Using the method of Picus and Beer invariants, general expressions are obtained for the total intensity I and the degree of circular polarization Рcirc.of the luminescence of GaAs-type semiconductors with the partici...Using the method of Picus and Beer invariants, general expressions are obtained for the total intensity I and the degree of circular polarization Рcirc.of the luminescence of GaAs-type semiconductors with the participation of shallow acceptor levels in a longitudinal magnetic field H. Special cases are analyzed depending on the value and direction of the magnetic field strength, as well as on the constants of the g-factor of the acceptor g1,g2and the conduction band electron ge. In the case of a strong magnetic field H// [100], [111], [110], a numerical calculation of the angular dependence of the quantities I and Рcirc.was performed for some critical values of g2/g1, at which Рcirc.exhibits a sharp anisotropy in the range from −100% to +100%, and the intensity of the crystal radiation along the magnetic field tends to a minimum value.展开更多
The configuration, magnetic field calculation and field distribution of the birdcage RF coil is pre-sented. This type of coil can produce a circular Polarized magnetic field. It has been widely used in the MRIsystem f...The configuration, magnetic field calculation and field distribution of the birdcage RF coil is pre-sented. This type of coil can produce a circular Polarized magnetic field. It has been widely used in the MRIsystem for head and whole-body imaging which can achive nearly optimal RF field uniformity and signal-to-noise ratio(SNR). The rnagnetic field is evenly distributed over the coil. The features of the birdcage coil areanalyzed on the basis of numerical simulation and experimental studies.展开更多
文摘Using the method of Picus and Beer invariants, general expressions are obtained for the total intensity I and the degree of circular polarization Рcirc.of the luminescence of GaAs-type semiconductors with the participation of shallow acceptor levels in a longitudinal magnetic field H. Special cases are analyzed depending on the value and direction of the magnetic field strength, as well as on the constants of the g-factor of the acceptor g1,g2and the conduction band electron ge. In the case of a strong magnetic field H// [100], [111], [110], a numerical calculation of the angular dependence of the quantities I and Рcirc.was performed for some critical values of g2/g1, at which Рcirc.exhibits a sharp anisotropy in the range from −100% to +100%, and the intensity of the crystal radiation along the magnetic field tends to a minimum value.
文摘The configuration, magnetic field calculation and field distribution of the birdcage RF coil is pre-sented. This type of coil can produce a circular Polarized magnetic field. It has been widely used in the MRIsystem for head and whole-body imaging which can achive nearly optimal RF field uniformity and signal-to-noise ratio(SNR). The rnagnetic field is evenly distributed over the coil. The features of the birdcage coil areanalyzed on the basis of numerical simulation and experimental studies.