The effects of a magnetic dipole on a nonlinear thermally radiative ferromagnetic liquidflowing over a stretched surface in the presence of Brownian motion and thermophoresis are investigated.By means of a similarity t...The effects of a magnetic dipole on a nonlinear thermally radiative ferromagnetic liquidflowing over a stretched surface in the presence of Brownian motion and thermophoresis are investigated.By means of a similarity transformation,ordinary differential equations are derived and solved afterwards using a numerical(the BVP4C)method.The impact of various parameters,namely the velocity,temperature,concentration,is presented graphically.It is shown that the nanoparticles properties,in conjunction with the magnetic dipole effect,can increase the thermal conductivity of the engineered nanofluid and,consequently,the heat transfer.Comparison with earlier studies indicates high accuracy and effectiveness of the numerical approach.An increase in the Brow-nian motion parameter and thermophoresis parameter enhances the concentration and the related boundary layer.The skin-friction rises when the viscosity parameter is increased.A larger value of the ferromagnetic para-meter results in a higher skin-friction and,vice versa,in a smaller Nusselt number.展开更多
The thermal behavior of an electrically non-conducting magnetic liquid flowing over a stretching cylinder under the influence of a magnetic dipole is considered.The governing nonlinear differential equations are solve...The thermal behavior of an electrically non-conducting magnetic liquid flowing over a stretching cylinder under the influence of a magnetic dipole is considered.The governing nonlinear differential equations are solved numerically using a finite element approach,which is properly validated through comparison with earlier results available in the literature.The results for the velocity and temperature fields are provided for different values of the Reynolds number,ferromagnetic response number,Prandtl number,and viscous dissipation parameter.The influence of some physical parameters on skin friction and heat transfer on the walls of the cylinder is also investigated.The applicability of this research to heat control in electronic devices is discussed to a certain extent.展开更多
Low-field nuclear magnetic resonance magnet(2 MHz) is required for rock core analysis. However, due to its low field strength, it is hard to achieve a high uniform B0 field only by using the passive shimming. Theref...Low-field nuclear magnetic resonance magnet(2 MHz) is required for rock core analysis. However, due to its low field strength, it is hard to achieve a high uniform B0 field only by using the passive shimming. Therefore, active shimming is necessarily used to further improve uniformity for Halbach magnet. In this work, an equivalent magnetic dipole method is presented for designing shim coils. The minimization of the coil power dissipation is considered as an optimal object to minimize coil heating effect, and the deviation from the target field is selected as a penalty function term. The lsqnonlin optimization toolbox of MATLAB is used to solve the optimization problem. Eight shim coils are obtained in accordance with the contour of the stream function. We simulate each shim coil by ANSYS Maxwell software to verify the validity of the designed coils. Measurement results of the field distribution of these coils are consistent with those of the target fields.The uniformity of the B0 field is improved from 114.2 ppm to 26.9 ppm after using these shim coils.展开更多
MEMS swallowable capsule is a novel technology in the non-invasive surgery. This technology provides a way to diagnose directly into the deep intestinal where the traditional invasive technology implemented, such as X...MEMS swallowable capsule is a novel technology in the non-invasive surgery. This technology provides a way to diagnose directly into the deep intestinal where the traditional invasive technology implemented, such as X-Ray, endoscopy. It is a key for us to locate and track the position of a MEMS capsule in clinical applications. To solve this problem, we implemented a magnetic sensor module based on the scalar form of the magnetic dipole model,which was designed with very small size (5.2 * 2. 1 * 1.2 em) and easy to assemble to satisfy the system requirement. Here we discuss in detail the principle of magnetic dipole model, rules of selecting sensor and functions of the module. Some trials are established to test the characteristic of the module. The results of the Cm experiment demonstrates that the module follows the rules of the new magnetic dipole model form.展开更多
Theoretical calculations of the energy levels and magnetic dipole transition parameters for the 1s^(2)2s^(2)2p^(3) and 1s^(2)2p^(5) configurations of nitrogen isoelectronic sequence with Z=21-30 are performed using mu...Theoretical calculations of the energy levels and magnetic dipole transition parameters for the 1s^(2)2s^(2)2p^(3) and 1s^(2)2p^(5) configurations of nitrogen isoelectronic sequence with Z=21-30 are performed using multi-congfiguration Dirac-Fock(MCDF)method.Based on the relativistic computational code GRASP2k compiled within the framework of MCDF method,the electron correlations,Breit interaction and QED effects are well treated in detail.The energy levels,line strengths and transition rates of magnetic dipole transition are obtained and compared with the experimental data avail-able.For most cases,good agreements are achieved and the relative differences of them are less than 0.114%,8.43% and 9.80%,respectively.The scaling laws of the fine structure splitting and transition rate are obtained on the isoelec-tronic sequence and the corresponding physical mechanisms are discussed.The data sets for tables are openly available at https://www.doi.org/10.57760/sciencedb.j00113.00022.展开更多
The interaction between a permanent magnet(PM)assumed as a magnetic dipole and a flat high-temperature superconductor(HTS)is calculated by the advanced frozen-image model.When the dipole vertically moves above the sem...The interaction between a permanent magnet(PM)assumed as a magnetic dipole and a flat high-temperature superconductor(HTS)is calculated by the advanced frozen-image model.When the dipole vertically moves above the semiinfinite HTS,the general analytical expression of vertical force and that of torque are obtained for an arbitrary angle between the magnetization direction of the PM and the c axis of the HTS.The variations of the force and torque are analyzed for angle and vertical movements in both zero-field cooling(ZFC)condition and field cooling(FC)condition.It is found that the maximum vertical repulsive or attractive force has the positive or negative cosine relation with the angle.However,the maximum torque has the positive or negative sine relation.From the viewpoint of the rotational equilibrium,the orientation of the magnetic dipole with zero angle is deemed to be an unstable equilibrium point in ZFC,but the same orientation is considered as a stable equilibrium point in FC.In addition,both of the variation cycles of the maximum force and torque with the angle areπ.展开更多
