The research of high-performance polarization controllers is of great significance for expanding the application field of polarization optics. Here, a polarization switch is demonstrated by using a dual-core photonic ...The research of high-performance polarization controllers is of great significance for expanding the application field of polarization optics. Here, a polarization switch is demonstrated by using a dual-core photonic crystal fiber(DCPCF)with four symmetrical air holes, placed above and below each core, filled with magnetic fluid(MF). The switch, which utilizes a magnetic field to change the coupling length ratio of the x and y polarization modes, enables dynamic tuning of the polarization state and extinction ratio. Numerical results show that when the working length is 36.638 mm, the magneto–optical polarization switch can operate in four communication bands, i.e., 1509 nm to 1520 nm, 1544 nm to1556 nm, 1578 nm to 1591 nm, and 1611 nm to 1624 nm. Moreover, the extinction ratio(ER) is greater than 20 d B in the fiber length range of 38.5 mm to 38.7 mm, indicating that the device has a good fault tolerance for the interception of the fiber length.展开更多
Sealing is one of the most successful apphcatious of magnetic fluids. However, the sealing pressure difference is not satisfactory. This paper theoretically analyzes the mechanism of magnetic fluids sealing. Main fact...Sealing is one of the most successful apphcatious of magnetic fluids. However, the sealing pressure difference is not satisfactory. This paper theoretically analyzes the mechanism of magnetic fluids sealing. Main factors that have significant effects on the sealing ability include viscous stress on the interracial surface, magnetic surface tension, and the shape of the interracial surface. The sealing pressure with magnetic fluids decreases with increase of rotational speed. Experiments were carried out to study the stability of the interface between magnetic fluids and water. It has been shown that stability of the interface will be damaged by washing of water when the relative flow between water and magnetic fluid becomes turbulent.展开更多
An all-fiber optical modulator, which is composed of a piece of no-core fiber spliced between two sections of singlemode fibers and uses magnetic fluid(MF) as the cladding of the no-core fiber section, is proposed a...An all-fiber optical modulator, which is composed of a piece of no-core fiber spliced between two sections of singlemode fibers and uses magnetic fluid(MF) as the cladding of the no-core fiber section, is proposed and investigated experimentally. Due to the tunable refractive index and absorption coefficient of MF, the output intensity can be modulated by controlling an applied magnetic field. The dependences of the modulator's temporal response on the working wavelength,the magnetic field strength(H), and the MF's concentration are investigated experimentally. The results are explained qualitatively by the dynamic response process of MF under the action of a magnetic field. The findings are helpful for optimizing this kind of modulator.展开更多
Compared with traditional mechanical seals,magnetic fluid seals have unique characters of high airtightness,minimal friction torque requirements,pollution-free and long life-span,widely used in vacuum robots.With the ...Compared with traditional mechanical seals,magnetic fluid seals have unique characters of high airtightness,minimal friction torque requirements,pollution-free and long life-span,widely used in vacuum robots.With the rapid development of Integrate Circuit(IC),there is a stringent requirement for sealing wafer-handling robots when working in a vacuum environment.The parameters of magnetic fluid seals structure is very important in the vacuum robot design.This paper gives a magnetic fluid seal device for the robot.Firstly,the seal differential pressure formulas of magnetic fluid seal are deduced according to the theory of ferrohydrodynamics,which indicate that the magnetic field gradient in the sealing gap determines the seal capacity of magnetic fluid seal.Secondly,the magnetic analysis model of twin-shaft magnetic fluid seals structure is established.By analyzing the magnetic field distribution of dual magnetic fluid seal,the optimal value ranges of important parameters,including parameters of the permanent magnetic ring,the magnetic pole tooth,the outer shaft,the outer shaft sleeve and the axial relative position of two permanent magnetic rings,which affect the seal differential pressure,are obtained.A wafer-handling robot equipped with coaxial twin-shaft magnetic fluid rotary seals and bellows seal is devised and an optimized twin-shaft magnetic fluid seals experimental platform is built.Test result shows that when the speed of the two rotational shafts ranges from 0-500 r/min,the maximum burst pressure is about 0.24 MPa.Magnetic fluid rotary seals can provide satisfactory performance in the application of wafer-handling robot.The proposed coaxial twin-shaft magnetic fluid rotary seal provides the instruction to design high-speed vacuum robot.展开更多
Magnetic fluid is a kind of functional composite material with nanosized structure and unique optical properties. The tunable magneto-optic modulation of magnetic fluid under external magnetic field, achieved by adjus...Magnetic fluid is a kind of functional composite material with nanosized structure and unique optical properties. The tunable magneto-optic modulation of magnetic fluid under external magnetic field, achieved by adjusting the polarization direction of incident light, is investigated theoretically and experimentally in this work. The corresponding modulation depth and response time are obtained. The accompanying mechanisms are clarified by using the theory of dichroism of magtietic fluid and the aggregation/disintegration processes of magnetic particles within magnetic fluid when the external magnetic field turns on/off.展开更多
