associated with orthodontic treatment and may have contralateral effects within the trigeminal system but no generalized QST effects. Thus, the present study indicated a significant analgesia effect of LLLT application during orthodontic treatment.Further clinical applications are suggested.展开更多
BACKGROUND Selective laser trabeculoplasty(SLT)is a relatively safe and effective therapy in lowering intraocular pressures(IOP)for glaucoma.AIM To study the long-term effects of SLT on IOP and number of glaucoma medi...BACKGROUND Selective laser trabeculoplasty(SLT)is a relatively safe and effective therapy in lowering intraocular pressures(IOP)for glaucoma.AIM To study the long-term effects of SLT on IOP and number of glaucoma medications used in Chinese eyes.METHODS This is a retrospective study in which 75 eyes of 70 patients with open-angle glaucoma(OAG,n=36)and eyes with prior glaucoma surgery(PGS,n=39)were included.Changes in mean IOP and number of glaucoma medications used evaluated at 1 d,1 wk,1 mo,3 mo,6 mo,12 mo,and 36 mo after laser treatment.RESULTS All patients(33 male,37 female)were Chinese.The mean age was 44.34±16.14years.Mean pre-SLT IOP was 22.75±2.08 mmHg in OAG and 22.52±2.62 mmHg in PGS.Mean IOP was significantly reduced 1 d,1 wk,1 mo and 3 mo after laser treatment(P<0.05,respectively).Whereas,there were no significant differences between baseline and SLT treated groups at the 6th month both in OAG(P=0.347,P>0.05)and in PGS(P=0.309,P>0.05).Six months after SLT treatment,some patients received retreatment of SLT or were given more topical IOP-lowering medication to control the IOP.By the end of our study,the average IOP decreased to 20.73±1.82 mmHg in OAG and 20.49±1.53 mmHg in PGS groups.The number of glaucoma medications used was significantly reduced until the end of 3 years compared to baseline.CONCLUSION SLT could reduce IOP as adjunctive treatment both in OAG and PGS groups.SLT significantly reduced the number of glaucoma medications used 3-years following treatment in glaucoma patients.展开更多
BACKGROUND Varicosis is a common venous condition,which is typically treated surgically.However,selection of the optimal surgical approach can be challenging.Previous studies comparing endovenous laser treatment(EVLT)...BACKGROUND Varicosis is a common venous condition,which is typically treated surgically.However,selection of the optimal surgical approach can be challenging.Previous studies comparing endovenous laser treatment(EVLT)and conventional surgery were retrospective and observational in nature and the results may therefore have been influenced by selection bias and the presence of other confounding factors.In this study,we used propensity score matching to reduce selection bias when comparing EVLT and conventional surgery for the treatment of varicose great saphenous veins.METHODS We retrospectively reviewed the records of 1063 patients treated for primary varicosis of the great saphenous vein at the Second Affiliated Hospital of Xuzhou Medical University between January 2009 and December 2019.Among them,56 patients were excluded owing to additional small saphenous varicose vein involvement,81 owing to recurring varicose veins,83 owing to complicated varicose veins(CEAP clinical classification C5-C6),and 6 owing to perioperative phlebitis.Finally,772 patients were enrolled in this study.Standard demographic and clinicopathological data were collected from the medical records of the patients.For propensity score matching,522 patients(261 who underwent EVLT and 261 who underwent conventional surgery)were randomly matched 1:1 by age,sex,onset time,smoking status,presence of diabetes,family history,stress therapy,C class,and the affected leg.RESULTS Of the 772 patients included in the study,467 underwent EVLT and 305 underwent conventional surgery.There were significant differences in age,onset time,smoking and diabetes status,and family history between the two groups.Following propensity score matching,no significant differences in patients’characteristics remained between the two groups.ELVT was associated with a shorter operation time and hospital stay than conventional surgery,both before and after propensity score matching.There were no differences in complications between the two groups after propensity score matching.Patients who underwent EVLT had a higher recurrence rate during the two-year follow-up period than those who underwent conventional surgery(33.33%vs 21.46%,χ^(2)=11.506,P=0.001),and a greater percentage of patients who underwent EVLT experienced pain one week after the procedure(39.85%vs 19.54%,P=0.000).CONCLUSION EVLT may not always be the best option for the treatment of great saphenous vein varicosis.展开更多
Objective:To investigate the effect of Kangfuxin Solution(康复新液)combined with low-level laser therapy(LLLT)on cytokines and immune function in patients with radiation-induced oral mucositis.Methods:There were 84 na...Objective:To investigate the effect of Kangfuxin Solution(康复新液)combined with low-level laser therapy(LLLT)on cytokines and immune function in patients with radiation-induced oral mucositis.Methods:There were 84 nasopharyngeal carcinoma patients with oral mucositis after intensity-modulated radiation therapy(IMRT)were randomly divided into the control group(CG)and the observation group(OG),with 42 cases in each group.The CG was given LLLT,and the OG was treated with Kangfuxin Solution in addition to LLLT for 10 consecutive days.The healing time of oral mucosa,mucositis grading,oral pain scores,cytokines(interleukin-6,interleukin-1βand tumor necrosis factor-α)and T lymphocyte subsets were compared between the 2 groups before and after treatment.Results:The healing time of oral mucosa in the OG was(6.8±1.4)d,which was significantly shorter than(8.6±1.9)d in the CG(t=4.943,P<0.01).After treatment,the grading of oral mucositis in the OG was better than that in the CG,with a statistically significant difference(Z=2.942,P<0.05).The oral pain scores of the OG was lower than that in the CG at different time points after treatment,and the difference was statistically significant(t=8.207,11.017,P<0.01).After treatment,the levels of IL-6,IL-1βand TNF-αin peripheral blood of the OG were significantly lower than those in the CG(t=5.217,2.775,4.053,P<0.01).There were statistically significant differences in CD4+,CD8+and CD4+/CD8+between the OG and the CG after treatment(t=5.692,6.093,3.658,P<0.01).Conclusion:Kangfuxin Solution combined with LLLT can significantly shorten the healing time of oral mucosal,reduce the grading of oral mucositis,relieve oral pain,reduce inflammatory response and improve the immune function of patients.展开更多
