期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Effect of power supply parameters on discharge characteristics and sterilization efficiency of magnetically driven rotating gliding arc
1
作者 Shaohua QIN Meizhi WANG +2 位作者 Jun DU Lanlan NIE Jie PAN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第9期61-68,共8页
Plasma sterilization is a new generation of high-tech sterilization method that is fast,safe,and pollution free.It is widely used in medical,food,and environmental protection fields.Home air sterilization is an emergi... Plasma sterilization is a new generation of high-tech sterilization method that is fast,safe,and pollution free.It is widely used in medical,food,and environmental protection fields.Home air sterilization is an emerging field of plasma application,which puts higher requirements on the miniaturization,operational stability,and operating cost of plasma device.In this study,a novel magnetically driven rotating gliding arc(MDRGA)discharge device was used to sterilize Lactobacillus fermentation.Compared with the traditional gas-driven gliding arc,this device has a simple structure and a more stable gliding arc.Simulation using COMSOL Multiphysics showed that adding permanent magnets can form a stable magnetic field,which is conducive to the formation of gliding arcs.Experiments on the discharge performance,ozone concentration,and sterilization effect were conducted using different power supply parameters.The results revealed that the MDRGA process can be divided into three stages:starting,gliding,and extinguishing.Appropriate voltage was the key factor for stable arc gliding,and both high and low voltages were not conducive to stable arc gliding and ozone production.In this experimental setup,the sterilization effect was the best at 6.6 kV.A high modulation duty ratio was beneficial for achieving stable arc gliding.However,when the duty ratio exceeded a certain value,the improvement in the sterilization effect was slow.Therefore,considering the sterilization effect and energy factors comprehensively,we chose 80%as the optimal modulation duty ratio for this experimental device. 展开更多
关键词 PLASMA magnetically driven rotating gliding arc STERILIZATION
下载PDF
Study and Measurement of Glidarc Driven by Magnetic Field 被引量:3
2
作者 赵宇含 马强 夏维东 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第1期65-69,共5页
Non-thermal plasma at atmosphere was generated through glidarc discharge driven by magnetic field and observed by using a high speed charge coupled device (CCD) and photo multiplier tube (PMT). The arc diameter pr... Non-thermal plasma at atmosphere was generated through glidarc discharge driven by magnetic field and observed by using a high speed charge coupled device (CCD) and photo multiplier tube (PMT). The arc diameter projecting in the direction of arc motion (front-viewed diameter) and the diameter projecting in the perpendicular direction of arc motion (side-viewed diameter) were measured. The effect of both the arc current and the magnetic field was analysed. The front-viewed diameter was compared with the side-viewed one. Simultaneously the electricfield intensity was measured directly and analysed by considering the effect of the external magnetic field and arc current. 展开更多
关键词 glidarc driven by magnetism arc diameter electric-field intensity
下载PDF
Targeted therapeutic effects of oral magnetically driven pectin nanoparticles containing chlorogenic acid on colon cancer 被引量:1
3
作者 Huatai Zhu Limei Zhang +3 位作者 Fujia Kou Jingyang Zhao Jiandu Lei Jing He 《Particuology》 SCIE EI CAS CSCD 2024年第1期53-59,共7页
Oral colonic nano-drug delivery system has attracted growing attention in treating colon cancer for their excellent characteristics.However,the unique and complex structure of the gastrointestinal tract is still an ob... Oral colonic nano-drug delivery system has attracted growing attention in treating colon cancer for their excellent characteristics.However,the unique and complex structure of the gastrointestinal tract is still an obstacle to the safe delivery of drugs targeting sites in colon tumors.Here,we designed magnetically driven dual-targeted oral colonic nanoparticles loaded with chlorogenic acid using pectin and oleic acid-modified iron oxide(Fe3O4@OA).Specific degradation of pectin by pectinase produced by colonic flora and magnetic fields applied to the colon confers specific targeting of nanoparticles to the colon.In order to overcome the challenge of preparing magnetically driven nanoparticles with small and homogeneous particle sizes by a single conventional method,we developed the combined ultrasound-emulsification technique.The average particle size of the prepared nanoparticles was 81.04±1.02 nm,which showed good drug release in the simulated colonic environment.In vitro anticancer studies,the drug-loaded nanoparticles possess an obvious toxicity and apoptosis-inducing ability against cancer cells.Meanwhile,the hemolysis results demonstrated the safety of the nanoplatform(PET/CGA/Fe_(3)O_(4)@OA).This work holds broad prospects as a new treatment modality for colon cancer. 展开更多
关键词 PECTIN Chlorogenic acid Ultrasound-emulsion magnetically driven Colon cancer Colon targeted
原文传递
Mathematical Modeling of ESR Process for Hollow Ingot with Current Supplying Mould 被引量:2
4
作者 Xu CHEN Fu-bin LIU +3 位作者 Zhou-hua JIANG Hua-bing LI Xi-min ZANG Xin DENG 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2015年第3期192-199,共8页
With ificreasing demand for large cylindrical forgings, a new technology--electroslag remelting (ESR) for direct manufacture of hollow ingots rather than solid ingots has been developed. The main features of the pro... With ificreasing demand for large cylindrical forgings, a new technology--electroslag remelting (ESR) for direct manufacture of hollow ingots rather than solid ingots has been developed. The main features of the process include a T-shaped current supplying mould (CSM), double power supply, an ingot withdrawing system, a metal level automatic control system based on a level sensor using the electromagnetic eddy current method, and the exchange of a consumable multi-electrode. ANSYS software was used to calculate the fluid flow and heat transfer in the slag bath 1 and metal pool of this ESR hollow ingot process with its T-shaped CSM. The mathematmal model was Verified by measuring the geometry of the liquid metal pool as observed in the macrostructure of 4650 mm (external diameter)/ 4450 mm (internal diameter) hollow ingots by sulphur print method: the. observed shape and depth of the s!ag bath were consistent with the simulated results. Simulation of the ESR process can improve understanding of the process and allow better operating parameters to be selected. 展开更多
关键词 electroslag remelting hollow ingot T-shaped current supplying mould temperature field magnetically driven fluid flow finite element method
原文传递
Ball-disk rotor gyroscope adaptive quick-start technique
5
作者 Xiao-wei LIU Rui WENG +1 位作者 Hai LI Hai-feng ZHANG 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2017年第9期1430-1436,共7页
Rotating speed is a critical parameter affecting the performance of rotor gyroscopes. Rotor gyroscopes must operate at the rated rotating speed. To shorten the start time of the ball-disk rotor gyroscope, this paper p... Rotating speed is a critical parameter affecting the performance of rotor gyroscopes. Rotor gyroscopes must operate at the rated rotating speed. To shorten the start time of the ball-disk rotor gyroscope, this paper presents a new design of the drive system for a ball-disk rotor gyroscope. The drive system is monitored by a microeontroUer. First, the microcontroller generates a sine pulse width modulation signal to drive the permanent magnet rotor. Second, the position of the rotor is detected according to the back electromotive force in the non-energized coil. Third, a piecewise closed-loop control algorithm is implemented to keep the angular acceleration of the rotor within the safe range automatically during the acceleration process and when running at a constant speed. This control algorithm can avoid rotor stalling due to loss of steps. Experimental result shows that with the help of adaptive quick-start technique, the start time of the device can be shortened by up to 36.6%. 展开更多
关键词 Rotor gyroscope magnetically driven Quick start Piecewise algorithm Closed-loop control
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部