A manifestly gauge-invariant formulation of non-relativistic quantum mechanics is applied to the case of time-dependent harmonic oscillator in the magnetic dipole approximation. A general equation for obtaining gauge-...A manifestly gauge-invariant formulation of non-relativistic quantum mechanics is applied to the case of time-dependent harmonic oscillator in the magnetic dipole approximation. A general equation for obtaining gauge-invariant transition probability amplitudes is derived.展开更多
The conventional magnetic resonance imaging(MRI)equipment cannot measure large volume samples nondestructively in the engineering site for its heavy weight and closed structure.In order to realize the mobile MRI,this ...The conventional magnetic resonance imaging(MRI)equipment cannot measure large volume samples nondestructively in the engineering site for its heavy weight and closed structure.In order to realize the mobile MRI,this study focuses on the design of gradient coil of unilateral magnet.The unilateral MRI system is used to image the local area above the magnet.The current density distribution of the gradient coil cannot be used as a series of superconducting nuclear magnetic resonance gradient coils,because the region of interest(ROI)and the wiring area of the unilateral magnet are both cylindrical side arc surfaces.Therefore,the equivalent magnetic dipole method is used to design the gradient coil,and the algorithm is improved for the special case of the wiring area and the ROI,so the X and Y gradient coils are designed.Finally,a flexible printed circuit board(PCB)is used to fabricate the gradient coil,and the magnetic field distribution of the ROI is measured by a Gauss meter,and the measured results match with the simulation results.The gradient linearities of x and y coils are 2.82%and 3.56%,respectively,less than 5%of the commercial gradient coil requirement.展开更多
By simplifying saturatedly magnetized wire-rope to magnetic dipoles of the same magnetic field strength, an equivalent magnetic dipoles model is developed and the measuring principle for recognising damage of broken w...By simplifying saturatedly magnetized wire-rope to magnetic dipoles of the same magnetic field strength, an equivalent magnetic dipoles model is developed and the measuring principle for recognising damage of broken wire was presented. The relevant calculation formulas were also deduced. A composite solution method about nonlinear optimization was given. An example was given to illustrate the use of the equivalent magnetic dipoles method for quantitative damage recognition, and demonstrates that the result of this method is consistent with the real situation, so the method is valid and practical. wire-rope, damage of broken wires, quantitative recognition, equivalent magnetic dipoles, simulate展开更多
The superconducting dipole prototype magnet of the collector ring for the Facility for Antiproton and Ion Research (FAIR) is an international cooperation project. The collaborative simulation and testing of the deve...The superconducting dipole prototype magnet of the collector ring for the Facility for Antiproton and Ion Research (FAIR) is an international cooperation project. The collaborative simulation and testing of the developed prototype magnet is presented in this paper. To evaluate the mechanical strength of the coil case during quench, a 3-dimensional (3D) electromagnetic (EM) model was developed based on the solid97 magnetic vector element in the ANSYS commercial software, which includes the air region, coil and yoke. EM analysis was carried out with a peak operating current at 278 A. Then, the solid97 element was transferred into the solid185 element, the coupled analysis was switched from electromagnetic to structural, and the finite element model for the coil case and glass-fiber reinforced composite (G10) spacers was established by the ANSYS Parametric Design Language based on the 3D model from the CATIA V5 software. However, to simulate the friction characteristics inside the coil case, the conta173 surface-to-surface contact element was established. The results for the coil case and G10 spacers show that they are safe and have sufficient strength, on the basis of testing in discharge and quench scenarios.展开更多
Kinetic simulation is a powerful tool to study the excitation and propagation of whistler-mode waves in the Earth’s inner magnetosphere.This method typically applies a scaled-down dipole magnetic field to save comput...Kinetic simulation is a powerful tool to study the excitation and propagation of whistler-mode waves in the Earth’s inner magnetosphere.This method typically applies a scaled-down dipole magnetic field to save computational time.However,it remains unknown whether whistler wave propagation in the scaled-down dipole field is consistent with that in the realistic dipole field.In this work,we develop a ray-tracing code with a scalable dipole magnetic field to address this concern.The simulation results show that parallel whistler waves at different frequencies gradually become oblique after leaving the equator and propagate in different raypaths in a dipole magnetic field.During their propagation,the higher frequency waves tend to have larger wave normal angles at the same latitude.Compared with the wave propagation in a realistic dipole field,the wave raypath and wave normal remain the same,whereas the wave amplification or attenuation is smaller because of the shorter propagation time in a scaled-down dipole field.Our study provides significant guidance for kinetic simulations of whistler-mode waves.展开更多
Magnetic dipole forbidden (M1) transition was studied in large helical device (LHD) and F-, Si- and Ti-like M1 transitions are successfully observed for highly ionized Ar, Kr, Mo and Xe ions. The wavelengths measu...Magnetic dipole forbidden (M1) transition was studied in large helical device (LHD) and F-, Si- and Ti-like M1 transitions are successfully observed for highly ionized Ar, Kr, Mo and Xe ions. The wavelengths measured in visible range for the heavy elements, which are carefully determined with extremely small uncertainties of 0.02 - 0.05 A as a standard wavelength of usual electric dipole (El) plasma emissions, are compared with theoretical predictions. The result shows a good agreement with recent Hatree-Fock calculation including semi-empirical adjustment. The M1 intensity for the F-like ions is examined by analyzing the intensity ratio of M1 to El. Density dependence of the ratio is experimentally verified by comparing with collisional- radiative model calculation on level population. The M1/E1 line ratio for the F-like ions is applied to the α (He^2+) particle diagnostics in ITER, in which a steady-state operation of burning plasmas based on D-T fusion reaction is expected with α particle heating. Unfortunately, the present estimation suggests a negative result for the α particle measurement because the ratio is largely enhanced by the collisional excitation with bulk ions due to high ion temperature of ITER of 10 keV as assumed and the resultant effect of the collisional excitation with α particles becomes less. Meanwhile, the M1 transition, in particular, Ti-like WLIII (W^52+) transition (3627 A) emitted in visible range, is very useful for diagnostics of the impurity behavior and the core plasma parameters in ITER.展开更多
