期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Determination of Camylofin Dihydrochloride and Nimesulide in Pharmaceutical Preparation by Gas Chromatography
1
作者 Rajeev Kumar R. Singh Manapragada V. Rathnam +1 位作者 Sangeeta J. Singh Raju V. K. Vegesna 《American Journal of Analytical Chemistry》 2011年第8期944-952,共9页
This research paper describes simple analytical method for determination of Camylofin dihydrochloride and Nimesulide in tablet formulation by Gas chromatography method. Benzoic acid was used as internal standard. Vali... This research paper describes simple analytical method for determination of Camylofin dihydrochloride and Nimesulide in tablet formulation by Gas chromatography method. Benzoic acid was used as internal standard. Validation was carried out in compliance with the International Conference on Harmonization guidelines. The method utilized GC (Agilent Technologies 6890 N Network GC system with FID detector), and RTX-5 capillary column (5% diphenyl-95% dimethyl polysiloxane), 30 m × 0.53 mm, 1.5 μm as stationary phase. Helium was used as the carrier gas at a flow rate of 1.5 mL?min–1. The proposed method was validated for linearity, LOD, LOQ, accuracy, precision, ruggedness and solution stability. It can be conveniently adopted for routine quality control analysis. 展开更多
关键词 CAPILLARY column gas chromatography PHARMACEUTICAL Preparations Camylofin Dihydrochloride NIMESULIDE
下载PDF
A modified simplex method for multifactor optimization of selectivity in gas chromatography
2
作者 WANG, QS ZHU, CS YAN, BW 《Chinese Journal of Chemistry》 SCIE CAS CSCD 1995年第2期169-174,共6页
A computer-assisted advanced simplex method is presented for the simultaneous optimization of multifactor (stationary phase loading, carrier gas dow rate and column temperature) for separation of ten compounds in gas ... A computer-assisted advanced simplex method is presented for the simultaneous optimization of multifactor (stationary phase loading, carrier gas dow rate and column temperature) for separation of ten compounds in gas chromatography. A three factors factorial design was used. The method was based on a special polynomial established from fifteen preliminary runs, using resolution as the selection criterion, with connection to a general simplex method. Excellent agreement is found between the predicted data and the experimental results, and most of experiments required in the general simplex method can be omitted. 展开更多
关键词 gas chromatography STATIONARY PHASE CARRIER gas FLOW RATE column TEMPERATURE MULTIFACTOR OPTIMIZATION
原文传递
A validated, related substance, GC method for 1,4-cyclohexanedione mono-ethylene Ketal
3
作者 B. Karthikeyan V. Srinivasan 《Journal of Biophysical Chemistry》 2010年第1期72-75,共4页
ABSTRACT A simple, economic, and time-efficient related substance, GC method has been developed for the analysis of 1,4-Cyclohexanedione mono- ethylene ketal(will be specified as ketal) in the presence of a potential ... ABSTRACT A simple, economic, and time-efficient related substance, GC method has been developed for the analysis of 1,4-Cyclohexanedione mono- ethylene ketal(will be specified as ketal) in the presence of a potential impurity 1,4-cyclohexa- nedione bis (ethylene ketal) [will be specified as diketal]. Successful chromatographic separa- tion of the ketal from the impurity was achieved on a DBWAX ETR, 30 m x 0.32 mm x 1.0μ FT column with nitrogen as carrier gas and FID detector. The method was validated for linearity, accuracy, precision, and specificity and can be used for quality control during manufacture of ketal. A validated GC method is reported for the ketal for the first time. 展开更多
关键词 column gas chromatography 1 4-Cyclohexanedione Mono-Ethylene KETAL 4-Cyclohexanedione BIS (Ethylene Ketal) Validation
下载PDF
Implicit characteristic parameter of a programmed temperature retention index database
4
作者 孙亦梁 黄爱今 +1 位作者 王青清 韦平 《Science China Chemistry》 SCIE EI CAS 1996年第3期308-317,共10页
In a programmed temperature retention index (PTRI) database, there exists a characteristic parameter rt0/β that can be calculated if the experimental parameters are clearly given. This characteristic parameter can be... In a programmed temperature retention index (PTRI) database, there exists a characteristic parameter rt0/β that can be calculated if the experimental parameters are clearly given. This characteristic parameter can be used to flexibly reproduce the original PTRI data under chromatographic conditions different from those originally given. As this characteristic parameter is not explicitly given, it is suggested to name this parameter as the implicit characteristic parameter (TCP) of a PTRI database. The ICP in White’s PTRI database was easily found and used satisfactorily to reproduce PTRI of some test compounds using either a Hewlett-Packard ultra-performance OV-1 column or a self-coated OV-1 column. The reproduction of PTRI could not be realized on columns of different materials. The fact that several PTRI databases measured on glass capillary columns could not satisfactorily be reproduced on fused silica column is explained. 展开更多
关键词 programmed TEMPERATURE gas chromatography programmed TEMPERATURE RETENTION index database REPRODUCIBILITY influence af column materials.
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部