Objective: The aim of the study is to evaluate the effect of low-level laser therapy in comparison to compression bandage therapy in the treatment of venous ulcers. Subjects & Methods: This study was carried out i...Objective: The aim of the study is to evaluate the effect of low-level laser therapy in comparison to compression bandage therapy in the treatment of venous ulcers. Subjects & Methods: This study was carried out in the period from March 2013 to March 2014. The study included 40 adult patients with a diagnosis of venous ulcer classified as C6 according to the clinical classification of CEAP classification. The patients were divided into 2 groups: the first one included 20 patients treated by low-level laser therapy at the Rheumatology and Rehabilitation department, and the second group included 20 patients in whom we use four layers compression bandaging at the vascular surgery department. Results: 32 ulcers were treated in group I and 35 ulcers were treated in group II. The patients of group I were 7 (35%) females and 13 (65%) males, their age range were (24 - 56) years. The patients of group II were 11 (55%) males and 9 (45%) females;their age ranges were (32 - 50) years. Measurements of the ulcers size by (cm2) were taken at the beginning of therapy, at 1 month, at 2 months and at 3 months later on. The calculation of the area of the ulcer was done by using the graph papers to document the ulcer’s perpendicular linear dimensions. According to the size of the ulcer, some ulcers heal within 1 month (15.6%) ulcers in group I, and (28.5%) in group II. Some ulcers heal within 2 months (28%) in group I, and (37%) in group II. The remaining ulcers heal within 3 months or more which are (56%) ulcers in group I, and (34.2%) ulcers in group II. The recurrence rate of chronic venous leg ulcer in compression bandage technique used in group II was the least one as the total number of recurrent cases were 5 (25%), followed by laser therapy used in group I. Conclusion: There was no significant efficacy of the low-level laser therapy over the four layers compression technique in the management of chronic venous ulcers.展开更多
Inconel 718 superalloys deposited by laser solid forming (LSF) were heat treated with solution treatment,intermediate heat treatment (IHT) and two-stage aging treatment in sequence (SITA heat treatment).The effe...Inconel 718 superalloys deposited by laser solid forming (LSF) were heat treated with solution treatment,intermediate heat treatment (IHT) and two-stage aging treatment in sequence (SITA heat treatment).The effect of IHT temperature on microstructure,tensile property and notch sensitivity of LSFed Inconel 718 superalloy at 500 ℃ were investigated.As-deposited columnar grains have transformed to equiaxed grains and the grains were refined due to the recrystallization during the SITA heat treatment.It is found that the size and amount of δ phase dispersed at grain boundaries decreased with the increasing of IHT temperature,and δ phase disappeared when the IHT temperature reached 1 020 ℃.The ultimate tensile strength (UTS) and yield strength (YS) of smooth samples increased to a maximum when the IHT temperature reached 980 ℃ and then decreased slightly to a minimum when the IHT temperature was 1 000 ℃,and followed by slight increasing again till the IHT temperature reached 1 020 ℃,resulted from the competition of precipitation strengthening effect of γ″ and γ' phase and the grain boundary weakening effect caused by the gradual disappearance of δ phase with increasing the IHT temperature.The notch sensitivity factor (qe) decreased but still greater than 1 as the IHT temperature increased,which is attributed to the decrease of the size and amount of δ precipitation.展开更多
Injury to axons close to the neuronal bodies in the mammalian central nervous system causes a large proportion of parenting neurons to degenerate. It is known that optic nerve transection close to the eye in rodents l...Injury to axons close to the neuronal bodies in the mammalian central nervous system causes a large proportion of parenting neurons to degenerate. It is known that optic nerve transection close to the eye in rodents leads to a loss of about half of retinal ganglion cells in 1 week and about 90% in 2 weeks. Using low level laser treatment in the present study, we demonstrated that treatment with helium-neon (660 nm) laser with 15 mW power could delay retinal ganglion cell death after optic nerve axotomy in adult hamsters. The effect was most apparent in the ifrst week with a short period of treatment time (5 minutes) in which 65–66% of retinal ganglion cells survived the optic nerve axotomy whereas 45–47% of retinal ganglion cells did so in optic nerve axotomy controls. We also found that single dose and early commencement of laser irradiation were important in protecting retinal ganglion cells following optic nerve axotomy. These ifndings thus convincingly show that appropriate laser treatment may be neuroprotective to retinal gan-glion cells.展开更多
We fabricated complex microfluidic devices in silica glass by water-assisted femtosecond laser ablation and sub- sequent heat treatment. The experimental results show that after heat treatment, the diameter of the mic...We fabricated complex microfluidic devices in silica glass by water-assisted femtosecond laser ablation and sub- sequent heat treatment. The experimental results show that after heat treatment, the diameter of the microehannels is significantly reduced and the internal surface roughness is improved. The diameters of the fabricated microehannels can be modulated by changing the annealing temperature and the annealing time. During annealing, the temperature affects the diameter and shape of the protrusions in microfluidic devices very strongly, and these changes are mainly caused by uniform expansion and the action of surface tension.展开更多
The transformation induced plasticity (TRIP) steels effect occurs because of the martensitic transformation of retained austenite during plastic deformation,and it provides the steel with excellent strength and ductil...The transformation induced plasticity (TRIP) steels effect occurs because of the martensitic transformation of retained austenite during plastic deformation,and it provides the steel with excellent strength and ductility.While welding remains a vital part of auto body manufacturing,the weldability of TRIP steels is problematic,and this prevents its adoption for many applications in the automotive industry.This present work studies the effects of welding and post-weld heat treatment on the microstructure of TRIP steels.It is found that the microstructures of the fusion zone and the heat affected zone (HAZ) are changed after high-temperature heat treatment.Hardness tests revealed that fusion zone hardness decreased with increasing of temperatures in the post-weld heat treatment on the laser weld seam.The rolling performance of the welding seam and the seam of post-weld heat treatment were also studied.展开更多
Many studies have investigated the selective laser melting(SLM)of AlSi10Mg and AlSi7Mg alloys,but there are still lack of researches focused on Al-Si-Mg alloys specifically tailored for SLM.In this work,a novel high M...Many studies have investigated the selective laser melting(SLM)of AlSi10Mg and AlSi7Mg alloys,but there are still lack of researches focused on Al-Si-Mg alloys specifically tailored for SLM.In this work,a novel high Mg-content AlSi8Mg3 alloy was specifically designed for SLM.The results showed that this new alloy exhibited excellent SLM processability with a lowest porosity of 0.07%.Massive lattice distortion led to a high Vickers hardness in samples fabricated at a high laser power due to the precipitation of Mg_(2)Si nanoparticles from theα-Al matrix induced by high-intensity intrinsic heat treatment during SLM.The maximum microhardness and compressive yield strength of the alloy reached HV(211±4)and(526±12)MPa,respectively.After aging treatment at 150℃,the maximum microhardness and compressive yield strength of the samples were further improved to HV(221±4)and(577±5)MPa,respectively.These values are higher than those of most known aluminum alloys fabricated by SLM.This paper provides a new idea for optimizing the mechanical properties of Al-Si-Mg alloys fabricated using SLM.展开更多