Quantitative analyses of actual measurements rather than modeling have shown that “global warming” has been heterogeneous over the surface of the planet and temporally non-linear. Residual regression analyses by Soa...Quantitative analyses of actual measurements rather than modeling have shown that “global warming” has been heterogeneous over the surface of the planet and temporally non-linear. Residual regression analyses by Soares (2010) indicated increments of increased temperature precede increments of CO<sub><span style="font-size:12px;font-family:Verdana;">2 </span></sub><span style="font-size:12px;font-family:Verdana;">increase. The remarkably strong negative correlation (r = -0.99) between the earth’s magnetic dipole moment values and global CO</span><sub><span style="font-size:12px;font-family:Verdana;">2</span></sub><span style="font-size:12px;font-family:Verdana;">-temperature indicators over the last ~30 years is sufficient to be considered causal if contributing energies were within the same order of magnitude. Quantitative convergence between the energies lost by the diminishing averaged geomagnetic field strength and energies gained within the ocean-atmosphere interface satisfy the measured values for increased global temperature and CO</span><sub><span style="font-size:12px;font-family:Verdana;">2</span></sub><span class="apple-converted-space" style="font-size:12px;font-family:Verdana;"> </span><span style="font-size:12px;font-family:Verdana;">release from sea water. The pivotal variable is the optimal temporal unit employed to estimate the total energies available for physical-chemical reactions. The positive drift in averaged amplitude of geomagnetic activity over the last 100 years augmented this process. Contributions from annual CO</span><sub><span style="font-size:12px;font-family:Verdana;">2</span></sub><span class="apple-converted-space" style="font-size:12px;font-family:Verdana;"> </span><span style="font-size:12px;font-family:Verdana;">from volcanism and shifts in averaged geomagnetic activity, lagged years before the measured global temperature-CO</span><sub><span style="font-size:12px;font-family:Verdana;">2</span></sub><span class="apple-converted-space" style="font-size:12px;font-family:Verdana;"> </span><span style="font-size:12px;font-family:Verdana;">values, are moderating variables for smaller amplitude perturbations. These results indicated that the increase in CO</span><sub><span style="font-size:12px;font-family:Verdana;">2</span></sub><span class="apple-converted-space" style="font-size:12px;font-family:Verdana;"> </span><span style="font-size:12px;font-family:Verdana;">and global temperatures are primarily caused by major geophysical factors, particularly the diminishing total geomagnetic field strength and increased geomagnetic activity, but not by human activities. Strategies for adapting to climate change because of these powerful variables may differ from those that assume exclusive anthropomorphic causes.</span>展开更多
Quantitative analyses of actual measurements rather than modeling have shown that “global warming” has been heterogeneous over the surface of the planet and temporally non-linear. Residual regression analyses by Soa...Quantitative analyses of actual measurements rather than modeling have shown that “global warming” has been heterogeneous over the surface of the planet and temporally non-linear. Residual regression analyses by Soares (2010) indicated increments of increased temperature precede increments of CO<sub>2 </sub>increase. The remarkably strong negative correlation (r = -0.99) between the earth’s magnetic dipole moment values and global CO<sub>2</sub>-temperature indicators over the last ~30 years is sufficient to be considered causal if contributing energies were within the same order of magnitude. Quantitative convergence between the energies lost by the diminishing averaged geomagnetic field strength and energies gained within the ocean-atmosphere interface satisfy the measured values for increased global temperature and CO<sub>2</sub> release from sea water. The pivotal variable is the optimal temporal unit employed to estimate the total energies available for physical-chemical reactions. The positive drift in averaged amplitude of geomagnetic activity over the last 100 years augmented this process. Contributions from annual CO<sub>2</sub> from volcanism and shifts in averaged geomagnetic activity, lagged years before the measured global temperature-CO<sub>2</sub> values, are moderating variables for smaller amplitude perturbations. These results indicated that the increase in CO<sub>2</sub> and global temperatures are primarily caused by major geophysical factors, particularly the diminishing total geomagnetic field strength and increased geomagnetic activity, but not by human activities. Strategies for adapting to climate change because of these powerful variables may differ from those that assume exclusive anthropomorphic causes.展开更多
The single-particle Schrödinger fluid model is designed mainly to calculate the moments of inertia of the axially symmetric deformed nuclei by assuming that each nucleon in the nucleus is moving in a single-parti...The single-particle Schrödinger fluid model is designed mainly to calculate the moments of inertia of the axially symmetric deformed nuclei by assuming that each nucleon in the nucleus is moving in a single-particle potential which is deformed with time t, through its parametric dependence on a classical shape variable α(t). Also, the Nilsson model is designed for the calculations of the single-particle energy levels, the magnetic dipole moments, and the electric quadrupole moments of axially symmetric deformed nuclei by assuming that all the nucleons are moving in the field of an anisotropic oscillator potential. On the other hand, the nuclear superfluidity model is designed for the calculations of the nuclear moments of inertia and the electric quadrupole moments of deformed nuclei which have no axes of symmetry by assuming that the nucleons are moving in a quadruple deformed potential. Furthermore, the cranked Nilsson model is designed for the calculations of the total nuclear energy and the quadrupole moments of deformed nuclei which have no axes of symmetry by modifying the Nilsson potential to include second and fourth order oscillations. Accordingly, to investigate whether the six p-shell isotopes <sup>6</sup>Li, <sup>7</sup>Li, <sup>8</sup>Li, <sup>9</sup>Li, <sup>10</sup>Li, and <sup>11</sup>Li have axes of symmetry or not, we applied the four mentioned models to each nucleus by calculating their moments of inertia, their magnetic dipole moments, and their electric quadrupole moments by varying the deformation parameter β and the non-axiality parameter γ in wide ranges of values for this reason. Hence for the assumption that these isotopes are deformed and have axes of symmetry, we applied the single-particle Schrödinger fluid model and the Nilsson model. On the other hand, for the assumption that these isotopes are deformed and have no axes of symmetry, we applied the cranked Nilsson model and the nuclear super fluidity model. As a result of our calculations, we can conclude that the nucleus <sup>6</sup>Li may be assumed to be deformed and has an axis of symmetry.展开更多
