In this paper,a 20kW vehicle built-in permanent magnet synchronous motor is taken as an example,and a magnetic barrier structure is added to the rotor of the motor to solve the uneven saturation problem of the rotor s...In this paper,a 20kW vehicle built-in permanent magnet synchronous motor is taken as an example,and a magnetic barrier structure is added to the rotor of the motor to solve the uneven saturation problem of the rotor side magnetic bridge.This structure improves the air-gap flux density waveform of the motor by influencing the internal magnetic flux path of the motor rotor,thus improving the sine of the no-load back EMF waveform of the motor and reducing the torque ripple of the motor.At the same time,Taguchi method is used to optimize the structural parameters of the added magnetic barrier.In order to facilitate the analysis of its uneven saturation phenomenon and improve the optimization effect,a simple equivalent magnetic network(EMN)model considering the uneven saturation of rotor magnetic bridge is established in this paper,and the initial values of optimization factors are selected based on this model.Finally,the no-load back EMF waveform distortion rate,torque ripple and output torque of the optimized motor are compared and analyzed,and the influence of magnetic barrier structure parameters on the electromagnetic performance of the motor is also analyzed.The results show that the optimized motor can not change the output torque of the motor as much as possible on the basis of reducing the waveform distortion rate of no-load back EMF and torque ripple.展开更多
A magnetic bar carbon paste electrode (MBCPE) modified with Fe3O4 magnetic nanoparticles (Fe3O4NPs) and 2‐(3,4‐dihydroxyphenyl) benzothiazole (DPB) for the electrochemical determina‐tion of hydrazine was de...A magnetic bar carbon paste electrode (MBCPE) modified with Fe3O4 magnetic nanoparticles (Fe3O4NPs) and 2‐(3,4‐dihydroxyphenyl) benzothiazole (DPB) for the electrochemical determina‐tion of hydrazine was developed. The DPB was firstly self‐assembled on the Fe3O4NPs, and the re‐sulting Fe3O4NPs/DPB composite was then absorbed on the designed MBCPE. The MBCPE was used to attract the magnetic nanoparticles to the electrode surface. Owing to its high conductivity and large effective surface area, the novel electrode had a very large current response for the electrocat‐alytic oxidation of hydrazine. The modified electrode was characterized by voltammetry, scanning electron microscopy, electrochemical impedance spectroscopy, infrared spectroscopy, and UV‐visible spectroscopy. Voltammetric methods were used to study the electrochemical behaviour of hydrazine on MBCPE/Fe3O4NPs/DPB in phosphate buffer solution (pH = 7.0). The MBCPE/Fe3O4NPs/DPB, acting as an electrochemical sensor, exhibited very high electrocatalytic activity for the oxidation of hydrazine. The presence of DPB was found to reduce the oxidation potential of hydrazine and increase the catalytic current. The dependence of the electrocatalytic current on the hydrazine concentration exhibited two linear ranges, 0.1–0.4 μmol/L and 0.7–12.0 μmol/L, with a detection limit of 18.0 nmol/L. Additionally, the simultaneous determination of hydrazine and phe‐nol was investigated using the MBCPE/Fe3O4NPs/DPB electrode. Voltammetric experiments showed a linear range of 100–470 μmol/L and a detection limit of 24.3 μmol/L for phenol, and the proposed electrode was applied to the determination of hydrazine and phenol in water samples.展开更多
The spin-dependent conductance and magnetoresistance ratio (MRR) for a semiconductor heterostructures consisting of two magnetic barriers with different height and space have been investigated by the transfer-matrix...The spin-dependent conductance and magnetoresistance ratio (MRR) for a semiconductor heterostructures consisting of two magnetic barriers with different height and space have been investigated by the transfer-matrix method. It is shown that the splitting of the conductance for parallel and antiparallel magnetization configurations results in tremendous spin-dependent MRR, and the maximal MRRs reach 5300% and 3800% for the magnetic barrier spaces W = 81.3 and 243.9 nm, respectively. The obtained spin-filtering transport property of nanostructures with magnetic barriers may be useful to magnetic-barrier-based spintronics.展开更多
The spin-dependent transport properties in the non-collinear pattern of series of δ-magnetic barriers are studied by using scattering theory and Green's function methods. The Green's function is obtained by using d...The spin-dependent transport properties in the non-collinear pattern of series of δ-magnetic barriers are studied by using scattering theory and Green's function methods. The Green's function is obtained by using distorted wave approach and the scattering matrix is related by Fisher-Lee relationship. In addition to reproducing the results of Papp's and Xu's in parallel and antiparallel configurations, we also obtain further results, where arbitrary orientations of the magnetic barriers and arbitrary number of barriers are included. The main finding of our results is that the signs of polarizations can be switched around some "geometric unpolarized windows". The well-known antiparallel configuration has no such characteristics. Furthermore, we discuss spin-related partial densities of states in both polarized and unpolarized structures.展开更多
Because of the helicity of electrons in HgTe quantum wells(QWs) with inverted band structures,the electrons cannot be confined by electric barriers since electrons can tunnel the barriers perfectly without backscatt...Because of the helicity of electrons in HgTe quantum wells(QWs) with inverted band structures,the electrons cannot be confined by electric barriers since electrons can tunnel the barriers perfectly without backscattering in the HgTe QWs.This behavior is similar to Dirac electrons in graphene.In this paper,we propose a scheme to confine carriers in HgTe QWs using an electric-magnetic barrier.We calculate the transmission of carriers in 2-dimensional HgTe QWs and find that the wave-vector filtering effect of local magnetic fields can confine the carriers.The confining effect will have a potential application in nanodevices based on HgTe QWs.展开更多
The Magnetic Barkhausen Noise (MBN) technology is a non-destructive method to measure the neutral temperature of thc CWR track. A series of in-field verifications and data comparison on Australian mainline tracks ha...The Magnetic Barkhausen Noise (MBN) technology is a non-destructive method to measure the neutral temperature of thc CWR track. A series of in-field verifications and data comparison on Australian mainline tracks have shown the results from that system are highly accurate and reliable. The system can be an accuracy and cost-effective tool to prevent the potential buckling and break of CWR rails. The physical backgrounds and features of the system are represented in this paper. The Darwin-Alice Springs Line is a newly constructed main line in Australia which is linked from the north and middle of Australia. Originally, this rail line is designed and constructed in a "cost-effective" way to a lower price, and the key parameters are relatively low. To maintain the stability of the CWR tracks in a very harsh environment, some new technologies such as the MBN technology were utilised. From the results of neutral temperature, it is found that the majority of them are very high. Combined with the calculation and finite element analysis, these problems evidenced that it is caused by the low toe load fastening system and high sleeper spacing. After that some suggestions are given to improve the stability of the CWR on the railway line.展开更多