A novel α+β titanium alloy with multi-alloying addition was designed based on the cluster formula 12[Al-Ti_(12)](AlTi_(2))+5[Al-Ti_(14)](AlV_(1.2)Mo_(0.6)Nb_(0.2))which was derived from Ti-6Al-4V.The nominal composi...A novel α+β titanium alloy with multi-alloying addition was designed based on the cluster formula 12[Al-Ti_(12)](AlTi_(2))+5[Al-Ti_(14)](AlV_(1.2)Mo_(0.6)Nb_(0.2))which was derived from Ti-6Al-4V.The nominal composition of this novel alloy was determined as Ti-6.83Al-2.28V-2.14Mo-0.69Nb-6.79Zr.In this study,the novel alloy and Ti-6Al-4V alloy samples were prepared by laser additive manufacturing.The microstructure,micro-hardness,room/high temperature tensile properties of the as-deposited samples were investigated.Compared to Ti-6Al-4V,the novel alloy has much higher room and high temperature(600℃)tensile strengths,which are 1,427.5 MPa and 642.2 MPa,respectively;however,it has a much lower elongation(3.2%)at room temperature because of the finer microstructure.To improve the elongation of the novel alloy,heat treatment was used.After solution at 960℃ or 970℃ for 1 h followed by air cooling and aging at 550℃ for 4 h followed by air cooling,a unique bi-modal microstructure which contains crab-like primaryαand residual β phase is obtained,improving the compression elongation by 80.9% compared to the as-deposited samples.The novel alloy can be used as a high-temperature and high-strength candidate for laser additive manufacturing.展开更多
BACKGROUND We have previously proved that treatment of thick/deep infantile hemangiomas (IHs) with a long-pulse Alexandrite laser was clinically effective and safe. This article aims to investigate the efficiency of l...BACKGROUND We have previously proved that treatment of thick/deep infantile hemangiomas (IHs) with a long-pulse Alexandrite laser was clinically effective and safe. This article aims to investigate the efficiency of long-pulse Alexandrite laser use in treating thick and high-risk IHs located in particular anatomic areas and provides some new data on this issue. CASE SUMMARY A two-month-old girl with a thick and high-risk IH covering most of the right labia majora was examined in this study. The infant received four treatment sessions at 4- to 6-wk intervals with a long-pulse Alexandrite laser with settings as follows: 3 ms pulse duration, 8 mm spot size, 45 to 50 J/cm2 fluences, and dynamic cooling device (DCD) spray duration of 90 ms with a delay of 80 ms. Following each of the four treatment sessions, the IH showed a remarkable reduction in thickness and size without any sign of relapse. Ten months after the last treatment, the IH had completely regressed without adverse effects. During the laser treatment, no severe side effects were observed;blistering occurred only immediately after treatment and then scabbed over the next day, gradually improving in the following days. CONCLUSION Long-pulse Alexandrite laser treatment may be considered one of the first-line noninvasive therapeutic options for the treatment of thick IH.展开更多
The ablation debris and raised rim, as well as residual stress and deep crater will be formed during the mitigation of damage site with a CO2 laser irradiation on fused silica surface, which greatly affects the laser ...The ablation debris and raised rim, as well as residual stress and deep crater will be formed during the mitigation of damage site with a CO2 laser irradiation on fused silica surface, which greatly affects the laser damage resistance of optics. In this study, the experimental study combined with numerical simulation is utilized to investigate the effect of the secondary treatment on a mitigated site by CO2laser irradiation. The results indicate that the ablation debris and the raised rim can be completely eliminated and the depth of crater can be reduced. Notable results show that the residual stress of the mitigation site after treatment will reduce two-thirds of the original stress. Finally, the elimination and the controlling mechanism of secondary treatment on the debris and raised rim, as well as the reasons for changing the profile and stress are analyzed. The results can provide a reference for the optimization treatment of mitigation sites by CO2laser secondary treatment.展开更多
AIM:To investigate the effects of diode laser treatment on ocular biometric parameters in premature infants with retinopathy of prematurity(ROP).METHODS:Premature infants who received diode laser treatment for ROP(n=6...AIM:To investigate the effects of diode laser treatment on ocular biometric parameters in premature infants with retinopathy of prematurity(ROP).METHODS:Premature infants who received diode laser treatment for ROP(n=68)and premature infants with spontaneous regressed ROP without treatment(n=50)were performed longitudinal ocular biometric measurements including anterior chamber depth,lens thickness and axial length as follows:1 d prior to laser treatment,and 3,6,9,and 12 mo after the laser treatment.RESULTS:The mean birth weight,gestational age and initial examination time values were 936.53±302.07 g,26.66±2.42 wk,36.26±2.73 wk in the treatment group and 959.78±260.08 g,27.28±2.10 wk,36.56±2.54 wk in the control group.There was no statistically significant difference in these demographic characteristics of the groups.Anterior chamber depth,lens thickness and axial length demonstrated statistically significant linear increases during the study period in the two groups(P<0.001 for each).There were no statistically significant differences between the two groups in terms of anterior chamber depth after laser treatment.Measurements of the lens thickness at 9 th and 12 th months(9 th month 3.70±0.22 vs 3.60±0.21 mm,P=0.017;12 th month 3.81±0.21 vs 3.69±0.22 mm,P=0.002)and the axial length at 12 th month(19.35±0.79 vs 19.13±0.54 mm,P=0.031)after laser treatment were statistically higher in the treatment group.CONCLUSION:Diode laser retinal photocoagulation treatment in premature infants seems to increase the lens thickness and axial length.展开更多
Single crystal silicon freestanding structures for tensile and fatigue testing were treated with KrF excimer laser to improve surface roughness and accordingly mechanical performance. Sample thickness was 5 μm. Local...Single crystal silicon freestanding structures for tensile and fatigue testing were treated with KrF excimer laser to improve surface roughness and accordingly mechanical performance. Sample thickness was 5 μm. Localized laser treatment was successful in eliminating the scallops developed during Bosch process and in reducing surface roughness. Harsh irradiation at laser energies up to 4 J/cm2 was only possible due to localized treatment without significant vibrations occurring on the freestanding samples that led to fracture in preliminary experiments at energies as low as 0.16 J/cm2. Finite element analysis was used to investigate the temperature distribution on the irradiated structures. Atomic force microscopy (AFM) and Raman spectroscopy were also used to assess surface roughness, crystallinity changes and surface stresses developing on surfaces subjected to perpendicular laser irradiation. At a high energy (3.2 J/cm2) the top surface showed a decrease of roughness compared to fabricated samples. Raman spectroscopy showed the dominance of crystalline silicon after laser irradiation. The effects of laser energy, number of展开更多