A kind of photonic crystal (PC) micro-cavity sensor based on magnetic fluid (MF) filling is designed with simulation model. Generally, many sensors’ designs are based on a universal temperature in the whole structure...A kind of photonic crystal (PC) micro-cavity sensor based on magnetic fluid (MF) filling is designed with simulation model. Generally, many sensors’ designs are based on a universal temperature in the whole structure. However, strong photothermal effect in high Q micro-cavities will lead to different temperatures between cavities and environment inevitably. In many theoretical PC sensor designs, researchers neglected the different temperature between environment and cavities. This simple hypothesis will probably lead to failure of sensor design and get wrong temperature. Moreover, few theoretical or experimental works have been done to study optical cavity’s heating process and temperature. We propose that researchers should take seriously about this point. Here, the designed cascaded micro-cavity structure has three spectral lines and a reversible sensitivity matrix, which can simultaneously detect magnetic field, ambient temperature and MF micro-cavity temperature. It can solve the magnetic field and temperature cross-sensitivity problem, and further, distinguish the different temperatures of environment and magnetic fluid cavities. The influence of hole radius and slab thickness on the depth and Q value of the resonant spectral line are also studied. Responses of three dips to magnetic field, ambient temperature and MF micro-cavity temperature are simulated, respectively, where dip 1 belongs to MF cavity 1, dip 2 and dip 3 belong to MF cavity 2. The obtained magnetic field sensitivities are 2.89 pm/Oe, 4.57 pm/Oe, and 5.14 pm/Oe, respectively;the ambient temperature sensitivities are 65.51 pm/K, 50.94 pm/K, and 58.98 pm/K, respectively;and the MF micro-cavity temperature sensitivities are −14.41 pm/K, −17.06 pm/K, and −18.81 pm/K, respectively.展开更多
Fe_3O_4/Polystyrene(PSt) magnetic particles with core/shell structure have been prepared in thepresence of Fe_3O_4 magnetic fluid in ethanol/water medium by dispersion polymeriation of styrene. A Fe_3O_4particle forma...Fe_3O_4/Polystyrene(PSt) magnetic particles with core/shell structure have been prepared in thepresence of Fe_3O_4 magnetic fluid in ethanol/water medium by dispersion polymeriation of styrene. A Fe_3O_4particle formation mechanism was proposed. According to this mechanism, the size of particle nuclei isdetermined by the extent of aggregation of Fe_3O_4 /oligomer. Magnetic particles with diameter ranging from 5to 200 μm were prepared under different reaction conditions. Some polymerization parameters such as theconcentration of monomer, stabilizer, initiator, and ethanol which affect particle size and size distribution arediscussed and their effect on particle formation are explained by the proposed mechanism.展开更多
A new controllable laser beam shaping technique is demonstrated, where a magnetic fluid-based liquid deformable mirror is proposed to redistribute the laser phase profile and thus change the propagation property of th...A new controllable laser beam shaping technique is demonstrated, where a magnetic fluid-based liquid deformable mirror is proposed to redistribute the laser phase profile and thus change the propagation property of the beam. The mirror is driven by an inner miniature actuator array along with a large outer actuator. The inner actuator array is used for deforming the magnetic fluid surface, while the outer actuator is used to linearize the fluid surface response and amplify the magnitude of the deflection. In comparison to other laser beam shaping techniques, this technique offers the advantages such as simplicity, low cost, large shape deformation, and high adaptability. Based on a fabricated prototype of the liquid deformable mirror, an experimental AO system was set up to produce a desired conical surface shape that shaped the incident beam into a Bessel beam. The experimental results show the effectiveness of the proposed technique for laser beam shaping.展开更多
In this work,we present a theoretical study on the stability of a two-dimensional plane Poiseuille flow of magnetic fluids in the presence of externally applied magnetic fields.The fluids are assumed to be incompressi...In this work,we present a theoretical study on the stability of a two-dimensional plane Poiseuille flow of magnetic fluids in the presence of externally applied magnetic fields.The fluids are assumed to be incompressible,and their magnetization is coupled to the flow through a simple phenomenological equation.Dimensionless parameters are defined,and the equations are perturbed around the base state.The eigenvalues of the linearized system are computed using a finite difference scheme and studied with respect to the dimensionless parameters of the problem.We examine the cases of both the horizontal and vertical magnetic fields.The obtained results indicate that the flow is destabilized in the horizontally applied magnetic field,but stabilized in the vertically applied field.We characterize the stability of the flow by computing the stability diagrams in terms of the dimensionless parameters and determine the variation in the critical Reynolds number in terms of the magnetic parameters.Furthermore,we show that the superparamagnetic limit,in which the magnetization of the fluids decouples from hydrodynamics,recovers the same purely hydrodynamic critical Reynolds number,regardless of the applied field direction and of the values of the other dimensionless magnetic parameters.展开更多
The model of using colloidal magnetic fluid to build tunable negative-index photonic crystal is established. The effective permittivity εe and permeability μe of the two-dimensional photonic crystal are investigated...The model of using colloidal magnetic fluid to build tunable negative-index photonic crystal is established. The effective permittivity εe and permeability μe of the two-dimensional photonic crystal are investigated in detail. For transverse magnetic polarization, both εe and μe exhibit a Lorentz-type anomalous dispersion, leading to a region where εe and μe are simultaneously negative. Then, considering a practical case, in which the thickness of photonic crystal is finite, the band structures for odd modes are calculated by the plane wave expansion method and the finite-difference time-domain method. The results suggest that reducing the external magnetic field strength or slab thickness will weaken the periodic modulation strength of the photonic crystal. Simulation results prove that the negative-index can be tuned by varying the external magnetic field strength or the slab thickness. The work presented in this paper gives a guideline for realizing the flat photonic crystal lens with tunable properties at optical frequencies, which may have potential applications in tunable near-field imaging systems.展开更多