Magnetic Barkhausen Noise (MBN) is a phenomenon of electromagnetic energy emission due to the movement of magnetic domain walls inside ferromagnetic materials when they are locally magnetized by an alternating magneti...Magnetic Barkhausen Noise (MBN) is a phenomenon of electromagnetic energy emission due to the movement of magnetic domain walls inside ferromagnetic materials when they are locally magnetized by an alternating magnetic field. According to Faraday’s law of electromagnetic induction, the noise can be received by the coil attached to the surface of the material being magnetized and the noise carries the message of the characteristics of the material such as stresses, hardness, phase content, etc. Based on the characteristic of the noise, research about the relationship between the welding stresses in the welding assembly and the noise, the fatigue damage of the plate structure and the noise, and the influence of heat treatment and the variation of phase content to the noise are carried out in this paper.展开更多
Hardened depths on steel samples are evaluated using a non-destructive technique based on the measurement of surface magnetic Barkhausen noise (MBN). Based on the results or experiments, the relation betweeu hardened ...Hardened depths on steel samples are evaluated using a non-destructive technique based on the measurement of surface magnetic Barkhausen noise (MBN). Based on the results or experiments, the relation betweeu hardened depth and MBN is found, and a conclusion that the hardened depth can be measured by the way of measuring the MBN slgnals is obtained.展开更多
Magnetic Barkhausen noise ( MBN) is a phenomenon of electromagnetic energy due to the movement of magnetic domain walls inside ferromagnetic materials when they are locally magnetized by an alternating magnetic fiel...Magnetic Barkhausen noise ( MBN) is a phenomenon of electromagnetic energy due to the movement of magnetic domain walls inside ferromagnetic materials when they are locally magnetized by an alternating magnetic fields. According to Faraday's law of electromagnetic induction, the noise can be received by the coil attached to the surface of the material being magnetized and the noise carries the message of the characteristics of the material such as stresses, hardness, phase content, etc. Based on the characteristic of the noise, researching about the relationship between the residual stress in the welding assembly and the noise are carried out. Furthermore, data process is performed by RMS (Root Mean Square) equation and Power Spectrum analysis.展开更多
The Zeno time has been calculated for a metastable two-level atom tunneling through a interacting thermal magnetic field. The process of weak measurement has been utilized for the estimation of the timescale. Zeno tim...The Zeno time has been calculated for a metastable two-level atom tunneling through a interacting thermal magnetic field. The process of weak measurement has been utilized for the estimation of the timescale. Zeno time has been shown to be temperature dependent. From the calculation it is evident that the Zeno time decreases with the increase of temperature. Moreover, the result restricts the Zeno time to a maximum limiting value, irrespective of how frequent the measurement process is.展开更多
Saturation magnetization,magneto-crystalline anisotropy field,and dielectric properties are closely related to microwave devices applied at different frequencies.For regulating the magnetic and dielectric properties o...Saturation magnetization,magneto-crystalline anisotropy field,and dielectric properties are closely related to microwave devices applied at different frequencies.For regulating the magnetic and dielectric properties of W-type barium ferrites,single-phase BaMe_(2)Fe_(16)O_(27)(Me=Fe,Mn,Zn,Ni,Co) with different Me ions were synthesized by the high-temperature solid-state method.The saturation magnetization(Ms) range from 47.77 emu/g to 95.34 emu/g and the magnetic anisotropy field(H_a) range from 10700.60 Oe(1 Oe=79.5775 A·m^(-1)) to 13739.57 Oe,depending on the type of cation substitution in the hexagonal lattice.The dielectric permittivity and dielectric loss decrease with increasing frequency of the AC electric field in the low-frequency region,while they almost remain constant in the high-frequency region.The charac teristics of easy regulation and preparation make it a potential candidate for use in microwave device applications.展开更多
Although heavy-ion collisions generate strong magnetic fields,their direct measurement is a challenging task.A new observable,the baryon electric charge correlation,was recently found to be sensitive to the magnetic f...Although heavy-ion collisions generate strong magnetic fields,their direct measurement is a challenging task.A new observable,the baryon electric charge correlation,was recently found to be sensitive to the magnetic field strength and thus could be used as a magnetometer for heavy-ion collisions.Additionally,this observable may shed light on the equation of state and phase structure of quantum chromodynamics(QCD)under magnetic fields.Determining and understanding the phase structure of quantum chromodynamics(QCD)is important in contemporary physics[1].展开更多
BACKGROUND Percutaneous endoscopic lumbar decompression(PELD)shows promise for lumbar spinal stenosis(LSS)treatment,but its use is limited by the disease's complexity and procedural challenges.AIM In this study,th...BACKGROUND Percutaneous endoscopic lumbar decompression(PELD)shows promise for lumbar spinal stenosis(LSS)treatment,but its use is limited by the disease's complexity and procedural challenges.AIM In this study,the effects of preoperative planning and intraoperative guidance with computed tomography(CT)/magnetic resonance imaging(MRI)registration techniques on PELD for LSS and postoperative rehabilitation outcomes were evaluated.METHODS This retrospective study was conducted with data from patients who underwent PELD for LSS between January 2021 and December 2023.Patients were assigned to preoperative CT/MRI registration and control groups.Data collected included the operative time,length of hospital stay,visual analog scale(VAS)scores for low back and leg pain,and the Japanese Orthopaedic Association(JOA)lumbar spine score.Differences between groups were assessed using Student’s t test.RESULTS Data from 135 patients(71 in the CT/MRI registration group,64 in the control group)were analyzed.The operative time was significantly shorter in the CT/MRI registration group(P=0.007).At 2 months postoperatively,both groups showed significant reductions in VAS leg and low back pain scores(all P<0.001)and improvements in the JOA score(both P<0.001).No complication or death occurred.Preoperatively,pain and JOA scores were similar between groups(P=0.830,P=0.470,and P=0.287,respectively).At 2 months postoperatively,patients in the CT/MRI registration group reported lower leg and low back pain levels(P<0.001 and P=0.001,respectively)and had higher JOA scores(P=0.004)than did patients in the control group.CONCLUSION Preoperative CT/MRI registration for PELD for LSS reduced the operative time and VAS pain scores at 2 months and improved JOA scores,demonstrating enhanced effectiveness and safety.展开更多