Background : Osteoporosis can make bone repair difficult. Low-level laser therapy( LLLT) has been shown to be a promising tool for bone neoformation. This study aimed to analyze the effect of LLLT on calvaria bone def...Background : Osteoporosis can make bone repair difficult. Low-level laser therapy( LLLT) has been shown to be a promising tool for bone neoformation. This study aimed to analyze the effect of LLLT on calvaria bone defects of ovariectomized rats using stereology. Methods : Fifty-four Wistar rats were subjected to bilateral ovariectomy, and bone defects were created in calvaria after 150 days. The animals were divided into nine groups(n = ?6 per group), and 24 hours after the bone defects were created they received three, six or 12 sessions of LLLT at 0, 20 or 30 J/cm 2, using a 780-nm low-intensity GaAlAs laser. One-way ANOVA followed by Tukey ' s post hoc test was used for data processing. A difference of P < 0.05 was considered statistically significant. The parameters evaluated were osteocyte density( Nv_(ost)), total osteocyte number( Nto ost), trabecular surface density( Sv_t), and trabecular surface area( Sa_t). Results : Data obtained showed that Nto ost, Sv t, and Sa t in group G2 rats were significantly different from G1(0 J/cm^2)( P < 0.05). Compared to group G4, G5 presented higher values for the parameters Sv t and Sa t, and G6 presented significantly higher values for almost all the analyzed parameters( Nv _(ost), Nto_(ost), Sv_t, and Sa t)( P < 0.05). Compared to group G7, G8 showed a higher value only for the parameter Sa t, and G9 showed significantly higher values for parameters Nv ost, Nto ost, Sv_t, and Sa_t. Conclusion : We conclude that LLLT stimulated bone neoformation and contributed to an increase in the total number of osteocytes, especially with a laser energy density of 30 J/cm^2 given for six and 12 sessions.展开更多
In this paper,the microstructures and rolling contact fatigue behaviors of laser cladding Inconel 625 coatings with or without post-heat treatments were analyzed.The results revealed that the fatigue resistance of the...In this paper,the microstructures and rolling contact fatigue behaviors of laser cladding Inconel 625 coatings with or without post-heat treatments were analyzed.The results revealed that the fatigue resistance of the laser cladding coating after any post-heat treatment was worse than that of the as-deposited coating.First,through the finite element analysis,the distribution of stress along the thickness direction of the coating was obtained,and it was concluded that the bonding interface between the coating and the matrix had little effect on the fatigue properties of the coating.Then X-ray diffraction(XRD),scanning electron microscopy(SEM)and energy dispersive spectrometry(EDS)were used to analyze the microstructure and failure morphology.The results revealed that the subsurface failure morphology of the coatings showed a consistent correlation with rolling fatigue property after different heat treatments.The TCP phase and carbides have been shown in the laser cladding coating.The coating after stress relieved annealing exhibited chain-shaped granular carbides on the grain boundaries which could accelerate crack propagation.The aging heat treatment made small amounts of Laves phase dissolved in the coating,while the dispersed phase was precipitated which could result in the formation of pores.And the solution treatment made large amounts of Laves phase dissolved,while the rod-shape brittle phases were generated which was easy to fracture and contribute to crack initiation and spalling.展开更多
Acute renal failure has a 50% - 80% mortality rate. Currently, treatment options for this life-threatening disease are limited. Low-level laser therapy (LLLT) has been found to modulate biological activity. The aim of...Acute renal failure has a 50% - 80% mortality rate. Currently, treatment options for this life-threatening disease are limited. Low-level laser therapy (LLLT) has been found to modulate biological activity. The aim of the present study was to investigate the possible beneficial effects of laser application to stem cells in the bone marrow, on the kidneys of rats that had undergone ischemia-reperfusion injury (IRI). IRI was induced by occlusion of the renal artery to 3- and 7-month-old rats for 15 or 30 minutes. In an additional experiment IRI was applied to both kidneys for 20 min each in 2-3-month-old rats. Rats were then divided randomly into two groups of control and laser-treated. Laser therapy (Ga-Al-As 810 nm, 200 mW output for 2 min) was applied to the bone marrow 1 and 7 days post-IRI to the kidneys, and rats were sacrificed 2 weeks later. Histomorphometry and immunohistochemistry were performed on kidney sections and blood markers for kidney function. Quantitative histomorphometric analysis revealed a reduction in dilatation of the renal tubules, restored structural integrity of the renal tubules, and reduced necrosis in the laser-treated rats as compared to the control, non-laser-irradiated group. C-kit positive cell density in kidneys post-IRI and laser-treatment was significantly (p = 0.015) 3.2-fold higher compared to the control group. Creatinine and blood urea nitrogen content were significantly lower in the laser-treated rats as compared to control. It is concluded that LLLT application to the bone marrow (BM) causes a significant increase in the density of mesenchymal stem cells in the kidneys post-IRI, probably by induction of stem cells in the BM, which subsequently migrate to the IRI kidney, significantly reducing the pathological features of the kidney and increasing kidney function post IRI.展开更多
文摘BACKGROUND Non-proliferative diabetic retinopathy(NPDR)poses a significant challenge in diabetes management due to its microvascular changes in the retina.Laser photocoagulation,a conventional therapy,aims to mitigate the risk of progressing to proliferative diabetic retinopathy(PDR).AIM To compare the efficacy and safety of multi-spot vs single-spot scanning panretinal laser photocoagulation in NPDR patients.METHODS Forty-nine NPDR patients(86 eyes)treated between September 2020 and July 2022 were included.They were randomly allocated into single-spot(n=23,40 eyes)and multi-spot(n=26,46 eyes)groups.Treatment outcomes,including bestcorrected visual acuity(BCVA),central macular thickness(CMT),and mean threshold sensitivity,were assessed at predetermined intervals over 12 months.Adverse reactions were also recorded.RESULTS Energy levels did not significantly differ between groups(P>0.05),but the multi-spot group exhibited lower energy density(P<0.05).BCVA and CMT improvements were noted in the multi-spot group at one-month posttreatment(P<0.05).Adverse reaction incidence was similar between groups(P>0.05).CONCLUSION While energy intensity and safety were comparable between modalities,multi-spot scanning demonstrated lower energy density and showed superior short-term improvements in BCVA and CMT for NPDR patients,with reduced laser-induced damage.
基金the Youth Project of Changzhou Health Commission,No.QN202129.
