期刊文献+
共找到11,313篇文章
< 1 2 250 >
每页显示 20 50 100
Minimization of Electric Power Losses on 132 kV and 220 kV Uganda Electricity Transmission Lines
1
作者 Ounyesiga Living Stephen Ndubuisi Nnamchi +2 位作者 Kelechi John Ukagwu Abubakar Abdulkarim Zaid Oluwadurotimi Jagun 《Energy and Power Engineering》 CAS 2023年第2期127-150,共24页
The classical minimization of power losses in transmission lines is dominated by artificial intelligence techniques, which do not guarantee global optimum amidst local minima. Revolutionary and evolutionary techniques... The classical minimization of power losses in transmission lines is dominated by artificial intelligence techniques, which do not guarantee global optimum amidst local minima. Revolutionary and evolutionary techniques are encumbered with sophisticated transformations, which weaken the techniques. Power loss minimization is crucial to the efficient design and operation of power transmission lines. Minimization of losses is one way to meet steady grid supply, especially at peak demand. Thus, this paper has presented a gradient technique to obtain optimal variables and values from the power loss model, which efficiently minimizes power losses by modifying the traditional power loss model that combines Ohm and Corona losses. Optimality tests showed that the unmodified model does not support the minimization of power losses on transmission lines as the Hessian matrix portrayed the maximization of power losses. However, the modified model is consistent with the gradient method of optimization, which yielded optimum variables and values from the power loss model developed in this study. The unmodified (modified) models for Bujagali-Kawanda 220 kV and Masaka West-Mbarara North 132 kV transmission lines in Uganda showed maximum power losses of 0.406 (0.391) and 0.452 (0.446) kW/km/phase respectively. These results indicate that the modified model is superior to the unmodified model in minimizing power losses in the transmission lines and should be implemented for the efficient design and operation of power transmission lines within and outside Uganda for the same transmission voltages. 展开更多
关键词 MINIMIZATION power Losses Transmission lines Corona and Ohms Losses Transmission Model
下载PDF
A Miniaturized Broadband Wilkinson Power Divider Using Micro-Strip Branch Lines
2
作者 Taifu Zhou 《Journal of Computer and Communications》 2023年第12期102-108,共7页
A miniaturized broadband Wilkinson power divider is proposed. Micro-strip branch lines are introduced to replace multiple resistors used in multi-stage Wilkinson power dividers to increase the bandwidth of single-stag... A miniaturized broadband Wilkinson power divider is proposed. Micro-strip branch lines are introduced to replace multiple resistors used in multi-stage Wilkinson power dividers to increase the bandwidth of single-stage Wilkinson power dividers. To demonstrate its performance, an improved single-stage Wilkinson power divider with four micro-strip branch lines was designed. Simulated results show that the insert loss is better than 3.2 dB, the input return loss, output return loss, and isolation are better than 15 dB respectively, across a 76% bandwidth from 18 to 40 GHz. . 展开更多
关键词 BROADBAND Micro-Strip Branch lines power Divider
下载PDF
Analysis of the Design and Application of a Novel CT Secondary Cable Line Calibrator
3
作者 Jiaxing Ren 《Journal of Electronic Research and Application》 2024年第2期7-11,共5页
With the rapid development of electrical power systems,ensuring the accuracy and reliability of power transmis-sion has become particularly crucial.The secondary cable line calibrator for current transformers(CT)plays... With the rapid development of electrical power systems,ensuring the accuracy and reliability of power transmis-sion has become particularly crucial.The secondary cable line calibrator for current transformers(CT)plays an essential role in calibrating electrical power systems.It is not only related to the safe operation of the system but also directly im-pacts the accuracy of energy metering.This study aims to design and analyze an efficient CT secondary cable line calibra-tor to explore its application effects in the power system.By thoroughly analyzing the characteristics of CT secondary ca-ble lines and the design requirements of the calibrator,this paper proposes an innovative design scheme for the calibrator.This device demonstrates significant effects in enhancing the accuracy and stability of power system calibration,providing robust technical support for the optimization and upgrade of the power system.This research not only offers a theoretical basis and practical guidance for the design and application of CT secondary cable line calibrators but also contributes new ideas and methods for the precise calibration and efficient management of the power system. 展开更多
关键词 CT secondary cable line CALIBRATOR power system DESIGN Application
下载PDF
Performance Evaluation for Medium Voltage MIMO-OFDM Power Line Communication System 被引量:10