Cerebral small vessel disease is a neurological disease that affects the brain microvasculature and which is commonly observed among the elderly.Although at first it was considered innocuous,small vessel disease is no...Cerebral small vessel disease is a neurological disease that affects the brain microvasculature and which is commonly observed among the elderly.Although at first it was considered innocuous,small vessel disease is nowadays regarded as one of the major vascular causes of dementia.Radiological signs of small vessel disease include small subcortical infarcts,white matter magnetic resonance imaging hyperintensities,lacunes,enlarged perivascular spaces,cerebral microbleeds,and brain atrophy;however,great heterogeneity in clinical symptoms is observed in small vessel disease patients.The pathophysiology of these lesions has been linked to multiple processes,such as hypoperfusion,defective cerebrovascular reactivity,and blood-brain barrier dysfunction.Notably,studies on small vessel disease suggest that blood-brain barrier dysfunction is among the earliest mechanisms in small vessel disease and might contribute to the development of the hallmarks of small vessel disease.Therefore,the purpose of this review is to provide a new foundation in the study of small vessel disease pathology.First,we discuss the main structural domains and functions of the blood-brain barrier.Secondly,we review the most recent evidence on blood-brain barrier dysfunction linked to small vessel disease.Finally,we conclude with a discussion on future perspectives and propose potential treatment targets and interventions.展开更多
Prolife ration of neural stem cells is crucial for promoting neuronal regeneration and repairing cerebral infarction damage.Transcranial magnetic stimulation(TMS)has recently emerged as a tool for inducing endogenous ...Prolife ration of neural stem cells is crucial for promoting neuronal regeneration and repairing cerebral infarction damage.Transcranial magnetic stimulation(TMS)has recently emerged as a tool for inducing endogenous neural stem cell regeneration,but its underlying mechanisms remain unclea r In this study,we found that repetitive TMS effectively promotes the proliferation of oxygen-glucose deprived neural stem cells.Additionally,repetitive TMS reduced the volume of cerebral infa rction in a rat model of ischemic stro ke caused by middle cerebral artery occlusion,im p roved rat cognitive function,and promoted the proliferation of neural stem cells in the ischemic penumbra.RNA-sequencing found that repetitive TMS activated the Wnt signaling pathway in the ischemic penumbra of rats with cerebral ischemia.Furthermore,PCR analysis revealed that repetitive TMS promoted AKT phosphorylation,leading to an increase in mRNA levels of cell cycle-related proteins such as Cdk2 and Cdk4.This effect was also associated with activation of the glycogen synthase kinase 3β/β-catenin signaling pathway,which ultimately promotes the prolife ration of neural stem cells.Subsequently,we validated the effect of repetitive TMS on AKT phosphorylation.We found that repetitive TMS promoted Ca2+influx into neural stem cells by activating the P2 calcium channel/calmodulin pathway,thereby promoting AKT phosphorylation and activating the glycogen synthase kinase 3β/β-catenin pathway.These findings indicate that repetitive TMS can promote the proliferation of endogenous neural stem cells through a Ca2+influx-dependent phosphorylated AKT/glycogen synthase kinase 3β/β-catenin signaling pathway.This study has produced pioneering res ults on the intrinsic mechanism of repetitive TMS to promote neural function recove ry after ischemic stro ke.These results provide a stro ng scientific foundation for the clinical application of repetitive TMS.Moreover,repetitive TMS treatment may not only be an efficient and potential approach to support neurogenesis for further therapeutic applications,but also provide an effective platform for the expansion of neural stem cells.展开更多
Using THz emission spectroscopy,we investigate the elementary spin dynamics in ferromagnetic single-layer Fe on a sub-picosecond timescale.We demonstrate that THz radiation changes its polarity with reversal of the ma...Using THz emission spectroscopy,we investigate the elementary spin dynamics in ferromagnetic single-layer Fe on a sub-picosecond timescale.We demonstrate that THz radiation changes its polarity with reversal of the magnetization applied by the external magnetic field.In addition,it is found that the sign of THz polarity excited from different sides is defined by the thickness of the Fe layer and Fe/dielectric interface.Based on the thickness and symmetry dependences of THz emission,we experimentally distinguish between the two major contributions:ultrafast demagnetization and the anomalous Hall effect.Our experimental results not only enrich understanding of THz electromagnetic generation induced by femtosecond laser pulses but also provide a practical way to access laser-induced ultrafast spin dynamics in magnetic structures.展开更多
BACKGROUND Perineural invasion(PNI)has been used as an important pathological indicator and independent prognostic factor for patients with rectal cancer(RC).Preoperative prediction of PNI status is helpful for indivi...BACKGROUND Perineural invasion(PNI)has been used as an important pathological indicator and independent prognostic factor for patients with rectal cancer(RC).Preoperative prediction of PNI status is helpful for individualized treatment of RC.Recently,several radiomics studies have been used to predict the PNI status in RC,demonstrating a good predictive effect,but the results lacked generalizability.The preoperative prediction of PNI status is still challenging and needs further study.AIM To establish and validate an optimal radiomics model for predicting PNI status preoperatively in RC patients.METHODS This retrospective study enrolled 244 postoperative patients with pathologically confirmed RC from two independent centers.The patients underwent preoperative high-resolution magnetic resonance imaging(MRI)between May 2019 and August 2022.Quantitative radiomics features were extracted and selected from oblique axial T2-weighted imaging(T2WI)and contrast-enhanced T1WI(T1CE)sequences.The radiomics signatures were constructed using logistic regression analysis and the predictive potential of various sequences was compared(T2WI,T1CE and T2WI+T1CE fusion sequences).A clinical-radiomics(CR)model was established by combining the radiomics features and clinical risk factors.The internal and external validation groups were used to validate the proposed models.The area under the receiver operating characteristic curve(AUC),DeLong test,net reclassification improvement(NRI),integrated discrimination improvement(IDI),calibration curve,and decision curve analysis(DCA)were used to evaluate the model performance.RESULTS Among the radiomics models,the T2WI+T1CE fusion sequences model showed the best predictive performance,in the training and internal validation groups,the AUCs of the fusion sequence model were 0.839[95%confidence interval(CI):0.757-0.921]and 0.787(95%CI:0.650-0.923),which were higher than those of the T2WI and T1CE sequence models.The CR model constructed by combining clinical risk factors had the best predictive performance.In the training and internal and external validation groups,the AUCs of the CR model were 0.889(95%CI:0.824-0.954),0.889(95%CI:0.803-0.976)and 0.894(95%CI:0.814-0.974).Delong test,NRI,and IDI showed that the CR model had significant differences from other models(P<0.05).Calibration curves demonstrated good agreement,and DCA revealed significant benefits of the CR model.CONCLUSION The CR model based on preoperative MRI radiomics features and clinical risk factors can preoperatively predict the PNI status of RC noninvasively,which facilitates individualized treatment of RC patients.展开更多
