期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Preliminary study in vitro brain tumor with high resolution magic angle spinning proton magnetic resonance spectroscopy 被引量:1
1
作者 Wei Tan Yaojun Ke Guangyao Wu 《The Chinese-German Journal of Clinical Oncology》 CAS 2008年第2期103-106,共4页
Objective: To explore water soluble metabolite features of brain tumor specimens with HRMAS-^1HMRS and its potential clinical value. Methods: There were thirty cases of pathologically proven brain tumor, including 6... Objective: To explore water soluble metabolite features of brain tumor specimens with HRMAS-^1HMRS and its potential clinical value. Methods: There were thirty cases of pathologically proven brain tumor, including 6 Ⅰ-Ⅱ grade astrocytomas, 7 Ⅲ grade anaplastic astrocytomas, 10 IV grade glioblastomas and 7 meningiomas. Used Varian Company 600 MHz spectrometer with the Nano-probe for acquisition HRMASJHMRS, which was postprocessed with jMRUI 3.2 version software. These metabolic probability and their ratios to Cr were summed. Results: (1) HRMAS-^1HMRS could resolve NAA, PCr/Cr, GPC ± PCho ± Cho, Glu/GIn, Gly, Tau, Ala, Lac, ml and so on. All samples showed Lac, 6 samples showed unknown single peak at 3.72 ppm or 3.90 ppm. (2) The mean Cho/Cr of 6 Ⅰ-ⅡI grade astrocytomas was 2.42 ± 1.01 (P = 0.003, compared with glioblastoma). The mean Cho/Cr of 7 anaplastic astrocytomas was 3.48 ± 0.59 (P = 0.01, compared with glioblastoma). The Cho/Cr of 10 glioblastomas broadly ranged from 0.9 to 11.3 (mean 5.40 ± 1.23). From Ⅰ-Ⅱ grade astrocytoma to glioblastoma, Ala/Cr, Tau/Cr and Gly/Cr trends were increased; the mean Ala/Cr of glioma was 0.31 ± 0.13. (3) Meningiomas showed higher Ala and Cho. Their Cr was lower than that of gliomas. 4/7 cases had no NAA, 3/7 patients had lower NAA. Mean Cho/Cr was 3.56 ± 1.01, Ala/Cr was 0.53 ±0.28 (P = 0.006, compared with glioma). Conclusion: HRMAS-^1HMRS can show further details in vivo MRS, resolve in vivo spectroscopic metabolite of Cho compound and differentiate the extent of benign and malignant glioma. With the increase in the malignant degree of gliomas, Cho, ml, Ala, Tau and Gly will increase. HRMAS-^1HMRS is the only method of isotropic spectroscopy for pathological specimens. 展开更多
关键词 magic angle spinning high resolution proton magnetic resonance spectroscopy in vitro brain tumor
下载PDF
DETECTION OF IGNEOUS BODIES IN HUAIBEI COAL MINESBY HIGH RESOLUTION MAGNETIC SURVEY
2
作者 王四龙 宁书年 +3 位作者 杨小勤 侯孝强 刘波 刘东林 《Journal of China University of Mining and Technology》 1996年第2期19-25,共7页
The present paper investigates the application of high resolution magnetic survey to detecting igneous bodies. The slight difference in magnetism between igneous bodies and their surrounding rocks is measured first an... The present paper investigates the application of high resolution magnetic survey to detecting igneous bodies. The slight difference in magnetism between igneous bodies and their surrounding rocks is measured first and then the magnetic survey data are processed to determine whether there exist igneous bodies by analog among several measuring lines, and finally the modified Marquart inversion was used to determine the occurrence and distribution of the igneous bodies. 展开更多
关键词 coal mines igneous bodies high resolution magnetic survey quantitative interpretation
下载PDF
APPLICATION OF HIGH-RESOLUTION MAGNETIC METHOD AND GRADIENT METHOD TO LOCATE ABANDONED BRINE-WELLS IN HUTCHINSON, KANSAS, U.S.A.