4
作者 Yingxue Li Min Zhang +3 位作者 Wenguang Zhu Mengyuan Cheng Cheng Zhou Yongpeng Wu 《China Communications》 SCIE CSCD 2020年第1期151-162,共12页
Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)s... Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)scenario due to the fast development of in-home PLC.The aim of this paper is to evaluate the link-level performance of a medium voltage(MV)MIMO-OFDM communication system based on transmission link under underground power line channel.The MIMO channel is modeled as a modified multipath model in the presence of impulsive noise and background noise.We first perform a measurement on the practical MV MIMO channel parameters for a section of buried cable of 1 km long in Ganzhou city,Jiangxi province,China.Based on the measured channel,we design the frame structure based on an IEEE standard for broadband over power line networks[1]to support MV MIMO-OFDM transmission.According to designed frame structure,we design an encoder and a decoder for a dual binary tail-biting turbo code and optimize some key decoder parameters for low bit error rate performance.Finally,the link-level performance for both spatial multiplexing and spatial diversity are evaluated.Numeral results show that MV MIMO-OFDM is a promising approach to provide both high data rate and link reliability for PLC. 展开更多
关键词 power line communication(PLC) MIMO-OFDM multi-conductor medium voltage underground cables turbo code
下载PDF
Dynamic Balance Control Based on an Adaptive Gain-scheduled Backstepping Scheme for Power-line Inspection Robots 被引量:6
5
作者 Songyi Dian Lin Chen +2 位作者 Son Hoang Ming Pu Junyong Liu 《IEEE/CAA Journal of Automatica Sinica》 EI CSCD 2019年第1期198-208,共11页
This paper presents an adaptive gain-scheduled backstepping control(AGSBC) scheme for the balance control of an underactuated mechanical power-line inspection(PLI) robotic system with two degrees of freedom and a sing... This paper presents an adaptive gain-scheduled backstepping control(AGSBC) scheme for the balance control of an underactuated mechanical power-line inspection(PLI) robotic system with two degrees of freedom and a single control input.First, a nonlinear dynamic model of the balance adjustment process of the PLI robot is constructed, and then the model is linearized at a nominal equilibrium point to overcome the computational infeasibility of the conventional backstepping technique. Second, to solve generalized stabilization control issue for underactuated systems with multiple equilibrium points,an equilibrium manifold linearized model is developed using a scheduling variable, and then a gain-scheduled backstepping control(GSBC) scheme for expanding the operational area of the controlled system is constructed. Finally, an adaptive mechanism is proposed to counteract the impact of external disturbances. The robust stability of the closed-loop system is ensured by Lyapunov theorem. Simulation results demonstrate the effectiveness and high performance of the proposed scheme compared with other control schemes. 展开更多
关键词 Adaptive BACKSTEPPING BALANCE control gain-scheduled inspection robot power line
下载PDF
The design of monitoring communication system Based on Power line carrier 被引量:4
6
作者 Wei-tao MU,Jian-jun HAO,Ping-xiang JIANG,Guo-wei LI (College of Information and Electrical Engineering,Shandong University of Science and Technology,qingdao266510,China) 《Journal of Measurement Science and Instrumentation》 CAS 2010年第S1期23-26,共4页
The design of the power line carrier communication system was introduced in this paper,DSP was adopted as the hardware platform to complete the core task.DSP sending terminal delivered the collecting data to the DSP r... The design of the power line carrier communication system was introduced in this paper,DSP was adopted as the hardware platform to complete the core task.DSP sending terminal delivered the collecting data to the DSP receiving terminal through the power line carrier, and the DSP receiving terminal send the data to PC through a serial port.The design improved the power line carrier communication system and the data transmission became faster and more reliable.The experiment results showed that the PER of the receiving data is less than 0.4%, which satisfied the power line carrier communication requirement Our design is feasible and effective. 展开更多
关键词 DSP power line CARRIER D/A A/D
下载PDF
High Precision Ultrasonic Guided Wave Technique for Inspection of Power Transmission Line 被引量:3
7
作者 CHENG Jun QIU Jinhao +3 位作者 JI Hongli WANG Enrong TAKAGI Toshiyuki UCHIMOTO Tetsuya 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2017年第1期170-179,共10页
Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave pr... Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave propagation in this structure is very complicated, leading to the unfavorable defect localization accuracy. Aiming at this situation, a high precision UGW technique for inspection of local surface defect in power transmission line is proposed. The technique is realized by adopting a novel segmental piezoelectric ring transducer and transducer mounting scheme, combining with the comprehensive characterization of wave propagation and circumferential defect positioning with multiple piezoelectric elements. Firstly, the propagation path of guided waves in the multi-wires of transmission line under the proposed technique condition is investigated experimentally. Next, the wave velocities are calculated by dispersion curves and experiment test respectively, and from comparing of the two results, the guided wave mode propagated in transmission line is confirmed to be F(1,1) mode. Finally, the axial and circumferential positioning of local defective wires in transmission line are both achieved, by using multiple piezoelectric elements to surround the stands and send elastic waves into every single wire. The proposed research can play a role of guiding the development of highly effective UGW method and detecting system for multi-wire transmission line. 展开更多
关键词 ultrasonic guided wave inspection power transmission line piezoelectric transducer defect positioning wavelet transform
下载PDF
The changing process and trend of ground temperature around tower foundations of Qinghai-Tibet Power Transmission line 被引量:2
8
作者 YanLi Xie QiHao Yu +2 位作者 YanHui You ZhongQiu Zhang TingTao Gou 《Research in Cold and Arid Regions》 CSCD 2019年第1期13-20,共8页
After the construction of Qinghai-Tibet Highway and Railway, the Qinghai-Tibet Power Transmission(QTPT) line is another major permafrost engineering project with new types of engineering structures. The changing proce... After the construction of Qinghai-Tibet Highway and Railway, the Qinghai-Tibet Power Transmission(QTPT) line is another major permafrost engineering project with new types of engineering structures. The changing process and trend of ground temperature around tower foundations are crucial for the stability of QTPT. We analyzed the change characteristics and tendencies of the ground temperature based on field monitoring data from 2010 to 2014. The results reveal that soil around the tower foundations froze and connected with the artificial permafrost induced during the construction of footings after the first freezing period, and the soil below the original permafrost table kept freezing in subsequent thawing periods. The ground temperature lowered to that of natural fields, fast or slowly for tower foundations with thermosyphons,while for tower foundations without thermosyphons, the increase in ground temperature resulted in higher temperature than that of natural fields. Also, the permafrost temperature and ice content are significant factors that influence the ground temperature around tower foundations. Specifically, the ground temperature around tower foundations in warm and ice-rich permafrost regions decreased slowly, while that in cold and ice poor permafrost regions cooled faster. Moreover, foundations types impacted the ground temperature, which consisted of different technical processes during construction and variant of tower footing structures. The revealed changing process and trend of the ground temperature is beneficial for evaluating the thermal regime evolution around tower foundations in the context of climate change. 展开更多
关键词 Qinghai-Tibet power Transmission line TOWER FOUNDATION ground temperature change CHARACTERISTIC TREND
下载PDF
Reduction of electric field strength by two species of trees under power transmission lines 被引量:2
9
作者 Hongwei Zhou Liping Sun +4 位作者 Yang Yang Che Liu Tianshi Liu Penghao Xie Ling Ma 《Journal of Forestry Research》 SCIE CAS CSCD 2018年第5期1415-1422,共8页
Electrical pollution is a worldwide concern,because it is potentially harmful to human health.Trees not only play a significant role in moderating the climate,but also can be used as shields against electrical polluti... Electrical pollution is a worldwide concern,because it is potentially harmful to human health.Trees not only play a significant role in moderating the climate,but also can be used as shields against electrical pollution.Shielding effects on the electric field strength under transmission lines by two tree species,Populus alba and Larix gmelinii,were examined in this study.The electrical resistivity at different heights of trees was measured using a PiCUS sonic tomograph,which can image the electrical impedance for trees.The electric field strength around the trees was measured with an elf field strength measurement system,HI-3604,and combined with tree resistivity to develop a model for calculating the electric field intensity around trees using the finite element method.In addition,the feasibility of the finite element method was confirmed by comparing the calculated results and experimental data.The results showed that the trees did reduce the electric field strength.The electric field intensity was reduced by 95.6%,and P.alba was better than L.gmelinii at shielding. 展开更多