Repetitive transcranial magnetic stimulation has been increasingly studied in different neurological diseases,and although most studies focus on its effects on neuronal cells,the contribution of nonneuronal cells to t...Repetitive transcranial magnetic stimulation has been increasingly studied in different neurological diseases,and although most studies focus on its effects on neuronal cells,the contribution of nonneuronal cells to the improvement trigge red by repetitive transcranial magnetic stimulation in these diseases has been increasingly suggested.To systematically review the effects of repetitive magnetic stimulation on non-neuronal cells two online databases.Web of Science and PubMed were searched fo r the effects of high-frequency-repetitive transcranial magnetic stimulation,low-frequencyrepetitive transcranial magnetic stimulation,intermittent theta-bu rst stimulation,continuous thetaburst stimulation,or repetitive magnetic stimulation on non-neuronal cells in models of disease and in unlesioned animals or cells.A total of 52 studies were included.The protocol more frequently used was high-frequency-repetitive magnetic stimulation,and in models of disease,most studies report that high-frequency-repetitive magnetic stimulation led to a decrease in astrocyte and mic roglial reactivity,a decrease in the release of pro-inflammatory cyto kines,and an increase of oligodendrocyte proliferation.The trend towards decreased microglial and astrocyte reactivity as well as increased oligodendrocyte proliferation occurred with intermittent theta-burst stimulation and continuous theta-burst stimulation.Few papers analyzed the low-frequency-repetitive transcranial magnetic stimulation protocol,and the parameters evaluated were restricted to the study of astrocyte reactivity and release of pro-inflammatory cytokines,repo rting the absence of effects on these paramete rs.In what concerns the use of magnetic stimulation in unlesioned animals or cells,most articles on all four types of stimulation reported a lack of effects.It is also important to point out that the studies were developed mostly in male rodents,not evaluating possible diffe rential effects of repetitive transcranial magnetic stimulation between sexes.This systematic review supports that thro ugh modulation of glial cells repetitive magnetic stimulation contributes to the neuroprotection or repair in various neurological disease models.Howeve r,it should be noted that there are still few articles focusing on the impact of repetitive magnetic stimulation on non-neuronal cells and most studies did not perform in-depth analyses of the effects,emphasizing the need for more studies in this field.展开更多
Nd-Fe-B permanent magnets play a crucial role in energy conversion and electronic devices.The essential magnetic properties of Nd-Fe-B magnets,particularly coercivity and remanent magnetization,are significantly infue...Nd-Fe-B permanent magnets play a crucial role in energy conversion and electronic devices.The essential magnetic properties of Nd-Fe-B magnets,particularly coercivity and remanent magnetization,are significantly infuenced by the phase characteristics and microstructure.In this work,Nd-Fe-B magnets were manufactured using vacuum induction melting(VIM),laser directed energy deposition(LDED)and laser powder bed fusion(LPBF)technologies.Themicrostructure evolution and phase selection of Nd-Fe-B magnets were then clarified in detail.The results indicated that the solidification velocity(V)and cooling rate(R)are key factors in the phase selection.In terms of the VIM-casting Nd-Fe-B magnet,a large volume fraction of theα-Fe soft magnetic phase(39.7 vol.%)and Nd2Fe17Bxmetastable phase(34.7 vol.%)areformed due to the low R(2.3×10-1?C s-1),whereas only a minor fraction of the Nd2Fe14B hard magnetic phase(5.15 vol.%)is presented.For the LDED-processed Nd-Fe-B deposit,although the Nd2Fe14B hard magnetic phase also had a low value(3.4 vol.%)as the values of V(<10-2m s-1)and R(5.06×103?C s-1)increased,part of theα-Fe soft magnetic phase(31.7vol.%)is suppressed,and a higher volume of Nd2Fe17Bxmetastable phases(47.5 vol.%)areformed.As a result,both the VIM-casting and LDED-processed Nd-Fe-B deposits exhibited poor magnetic properties.In contrast,employing the high values of V(>10-2m s-1)and R(1.45×106?C s-1)in the LPBF process resulted in the substantial formation of the Nd2Fe14B hard magnetic phase(55.8 vol.%)directly from the liquid,while theα-Fe soft magnetic phase and Nd2Fe17Bxmetastable phase precipitation are suppressed in the LPBF-processed Nd-Fe-B magnet.Additionally,crystallographic texture analysis reveals that the LPBF-processedNd-Fe-B magnets exhibit isotropic magnetic characteristics.Consequently,the LPBF-processed Nd-Fe-B deposit,exhibiting a coercivity of 656 k A m-1,remanence of 0.79 T and maximum energy product of 71.5 k J m-3,achieved an acceptable magnetic performance,comparable to other additive manufacturing processed Nd-Fe-B magnets from MQP(Nd-lean)Nd-Fe-Bpowder.展开更多
BACKGROUND High-grade pancreatic intraepithelial neoplasia(PanIN)exhibits no mass and is not detected by any examination modalities.However,it can be diagnosed by pancreatic juice cytology from indirect findings.Most ...BACKGROUND High-grade pancreatic intraepithelial neoplasia(PanIN)exhibits no mass and is not detected by any examination modalities.However,it can be diagnosed by pancreatic juice cytology from indirect findings.Most previous cases were diagnosed based on findings of a focal stricture of the main pancreatic duct(MPD)and caudal MPD dilatation and subsequent pancreatic juice cytology using endoscopic retrograde cholangiopancreatography(ERCP).We experienced a case of high-grade PanIN with an unclear MPD over a 20-mm range,but without caudal MPD dilatation on magnetic resonance cholangiopancreatography(MRCP).CASE SUMMARY A 60-year-old female patient underwent computed tomography for a follow-up of uterine cancer post-excision,which revealed pancreatic cysts.MRCP revealed an unclear MPD of the pancreatic body at a 20-mm length without caudal MPD dilatation.Thus,course observation was performed.After 24 mo,MRCP revealed an increased caudal MPD caliber and a larger pancreatic cyst.We performed ERCP and detected atypical cells suspected of adenocarcinoma by serial pancreatic juice aspiration cytology examination.We performed a distal pancreatectomy and obtained a histopathological diagnosis of high-grade PanIN.Pancreatic parenchyma invasion was not observed,and curative resection was achieved.CONCLUSION High-grade Pan-IN may cause MPD narrowing in a long range without caudal MPD dilatation.展开更多
基金supported by the National Natural Science Funds of China No.51907129Technology program of Liaoning province No.2021-MS-236。
文摘In this paper,a 20kW vehicle built-in permanent magnet synchronous motor is taken as an example,and a magnetic barrier structure is added to the rotor of the motor to solve the uneven saturation problem of the rotor side magnetic bridge.This structure improves the air-gap flux density waveform of the motor by influencing the internal magnetic flux path of the motor rotor,thus improving the sine of the no-load back EMF waveform of the motor and reducing the torque ripple of the motor.At the same time,Taguchi method is used to optimize the structural parameters of the added magnetic barrier.In order to facilitate the analysis of its uneven saturation phenomenon and improve the optimization effect,a simple equivalent magnetic network(EMN)model considering the uneven saturation of rotor magnetic bridge is established in this paper,and the initial values of optimization factors are selected based on this model.Finally,the no-load back EMF waveform distortion rate,torque ripple and output torque of the optimized motor are compared and analyzed,and the influence of magnetic barrier structure parameters on the electromagnetic performance of the motor is also analyzed.The results show that the optimized motor can not change the output torque of the motor as much as possible on the basis of reducing the waveform distortion rate of no-load back EMF and torque ripple.