文摘BACKGROUND The prevalence of diabetes mellitus(DM)in China is high,and the base is broad.Diabetic retinopathy(DR)is a critical condition affecting the life and health of a nation and its economic development.DR is a common complication of DM.AIM To investigate the efficacy of laser photocoagulation combined with intravitreal injection of conbercept for treating macular edema.METHODS Overall,130 patients with diabetic macular edema(DME)hospitalized in The Third People’s Hospital of Changzhou from January 2019 to June 2022 were retrospectively included.According to the treatment plan,130 patients with DME were categorized into an observation and a control group,with 65 patients in each group.The control group received laser photocoagulation,and the observation group received laser photocoagulation with intravitreal injection of conbercept.Observe changes in vision,cytokines in the eye and so on.RESULTS The total efficacy rate in the observation group(93.85%)was higher than that in the control group(78.46%)(P<0.05).In both groups,the best corrected visual acuity correction effect improved after treatment,and the observation group was superior to the control group(P<0.05).Retinal thickness and central macular thickness improved after treatment,and the observation group was superior to the control group(P<0.05).The levels of vascular endothelial growth factor,interleukin-6,soluble intercellular adhesion molecule-1,and basic fibroblast growth factor in both groups improved after treatment,and the observation group was superior to the control group(P<0.05).CONCLUSION In patients with macular edema,combining laser photocoagulation and intravitreal injections of conbercept for DME is a more effective and safer strategy to improve vision,and lower intraocular cytokine levels.
基金funded by the Priority Academic Program Development of Jiangsu Higher Education Institution(Grant No.2014-37)the Jiangsu Provincial Health and Family Planning Commission(No.H201535)Orofacial Pain and TMD Research Unit,Institute of Stomatology,Affiliated Hospital of Stomatology,Nanjing Medical University,for their support
文摘Low-level laser therapy(LLLT) may have an effect on the pain associated with orthodontic treatment. The aim of this study was to evaluate the effect of LLLT on pain and somatosensory sensitization induced by orthodontic treatment. Forty individuals(12–33 years old; mean ± standard deviations: 20.8 ± 5.9 years) scheduled to receive orthodontic treatment were randomly divided into a laser group(LG) or a placebo group(PG)(1:1). The LG received LLLT(810-nm gallium-aluminium-arsenic diode laser in continuous mode with the power set at 400 mW, 2 J·cm–2) at 0 h, 2 h, 24 h, 4 d, and 7 d after treatment, and the PG received inactive treatment at the same time points. In both groups, the non-treated side served as a control. A numerical rating scale(NRS) of pain, pressure pain thresholds(PPTs), cold detection thresholds(CDTs), warmth detection thresholds(WDTs), cold pain thresholds(CPTs), and heat pain thresholds(HPTs) were tested on both sides at the gingiva and canine tooth and on the hand. The data were analysed by a repeated measures analysis of variance(ANOVA). The NRS pain scores were significantly lower in the LG group(P = 0.01). The CDTs,CPTs, WDTs, HPTs, and PPTs at the gingiva and the PPTs at the canine tooth were significantly less sensitive on the treatment side of the LG compared with that of the PG(P < 0.033). The parameters tested also showed significantly less sensitivity on the nontreatment side of the LG compared to that of the PG(P < 0.043). There were no differences between the groups for any quantitative sensory testing(QST) measures of the hand. The application of LLLT appears to reduce the pain and sensitivity of the tooth and gingiva associated with orthodontic treatment and may have contralateral effects within the trigeminal system but no generalized QST effects. Thus, the present study indicated a significant analgesia effect of LLLT application during orthodontic treatment.Further clinical applications are suggested.
基金Supported by Natural Science Foundation of Sichuan Province of China,No.2022NSFSC1400Youth Innovation Project of Sichuan Medical Association,No.Q15045。
文摘BACKGROUND Selective laser trabeculoplasty(SLT)is a relatively safe and effective therapy in lowering intraocular pressures(IOP)for glaucoma.AIM To study the long-term effects of SLT on IOP and number of glaucoma medications used in Chinese eyes.METHODS This is a retrospective study in which 75 eyes of 70 patients with open-angle glaucoma(OAG,n=36)and eyes with prior glaucoma surgery(PGS,n=39)were included.Changes in mean IOP and number of glaucoma medications used evaluated at 1 d,1 wk,1 mo,3 mo,6 mo,12 mo,and 36 mo after laser treatment.RESULTS All patients(33 male,37 female)were Chinese.The mean age was 44.34±16.14years.Mean pre-SLT IOP was 22.75±2.08 mmHg in OAG and 22.52±2.62 mmHg in PGS.Mean IOP was significantly reduced 1 d,1 wk,1 mo and 3 mo after laser treatment(P<0.05,respectively).Whereas,there were no significant differences between baseline and SLT treated groups at the 6th month both in OAG(P=0.347,P>0.05)and in PGS(P=0.309,P>0.05).Six months after SLT treatment,some patients received retreatment of SLT or were given more topical IOP-lowering medication to control the IOP.By the end of our study,the average IOP decreased to 20.73±1.82 mmHg in OAG and 20.49±1.53 mmHg in PGS groups.The number of glaucoma medications used was significantly reduced until the end of 3 years compared to baseline.CONCLUSION SLT could reduce IOP as adjunctive treatment both in OAG and PGS groups.SLT significantly reduced the number of glaucoma medications used 3-years following treatment in glaucoma patients.
基金the Excellent Talents Fund Project of Xuzhou Medical University,No.XYFY2021019.
文摘BACKGROUND Varicosis is a common venous condition,which is typically treated surgically.However,selection of the optimal surgical approach can be challenging.Previous studies comparing endovenous laser treatment(EVLT)and conventional surgery were retrospective and observational in nature and the results may therefore have been influenced by selection bias and the presence of other confounding factors.In this study,we used propensity score matching to reduce selection bias when comparing EVLT and conventional surgery for the treatment of varicose great saphenous veins.METHODS We retrospectively reviewed the records of 1063 patients treated for primary varicosis of the great saphenous vein at the Second Affiliated Hospital of Xuzhou Medical University between January 2009 and December 2019.Among them,56 patients were excluded owing to additional small saphenous varicose vein involvement,81 owing to recurring varicose veins,83 owing to complicated varicose veins(CEAP clinical classification C5-C6),and 6 owing to perioperative phlebitis.Finally,772 patients were enrolled in this study.Standard demographic and clinicopathological data were collected from the medical records of the patients.For propensity score matching,522 patients(261 who underwent EVLT and 261 who underwent conventional surgery)were randomly matched 1:1 by age,sex,onset time,smoking status,presence of diabetes,family history,stress therapy,C class,and the affected leg.RESULTS Of the 772 patients included in the study,467 underwent EVLT and 305 underwent conventional surgery.There were significant differences in age,onset time,smoking and diabetes status,and family history between the two groups.Following propensity score matching,no significant differences in patients’characteristics remained between the two groups.ELVT was associated with a shorter operation time and hospital stay than conventional surgery,both before and after propensity score matching.There were no differences in complications between the two groups after propensity score matching.Patients who underwent EVLT had a higher recurrence rate during the two-year follow-up period than those who underwent conventional surgery(33.33%vs 21.46%,χ^(2)=11.506,P=0.001),and a greater percentage of patients who underwent EVLT experienced pain one week after the procedure(39.85%vs 19.54%,P=0.000).CONCLUSION EVLT may not always be the best option for the treatment of great saphenous vein varicosis.