关键词 Trees power transmission lines Electric environment Tree electrical resistivity SHIELDING Finite element method
下载PDF
Power Line Monitoring Data Transmission Using Wireless Sensor Network 被引量:4
10
作者 Lifen Li Huaiyu Zhao 《Journal of Power and Energy Engineering》 2015年第8期83-88,共6页
The WSN used in power line monitoring is long chain structure, and the bottleneck near the Sink node is more obvious. In view of this, A Sink nodes’ cooperation mechanism is presented. The Sink nodes from different W... The WSN used in power line monitoring is long chain structure, and the bottleneck near the Sink node is more obvious. In view of this, A Sink nodes’ cooperation mechanism is presented. The Sink nodes from different WSNs are adjacently deployed. Adopting multimode and spatial multiplexing network technology, the network is constructed into multi-mode-level to achieve different levels of data streaming. The network loads are shunted and the network resources are rationally utilized. Through the multi-sink nodes cooperation, the bottlenecks at the Sink node and its near several jump nodes are solved and process the competition of communication between nodes by channel adjustment. Finally, the paper analyzed the method and provided simulation experiment results. Simulation results show that the method can solve the funnel effect of the sink node, and get a good QoS. 展开更多
关键词 WIRELESS Sensor NETWORK (WSN) power line Monitoring Data TRANSMISSION MULTIMODE NETWORK
下载PDF
Steady-state voltage-control method considering large-scale wind-power transmission using half-wavelength transmission lines 被引量:3
11
作者 Hao Tian Hongzheng Liu +3 位作者 Huan Ma Pengfei Zhang Xiaohui Qin Changhui Ma 《Global Energy Interconnection》 EI CAS CSCD 2021年第3期239-250,共12页
Half-wavelength transmission can transmit large-scale renewable energy over very long distances.This paper proposes an improved steady-state voltage-control method for half-wavelength transmission systems considering ... Half-wavelength transmission can transmit large-scale renewable energy over very long distances.This paper proposes an improved steady-state voltage-control method for half-wavelength transmission systems considering largescale wind-power transmission.First,the unique voltage characteristics of half-wavelength lines are deduced based on the distributed parameter model.In the secondary voltage-control level,reactive power-transmission limits of half-wavelength lines are introduced as another control objective except for tracing the pilot bus voltage reference.Considering the uncertainty and fluctuation of wind power,the overvoltage risk-assessment method of half-wavelength lines is presented to determine specific voltage-control strategies.Simulation results demonstrate that the proposed voltage-control method delivers superior tracking performance according to a voltage reference value and prevents the overvoltage risk of halfwavelength lines effectively in different wind-power penetrations. 展开更多
关键词 Half-wavelength lines Secondary voltage control Wind-power transmission Reactive power regulation
下载PDF
A FAST BIT-LOADING ALGORITHM FOR HIGH SPEED POWER LINE COMMUNICATIONS 被引量:2
12
作者 Zhang Shengqing Zhao Li Zou Cairong 《Journal of Electronics(China)》 2012年第5期461-468,共8页
Adaptive bit-loading is a key technology in high speed power line communications with the Orthogonal Frequency Division Multiplexing (OFDM) modulation technology. According to the real situation of the transmitting po... Adaptive bit-loading is a key technology in high speed power line communications with the Orthogonal Frequency Division Multiplexing (OFDM) modulation technology. According to the real situation of the transmitting power spectrum limited in high speed power line communications, this paper explored the adaptive bit loading algorithm to maximize transmission bit number when transmitting power spectral density and bit error rate are not exceed upper limit. With the characteristics of the power line channel, first of all, it obtains the optimal bit loading algorithm, and then provides the improved algorithm to reduce the computational complexity. Based on the analysis and simulation, it offers a non-iterative bit allocation algorithm, and finally the simulation shows that this new algorithm can greatly reduce the computational complexity, and the actual bit allocation results close to optimal. 展开更多
关键词 power line communications Orthogonal Frequency Division Multiplexing (OFDM) Bit-loading
下载PDF
Propagation characteristics of power line harmonic radiation in the ionosphere 被引量:1
13
作者 吴静 付静静 张翀 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第3期238-243,共6页
Theoretical model and solutions on power line harmonic radiation (PLHR) propagating in the ground, air, and anisotropic homogeneous ionosphere are presented, The theoretical model is verified by the PLHR events obse... Theoretical model and solutions on power line harmonic radiation (PLHR) propagating in the ground, air, and anisotropic homogeneous ionosphere are presented, The theoretical model is verified by the PLHR events observed by the DEMETER satellite. Some propagation characteristics of PLHR based on the model are obtained. This paper is bene- ficial to quantitatively interpret the formation mechanism of PLHR phenomenon. 展开更多