We propose a novel light intensity modulator based on magnetic fluid and liquid crystal(LC) filled photonic crystal fibers(PCFs). The influences of electric and magnetic fields on the transmission intensity are th...We propose a novel light intensity modulator based on magnetic fluid and liquid crystal(LC) filled photonic crystal fibers(PCFs). The influences of electric and magnetic fields on the transmission intensity are theoretically and experimentally analyzed and investigated. Both the electric and magnetic fields can manipulate the molecular arrangement of LC to array a certain angle without changing the refractive index of the LC. Therefore, light loss in the PCF varies with the electric and magnetic fields whereas the peak wavelengths remain constant. The experimental results show that the transmission intensity decreases with the increase of the electric and magnetic fields. The cut-off electric field is 0.899 V/um at 20 Hz and the cut-off magnetic field is 195 m T. This simple and compacted optical modulator will have a great prospect in sensing applications.展开更多
This paper analyzes the sources of heat losses in magnetic fluid bearings,proposes various cou-pling relationships of physical fields,divides the coupled heat transfer surfaces while ensuring the continuity of heat fl...This paper analyzes the sources of heat losses in magnetic fluid bearings,proposes various cou-pling relationships of physical fields,divides the coupled heat transfer surfaces while ensuring the continuity of heat flux density,and analyzes the overall heat dissipation pathways of the bearings.By changing parameters such as input current,rotor speed,and inlet oil flow rate,the study applies a multi-physics field coupling method to investigate the influence of different parameters on the temper-ature field and heat dissipation patterns of the bearings,which is then validated through experi-ments.This research provides a theoretical basis for the optimal design of magnetic fluid bearing sys-tems.展开更多
Magnetic fluids are the suspensions composed of magnetic nanoparticles,surfactants,and non-magnetic carrier liquids.Magnetic fluids are widely used in various fields,especially in sealing,because of their excellent fe...Magnetic fluids are the suspensions composed of magnetic nanoparticles,surfactants,and non-magnetic carrier liquids.Magnetic fluids are widely used in various fields,especially in sealing,because of their excellent features,including rapid magnetic response,flexible flow ability,tunable magneto-viscous effect,and reliable self-repairing capability.Here,we provide an in-depth,comprehensive insight into the theoretical analyses and diverse applications of magnetic fluids in sealing from three categories:static sealing,rotary sealing,and reciprocating sealing.We summarize the magnetic fluid sealing mechanisms and the development of magnetic fluid seals from 1960s to the present,particularly focusing on the recent progress of magnetic fluid seals.Although magnetic fluid sealing technology has been commercialized and industrialized,many difficulties still exist in its applications.At the end of the review,the present challenges and future prospects in the progress of magnetic fluid seals are also outlined.展开更多
Magnetohydrodynamic(MHD)induction pumps are contactless pumps able to withstand harsh environments.The rate of fluid flow through the pump directly affects the efficiency and stability of the device.To explore the inf...Magnetohydrodynamic(MHD)induction pumps are contactless pumps able to withstand harsh environments.The rate of fluid flow through the pump directly affects the efficiency and stability of the device.To explore the influence of induction pump settings on the related delivery speed,in this study,a numerical model for coupled electromagnetic and flow field effects is introduced and used to simulate liquid metal lithium flow in the induction pump.The effects of current intensity,frequency,coil turns and coil winding size on the velocity of the working fluid are analyzed.It is shown that the first three parameters have a significant impact,while changes in the coil turns have a negligible influence.The maximum increase in working fluid velocity within the pump for the parameter combination investigated in this paper is approximately 618%.As the frequency is increased from 20 to 60 Hz,the maximum increase in the mean flow rate of the working fluid is approximately 241%.These research findings are intended to support the design and optimization of these devices.展开更多
The design of a pressurized capillary rheometer operating at prescribed temperature is described to measure the viscosity of magnetic fluids (MFs) containing Fe3O4 magnetic nanoparticles (MNPs). The equipment cons...The design of a pressurized capillary rheometer operating at prescribed temperature is described to measure the viscosity of magnetic fluids (MFs) containing Fe3O4 magnetic nanoparticles (MNPs). The equipment constant of the rheometer was obtained using liquids with predetermined viscosities. Experimentally measured viscosities were used to evaluate different equations for suspension viscosities. Deviation of measured suspension viscosities from the Einstein equation was found to be basically due to the influence of spatial distribution and aggregation of Fe3O4 MNPs. By taking account of the coating layer on MNPs and the aggregation of MNPs in MFs, a modified Einstein equation was proposed to fit the experimental data. Moreover, the influence of external magnetic field on viscosity was also taken into account. Viscosities thus predicted are in good agreement with experimental data. Temperature effect on suspension viscosity was shown experimentally to be due to the shear-thinning behavior of the MFs.展开更多