On the basis of the ideal gas model, the polarization of charges in the mantle was obtained, a physical and mathematical model was constructed, and estimated calculations of the dipole mode of the Earth’s magnetic fi...On the basis of the ideal gas model, the polarization of charges in the mantle was obtained, a physical and mathematical model was constructed, and estimated calculations of the dipole mode of the Earth’s magnetic field were performed, taking into account the speed of its angular rotation, the parameters of density and temperature, the chemical composition, the ionization potential, the dielectric constant and the percentage of the main chemical compounds of the mantle substance.展开更多
Based on the magnetic interaction energy, using derivative of the magnetic energy density, a model is proposed to compute the magnetic-induced shear modulus of magnetorheological elastomers. Taking into account the in...Based on the magnetic interaction energy, using derivative of the magnetic energy density, a model is proposed to compute the magnetic-induced shear modulus of magnetorheological elastomers. Taking into account the influences of particles in the same chain and the particles in all adjacent chains, the traditional magnetic dipole model of the magnetorheological elastomers is modified. The influence of the ratio of the distance etween adjacent chains to the distance between adjacent particles in a chain on the magnetic induced shear odulus is quantitatively studied. When the ratio is large, the multi-chain model is compatible with the single chain model, but when the ratio is small, the difference of the two models is significant and can not be neglected. Making certain the size of the columns and the distance between adjacent columns, after constructing the computational model of BCT structures, the mechanical property of the magnetorheological elastomers composed of columnar structures is analyzed. Results show that, conventional point dipole model has overrated the magnetic-induced shear modulus of the magnetorheological elastomers. From the point of increasing the magnetic-induced shear modulus, when the particle volume fraction is small, the chain-like structure exhibits better result than the columnar structure, but when the particle volume fraction is large,the columnar structure will be better.展开更多
Magnetic field gradient tensor measurement is an important technique to obtain position information of magnetic objects. When using magnetic field sensors to measure magnetic field gradient as the coefficients of tens...Magnetic field gradient tensor measurement is an important technique to obtain position information of magnetic objects. When using magnetic field sensors to measure magnetic field gradient as the coefficients of tensor, field differentiation is generally approximated by field difference. As a result, magnetic objects positioning by magnetic field gradient tensor measurement always involves an inherent error caused by sensor sizes, leading to a reduction in detectable distance and detectable angle. In this paper, the inherent positioning error caused by magnetic field gradient tensor measurement is calculated and corrected by iterations based on the systematic position error distribution patterns. The results show that, the detectable distance range and the angle range of an ac magnetic object(2.44 Am^2@1 kHz) can be increased from(0.45 m, 0.75 m),(0?, 25?) to(0.30 m, 0.80 m),(0?,80?), respectively.展开更多
Detecting stress concentration, especially critical stress state leading to structure damage or failure, is one of the most important tasks of equipment diagnosis. Metal magnetic memory technique needs further researc...Detecting stress concentration, especially critical stress state leading to structure damage or failure, is one of the most important tasks of equipment diagnosis. Metal magnetic memory technique needs further research to evaluate stress concentration quantitatively due to ambiguous physical mechanism, though it has potential to detect early defects in ferromagnetic materials. Mild Q235 steel defective specimens in demagnetization state were loaded in tension up to visible necking, with magnetic memory signals measurement made at increasing stress levels. Magnetic signals varied greatly under first several loadings and subsequently tended to stability in the elastic region, which showed that the magnetization always approaches the anhysteretic magnetization curve and was explained by the theory of magnetomechanical effect. In the plastic stage, an abnormal wave occurred in the stress concentration zone and its height value was sensitive to plastic deformation levels and dependent on the distance between the probe and defect, in accordance with the simulation results based on the magnetic dipole model. Different magnetic signal characteristics in the elastic-plastic region indicate that the magnetic memory technique can identify macroyielding and early damage, which is of profound significance for ensuring safe operation of equipment in service.展开更多
We develop a permanent-magnet Zeeman slower with adjustable magnets along the longitudinal and radial directions.Produced by four arrays of cylindrical magnets, the longitudinal magnetic field in the slower is tunable...We develop a permanent-magnet Zeeman slower with adjustable magnets along the longitudinal and radial directions.Produced by four arrays of cylindrical magnets, the longitudinal magnetic field in the slower is tunable if relevant parameters vary, for example, laser detuning or intensity. The proposed Zeeman slower can be reconfigured for Sr atoms. Additionally,we demonstrate that the residual magnetic field produced by the permanent magnets in the magneto-optical trap region can be as small as 0.5 Gs.展开更多
文摘The effects of a magnetic dipole on a nonlinear thermally radiative ferromagnetic liquidflowing over a stretched surface in the presence of Brownian motion and thermophoresis are investigated.By means of a similarity transformation,ordinary differential equations are derived and solved afterwards using a numerical(the BVP4C)method.The impact of various parameters,namely the velocity,temperature,concentration,is presented graphically.It is shown that the nanoparticles properties,in conjunction with the magnetic dipole effect,can increase the thermal conductivity of the engineered nanofluid and,consequently,the heat transfer.Comparison with earlier studies indicates high accuracy and effectiveness of the numerical approach.An increase in the Brow-nian motion parameter and thermophoresis parameter enhances the concentration and the related boundary layer.The skin-friction rises when the viscosity parameter is increased.A larger value of the ferromagnetic para-meter results in a higher skin-friction and,vice versa,in a smaller Nusselt number.