文摘A magnetic bar carbon paste electrode (MBCPE) modified with Fe3O4 magnetic nanoparticles (Fe3O4NPs) and 2‐(3,4‐dihydroxyphenyl) benzothiazole (DPB) for the electrochemical determina‐tion of hydrazine was developed. The DPB was firstly self‐assembled on the Fe3O4NPs, and the re‐sulting Fe3O4NPs/DPB composite was then absorbed on the designed MBCPE. The MBCPE was used to attract the magnetic nanoparticles to the electrode surface. Owing to its high conductivity and large effective surface area, the novel electrode had a very large current response for the electrocat‐alytic oxidation of hydrazine. The modified electrode was characterized by voltammetry, scanning electron microscopy, electrochemical impedance spectroscopy, infrared spectroscopy, and UV‐visible spectroscopy. Voltammetric methods were used to study the electrochemical behaviour of hydrazine on MBCPE/Fe3O4NPs/DPB in phosphate buffer solution (pH = 7.0). The MBCPE/Fe3O4NPs/DPB, acting as an electrochemical sensor, exhibited very high electrocatalytic activity for the oxidation of hydrazine. The presence of DPB was found to reduce the oxidation potential of hydrazine and increase the catalytic current. The dependence of the electrocatalytic current on the hydrazine concentration exhibited two linear ranges, 0.1–0.4 μmol/L and 0.7–12.0 μmol/L, with a detection limit of 18.0 nmol/L. Additionally, the simultaneous determination of hydrazine and phe‐nol was investigated using the MBCPE/Fe3O4NPs/DPB electrode. Voltammetric experiments showed a linear range of 100–470 μmol/L and a detection limit of 24.3 μmol/L for phenol, and the proposed electrode was applied to the determination of hydrazine and phenol in water samples.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 10574042 and 10974052)the Specialized Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20060542002)
文摘The spin-dependent conductance and magnetoresistance ratio (MRR) for a semiconductor heterostructures consisting of two magnetic barriers with different height and space have been investigated by the transfer-matrix method. It is shown that the splitting of the conductance for parallel and antiparallel magnetization configurations results in tremendous spin-dependent MRR, and the maximal MRRs reach 5300% and 3800% for the magnetic barrier spaces W = 81.3 and 243.9 nm, respectively. The obtained spin-filtering transport property of nanostructures with magnetic barriers may be useful to magnetic-barrier-based spintronics.
基金The project supported by National Natural Science Foundation of China under Grant Nos. 10274069, 60471052, and 10347003, Natural Science Foundation of Zhejiang Province of China under Grant No. M603193, and the National Laboratory of Solid State Microstructures in Nanjing University under Grant No. M031802
文摘The spin-dependent transport properties in the non-collinear pattern of series of δ-magnetic barriers are studied by using scattering theory and Green's function methods. The Green's function is obtained by using distorted wave approach and the scattering matrix is related by Fisher-Lee relationship. In addition to reproducing the results of Papp's and Xu's in parallel and antiparallel configurations, we also obtain further results, where arbitrary orientations of the magnetic barriers and arbitrary number of barriers are included. The main finding of our results is that the signs of polarizations can be switched around some "geometric unpolarized windows". The well-known antiparallel configuration has no such characteristics. Furthermore, we discuss spin-related partial densities of states in both polarized and unpolarized structures.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 10821403 and 11047131)the National Basic Research Program of China(Grant No. 2009CB929100)the Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20101303120005)
文摘Because of the helicity of electrons in HgTe quantum wells(QWs) with inverted band structures,the electrons cannot be confined by electric barriers since electrons can tunnel the barriers perfectly without backscattering in the HgTe QWs.This behavior is similar to Dirac electrons in graphene.In this paper,we propose a scheme to confine carriers in HgTe QWs using an electric-magnetic barrier.We calculate the transmission of carriers in 2-dimensional HgTe QWs and find that the wave-vector filtering effect of local magnetic fields can confine the carriers.The confining effect will have a potential application in nanodevices based on HgTe QWs.
文摘The Magnetic Barkhausen Noise (MBN) technology is a non-destructive method to measure the neutral temperature of thc CWR track. A series of in-field verifications and data comparison on Australian mainline tracks have shown the results from that system are highly accurate and reliable. The system can be an accuracy and cost-effective tool to prevent the potential buckling and break of CWR rails. The physical backgrounds and features of the system are represented in this paper. The Darwin-Alice Springs Line is a newly constructed main line in Australia which is linked from the north and middle of Australia. Originally, this rail line is designed and constructed in a "cost-effective" way to a lower price, and the key parameters are relatively low. To maintain the stability of the CWR tracks in a very harsh environment, some new technologies such as the MBN technology were utilised. From the results of neutral temperature, it is found that the majority of them are very high. Combined with the calculation and finite element analysis, these problems evidenced that it is caused by the low toe load fastening system and high sleeper spacing. After that some suggestions are given to improve the stability of the CWR on the railway line.