文摘Objective:To investigate the effect of Kangfuxin Solution(康复新液)combined with low-level laser therapy(LLLT)on cytokines and immune function in patients with radiation-induced oral mucositis.Methods:There were 84 nasopharyngeal carcinoma patients with oral mucositis after intensity-modulated radiation therapy(IMRT)were randomly divided into the control group(CG)and the observation group(OG),with 42 cases in each group.The CG was given LLLT,and the OG was treated with Kangfuxin Solution in addition to LLLT for 10 consecutive days.The healing time of oral mucosa,mucositis grading,oral pain scores,cytokines(interleukin-6,interleukin-1βand tumor necrosis factor-α)and T lymphocyte subsets were compared between the 2 groups before and after treatment.Results:The healing time of oral mucosa in the OG was(6.8±1.4)d,which was significantly shorter than(8.6±1.9)d in the CG(t=4.943,P<0.01).After treatment,the grading of oral mucositis in the OG was better than that in the CG,with a statistically significant difference(Z=2.942,P<0.05).The oral pain scores of the OG was lower than that in the CG at different time points after treatment,and the difference was statistically significant(t=8.207,11.017,P<0.01).After treatment,the levels of IL-6,IL-1βand TNF-αin peripheral blood of the OG were significantly lower than those in the CG(t=5.217,2.775,4.053,P<0.01).There were statistically significant differences in CD4+,CD8+and CD4+/CD8+between the OG and the CG after treatment(t=5.692,6.093,3.658,P<0.01).Conclusion:Kangfuxin Solution combined with LLLT can significantly shorten the healing time of oral mucosal,reduce the grading of oral mucositis,relieve oral pain,reduce inflammatory response and improve the immune function of patients.
文摘Objective: The aim of the study is to evaluate the effect of low-level laser therapy in comparison to compression bandage therapy in the treatment of venous ulcers. Subjects & Methods: This study was carried out in the period from March 2013 to March 2014. The study included 40 adult patients with a diagnosis of venous ulcer classified as C6 according to the clinical classification of CEAP classification. The patients were divided into 2 groups: the first one included 20 patients treated by low-level laser therapy at the Rheumatology and Rehabilitation department, and the second group included 20 patients in whom we use four layers compression bandaging at the vascular surgery department. Results: 32 ulcers were treated in group I and 35 ulcers were treated in group II. The patients of group I were 7 (35%) females and 13 (65%) males, their age range were (24 - 56) years. The patients of group II were 11 (55%) males and 9 (45%) females;their age ranges were (32 - 50) years. Measurements of the ulcers size by (cm2) were taken at the beginning of therapy, at 1 month, at 2 months and at 3 months later on. The calculation of the area of the ulcer was done by using the graph papers to document the ulcer’s perpendicular linear dimensions. According to the size of the ulcer, some ulcers heal within 1 month (15.6%) ulcers in group I, and (28.5%) in group II. Some ulcers heal within 2 months (28%) in group I, and (37%) in group II. The remaining ulcers heal within 3 months or more which are (56%) ulcers in group I, and (34.2%) ulcers in group II. The recurrence rate of chronic venous leg ulcer in compression bandage technique used in group II was the least one as the total number of recurrent cases were 5 (25%), followed by laser therapy used in group I. Conclusion: There was no significant efficacy of the low-level laser therapy over the four layers compression technique in the management of chronic venous ulcers.
基金Funded by the Program for New Century Excellent Talents in University of China (No.NCET-06-0879)the National Natural Science Foundation of China (NSFC) (No.50971102)+2 种基金NPU Foundation for Fundamental Research(No.NPU-FFR-JC200808)the Fund of the State Key Laboratory of Solidification Processing (NPU) (Nos.16-TZ-2007 and 39-QZ-2009)supported by the Program of Introducing Talents of Discipline to Universities (No.08040)
文摘Inconel 718 superalloys deposited by laser solid forming (LSF) were heat treated with solution treatment,intermediate heat treatment (IHT) and two-stage aging treatment in sequence (SITA heat treatment).The effect of IHT temperature on microstructure,tensile property and notch sensitivity of LSFed Inconel 718 superalloy at 500 ℃ were investigated.As-deposited columnar grains have transformed to equiaxed grains and the grains were refined due to the recrystallization during the SITA heat treatment.It is found that the size and amount of δ phase dispersed at grain boundaries decreased with the increasing of IHT temperature,and δ phase disappeared when the IHT temperature reached 1 020 ℃.The ultimate tensile strength (UTS) and yield strength (YS) of smooth samples increased to a maximum when the IHT temperature reached 980 ℃ and then decreased slightly to a minimum when the IHT temperature was 1 000 ℃,and followed by slight increasing again till the IHT temperature reached 1 020 ℃,resulted from the competition of precipitation strengthening effect of γ″ and γ' phase and the grain boundary weakening effect caused by the gradual disappearance of δ phase with increasing the IHT temperature.The notch sensitivity factor (qe) decreased but still greater than 1 as the IHT temperature increased,which is attributed to the decrease of the size and amount of δ precipitation.
基金supported by Key Basic Research Project of China(973 Program),No.2011CB707501Fundamental Research Funds for The Central Universities,No.21609101
文摘Injury to axons close to the neuronal bodies in the mammalian central nervous system causes a large proportion of parenting neurons to degenerate. It is known that optic nerve transection close to the eye in rodents leads to a loss of about half of retinal ganglion cells in 1 week and about 90% in 2 weeks. Using low level laser treatment in the present study, we demonstrated that treatment with helium-neon (660 nm) laser with 15 mW power could delay retinal ganglion cell death after optic nerve axotomy in adult hamsters. The effect was most apparent in the ifrst week with a short period of treatment time (5 minutes) in which 65–66% of retinal ganglion cells survived the optic nerve axotomy whereas 45–47% of retinal ganglion cells did so in optic nerve axotomy controls. We also found that single dose and early commencement of laser irradiation were important in protecting retinal ganglion cells following optic nerve axotomy. These ifndings thus convincingly show that appropriate laser treatment may be neuroprotective to retinal gan-glion cells.
基金Project supported by the Science and Technology Foundation of Heilongjiang Province,China (Grant No. A200912)the Program of Excellence Team in the Harbin Institute of Technology,China
文摘We fabricated complex microfluidic devices in silica glass by water-assisted femtosecond laser ablation and sub- sequent heat treatment. The experimental results show that after heat treatment, the diameter of the microehannels is significantly reduced and the internal surface roughness is improved. The diameters of the fabricated microehannels can be modulated by changing the annealing temperature and the annealing time. During annealing, the temperature affects the diameter and shape of the protrusions in microfluidic devices very strongly, and these changes are mainly caused by uniform expansion and the action of surface tension.