文摘The thermal behavior of an electrically non-conducting magnetic liquid flowing over a stretching cylinder under the influence of a magnetic dipole is considered.The governing nonlinear differential equations are solved numerically using a finite element approach,which is properly validated through comparison with earlier results available in the literature.The results for the velocity and temperature fields are provided for different values of the Reynolds number,ferromagnetic response number,Prandtl number,and viscous dissipation parameter.The influence of some physical parameters on skin friction and heat transfer on the walls of the cylinder is also investigated.The applicability of this research to heat control in electronic devices is discussed to a certain extent.
基金Project supported by the State Key Development Program for Basic Research of China(Grant No.2014CB541602)the National Natural Science Foundation of China(Grant Nos.51677008 and 51707028)the Fundamental Research Funds of Central Universities,China(Grant No.106112015CDJXY150003)
文摘Low-field nuclear magnetic resonance magnet(2 MHz) is required for rock core analysis. However, due to its low field strength, it is hard to achieve a high uniform B0 field only by using the passive shimming. Therefore, active shimming is necessarily used to further improve uniformity for Halbach magnet. In this work, an equivalent magnetic dipole method is presented for designing shim coils. The minimization of the coil power dissipation is considered as an optimal object to minimize coil heating effect, and the deviation from the target field is selected as a penalty function term. The lsqnonlin optimization toolbox of MATLAB is used to solve the optimization problem. Eight shim coils are obtained in accordance with the contour of the stream function. We simulate each shim coil by ANSYS Maxwell software to verify the validity of the designed coils. Measurement results of the field distribution of these coils are consistent with those of the target fields.The uniformity of the B0 field is improved from 114.2 ppm to 26.9 ppm after using these shim coils.
文摘MEMS swallowable capsule is a novel technology in the non-invasive surgery. This technology provides a way to diagnose directly into the deep intestinal where the traditional invasive technology implemented, such as X-Ray, endoscopy. It is a key for us to locate and track the position of a MEMS capsule in clinical applications. To solve this problem, we implemented a magnetic sensor module based on the scalar form of the magnetic dipole model,which was designed with very small size (5.2 * 2. 1 * 1.2 em) and easy to assemble to satisfy the system requirement. Here we discuss in detail the principle of magnetic dipole model, rules of selecting sensor and functions of the module. Some trials are established to test the characteristic of the module. The results of the Cm experiment demonstrates that the module follows the rules of the new magnetic dipole model form.
基金Project supported by the National Natural Science Foundation of China(Grant No.12175096)。
文摘Theoretical calculations of the energy levels and magnetic dipole transition parameters for the 1s^(2)2s^(2)2p^(3) and 1s^(2)2p^(5) configurations of nitrogen isoelectronic sequence with Z=21-30 are performed using multi-congfiguration Dirac-Fock(MCDF)method.Based on the relativistic computational code GRASP2k compiled within the framework of MCDF method,the electron correlations,Breit interaction and QED effects are well treated in detail.The energy levels,line strengths and transition rates of magnetic dipole transition are obtained and compared with the experimental data avail-able.For most cases,good agreements are achieved and the relative differences of them are less than 0.114%,8.43% and 9.80%,respectively.The scaling laws of the fine structure splitting and transition rate are obtained on the isoelec-tronic sequence and the corresponding physical mechanisms are discussed.The data sets for tables are openly available at https://www.doi.org/10.57760/sciencedb.j00113.00022.
基金Projects supported by the National Natural Science Foundation of China(Grant No.11572232)the China Three Gorges Corporation Research Project(Grant No.202103407)。
文摘The interaction between a permanent magnet(PM)assumed as a magnetic dipole and a flat high-temperature superconductor(HTS)is calculated by the advanced frozen-image model.When the dipole vertically moves above the semiinfinite HTS,the general analytical expression of vertical force and that of torque are obtained for an arbitrary angle between the magnetization direction of the PM and the c axis of the HTS.The variations of the force and torque are analyzed for angle and vertical movements in both zero-field cooling(ZFC)condition and field cooling(FC)condition.It is found that the maximum vertical repulsive or attractive force has the positive or negative cosine relation with the angle.However,the maximum torque has the positive or negative sine relation.From the viewpoint of the rotational equilibrium,the orientation of the magnetic dipole with zero angle is deemed to be an unstable equilibrium point in ZFC,but the same orientation is considered as a stable equilibrium point in FC.In addition,both of the variation cycles of the maximum force and torque with the angle areπ.