文摘Magnetic Barkhausen Noise (MBN) is a phenomenon of electromagnetic energy emission due to the movement of magnetic domain walls inside ferromagnetic materials when they are locally magnetized by an alternating magnetic field. According to Faraday’s law of electromagnetic induction, the noise can be received by the coil attached to the surface of the material being magnetized and the noise carries the message of the characteristics of the material such as stresses, hardness, phase content, etc. Based on the characteristic of the noise, research about the relationship between the welding stresses in the welding assembly and the noise, the fatigue damage of the plate structure and the noise, and the influence of heat treatment and the variation of phase content to the noise are carried out in this paper.
文摘Hardened depths on steel samples are evaluated using a non-destructive technique based on the measurement of surface magnetic Barkhausen noise (MBN). Based on the results or experiments, the relation betweeu hardened depth and MBN is found, and a conclusion that the hardened depth can be measured by the way of measuring the MBN slgnals is obtained.
文摘Magnetic Barkhausen noise ( MBN) is a phenomenon of electromagnetic energy due to the movement of magnetic domain walls inside ferromagnetic materials when they are locally magnetized by an alternating magnetic fields. According to Faraday's law of electromagnetic induction, the noise can be received by the coil attached to the surface of the material being magnetized and the noise carries the message of the characteristics of the material such as stresses, hardness, phase content, etc. Based on the characteristic of the noise, researching about the relationship between the residual stress in the welding assembly and the noise are carried out. Furthermore, data process is performed by RMS (Root Mean Square) equation and Power Spectrum analysis.
文摘The Zeno time has been calculated for a metastable two-level atom tunneling through a interacting thermal magnetic field. The process of weak measurement has been utilized for the estimation of the timescale. Zeno time has been shown to be temperature dependent. From the calculation it is evident that the Zeno time decreases with the increase of temperature. Moreover, the result restricts the Zeno time to a maximum limiting value, irrespective of how frequent the measurement process is.
基金Project supported by the National Natural Science Foundation of China (Grant No. 52088101)the Kunpeng Plan of Zhejiang ProvinceNingbo Top Talent Program。
文摘Saturation magnetization,magneto-crystalline anisotropy field,and dielectric properties are closely related to microwave devices applied at different frequencies.For regulating the magnetic and dielectric properties of W-type barium ferrites,single-phase BaMe_(2)Fe_(16)O_(27)(Me=Fe,Mn,Zn,Ni,Co) with different Me ions were synthesized by the high-temperature solid-state method.The saturation magnetization(Ms) range from 47.77 emu/g to 95.34 emu/g and the magnetic anisotropy field(H_a) range from 10700.60 Oe(1 Oe=79.5775 A·m^(-1)) to 13739.57 Oe,depending on the type of cation substitution in the hexagonal lattice.The dielectric permittivity and dielectric loss decrease with increasing frequency of the AC electric field in the low-frequency region,while they almost remain constant in the high-frequency region.The charac teristics of easy regulation and preparation make it a potential candidate for use in microwave device applications.
基金supported by the Natural Science Foundation of Shanghai(No.23JC1400200)National Natural Science Foundation of China(Nos.12225502,12075061,and 12147101)National Key Research and Development Program of China(No.2022YFA1604900)。
文摘Although heavy-ion collisions generate strong magnetic fields,their direct measurement is a challenging task.A new observable,the baryon electric charge correlation,was recently found to be sensitive to the magnetic field strength and thus could be used as a magnetometer for heavy-ion collisions.Additionally,this observable may shed light on the equation of state and phase structure of quantum chromodynamics(QCD)under magnetic fields.Determining and understanding the phase structure of quantum chromodynamics(QCD)is important in contemporary physics[1].
基金Supported by Health Commission of Shanxi Province,No.2021XM39.
文摘BACKGROUND Percutaneous endoscopic lumbar decompression(PELD)shows promise for lumbar spinal stenosis(LSS)treatment,but its use is limited by the disease's complexity and procedural challenges.AIM In this study,the effects of preoperative planning and intraoperative guidance with computed tomography(CT)/magnetic resonance imaging(MRI)registration techniques on PELD for LSS and postoperative rehabilitation outcomes were evaluated.METHODS This retrospective study was conducted with data from patients who underwent PELD for LSS between January 2021 and December 2023.Patients were assigned to preoperative CT/MRI registration and control groups.Data collected included the operative time,length of hospital stay,visual analog scale(VAS)scores for low back and leg pain,and the Japanese Orthopaedic Association(JOA)lumbar spine score.Differences between groups were assessed using Student’s t test.RESULTS Data from 135 patients(71 in the CT/MRI registration group,64 in the control group)were analyzed.The operative time was significantly shorter in the CT/MRI registration group(P=0.007).At 2 months postoperatively,both groups showed significant reductions in VAS leg and low back pain scores(all P<0.001)and improvements in the JOA score(both P<0.001).No complication or death occurred.Preoperatively,pain and JOA scores were similar between groups(P=0.830,P=0.470,and P=0.287,respectively).At 2 months postoperatively,patients in the CT/MRI registration group reported lower leg and low back pain levels(P<0.001 and P=0.001,respectively)and had higher JOA scores(P=0.004)than did patients in the control group.CONCLUSION Preoperative CT/MRI registration for PELD for LSS reduced the operative time and VAS pain scores at 2 months and improved JOA scores,demonstrating enhanced effectiveness and safety.
基金supported by China Scholarship Council(202208210093,to RJ)。
文摘Cerebral small vessel disease is a neurological disease that affects the brain microvasculature and which is commonly observed among the elderly.Although at first it was considered innocuous,small vessel disease is nowadays regarded as one of the major vascular causes of dementia.Radiological signs of small vessel disease include small subcortical infarcts,white matter magnetic resonance imaging hyperintensities,lacunes,enlarged perivascular spaces,cerebral microbleeds,and brain atrophy;however,great heterogeneity in clinical symptoms is observed in small vessel disease patients.The pathophysiology of these lesions has been linked to multiple processes,such as hypoperfusion,defective cerebrovascular reactivity,and blood-brain barrier dysfunction.Notably,studies on small vessel disease suggest that blood-brain barrier dysfunction is among the earliest mechanisms in small vessel disease and might contribute to the development of the hallmarks of small vessel disease.Therefore,the purpose of this review is to provide a new foundation in the study of small vessel disease pathology.First,we discuss the main structural domains and functions of the blood-brain barrier.Secondly,we review the most recent evidence on blood-brain barrier dysfunction linked to small vessel disease.Finally,we conclude with a discussion on future perspectives and propose potential treatment targets and interventions.