关键词 power line harmonic radiation anisotropic medium IONOSPHERE electromagnetic waves
下载PDF
Modeling of OFDM Based Transceiver for Broadband Powerline Communication 被引量:1
14
作者 Syed Samser Ali Amitabha Bhattacharya Dipak Ranjan Poddar 《Journal of Electromagnetic Analysis and Applications》 2014年第6期125-129,共5页
In the recent past power line communication has emerged as an attractive choice for high speed data transfer and is looked upon as inexpensive and reliable media suitable for broadband internet access, home and office... In the recent past power line communication has emerged as an attractive choice for high speed data transfer and is looked upon as inexpensive and reliable media suitable for broadband internet access, home and office automation, in-vehicle data communication etc. In this paper we present an architecture for the physical layer of a PLC transceiver based on Orthogonal Frequency Division Multiplexing (OFDM) and the impact on multipath distortion for PLC transmission in terms of bit error rate. Since there is no standard PLC channel model available, a widely accepted multipath channel model is used for simulation purpose. Simulation results as well as FPGA synthesis verify the effectiveness of the proposed architecture for PLC modem design at 110 Mbps data rate. 展开更多
关键词 OFDM power line Communication (PLC) MULTIPATH CHANNEL FPGA
下载PDF
A line laser detection screen design and projectile echo power calculation in detection screen area 被引量:1
15
作者 Han-shan Li Xiao-qian Zhang +1 位作者 Xue-wei Zhang Quan-min Guo 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2022年第8期1405-1415,共11页
A line laser with high power as the background light source for the design of a new photoelectric detection target is proposed in this paper, aiming to improve the detection ability of the traditional photoelectric de... A line laser with high power as the background light source for the design of a new photoelectric detection target is proposed in this paper, aiming to improve the detection ability of the traditional photoelectric detection target under low background illumination. The laser emitted pulse waveform function and the laser echo pulse response function were used to establish the mathematical model of the reflected echo power of projectile in the detection area and derive the calculation function of minimum detectable echo power in the line laser detection screen, according to information of the line laser emitted power, incident angle of projectile, duration time and detection distance of projectile passing through the line laser detection screen. Calculations and experimental results showed that the design method of line laser detection screen and calculation model of laser echo power are reasonable, and the detection ability of line laser detection screen is obviously higher than that of traditional photoelectric detection screen, especially in low background illumination;at the same time, the designed line laser detection screen was used to combine a six line laser detection screen intersection test system, based on live ammunition for shooting. The test system is stable and able to obtain the dynamic parameters of the flying projectile, verifying that the design of the line laser detection screen in new photoelectric detection target can be suitable for shooting range test applications. 展开更多
关键词 line laser detection screen Photoelectric detection target Photoelectric detection receiver Echo power PROJECTILE
下载PDF
Next Generation Narrowband(Under 500 kHz) Power Line Communications(PLC) Standards 被引量:5
16
作者 Stefano Galli Thierry Lys 《China Communications》 SCIE CSCD 2015年第3期1-8,共8页
In the past decade,several efforts around the world were started with the goal of introducing "smart metering" capabilities into the power grid.These efforts have spurred renewed interest in the design of ne... In the past decade,several efforts around the world were started with the goal of introducing "smart metering" capabilities into the power grid.These efforts have spurred renewed interest in the design of next generation Narrowband Power Line Communications(NB-PLC) transceivers.In the past few years,ITU-T and IEEE have standardized a family of next generation OFDM-based NB-PLC transceivers some of which are today being considered for massive deployments in Europe and Asia.This paper addresses the important role that PLC has not only for smart metering but also for many other Smart Grid applications,and also gives an overview of the main differences between these next generation NB-PLC standards. 展开更多
关键词 IEEE标准 电力线通信 PLC 窄带 智能电表 ITU-T 功能整合 OFDM
下载PDF
SELECTION OF TRANSMISSION LINE MODELS USED IN POWER SYSTEM TRANSIENT SIMULATIONS
17