An ultrasensitive magnetic field sensor based on a compact in-fiber Mach–Zehnder interferometer(MZI) created in twin-core fiber(TCF) is proposed, and its performance is experimentally demonstrated. A section of TCF w...An ultrasensitive magnetic field sensor based on a compact in-fiber Mach–Zehnder interferometer(MZI) created in twin-core fiber(TCF) is proposed, and its performance is experimentally demonstrated. A section of TCF was spliced between two sections of standard single-mode fibers, and then a microchannel was drilled through one core of the TCF by means of femtosecond laser micromachining. The TCF with one microchannel was then immersed in a water-based Fe_3O_4 magnetic fluid(MF), forming a direct component of the light propagation path,and then sealed in a capillary tube, achieving a magnetic sensing element, which merges the advantages of an MZI with an MF. Experiments were conducted to investigate the magnetic response of the proposed sensor. The developed magnetic field sensor exhibits a linear response within a measurement range from 5 to 9.5 m T and an ultrahigh sensitivity of 20.8 nm/m T, which, to our best knowledge, is 2 orders of magnitude greater than other previously reported magnetic sensors. The proposed sensor is expected to offer significant potential for detecting weak magnetic fields.展开更多
In this study, silicone-oil-based γ-Fe2O3 mag- netic fluid was successfully prepared by thermal oxidizing of Fe3O4 magnetic nanoparticles, which were prepared by chemical co-precipitation with FeSO4-7H2O and FeCl3- 6...In this study, silicone-oil-based γ-Fe2O3 mag- netic fluid was successfully prepared by thermal oxidizing of Fe3O4 magnetic nanoparticles, which were prepared by chemical co-precipitation with FeSO4-7H2O and FeCl3- 6H2O, and their surface was modified by oleate ligands. Silicone oil was used as carrier liquid and oleic acid was as surfactant for preparing γ-Fe2O3 magnetic fluid. It is found that the Fe3O4 nanoparticles surrounded by oleate ligands are not damaged during the thermal oxidizing. The shape of γ-Fe2O3 magnetic nanoparticles prepared is similar to spherical, and their mean size is about 10-20 nm, which has nothing obvious difference compared with Fe3O4. Thesaturation magnetization of γ-Fe2O3 magnetic fluid pre-pared is 14.25 A.me.kg-1 and that of γ-Fe2O3 nanoparti-cles is 57.56 A.m2.kg-1. The needle of γ-Fe2O3 magneticfluid is much bigger than that of Fe3O4 magnetic fluidunder the same magnetic field, which shows better mag-netic properties.展开更多
The interaction between stabilizers and nanoparticles is one of the important factors to prepare stable magnetic fluids. The magnetic nano-size Fe3O4 core with single domain and the average grain size around 8-12 nm w...The interaction between stabilizers and nanoparticles is one of the important factors to prepare stable magnetic fluids. The magnetic nano-size Fe3O4 core with single domain and the average grain size around 8-12 nm were prepared by chemical precipitation method. The O/Fe molar ratio of the particle surface was measured by X-ray photoelectron spectroscopy (XPS). The heat effects of stabilizers ad- sorption on nanoparticles were measured by solution calorimetry. The excess amount of oxygen was possibly the result of the hydroxygen formed on the surface of the nanoparticles. The heat effects showed that compounds containing carboxyl groups can be adsorbed chemically on magnetite by forming chemical bonds. The other stabilizers involving NH-groups, such as polyethylene-imine, can be adsorbed physically. The exothermic value is about half of the former case.展开更多
The response time and transmittivity of the magnetic fluid (MF) for different concentrations at room temperature were investigated in this letter. The volume fraction of the investigated sample ranged from 0.44% to ...The response time and transmittivity of the magnetic fluid (MF) for different concentrations at room temperature were investigated in this letter. The volume fraction of the investigated sample ranged from 0.44% to 6.47%. It was found that the transmittivity decreased with increasing concentration under a given magnetic field, and the evolution time was changed with different concentrations. Moreover the light intensity decreased rapidly at the beginning and then became stable when the magnetic field was applied.展开更多
When the magnetic fluid lays in the magnetic field, interaction effects exist between them. Thus, the precise computation is considered as one of the precise methods of analyzing magnetic fluid in the magnetic field.C...When the magnetic fluid lays in the magnetic field, interaction effects exist between them. Thus, the precise computation is considered as one of the precise methods of analyzing magnetic fluid in the magnetic field.Comparing with it, the linear computation will bring more error. The more error exists between the decoupled computation and the linear computation, the more saturation magnetization does on the border. Besides, the value of magnetic flux density is bigger when using the decoupled computation than that of linear computation. What’s more,the equal magnetic flux density linear on the border varies slightly in the strong magnetic field when using the two computations. In a weaker magnetic field, the difference is bigger.展开更多
基金supported by the National Key Research and Development Program of China “National Quality Infrastructure” (Grant No. 2021YFF0600902)。
文摘The research of high-performance polarization controllers is of great significance for expanding the application field of polarization optics. Here, a polarization switch is demonstrated by using a dual-core photonic crystal fiber(DCPCF)with four symmetrical air holes, placed above and below each core, filled with magnetic fluid(MF). The switch, which utilizes a magnetic field to change the coupling length ratio of the x and y polarization modes, enables dynamic tuning of the polarization state and extinction ratio. Numerical results show that when the working length is 36.638 mm, the magneto–optical polarization switch can operate in four communication bands, i.e., 1509 nm to 1520 nm, 1544 nm to1556 nm, 1578 nm to 1591 nm, and 1611 nm to 1624 nm. Moreover, the extinction ratio(ER) is greater than 20 d B in the fiber length range of 38.5 mm to 38.7 mm, indicating that the device has a good fault tolerance for the interception of the fiber length.
