This research paper describes simple analytical method for determination of Camylofin dihydrochloride and Nimesulide in tablet formulation by Gas chromatography method. Benzoic acid was used as internal standard. Vali...This research paper describes simple analytical method for determination of Camylofin dihydrochloride and Nimesulide in tablet formulation by Gas chromatography method. Benzoic acid was used as internal standard. Validation was carried out in compliance with the International Conference on Harmonization guidelines. The method utilized GC (Agilent Technologies 6890 N Network GC system with FID detector), and RTX-5 capillary column (5% diphenyl-95% dimethyl polysiloxane), 30 m × 0.53 mm, 1.5 μm as stationary phase. Helium was used as the carrier gas at a flow rate of 1.5 mL?min–1. The proposed method was validated for linearity, LOD, LOQ, accuracy, precision, ruggedness and solution stability. It can be conveniently adopted for routine quality control analysis.展开更多
A computer-assisted advanced simplex method is presented for the simultaneous optimization of multifactor (stationary phase loading, carrier gas dow rate and column temperature) for separation of ten compounds in gas ...A computer-assisted advanced simplex method is presented for the simultaneous optimization of multifactor (stationary phase loading, carrier gas dow rate and column temperature) for separation of ten compounds in gas chromatography. A three factors factorial design was used. The method was based on a special polynomial established from fifteen preliminary runs, using resolution as the selection criterion, with connection to a general simplex method. Excellent agreement is found between the predicted data and the experimental results, and most of experiments required in the general simplex method can be omitted.展开更多
ABSTRACT A simple, economic, and time-efficient related substance, GC method has been developed for the analysis of 1,4-Cyclohexanedione mono- ethylene ketal(will be specified as ketal) in the presence of a potential ...ABSTRACT A simple, economic, and time-efficient related substance, GC method has been developed for the analysis of 1,4-Cyclohexanedione mono- ethylene ketal(will be specified as ketal) in the presence of a potential impurity 1,4-cyclohexa- nedione bis (ethylene ketal) [will be specified as diketal]. Successful chromatographic separa- tion of the ketal from the impurity was achieved on a DBWAX ETR, 30 m x 0.32 mm x 1.0μ FT column with nitrogen as carrier gas and FID detector. The method was validated for linearity, accuracy, precision, and specificity and can be used for quality control during manufacture of ketal. A validated GC method is reported for the ketal for the first time.展开更多
In a programmed temperature retention index (PTRI) database, there exists a characteristic parameter rt0/β that can be calculated if the experimental parameters are clearly given. This characteristic parameter can be...In a programmed temperature retention index (PTRI) database, there exists a characteristic parameter rt0/β that can be calculated if the experimental parameters are clearly given. This characteristic parameter can be used to flexibly reproduce the original PTRI data under chromatographic conditions different from those originally given. As this characteristic parameter is not explicitly given, it is suggested to name this parameter as the implicit characteristic parameter (TCP) of a PTRI database. The ICP in White’s PTRI database was easily found and used satisfactorily to reproduce PTRI of some test compounds using either a Hewlett-Packard ultra-performance OV-1 column or a self-coated OV-1 column. The reproduction of PTRI could not be realized on columns of different materials. The fact that several PTRI databases measured on glass capillary columns could not satisfactorily be reproduced on fused silica column is explained.展开更多
文摘This research paper describes simple analytical method for determination of Camylofin dihydrochloride and Nimesulide in tablet formulation by Gas chromatography method. Benzoic acid was used as internal standard. Validation was carried out in compliance with the International Conference on Harmonization guidelines. The method utilized GC (Agilent Technologies 6890 N Network GC system with FID detector), and RTX-5 capillary column (5% diphenyl-95% dimethyl polysiloxane), 30 m × 0.53 mm, 1.5 μm as stationary phase. Helium was used as the carrier gas at a flow rate of 1.5 mL?min–1. The proposed method was validated for linearity, LOD, LOQ, accuracy, precision, ruggedness and solution stability. It can be conveniently adopted for routine quality control analysis.
基金supported by the National Natural Science Foundation of China.
文摘A computer-assisted advanced simplex method is presented for the simultaneous optimization of multifactor (stationary phase loading, carrier gas dow rate and column temperature) for separation of ten compounds in gas chromatography. A three factors factorial design was used. The method was based on a special polynomial established from fifteen preliminary runs, using resolution as the selection criterion, with connection to a general simplex method. Excellent agreement is found between the predicted data and the experimental results, and most of experiments required in the general simplex method can be omitted.
文摘ABSTRACT A simple, economic, and time-efficient related substance, GC method has been developed for the analysis of 1,4-Cyclohexanedione mono- ethylene ketal(will be specified as ketal) in the presence of a potential impurity 1,4-cyclohexa- nedione bis (ethylene ketal) [will be specified as diketal]. Successful chromatographic separa- tion of the ketal from the impurity was achieved on a DBWAX ETR, 30 m x 0.32 mm x 1.0μ FT column with nitrogen as carrier gas and FID detector. The method was validated for linearity, accuracy, precision, and specificity and can be used for quality control during manufacture of ketal. A validated GC method is reported for the ketal for the first time.
基金Project supported by the National Natural Science Foundation of China
文摘In a programmed temperature retention index (PTRI) database, there exists a characteristic parameter rt0/β that can be calculated if the experimental parameters are clearly given. This characteristic parameter can be used to flexibly reproduce the original PTRI data under chromatographic conditions different from those originally given. As this characteristic parameter is not explicitly given, it is suggested to name this parameter as the implicit characteristic parameter (TCP) of a PTRI database. The ICP in White’s PTRI database was easily found and used satisfactorily to reproduce PTRI of some test compounds using either a Hewlett-Packard ultra-performance OV-1 column or a self-coated OV-1 column. The reproduction of PTRI could not be realized on columns of different materials. The fact that several PTRI databases measured on glass capillary columns could not satisfactorily be reproduced on fused silica column is explained.