文摘A manifestly gauge-invariant formulation of non-relativistic quantum mechanics is applied to the case of time-dependent harmonic oscillator in the magnetic dipole approximation. A general equation for obtaining gauge-invariant transition probability amplitudes is derived.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.51677008,51377182,51707028,and 11647098)the Fundamental Research Funds of the Central Universities,China(Grant No.106112017CDJQJ158834)the State Key Development Program for Basic Research of China(Grant No.2014CB541602)
文摘The conventional magnetic resonance imaging(MRI)equipment cannot measure large volume samples nondestructively in the engineering site for its heavy weight and closed structure.In order to realize the mobile MRI,this study focuses on the design of gradient coil of unilateral magnet.The unilateral MRI system is used to image the local area above the magnet.The current density distribution of the gradient coil cannot be used as a series of superconducting nuclear magnetic resonance gradient coils,because the region of interest(ROI)and the wiring area of the unilateral magnet are both cylindrical side arc surfaces.Therefore,the equivalent magnetic dipole method is used to design the gradient coil,and the algorithm is improved for the special case of the wiring area and the ROI,so the X and Y gradient coils are designed.Finally,a flexible printed circuit board(PCB)is used to fabricate the gradient coil,and the magnetic field distribution of the ROI is measured by a Gauss meter,and the measured results match with the simulation results.The gradient linearities of x and y coils are 2.82%and 3.56%,respectively,less than 5%of the commercial gradient coil requirement.
基金Supported by the National Natural Science Foundation of China(50475166) and Natural Science Foundation of Shandong Province (Y2002F09) and Qingdao Scientific Bureau(04-3NS-10)
文摘By simplifying saturatedly magnetized wire-rope to magnetic dipoles of the same magnetic field strength, an equivalent magnetic dipoles model is developed and the measuring principle for recognising damage of broken wire was presented. The relevant calculation formulas were also deduced. A composite solution method about nonlinear optimization was given. An example was given to illustrate the use of the equivalent magnetic dipoles method for quantitative damage recognition, and demonstrates that the result of this method is consistent with the real situation, so the method is valid and practical. wire-rope, damage of broken wires, quantitative recognition, equivalent magnetic dipoles, simulate
基金supported by ASIPP under contract MOU-GSI-ACC-2005-01the Special Fund of Talent Development of Anhui Province(No.2009Z056)+1 种基金the Research Fund for the Doctoral Program of Anhui University of Architecture(No.K02425)the Fund of Anhui Educational Committee(No.KJ2010B036)
文摘The superconducting dipole prototype magnet of the collector ring for the Facility for Antiproton and Ion Research (FAIR) is an international cooperation project. The collaborative simulation and testing of the developed prototype magnet is presented in this paper. To evaluate the mechanical strength of the coil case during quench, a 3-dimensional (3D) electromagnetic (EM) model was developed based on the solid97 magnetic vector element in the ANSYS commercial software, which includes the air region, coil and yoke. EM analysis was carried out with a peak operating current at 278 A. Then, the solid97 element was transferred into the solid185 element, the coupled analysis was switched from electromagnetic to structural, and the finite element model for the coil case and glass-fiber reinforced composite (G10) spacers was established by the ANSYS Parametric Design Language based on the 3D model from the CATIA V5 software. However, to simulate the friction characteristics inside the coil case, the conta173 surface-to-surface contact element was established. The results for the coil case and G10 spacers show that they are safe and have sufficient strength, on the basis of testing in discharge and quench scenarios.
基金supported by the National Natural Science Foundation of China (Grant No. 42104155)the China Postdoctoral Science Foundation (Grant No. 2021M693049)+1 种基金the Fundamental Research Funds for the Central Universities (Grant Nos. WK2080000150 and WK3420000013)the USTC (University of Science and Technology of China) Tang Scholar Program
文摘Kinetic simulation is a powerful tool to study the excitation and propagation of whistler-mode waves in the Earth’s inner magnetosphere.This method typically applies a scaled-down dipole magnetic field to save computational time.However,it remains unknown whether whistler wave propagation in the scaled-down dipole field is consistent with that in the realistic dipole field.In this work,we develop a ray-tracing code with a scalable dipole magnetic field to address this concern.The simulation results show that parallel whistler waves at different frequencies gradually become oblique after leaving the equator and propagate in different raypaths in a dipole magnetic field.During their propagation,the higher frequency waves tend to have larger wave normal angles at the same latitude.Compared with the wave propagation in a realistic dipole field,the wave raypath and wave normal remain the same,whereas the wave amplification or attenuation is smaller because of the shorter propagation time in a scaled-down dipole field.Our study provides significant guidance for kinetic simulations of whistler-mode waves.