基金Project supported by National High-Technology Research and De-velopment Program of China (Grant No .2002AA323070)
文摘Sealing is one of the most successful apphcatious of magnetic fluids. However, the sealing pressure difference is not satisfactory. This paper theoretically analyzes the mechanism of magnetic fluids sealing. Main factors that have significant effects on the sealing ability include viscous stress on the interracial surface, magnetic surface tension, and the shape of the interracial surface. The sealing pressure with magnetic fluids decreases with increase of rotational speed. Experiments were carried out to study the stability of the interface between magnetic fluids and water. It has been shown that stability of the interface will be damaged by washing of water when the relative flow between water and magnetic fluid becomes turbulent.
基金Project supported by the Natural Science Foundation of Tianjin City,China(Grant No.13JCYBJC16100)the National Natural Science Foundation of China(Grant No.61107035)+1 种基金the National Key Scientific Instrument and Equipment Development Project of China(Grant No.2013YQ03091502)the National Basic Research Program of China(Grant Nos.2010CB327802 and 2010CB327806)
文摘An all-fiber optical modulator, which is composed of a piece of no-core fiber spliced between two sections of singlemode fibers and uses magnetic fluid(MF) as the cladding of the no-core fiber section, is proposed and investigated experimentally. Due to the tunable refractive index and absorption coefficient of MF, the output intensity can be modulated by controlling an applied magnetic field. The dependences of the modulator's temporal response on the working wavelength,the magnetic field strength(H), and the MF's concentration are investigated experimentally. The results are explained qualitatively by the dynamic response process of MF under the action of a magnetic field. The findings are helpful for optimizing this kind of modulator.
基金supported by National Natural Science Foundation of China (Grant No. 50675027)
文摘Compared with traditional mechanical seals,magnetic fluid seals have unique characters of high airtightness,minimal friction torque requirements,pollution-free and long life-span,widely used in vacuum robots.With the rapid development of Integrate Circuit(IC),there is a stringent requirement for sealing wafer-handling robots when working in a vacuum environment.The parameters of magnetic fluid seals structure is very important in the vacuum robot design.This paper gives a magnetic fluid seal device for the robot.Firstly,the seal differential pressure formulas of magnetic fluid seal are deduced according to the theory of ferrohydrodynamics,which indicate that the magnetic field gradient in the sealing gap determines the seal capacity of magnetic fluid seal.Secondly,the magnetic analysis model of twin-shaft magnetic fluid seals structure is established.By analyzing the magnetic field distribution of dual magnetic fluid seal,the optimal value ranges of important parameters,including parameters of the permanent magnetic ring,the magnetic pole tooth,the outer shaft,the outer shaft sleeve and the axial relative position of two permanent magnetic rings,which affect the seal differential pressure,are obtained.A wafer-handling robot equipped with coaxial twin-shaft magnetic fluid rotary seals and bellows seal is devised and an optimized twin-shaft magnetic fluid seals experimental platform is built.Test result shows that when the speed of the two rotational shafts ranges from 0-500 r/min,the maximum burst pressure is about 0.24 MPa.Magnetic fluid rotary seals can provide satisfactory performance in the application of wafer-handling robot.The proposed coaxial twin-shaft magnetic fluid rotary seal provides the instruction to design high-speed vacuum robot.
基金supported by the National Natural Science Foundation of China (Grant No. 10704048)the Innovation Program of Shanghai Municipal Education Commission, China (Grant No. 11YZ120)the Innovation Fund Project for Graduate Student of Shanghai, China (Grant No. JWCXSL1022)
文摘Magnetic fluid is a kind of functional composite material with nanosized structure and unique optical properties. The tunable magneto-optic modulation of magnetic fluid under external magnetic field, achieved by adjusting the polarization direction of incident light, is investigated theoretically and experimentally in this work. The corresponding modulation depth and response time are obtained. The accompanying mechanisms are clarified by using the theory of dichroism of magtietic fluid and the aggregation/disintegration processes of magnetic particles within magnetic fluid when the external magnetic field turns on/off.