文摘The transformation induced plasticity (TRIP) steels effect occurs because of the martensitic transformation of retained austenite during plastic deformation,and it provides the steel with excellent strength and ductility.While welding remains a vital part of auto body manufacturing,the weldability of TRIP steels is problematic,and this prevents its adoption for many applications in the automotive industry.This present work studies the effects of welding and post-weld heat treatment on the microstructure of TRIP steels.It is found that the microstructures of the fusion zone and the heat affected zone (HAZ) are changed after high-temperature heat treatment.Hardness tests revealed that fusion zone hardness decreased with increasing of temperatures in the post-weld heat treatment on the laser weld seam.The rolling performance of the welding seam and the seam of post-weld heat treatment were also studied.
基金financially supported by the the National Natural Science Foundation of China(Nos.51801079 and 52001140)the Natural Science Foundation for Young Scientists of Jiangsu,China(Nos.BK20180985 and BK20180987)the Open Foundation of Zhenjiang Key Laboratory for High Technology Research on Marine Functional Films(No.ZHZ2019001)。
文摘Many studies have investigated the selective laser melting(SLM)of AlSi10Mg and AlSi7Mg alloys,but there are still lack of researches focused on Al-Si-Mg alloys specifically tailored for SLM.In this work,a novel high Mg-content AlSi8Mg3 alloy was specifically designed for SLM.The results showed that this new alloy exhibited excellent SLM processability with a lowest porosity of 0.07%.Massive lattice distortion led to a high Vickers hardness in samples fabricated at a high laser power due to the precipitation of Mg_(2)Si nanoparticles from theα-Al matrix induced by high-intensity intrinsic heat treatment during SLM.The maximum microhardness and compressive yield strength of the alloy reached HV(211±4)and(526±12)MPa,respectively.After aging treatment at 150℃,the maximum microhardness and compressive yield strength of the samples were further improved to HV(221±4)and(577±5)MPa,respectively.These values are higher than those of most known aluminum alloys fabricated by SLM.This paper provides a new idea for optimizing the mechanical properties of Al-Si-Mg alloys fabricated using SLM.
基金financially supported by the Shenyang Young and Middle-aged Scientific and Technological Innovation Talents Program(RC190490)the Liaoning Revitalization Talents Program(No.XLYC1808030)。
文摘A novel α+β titanium alloy with multi-alloying addition was designed based on the cluster formula 12[Al-Ti_(12)](AlTi_(2))+5[Al-Ti_(14)](AlV_(1.2)Mo_(0.6)Nb_(0.2))which was derived from Ti-6Al-4V.The nominal composition of this novel alloy was determined as Ti-6.83Al-2.28V-2.14Mo-0.69Nb-6.79Zr.In this study,the novel alloy and Ti-6Al-4V alloy samples were prepared by laser additive manufacturing.The microstructure,micro-hardness,room/high temperature tensile properties of the as-deposited samples were investigated.Compared to Ti-6Al-4V,the novel alloy has much higher room and high temperature(600℃)tensile strengths,which are 1,427.5 MPa and 642.2 MPa,respectively;however,it has a much lower elongation(3.2%)at room temperature because of the finer microstructure.To improve the elongation of the novel alloy,heat treatment was used.After solution at 960℃ or 970℃ for 1 h followed by air cooling and aging at 550℃ for 4 h followed by air cooling,a unique bi-modal microstructure which contains crab-like primaryαand residual β phase is obtained,improving the compression elongation by 80.9% compared to the as-deposited samples.The novel alloy can be used as a high-temperature and high-strength candidate for laser additive manufacturing.
基金Supported by Zhejiang Provincial Natural Science Foundation of China,No.LQ16H110001 and No.LQ13C100001Wenzhou Science and Technology Bureau Foundation,No.2017Y0750Medicine and Health Science and Technology Projects of Zhejiang Province of China,No.2013KYA128
文摘BACKGROUND We have previously proved that treatment of thick/deep infantile hemangiomas (IHs) with a long-pulse Alexandrite laser was clinically effective and safe. This article aims to investigate the efficiency of long-pulse Alexandrite laser use in treating thick and high-risk IHs located in particular anatomic areas and provides some new data on this issue. CASE SUMMARY A two-month-old girl with a thick and high-risk IH covering most of the right labia majora was examined in this study. The infant received four treatment sessions at 4- to 6-wk intervals with a long-pulse Alexandrite laser with settings as follows: 3 ms pulse duration, 8 mm spot size, 45 to 50 J/cm2 fluences, and dynamic cooling device (DCD) spray duration of 90 ms with a delay of 80 ms. Following each of the four treatment sessions, the IH showed a remarkable reduction in thickness and size without any sign of relapse. Ten months after the last treatment, the IH had completely regressed without adverse effects. During the laser treatment, no severe side effects were observed;blistering occurred only immediately after treatment and then scabbed over the next day, gradually improving in the following days. CONCLUSION Long-pulse Alexandrite laser treatment may be considered one of the first-line noninvasive therapeutic options for the treatment of thick IH.
基金supported by the National Natural Science Foundation of China(Grant Nos.61505170,61505171,and 51535003)the Joint Fund of the National Natural Science Foundation of China+1 种基金the Chinese Academy of Engineering Physics(Grant No.U1530109)the China Postdoctoral Science Foundation(Grant No.2016M592709)
文摘The ablation debris and raised rim, as well as residual stress and deep crater will be formed during the mitigation of damage site with a CO2 laser irradiation on fused silica surface, which greatly affects the laser damage resistance of optics. In this study, the experimental study combined with numerical simulation is utilized to investigate the effect of the secondary treatment on a mitigated site by CO2laser irradiation. The results indicate that the ablation debris and the raised rim can be completely eliminated and the depth of crater can be reduced. Notable results show that the residual stress of the mitigation site after treatment will reduce two-thirds of the original stress. Finally, the elimination and the controlling mechanism of secondary treatment on the debris and raised rim, as well as the reasons for changing the profile and stress are analyzed. The results can provide a reference for the optimization treatment of mitigation sites by CO2laser secondary treatment.