基金supported by the National Natural Science Foundation of China,Nos.81672261(to XH),81972151(to HZ),82372568(to JL)the Natural Science Foundation of Guangdong Province,Nos.2019A1515011106(to HZ),2023A1515030080(to JL)。
文摘Prolife ration of neural stem cells is crucial for promoting neuronal regeneration and repairing cerebral infarction damage.Transcranial magnetic stimulation(TMS)has recently emerged as a tool for inducing endogenous neural stem cell regeneration,but its underlying mechanisms remain unclea r In this study,we found that repetitive TMS effectively promotes the proliferation of oxygen-glucose deprived neural stem cells.Additionally,repetitive TMS reduced the volume of cerebral infa rction in a rat model of ischemic stro ke caused by middle cerebral artery occlusion,im p roved rat cognitive function,and promoted the proliferation of neural stem cells in the ischemic penumbra.RNA-sequencing found that repetitive TMS activated the Wnt signaling pathway in the ischemic penumbra of rats with cerebral ischemia.Furthermore,PCR analysis revealed that repetitive TMS promoted AKT phosphorylation,leading to an increase in mRNA levels of cell cycle-related proteins such as Cdk2 and Cdk4.This effect was also associated with activation of the glycogen synthase kinase 3β/β-catenin signaling pathway,which ultimately promotes the prolife ration of neural stem cells.Subsequently,we validated the effect of repetitive TMS on AKT phosphorylation.We found that repetitive TMS promoted Ca2+influx into neural stem cells by activating the P2 calcium channel/calmodulin pathway,thereby promoting AKT phosphorylation and activating the glycogen synthase kinase 3β/β-catenin pathway.These findings indicate that repetitive TMS can promote the proliferation of endogenous neural stem cells through a Ca2+influx-dependent phosphorylated AKT/glycogen synthase kinase 3β/β-catenin signaling pathway.This study has produced pioneering res ults on the intrinsic mechanism of repetitive TMS to promote neural function recove ry after ischemic stro ke.These results provide a stro ng scientific foundation for the clinical application of repetitive TMS.Moreover,repetitive TMS treatment may not only be an efficient and potential approach to support neurogenesis for further therapeutic applications,but also provide an effective platform for the expansion of neural stem cells.
基金supported by the National Key Research and Development Program of China(Grant Nos.2023YFF0719200 and 2022YFA1404004)the National Natural Science Foundation of China(Grant Nos.61988102,62322115,61975110,and 62335012)+3 种基金the 111 Project(Grant No.D18014)the Key Project supported by Science and Technology Commission Shanghai Municipality(Grant No.YDZX20193100004960)Science and Technology Commission of Shanghai Municipality(Grant No.22JC1400200)General Administration of Customs People’s Republic of China(Grant No.2019HK006)。
文摘Using THz emission spectroscopy,we investigate the elementary spin dynamics in ferromagnetic single-layer Fe on a sub-picosecond timescale.We demonstrate that THz radiation changes its polarity with reversal of the magnetization applied by the external magnetic field.In addition,it is found that the sign of THz polarity excited from different sides is defined by the thickness of the Fe layer and Fe/dielectric interface.Based on the thickness and symmetry dependences of THz emission,we experimentally distinguish between the two major contributions:ultrafast demagnetization and the anomalous Hall effect.Our experimental results not only enrich understanding of THz electromagnetic generation induced by femtosecond laser pulses but also provide a practical way to access laser-induced ultrafast spin dynamics in magnetic structures.
文摘BACKGROUND Perineural invasion(PNI)has been used as an important pathological indicator and independent prognostic factor for patients with rectal cancer(RC).Preoperative prediction of PNI status is helpful for individualized treatment of RC.Recently,several radiomics studies have been used to predict the PNI status in RC,demonstrating a good predictive effect,but the results lacked generalizability.The preoperative prediction of PNI status is still challenging and needs further study.AIM To establish and validate an optimal radiomics model for predicting PNI status preoperatively in RC patients.METHODS This retrospective study enrolled 244 postoperative patients with pathologically confirmed RC from two independent centers.The patients underwent preoperative high-resolution magnetic resonance imaging(MRI)between May 2019 and August 2022.Quantitative radiomics features were extracted and selected from oblique axial T2-weighted imaging(T2WI)and contrast-enhanced T1WI(T1CE)sequences.The radiomics signatures were constructed using logistic regression analysis and the predictive potential of various sequences was compared(T2WI,T1CE and T2WI+T1CE fusion sequences).A clinical-radiomics(CR)model was established by combining the radiomics features and clinical risk factors.The internal and external validation groups were used to validate the proposed models.The area under the receiver operating characteristic curve(AUC),DeLong test,net reclassification improvement(NRI),integrated discrimination improvement(IDI),calibration curve,and decision curve analysis(DCA)were used to evaluate the model performance.RESULTS Among the radiomics models,the T2WI+T1CE fusion sequences model showed the best predictive performance,in the training and internal validation groups,the AUCs of the fusion sequence model were 0.839[95%confidence interval(CI):0.757-0.921]and 0.787(95%CI:0.650-0.923),which were higher than those of the T2WI and T1CE sequence models.The CR model constructed by combining clinical risk factors had the best predictive performance.In the training and internal and external validation groups,the AUCs of the CR model were 0.889(95%CI:0.824-0.954),0.889(95%CI:0.803-0.976)and 0.894(95%CI:0.814-0.974).Delong test,NRI,and IDI showed that the CR model had significant differences from other models(P<0.05).Calibration curves demonstrated good agreement,and DCA revealed significant benefits of the CR model.CONCLUSION The CR model based on preoperative MRI radiomics features and clinical risk factors can preoperatively predict the PNI status of RC noninvasively,which facilitates individualized treatment of RC patients.