文摘A kind of photonic crystal (PC) micro-cavity sensor based on magnetic fluid (MF) filling is designed with simulation model. Generally, many sensors’ designs are based on a universal temperature in the whole structure. However, strong photothermal effect in high Q micro-cavities will lead to different temperatures between cavities and environment inevitably. In many theoretical PC sensor designs, researchers neglected the different temperature between environment and cavities. This simple hypothesis will probably lead to failure of sensor design and get wrong temperature. Moreover, few theoretical or experimental works have been done to study optical cavity’s heating process and temperature. We propose that researchers should take seriously about this point. Here, the designed cascaded micro-cavity structure has three spectral lines and a reversible sensitivity matrix, which can simultaneously detect magnetic field, ambient temperature and MF micro-cavity temperature. It can solve the magnetic field and temperature cross-sensitivity problem, and further, distinguish the different temperatures of environment and magnetic fluid cavities. The influence of hole radius and slab thickness on the depth and Q value of the resonant spectral line are also studied. Responses of three dips to magnetic field, ambient temperature and MF micro-cavity temperature are simulated, respectively, where dip 1 belongs to MF cavity 1, dip 2 and dip 3 belong to MF cavity 2. The obtained magnetic field sensitivities are 2.89 pm/Oe, 4.57 pm/Oe, and 5.14 pm/Oe, respectively;the ambient temperature sensitivities are 65.51 pm/K, 50.94 pm/K, and 58.98 pm/K, respectively;and the MF micro-cavity temperature sensitivities are −14.41 pm/K, −17.06 pm/K, and −18.81 pm/K, respectively.
基金Project 59573011 was supported by National Natural Science Foundation of China
文摘Fe_3O_4/Polystyrene(PSt) magnetic particles with core/shell structure have been prepared in thepresence of Fe_3O_4 magnetic fluid in ethanol/water medium by dispersion polymeriation of styrene. A Fe_3O_4particle formation mechanism was proposed. According to this mechanism, the size of particle nuclei isdetermined by the extent of aggregation of Fe_3O_4 /oligomer. Magnetic particles with diameter ranging from 5to 200 μm were prepared under different reaction conditions. Some polymerization parameters such as theconcentration of monomer, stabilizer, initiator, and ethanol which affect particle size and size distribution arediscussed and their effect on particle formation are explained by the proposed mechanism.
基金Project supported by the National Natural Science Foundation of China(Grant No.51675321)Shanghai Municipal Natural Science Foundation,China(Grant No.15ZR1415800)the Innovation Program of Shanghai Municipal Education Commission,China(Grant No.14ZZ092)
文摘A new controllable laser beam shaping technique is demonstrated, where a magnetic fluid-based liquid deformable mirror is proposed to redistribute the laser phase profile and thus change the propagation property of the beam. The mirror is driven by an inner miniature actuator array along with a large outer actuator. The inner actuator array is used for deforming the magnetic fluid surface, while the outer actuator is used to linearize the fluid surface response and amplify the magnitude of the deflection. In comparison to other laser beam shaping techniques, this technique offers the advantages such as simplicity, low cost, large shape deformation, and high adaptability. Based on a fabricated prototype of the liquid deformable mirror, an experimental AO system was set up to produce a desired conical surface shape that shaped the incident beam into a Bessel beam. The experimental results show the effectiveness of the proposed technique for laser beam shaping.
基金P.Z.S.PAZ is grateful for the financial support provided by Coordination for the Improvement of Higher Education Personnel-Brazil(CAPES)(Finance Code 001)National Council for Scientific and Technological Development-Brazil(CNPq)during the course of this research.F.R.CUNHA acknowledges the financial support of CNPq(No.305764/2015-2)Y.D.SOBRAL acknowledges the financial support of University of Brasilia(Call DPI/DPG No.02/2021).
文摘In this work,we present a theoretical study on the stability of a two-dimensional plane Poiseuille flow of magnetic fluids in the presence of externally applied magnetic fields.The fluids are assumed to be incompressible,and their magnetization is coupled to the flow through a simple phenomenological equation.Dimensionless parameters are defined,and the equations are perturbed around the base state.The eigenvalues of the linearized system are computed using a finite difference scheme and studied with respect to the dimensionless parameters of the problem.We examine the cases of both the horizontal and vertical magnetic fields.The obtained results indicate that the flow is destabilized in the horizontally applied magnetic field,but stabilized in the vertically applied field.We characterize the stability of the flow by computing the stability diagrams in terms of the dimensionless parameters and determine the variation in the critical Reynolds number in terms of the magnetic parameters.Furthermore,we show that the superparamagnetic limit,in which the magnetization of the fluids decouples from hydrodynamics,recovers the same purely hydrodynamic critical Reynolds number,regardless of the applied field direction and of the values of the other dimensionless magnetic parameters.
基金Project supported by the National Basic Research Program of China(Grant No.2015CB352001)the Shanghai Rising-Star Program+3 种基金China(Grant No.12QA1402300)the China Scholarship Council(CSC)Programthe Basic Research Program of ShanghaiChina(Grant No.14ZR1428500)
文摘The model of using colloidal magnetic fluid to build tunable negative-index photonic crystal is established. The effective permittivity εe and permeability μe of the two-dimensional photonic crystal are investigated in detail. For transverse magnetic polarization, both εe and μe exhibit a Lorentz-type anomalous dispersion, leading to a region where εe and μe are simultaneously negative. Then, considering a practical case, in which the thickness of photonic crystal is finite, the band structures for odd modes are calculated by the plane wave expansion method and the finite-difference time-domain method. The results suggest that reducing the external magnetic field strength or slab thickness will weaken the periodic modulation strength of the photonic crystal. Simulation results prove that the negative-index can be tuned by varying the external magnetic field strength or the slab thickness. The work presented in this paper gives a guideline for realizing the flat photonic crystal lens with tunable properties at optical frequencies, which may have potential applications in tunable near-field imaging systems.