作者 张小平 陈珩 《Journal of Southeast University(English Edition)》 EI CAS 1992年第2期44-53,共10页
A method used for determining the number of equivalent π sections oftransmission line model according to the frequency range of interest and the model accura-cy defined herein is proposed.Factors influencing the disc... A method used for determining the number of equivalent π sections oftransmission line model according to the frequency range of interest and the model accura-cy defined herein is proposed.Factors influencing the discrepancies between continuous ordistributed parameter and multiple π or lumped parameter models are discussed.Generalconclusions concerning the π section lengths of line models used in transient stability,faulttransient and switching over-voltage studies are drawn.Time-domain simulation resultsconfirm the effectiveness of this method. 展开更多
关键词 power system TRANSIENT TRANSMISSION line MODELLING FREQUENCY characteristics
下载PDF
Modeling Transfer Function of Electrical Power Lines for Broadband Power Line Communication
18
作者 Saad D. Bennani 《International Journal of Communications, Network and System Sciences》 2012年第1期37-42,共6页
The indoor access network is characterized by several branches that cause many reflections. In this paper, we present an approach to model the transfer function of electrical power lines for broadband power line commu... The indoor access network is characterized by several branches that cause many reflections. In this paper, we present an approach to model the transfer function of electrical power lines for broadband power line communication. The assuming channel consists of three wires, which is widely used in many countries. As an application of the proposed method, the effect of line length from transmitter to receiver, branched line length and number of branched are also studied. From the frequency response of the transfer function (magnitude and phase), it is seen that the position of notches and peaks in the magnitude responses are largely affected in terms of attenuation by the electrical network which consists of 15 branches. 展开更多
关键词 power line COMMUNICATIONS TRANSMISSION line THEORY MAGNITUDE Response and BRANCHED line
下载PDF
A new type of Wilkinson dual-frequency power divider with symmetrical transmission line stubs
19
作者 丁尧舜 DONG Gang YANG Yin-tang 《Journal of Chongqing University》 CAS 2014年第1期17-25,共9页
To realize equal power splitting at two arbitrary gigahertz-frequencies, this paper presents a new type of Wilkinson dual frequency power divider, consisting of three-section transmission lines and a series RLC(resist... To realize equal power splitting at two arbitrary gigahertz-frequencies, this paper presents a new type of Wilkinson dual frequency power divider, consisting of three-section transmission lines and a series RLC(resistor, inductor and capacitor)circuit. By equating the [ABCD] matrix of the proposed circuit to that of the quarter-wave impedance transformer, coupled with even/odd mode analyses, the design equations of the proposed network are derived. For verification, two dual-frequency power dividers with dual-band operating frequencies at 0.6 GHz and 3.0 GHz, and 3.8 GHz and 10 GHz respectively are designed and simulated. Simulation results show that the dual-band ratio of the proposed power divider can be as large as 5. Comparisons of the simulation results at X-band and S-band with different power dividers indicate that the proposed dual-band power divider performs better under the scenario of the upper operating frequency extending to X-band. 展开更多
关键词 DUAL-FREQUENCY symmetrical transmission line stubs power divider ARBITRARY
下载PDF
Phase-Locked Loop Based Cancellation of ECG Power Line Interference
20
作者 LI Taihao ZHOU Jianshe +2 位作者 LIU Shupeng SHI Jinsheng REN Fuji 《ZTE Communications》 2018年第1期47-51,共5页
Power line(PL)interference is one significant artifact in electrocardiography(ECG)that needs to be reduced to ensure accurate recording of cardiac signals.Because PL interference is non-stationary and has varying freq... Power line(PL)interference is one significant artifact in electrocardiography(ECG)that needs to be reduced to ensure accurate recording of cardiac signals.Because PL interference is non-stationary and has varying frequency,phase,and amplitude in ECG measurement,adaptive techniques are often necessary to track and cancel the interference.In this paper we present a phase-locked loop(PLL)-based adaptive filter to cancel PL interference.The PLL obtains the reference signal that is fed into the adaptive filter to remove the PL interference at the central frequency of 50 Hz.It is found that the technique can effectively cancel PL interference in real ECG signals and,when compared with some existing techniques such as least mean squares(LMS)adaptive filter,the new technique produces better results in terms of signal-to-interference ratio(SIR). 展开更多
关键词 phase-locked LOOP ECG adaptive FILTER power line cancella-tion
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部