文摘AIM:To investigate the effects of diode laser treatment on ocular biometric parameters in premature infants with retinopathy of prematurity(ROP).METHODS:Premature infants who received diode laser treatment for ROP(n=68)and premature infants with spontaneous regressed ROP without treatment(n=50)were performed longitudinal ocular biometric measurements including anterior chamber depth,lens thickness and axial length as follows:1 d prior to laser treatment,and 3,6,9,and 12 mo after the laser treatment.RESULTS:The mean birth weight,gestational age and initial examination time values were 936.53±302.07 g,26.66±2.42 wk,36.26±2.73 wk in the treatment group and 959.78±260.08 g,27.28±2.10 wk,36.56±2.54 wk in the control group.There was no statistically significant difference in these demographic characteristics of the groups.Anterior chamber depth,lens thickness and axial length demonstrated statistically significant linear increases during the study period in the two groups(P<0.001 for each).There were no statistically significant differences between the two groups in terms of anterior chamber depth after laser treatment.Measurements of the lens thickness at 9 th and 12 th months(9 th month 3.70±0.22 vs 3.60±0.21 mm,P=0.017;12 th month 3.81±0.21 vs 3.69±0.22 mm,P=0.002)and the axial length at 12 th month(19.35±0.79 vs 19.13±0.54 mm,P=0.031)after laser treatment were statistically higher in the treatment group.CONCLUSION:Diode laser retinal photocoagulation treatment in premature infants seems to increase the lens thickness and axial length.
文摘Single crystal silicon freestanding structures for tensile and fatigue testing were treated with KrF excimer laser to improve surface roughness and accordingly mechanical performance. Sample thickness was 5 μm. Localized laser treatment was successful in eliminating the scallops developed during Bosch process and in reducing surface roughness. Harsh irradiation at laser energies up to 4 J/cm2 was only possible due to localized treatment without significant vibrations occurring on the freestanding samples that led to fracture in preliminary experiments at energies as low as 0.16 J/cm2. Finite element analysis was used to investigate the temperature distribution on the irradiated structures. Atomic force microscopy (AFM) and Raman spectroscopy were also used to assess surface roughness, crystallinity changes and surface stresses developing on surfaces subjected to perpendicular laser irradiation. At a high energy (3.2 J/cm2) the top surface showed a decrease of roughness compared to fabricated samples. Raman spectroscopy showed the dominance of crystalline silicon after laser irradiation. The effects of laser energy, number of
基金FAPESP(Sao Paulo Research Foundation),Grant/Award Number:2011/50686-0National Institute and Technology-Translational Medicine(INCT.TM)CNPq(National Council for Scientific and Technological Development)
文摘Background : Osteoporosis can make bone repair difficult. Low-level laser therapy( LLLT) has been shown to be a promising tool for bone neoformation. This study aimed to analyze the effect of LLLT on calvaria bone defects of ovariectomized rats using stereology. Methods : Fifty-four Wistar rats were subjected to bilateral ovariectomy, and bone defects were created in calvaria after 150 days. The animals were divided into nine groups(n = ?6 per group), and 24 hours after the bone defects were created they received three, six or 12 sessions of LLLT at 0, 20 or 30 J/cm 2, using a 780-nm low-intensity GaAlAs laser. One-way ANOVA followed by Tukey ' s post hoc test was used for data processing. A difference of P < 0.05 was considered statistically significant. The parameters evaluated were osteocyte density( Nv_(ost)), total osteocyte number( Nto ost), trabecular surface density( Sv_t), and trabecular surface area( Sa_t). Results : Data obtained showed that Nto ost, Sv t, and Sa t in group G2 rats were significantly different from G1(0 J/cm^2)( P < 0.05). Compared to group G4, G5 presented higher values for the parameters Sv t and Sa t, and G6 presented significantly higher values for almost all the analyzed parameters( Nv _(ost), Nto_(ost), Sv_t, and Sa t)( P < 0.05). Compared to group G7, G8 showed a higher value only for the parameter Sa t, and G9 showed significantly higher values for parameters Nv ost, Nto ost, Sv_t, and Sa_t. Conclusion : We conclude that LLLT stimulated bone neoformation and contributed to an increase in the total number of osteocytes, especially with a laser energy density of 30 J/cm^2 given for six and 12 sessions.
基金This work was financially supported by the National Natural Science Foundation of China(No.51875425)Open Fund of Shandong Key Laboratory of Corrosion Science(No.KLCS201907).
文摘In this paper,the microstructures and rolling contact fatigue behaviors of laser cladding Inconel 625 coatings with or without post-heat treatments were analyzed.The results revealed that the fatigue resistance of the laser cladding coating after any post-heat treatment was worse than that of the as-deposited coating.First,through the finite element analysis,the distribution of stress along the thickness direction of the coating was obtained,and it was concluded that the bonding interface between the coating and the matrix had little effect on the fatigue properties of the coating.Then X-ray diffraction(XRD),scanning electron microscopy(SEM)and energy dispersive spectrometry(EDS)were used to analyze the microstructure and failure morphology.The results revealed that the subsurface failure morphology of the coatings showed a consistent correlation with rolling fatigue property after different heat treatments.The TCP phase and carbides have been shown in the laser cladding coating.The coating after stress relieved annealing exhibited chain-shaped granular carbides on the grain boundaries which could accelerate crack propagation.The aging heat treatment made small amounts of Laves phase dissolved in the coating,while the dispersed phase was precipitated which could result in the formation of pores.And the solution treatment made large amounts of Laves phase dissolved,while the rod-shape brittle phases were generated which was easy to fracture and contribute to crack initiation and spalling.
文摘Acute renal failure has a 50% - 80% mortality rate. Currently, treatment options for this life-threatening disease are limited. Low-level laser therapy (LLLT) has been found to modulate biological activity. The aim of the present study was to investigate the possible beneficial effects of laser application to stem cells in the bone marrow, on the kidneys of rats that had undergone ischemia-reperfusion injury (IRI). IRI was induced by occlusion of the renal artery to 3- and 7-month-old rats for 15 or 30 minutes. In an additional experiment IRI was applied to both kidneys for 20 min each in 2-3-month-old rats. Rats were then divided randomly into two groups of control and laser-treated. Laser therapy (Ga-Al-As 810 nm, 200 mW output for 2 min) was applied to the bone marrow 1 and 7 days post-IRI to the kidneys, and rats were sacrificed 2 weeks later. Histomorphometry and immunohistochemistry were performed on kidney sections and blood markers for kidney function. Quantitative histomorphometric analysis revealed a reduction in dilatation of the renal tubules, restored structural integrity of the renal tubules, and reduced necrosis in the laser-treated rats as compared to the control, non-laser-irradiated group. C-kit positive cell density in kidneys post-IRI and laser-treatment was significantly (p = 0.015) 3.2-fold higher compared to the control group. Creatinine and blood urea nitrogen content were significantly lower in the laser-treated rats as compared to control. It is concluded that LLLT application to the bone marrow (BM) causes a significant increase in the density of mesenchymal stem cells in the kidneys post-IRI, probably by induction of stem cells in the BM, which subsequently migrate to the IRI kidney, significantly reducing the pathological features of the kidney and increasing kidney function post IRI.