基金Supported by the Joint Research Fund in Astronomy under Cooperative Agreement between the National Natural Science Foundation of China and Chinese Academy of Sciences under Grant No U1531102the Fundamental Research Funds for the Central Universities under Grant No HEUCF181116the National Natural Science Foundation of China under Grant Nos61107059,61077047 and 11264001
文摘We propose a novel light intensity modulator based on magnetic fluid and liquid crystal(LC) filled photonic crystal fibers(PCFs). The influences of electric and magnetic fields on the transmission intensity are theoretically and experimentally analyzed and investigated. Both the electric and magnetic fields can manipulate the molecular arrangement of LC to array a certain angle without changing the refractive index of the LC. Therefore, light loss in the PCF varies with the electric and magnetic fields whereas the peak wavelengths remain constant. The experimental results show that the transmission intensity decreases with the increase of the electric and magnetic fields. The cut-off electric field is 0.899 V/um at 20 Hz and the cut-off magnetic field is 195 m T. This simple and compacted optical modulator will have a great prospect in sensing applications.
基金the National Natural Science Foundation of China(No.52075468)the Natural Science Foundation of Hebei Province(No.E2020203052)+1 种基金the Key Scientific Research Projects of North China University of Technology(No.ZD-YG-202306-23)the Tangshan Science and Technology Project(No.23130201E).
文摘This paper analyzes the sources of heat losses in magnetic fluid bearings,proposes various cou-pling relationships of physical fields,divides the coupled heat transfer surfaces while ensuring the continuity of heat flux density,and analyzes the overall heat dissipation pathways of the bearings.By changing parameters such as input current,rotor speed,and inlet oil flow rate,the study applies a multi-physics field coupling method to investigate the influence of different parameters on the temper-ature field and heat dissipation patterns of the bearings,which is then validated through experi-ments.This research provides a theoretical basis for the optimal design of magnetic fluid bearing sys-tems.
基金supported by the National Natural Science Foundation of China(Grant Nos.51735006,51927810,and U1837206)Beijing Municipal Natural Science Foundation(Grant No.3182013).
文摘Magnetic fluids are the suspensions composed of magnetic nanoparticles,surfactants,and non-magnetic carrier liquids.Magnetic fluids are widely used in various fields,especially in sealing,because of their excellent features,including rapid magnetic response,flexible flow ability,tunable magneto-viscous effect,and reliable self-repairing capability.Here,we provide an in-depth,comprehensive insight into the theoretical analyses and diverse applications of magnetic fluids in sealing from three categories:static sealing,rotary sealing,and reciprocating sealing.We summarize the magnetic fluid sealing mechanisms and the development of magnetic fluid seals from 1960s to the present,particularly focusing on the recent progress of magnetic fluid seals.Although magnetic fluid sealing technology has been commercialized and industrialized,many difficulties still exist in its applications.At the end of the review,the present challenges and future prospects in the progress of magnetic fluid seals are also outlined.
文摘Magnetohydrodynamic(MHD)induction pumps are contactless pumps able to withstand harsh environments.The rate of fluid flow through the pump directly affects the efficiency and stability of the device.To explore the influence of induction pump settings on the related delivery speed,in this study,a numerical model for coupled electromagnetic and flow field effects is introduced and used to simulate liquid metal lithium flow in the induction pump.The effects of current intensity,frequency,coil turns and coil winding size on the velocity of the working fluid are analyzed.It is shown that the first three parameters have a significant impact,while changes in the coil turns have a negligible influence.The maximum increase in working fluid velocity within the pump for the parameter combination investigated in this paper is approximately 618%.As the frequency is increased from 20 to 60 Hz,the maximum increase in the mean flow rate of the working fluid is approximately 241%.These research findings are intended to support the design and optimization of these devices.
基金supported by the National Natural Science Foundation of China(NNSFC,Nos.20476065 and 20736004)the Scientific Research Foundation for the Returned Overseas Chinese Scholars of State Education Ministry,the State Key Laboratory of Multiphase Reaction of the Chinese Academy of Science(No.2003-5)the Key Laboratory of Organic Synthesis of Jiangsu Province,the Chemical Experiment Center of Soochow University and R&D Foundation of Nanjing Medical University(NY0586).
文摘The design of a pressurized capillary rheometer operating at prescribed temperature is described to measure the viscosity of magnetic fluids (MFs) containing Fe3O4 magnetic nanoparticles (MNPs). The equipment constant of the rheometer was obtained using liquids with predetermined viscosities. Experimentally measured viscosities were used to evaluate different equations for suspension viscosities. Deviation of measured suspension viscosities from the Einstein equation was found to be basically due to the influence of spatial distribution and aggregation of Fe3O4 MNPs. By taking account of the coating layer on MNPs and the aggregation of MNPs in MFs, a modified Einstein equation was proposed to fit the experimental data. Moreover, the influence of external magnetic field on viscosity was also taken into account. Viscosities thus predicted are in good agreement with experimental data. Temperature effect on suspension viscosity was shown experimentally to be due to the shear-thinning behavior of the MFs.