基金the scope of the CICS-UBI projects UIDP/Multi/00709/2019,UIDB/Multi/00709/2019,UIDP/00709/2020,UIDB/00709/2020,financed by national funds through the Portuguese Foundation for Science and Technology/MCTESby funds to the PPBI-Portuguese Platform of Bio Imaging through the Project POCI-01-0145-FEDER-022122(to GB,MVP,NP)supported by a grant from the Portuguese Foundation for Science and Technology/MCTES(2021.07854.BD)(to IS)。
文摘Repetitive transcranial magnetic stimulation has been increasingly studied in different neurological diseases,and although most studies focus on its effects on neuronal cells,the contribution of nonneuronal cells to the improvement trigge red by repetitive transcranial magnetic stimulation in these diseases has been increasingly suggested.To systematically review the effects of repetitive magnetic stimulation on non-neuronal cells two online databases.Web of Science and PubMed were searched fo r the effects of high-frequency-repetitive transcranial magnetic stimulation,low-frequencyrepetitive transcranial magnetic stimulation,intermittent theta-bu rst stimulation,continuous thetaburst stimulation,or repetitive magnetic stimulation on non-neuronal cells in models of disease and in unlesioned animals or cells.A total of 52 studies were included.The protocol more frequently used was high-frequency-repetitive magnetic stimulation,and in models of disease,most studies report that high-frequency-repetitive magnetic stimulation led to a decrease in astrocyte and mic roglial reactivity,a decrease in the release of pro-inflammatory cyto kines,and an increase of oligodendrocyte proliferation.The trend towards decreased microglial and astrocyte reactivity as well as increased oligodendrocyte proliferation occurred with intermittent theta-burst stimulation and continuous theta-burst stimulation.Few papers analyzed the low-frequency-repetitive transcranial magnetic stimulation protocol,and the parameters evaluated were restricted to the study of astrocyte reactivity and release of pro-inflammatory cytokines,repo rting the absence of effects on these paramete rs.In what concerns the use of magnetic stimulation in unlesioned animals or cells,most articles on all four types of stimulation reported a lack of effects.It is also important to point out that the studies were developed mostly in male rodents,not evaluating possible diffe rential effects of repetitive transcranial magnetic stimulation between sexes.This systematic review supports that thro ugh modulation of glial cells repetitive magnetic stimulation contributes to the neuroprotection or repair in various neurological disease models.Howeve r,it should be noted that there are still few articles focusing on the impact of repetitive magnetic stimulation on non-neuronal cells and most studies did not perform in-depth analyses of the effects,emphasizing the need for more studies in this field.
基金supported by the National Key R&D Program of China(Grant No.2022YFB4600300)the National Natural Science Foundation of China(No.U22A20189,52175364)the China Scholarship Council(Grant No.202206290134)。
文摘Nd-Fe-B permanent magnets play a crucial role in energy conversion and electronic devices.The essential magnetic properties of Nd-Fe-B magnets,particularly coercivity and remanent magnetization,are significantly infuenced by the phase characteristics and microstructure.In this work,Nd-Fe-B magnets were manufactured using vacuum induction melting(VIM),laser directed energy deposition(LDED)and laser powder bed fusion(LPBF)technologies.Themicrostructure evolution and phase selection of Nd-Fe-B magnets were then clarified in detail.The results indicated that the solidification velocity(V)and cooling rate(R)are key factors in the phase selection.In terms of the VIM-casting Nd-Fe-B magnet,a large volume fraction of theα-Fe soft magnetic phase(39.7 vol.%)and Nd2Fe17Bxmetastable phase(34.7 vol.%)areformed due to the low R(2.3×10-1?C s-1),whereas only a minor fraction of the Nd2Fe14B hard magnetic phase(5.15 vol.%)is presented.For the LDED-processed Nd-Fe-B deposit,although the Nd2Fe14B hard magnetic phase also had a low value(3.4 vol.%)as the values of V(<10-2m s-1)and R(5.06×103?C s-1)increased,part of theα-Fe soft magnetic phase(31.7vol.%)is suppressed,and a higher volume of Nd2Fe17Bxmetastable phases(47.5 vol.%)areformed.As a result,both the VIM-casting and LDED-processed Nd-Fe-B deposits exhibited poor magnetic properties.In contrast,employing the high values of V(>10-2m s-1)and R(1.45×106?C s-1)in the LPBF process resulted in the substantial formation of the Nd2Fe14B hard magnetic phase(55.8 vol.%)directly from the liquid,while theα-Fe soft magnetic phase and Nd2Fe17Bxmetastable phase precipitation are suppressed in the LPBF-processed Nd-Fe-B magnet.Additionally,crystallographic texture analysis reveals that the LPBF-processedNd-Fe-B magnets exhibit isotropic magnetic characteristics.Consequently,the LPBF-processed Nd-Fe-B deposit,exhibiting a coercivity of 656 k A m-1,remanence of 0.79 T and maximum energy product of 71.5 k J m-3,achieved an acceptable magnetic performance,comparable to other additive manufacturing processed Nd-Fe-B magnets from MQP(Nd-lean)Nd-Fe-Bpowder.
文摘BACKGROUND High-grade pancreatic intraepithelial neoplasia(PanIN)exhibits no mass and is not detected by any examination modalities.However,it can be diagnosed by pancreatic juice cytology from indirect findings.Most previous cases were diagnosed based on findings of a focal stricture of the main pancreatic duct(MPD)and caudal MPD dilatation and subsequent pancreatic juice cytology using endoscopic retrograde cholangiopancreatography(ERCP).We experienced a case of high-grade PanIN with an unclear MPD over a 20-mm range,but without caudal MPD dilatation on magnetic resonance cholangiopancreatography(MRCP).CASE SUMMARY A 60-year-old female patient underwent computed tomography for a follow-up of uterine cancer post-excision,which revealed pancreatic cysts.MRCP revealed an unclear MPD of the pancreatic body at a 20-mm length without caudal MPD dilatation.Thus,course observation was performed.After 24 mo,MRCP revealed an increased caudal MPD caliber and a larger pancreatic cyst.We performed ERCP and detected atypical cells suspected of adenocarcinoma by serial pancreatic juice aspiration cytology examination.We performed a distal pancreatectomy and obtained a histopathological diagnosis of high-grade PanIN.Pancreatic parenchyma invasion was not observed,and curative resection was achieved.CONCLUSION High-grade Pan-IN may cause MPD narrowing in a long range without caudal MPD dilatation.