基金supported partially by both the LHD project (NIFS09ULPP527)the JSPS-CAS Core-University program in the field of Plasma and Nuclear Fusion
文摘Magnetic dipole forbidden (M1) transition was studied in large helical device (LHD) and F-, Si- and Ti-like M1 transitions are successfully observed for highly ionized Ar, Kr, Mo and Xe ions. The wavelengths measured in visible range for the heavy elements, which are carefully determined with extremely small uncertainties of 0.02 - 0.05 A as a standard wavelength of usual electric dipole (El) plasma emissions, are compared with theoretical predictions. The result shows a good agreement with recent Hatree-Fock calculation including semi-empirical adjustment. The M1 intensity for the F-like ions is examined by analyzing the intensity ratio of M1 to El. Density dependence of the ratio is experimentally verified by comparing with collisional- radiative model calculation on level population. The M1/E1 line ratio for the F-like ions is applied to the α (He^2+) particle diagnostics in ITER, in which a steady-state operation of burning plasmas based on D-T fusion reaction is expected with α particle heating. Unfortunately, the present estimation suggests a negative result for the α particle measurement because the ratio is largely enhanced by the collisional excitation with bulk ions due to high ion temperature of ITER of 10 keV as assumed and the resultant effect of the collisional excitation with α particles becomes less. Meanwhile, the M1 transition, in particular, Ti-like WLIII (W^52+) transition (3627 A) emitted in visible range, is very useful for diagnostics of the impurity behavior and the core plasma parameters in ITER.
文摘Quantitative analyses of actual measurements rather than modeling have shown that “global warming” has been heterogeneous over the surface of the planet and temporally non-linear. Residual regression analyses by Soares (2010) indicated increments of increased temperature precede increments of CO<sub><span style="font-size:12px;font-family:Verdana;">2 </span></sub><span style="font-size:12px;font-family:Verdana;">increase. The remarkably strong negative correlation (r = -0.99) between the earth’s magnetic dipole moment values and global CO</span><sub><span style="font-size:12px;font-family:Verdana;">2</span></sub><span style="font-size:12px;font-family:Verdana;">-temperature indicators over the last ~30 years is sufficient to be considered causal if contributing energies were within the same order of magnitude. Quantitative convergence between the energies lost by the diminishing averaged geomagnetic field strength and energies gained within the ocean-atmosphere interface satisfy the measured values for increased global temperature and CO</span><sub><span style="font-size:12px;font-family:Verdana;">2</span></sub><span class="apple-converted-space" style="font-size:12px;font-family:Verdana;"> </span><span style="font-size:12px;font-family:Verdana;">release from sea water. The pivotal variable is the optimal temporal unit employed to estimate the total energies available for physical-chemical reactions. The positive drift in averaged amplitude of geomagnetic activity over the last 100 years augmented this process. Contributions from annual CO</span><sub><span style="font-size:12px;font-family:Verdana;">2</span></sub><span class="apple-converted-space" style="font-size:12px;font-family:Verdana;"> </span><span style="font-size:12px;font-family:Verdana;">from volcanism and shifts in averaged geomagnetic activity, lagged years before the measured global temperature-CO</span><sub><span style="font-size:12px;font-family:Verdana;">2</span></sub><span class="apple-converted-space" style="font-size:12px;font-family:Verdana;"> </span><span style="font-size:12px;font-family:Verdana;">values, are moderating variables for smaller amplitude perturbations. These results indicated that the increase in CO</span><sub><span style="font-size:12px;font-family:Verdana;">2</span></sub><span class="apple-converted-space" style="font-size:12px;font-family:Verdana;"> </span><span style="font-size:12px;font-family:Verdana;">and global temperatures are primarily caused by major geophysical factors, particularly the diminishing total geomagnetic field strength and increased geomagnetic activity, but not by human activities. Strategies for adapting to climate change because of these powerful variables may differ from those that assume exclusive anthropomorphic causes.</span>
文摘Quantitative analyses of actual measurements rather than modeling have shown that “global warming” has been heterogeneous over the surface of the planet and temporally non-linear. Residual regression analyses by Soares (2010) indicated increments of increased temperature precede increments of CO<sub>2 </sub>increase. The remarkably strong negative correlation (r = -0.99) between the earth’s magnetic dipole moment values and global CO<sub>2</sub>-temperature indicators over the last ~30 years is sufficient to be considered causal if contributing energies were within the same order of magnitude. Quantitative convergence between the energies lost by the diminishing averaged geomagnetic field strength and energies gained within the ocean-atmosphere interface satisfy the measured values for increased global temperature and CO<sub>2</sub> release from sea water. The pivotal variable is the optimal temporal unit employed to estimate the total energies available for physical-chemical reactions. The positive drift in averaged amplitude of geomagnetic activity over the last 100 years augmented this process. Contributions from annual CO<sub>2</sub> from volcanism and shifts in averaged geomagnetic activity, lagged years before the measured global temperature-CO<sub>2</sub> values, are moderating variables for smaller amplitude perturbations. These results indicated that the increase in CO<sub>2</sub> and global temperatures are primarily caused by major geophysical factors, particularly the diminishing total geomagnetic field strength and increased geomagnetic activity, but not by human activities. Strategies for adapting to climate change because of these powerful variables may differ from those that assume exclusive anthropomorphic causes.