基金National Natural Science Foundation of China(NSFC)(61425007,61377090,61575128)Guangdong Science and Technology Department(2014A030308007,2014B050504010,2015B010105007,2015A030313541)+1 种基金Science and Technology Innovation Commission of Shenzhen(ZDSYS20140430164957664,GJHZ20150313093755757,KQCX20140512172532195,JCYJ20150324141711576)Pearl River Scholar Fellowships
文摘An ultrasensitive magnetic field sensor based on a compact in-fiber Mach–Zehnder interferometer(MZI) created in twin-core fiber(TCF) is proposed, and its performance is experimentally demonstrated. A section of TCF was spliced between two sections of standard single-mode fibers, and then a microchannel was drilled through one core of the TCF by means of femtosecond laser micromachining. The TCF with one microchannel was then immersed in a water-based Fe_3O_4 magnetic fluid(MF), forming a direct component of the light propagation path,and then sealed in a capillary tube, achieving a magnetic sensing element, which merges the advantages of an MZI with an MF. Experiments were conducted to investigate the magnetic response of the proposed sensor. The developed magnetic field sensor exhibits a linear response within a measurement range from 5 to 9.5 m T and an ultrahigh sensitivity of 20.8 nm/m T, which, to our best knowledge, is 2 orders of magnitude greater than other previously reported magnetic sensors. The proposed sensor is expected to offer significant potential for detecting weak magnetic fields.
基金financially supported by the National Natural Science Foundation of China (No.51274039)
文摘In this study, silicone-oil-based γ-Fe2O3 mag- netic fluid was successfully prepared by thermal oxidizing of Fe3O4 magnetic nanoparticles, which were prepared by chemical co-precipitation with FeSO4-7H2O and FeCl3- 6H2O, and their surface was modified by oleate ligands. Silicone oil was used as carrier liquid and oleic acid was as surfactant for preparing γ-Fe2O3 magnetic fluid. It is found that the Fe3O4 nanoparticles surrounded by oleate ligands are not damaged during the thermal oxidizing. The shape of γ-Fe2O3 magnetic nanoparticles prepared is similar to spherical, and their mean size is about 10-20 nm, which has nothing obvious difference compared with Fe3O4. Thesaturation magnetization of γ-Fe2O3 magnetic fluid pre-pared is 14.25 A.me.kg-1 and that of γ-Fe2O3 nanoparti-cles is 57.56 A.m2.kg-1. The needle of γ-Fe2O3 magneticfluid is much bigger than that of Fe3O4 magnetic fluidunder the same magnetic field, which shows better mag-netic properties.
基金Supported by the National Natural Science Foundation of China (Grant No. 50476039)Guangdong Provincial Department of Science and Technology (Grant No. 2004A10- 703001)
文摘The interaction between stabilizers and nanoparticles is one of the important factors to prepare stable magnetic fluids. The magnetic nano-size Fe3O4 core with single domain and the average grain size around 8-12 nm were prepared by chemical precipitation method. The O/Fe molar ratio of the particle surface was measured by X-ray photoelectron spectroscopy (XPS). The heat effects of stabilizers ad- sorption on nanoparticles were measured by solution calorimetry. The excess amount of oxygen was possibly the result of the hydroxygen formed on the surface of the nanoparticles. The heat effects showed that compounds containing carboxyl groups can be adsorbed chemically on magnetite by forming chemical bonds. The other stabilizers involving NH-groups, such as polyethylene-imine, can be adsorbed physically. The exothermic value is about half of the former case.
基金the National Natural Science Foundation of China(No.10574092)the National Basic Research Program"973"of China(No.2007CB307000)the Shanghai Leading Academic Discipline Project(No.B201)
文摘The response time and transmittivity of the magnetic fluid (MF) for different concentrations at room temperature were investigated in this letter. The volume fraction of the investigated sample ranged from 0.44% to 6.47%. It was found that the transmittivity decreased with increasing concentration under a given magnetic field, and the evolution time was changed with different concentrations. Moreover the light intensity decreased rapidly at the beginning and then became stable when the magnetic field was applied.
基金financially supported by the National Natural Science Foundation of China (Nos. 50707005 and 50977015)the Province Natural Science foundation of Heilongjiang (No. E201156)the Fundamental Research Funds for the Central Universities (Nos. HIT. NSRIF. 201139 and HIT. NSRIF. 201141)
文摘When the magnetic fluid lays in the magnetic field, interaction effects exist between them. Thus, the precise computation is considered as one of the precise methods of analyzing magnetic fluid in the magnetic field.Comparing with it, the linear computation will bring more error. The more error exists between the decoupled computation and the linear computation, the more saturation magnetization does on the border. Besides, the value of magnetic flux density is bigger when using the decoupled computation than that of linear computation. What’s more,the equal magnetic flux density linear on the border varies slightly in the strong magnetic field when using the two computations. In a weaker magnetic field, the difference is bigger.