文摘The single-particle Schrödinger fluid model is designed mainly to calculate the moments of inertia of the axially symmetric deformed nuclei by assuming that each nucleon in the nucleus is moving in a single-particle potential which is deformed with time t, through its parametric dependence on a classical shape variable α(t). Also, the Nilsson model is designed for the calculations of the single-particle energy levels, the magnetic dipole moments, and the electric quadrupole moments of axially symmetric deformed nuclei by assuming that all the nucleons are moving in the field of an anisotropic oscillator potential. On the other hand, the nuclear superfluidity model is designed for the calculations of the nuclear moments of inertia and the electric quadrupole moments of deformed nuclei which have no axes of symmetry by assuming that the nucleons are moving in a quadruple deformed potential. Furthermore, the cranked Nilsson model is designed for the calculations of the total nuclear energy and the quadrupole moments of deformed nuclei which have no axes of symmetry by modifying the Nilsson potential to include second and fourth order oscillations. Accordingly, to investigate whether the six p-shell isotopes <sup>6</sup>Li, <sup>7</sup>Li, <sup>8</sup>Li, <sup>9</sup>Li, <sup>10</sup>Li, and <sup>11</sup>Li have axes of symmetry or not, we applied the four mentioned models to each nucleus by calculating their moments of inertia, their magnetic dipole moments, and their electric quadrupole moments by varying the deformation parameter β and the non-axiality parameter γ in wide ranges of values for this reason. Hence for the assumption that these isotopes are deformed and have axes of symmetry, we applied the single-particle Schrödinger fluid model and the Nilsson model. On the other hand, for the assumption that these isotopes are deformed and have no axes of symmetry, we applied the cranked Nilsson model and the nuclear super fluidity model. As a result of our calculations, we can conclude that the nucleus <sup>6</sup>Li may be assumed to be deformed and has an axis of symmetry.
文摘On the basis of the ideal gas model, the polarization of charges in the mantle was obtained, a physical and mathematical model was constructed, and estimated calculations of the dipole mode of the Earth’s magnetic field were performed, taking into account the speed of its angular rotation, the parameters of density and temperature, the chemical composition, the ionization potential, the dielectric constant and the percentage of the main chemical compounds of the mantle substance.
文摘Based on the magnetic interaction energy, using derivative of the magnetic energy density, a model is proposed to compute the magnetic-induced shear modulus of magnetorheological elastomers. Taking into account the influences of particles in the same chain and the particles in all adjacent chains, the traditional magnetic dipole model of the magnetorheological elastomers is modified. The influence of the ratio of the distance etween adjacent chains to the distance between adjacent particles in a chain on the magnetic induced shear odulus is quantitatively studied. When the ratio is large, the multi-chain model is compatible with the single chain model, but when the ratio is small, the difference of the two models is significant and can not be neglected. Making certain the size of the columns and the distance between adjacent columns, after constructing the computational model of BCT structures, the mechanical property of the magnetorheological elastomers composed of columnar structures is analyzed. Results show that, conventional point dipole model has overrated the magnetic-induced shear modulus of the magnetorheological elastomers. From the point of increasing the magnetic-induced shear modulus, when the particle volume fraction is small, the chain-like structure exhibits better result than the columnar structure, but when the particle volume fraction is large,the columnar structure will be better.
基金supported by the National Natural Science Foundation of China(61473023)
文摘Magnetic field gradient tensor measurement is an important technique to obtain position information of magnetic objects. When using magnetic field sensors to measure magnetic field gradient as the coefficients of tensor, field differentiation is generally approximated by field difference. As a result, magnetic objects positioning by magnetic field gradient tensor measurement always involves an inherent error caused by sensor sizes, leading to a reduction in detectable distance and detectable angle. In this paper, the inherent positioning error caused by magnetic field gradient tensor measurement is calculated and corrected by iterations based on the systematic position error distribution patterns. The results show that, the detectable distance range and the angle range of an ac magnetic object(2.44 Am^2@1 kHz) can be increased from(0.45 m, 0.75 m),(0?, 25?) to(0.30 m, 0.80 m),(0?,80?), respectively.
基金supported by National Natural Science Foundation of China(Grant No. 10772061)Heilongjiang Provincial Natural Science Foundation of China(Grant No. A200907)Specialized Research Fundfor the Doctoral Program of Higher Education of China(Grant No.20092322120001)
文摘Detecting stress concentration, especially critical stress state leading to structure damage or failure, is one of the most important tasks of equipment diagnosis. Metal magnetic memory technique needs further research to evaluate stress concentration quantitatively due to ambiguous physical mechanism, though it has potential to detect early defects in ferromagnetic materials. Mild Q235 steel defective specimens in demagnetization state were loaded in tension up to visible necking, with magnetic memory signals measurement made at increasing stress levels. Magnetic signals varied greatly under first several loadings and subsequently tended to stability in the elastic region, which showed that the magnetization always approaches the anhysteretic magnetization curve and was explained by the theory of magnetomechanical effect. In the plastic stage, an abnormal wave occurred in the stress concentration zone and its height value was sensitive to plastic deformation levels and dependent on the distance between the probe and defect, in accordance with the simulation results based on the magnetic dipole model. Different magnetic signal characteristics in the elastic-plastic region indicate that the magnetic memory technique can identify macroyielding and early damage, which is of profound significance for ensuring safe operation of equipment in service.
基金Project supported by the National Key Basic Research and Development Program of China(Grant Nos.2012CB821302 and 2016YFA0302103)the National Natural Science Foundation of China(Grant No.11134003)+1 种基金the National High Technology Research and Development Program of China(Grant No.2014AA123401)the Shanghai Excellent Academic Leaders Program of China(Grant No.12XD1402400)
文摘We develop a permanent-magnet Zeeman slower with adjustable magnets along the longitudinal and radial directions.Produced by four arrays of cylindrical magnets, the longitudinal magnetic field in the slower is tunable if relevant parameters vary, for example, laser detuning or intensity. The proposed Zeeman slower can be reconfigured for Sr atoms. Additionally,we demonstrate that the residual magnetic field produced by the permanent magnets in the magneto-optical trap region can be as small as 0.5 Gs.