3
作者 CHEN Chao XIA Jianghai +2 位作者 XIA Sihao David Laflen Stephen L. Williams 《工程地球物理学报》 2004年第1期17-25,共9页
After successfully locating one abandoned brine well by an electromagnetic method during testing in 2001 and five abandoned brine wells by a high resolution magnetic method during 2002, a high resolution magnetic meth... After successfully locating one abandoned brine well by an electromagnetic method during testing in 2001 and five abandoned brine wells by a high resolution magnetic method during 2002, a high resolution magnetic method was again proposed to search for wells in 2003 when a second sensor was employed to acquire data for calculating the pseudo vertical gradient of magnetic fields. Total area surveyed in 2003 was 1,024,000 ft 2, which was divided into grids with an average size of 10,000 ft 2 and distributed across eight different sites. Magnetic anomalies and their vertical gradients from known brine wells were first recorded as signatures to identify anomalies caused by possible buried brine wells. Of fifty one verified anomalies, thirty one anomalies were due to wells buried at depths from 0 to 8.5 ft: twenty one 6 to 9 inch abandoned brine wells, seven 1.5 to 3 inch probable water wells, one 16 inch dewatering well for a construction site at a depth of 3 ft, and two 4 inch wells on the ground surface. Approximate monopole shaped anomalies were observed from all these wells after data corrections. However, the range of amplitudes of magnetic anomalies from 7,000 to 28,000 nT from these abandoned brine wells was measured. This range of anomalies is mainly due to the thickness and depth of buried wells. Anomaly amplitudes from 1.5 to 3 inch wells are 4,000 to 8,000 nT and linearly correlate with the buried depth. One 3 inch well that caused an anomaly of 13,000 nT could be the inner pipe of a brine well. Gradient anomalies are roughly in a range of 100 to 200 nT/inch for 1.5 to 3 inch wells and 200 to 300 nT/inch for brine wells.As indicated by the potential field theory, gradient data possess higher horizontal resolution than the magnetic field itself. Gradient data provide valuable assistance in determining horizontal locations of anomaly sources for excavation. In practice, however, improvement in the horizontal resolution is limited by survey line spacing. If only one sensor is used in a survey, there is rapid decrease in the horizontal resolution when sensor height increases from 14 to 44 inches. This indicates that it is critical to keep the sensor as close to the ground as possible when hunting buried wells that are close to each other. It also suggests that the downward continuation is useful to increase the horizontal resolution in well hunting. 展开更多
关键词 High resolution magnetic method magnetic gradient method Brine Well
下载PDF
New vacuum solar telescope and observations with high resolution 被引量:47
4
作者 Zhong Liu Jun Xu +18 位作者 Bo-Zhong Gu Sen Wang Jian-Qi You Long-Xiang Shen Ru-Wei Lu Zhen-Yu Jin Lin-Fei Chen Ke Lou Zhi Li Guang-Qian Liu Zhi Xu Chang-Hui Rao Qi-Qian Hu Ru-Feng Li Hao-Wen Fu Feng Wang Men-Xian Bao Ming-Chan Wu Bo-Rong Zhang 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2014年第6期705-718,共14页
The New Vacuum Solar Telescope (NVST) is a one meter vacuum solar telescope that aims to observe fine structures on the Sun. The main goals of NVST are high resolution imaging and spectral observations, including me... The New Vacuum Solar Telescope (NVST) is a one meter vacuum solar telescope that aims to observe fine structures on the Sun. The main goals of NVST are high resolution imaging and spectral observations, including measurements of the solar magnetic field. NVST is the primary ground-based facility used by the Chinese solar research community in this solar cycle. It is located by Fuxian Lake in southwest China, where the seeing is good enough to perform high resolution observations. We first introduce the general conditions at the Fuxian Solar Observatory and the primary science cases of NVST. Then, the basic structures of this telescope and instruments are described in detail. Finally, some typical high resolution data of the solar photosphere and chromosphere are also shown. 展开更多
关键词 telescopes -- instrumentation: adaptive optics -- instrumentation: spec-trographs -- techniques: high angular resolution -- Sun: magnetic fields
下载PDF
Wall Imaging for Unilateral Intracranial Vertebral Artery Hypoplasia with Three-dimensional High-isotropic Resolution Magnetic Resonance Images 被引量:17
5
作者 Xian-Jin Zhu Wu Wang +6 位作者 Bin DU Lei Liu Xin-Xin He Li-Bin Hu Xue-Bin Zhang Zun-Jing Liu Wei-Jian Jiang 《Chinese Medical Journal》 SCIE CAS CSCD 2015年第12期1601-1606,共6页
Background:There are few studies for evaluating wall characteristics of intracranial vertebral artery hypoplasia (VAH).The aim of this study was to determine wall characteristics of VAH with three-dimensional volum... Background:There are few studies for evaluating wall characteristics of intracranial vertebral artery hypoplasia (VAH).The aim of this study was to determine wall characteristics of VAH with three-dimensional volumetric isotropic turbo spin echo acquisition (3D VISTA) images and differentiate between acquired atherosclerotic stenosis and VAH.Methods:Thirty patients with suspicious VAH by luminograms were retrospectively enrolled between January 2014 and February 2015.The patients were classified as "acquired atherosclerotic stenosis" or "VAH" based on 3D VISTA images.The wall characteristics of VAH were assessed to determine the presence of atherosclerotic lesions,and the patients were classified into two subgroups (VAH with atherosclerosis and VAH with normal wall).Wall characteristics of basilar arteries and vertebral arteries were also assessed.The clinical and wall characteristics were compared between the two groups.Results:Five of 30 patients with suspicious VAH were finally diagnosed as acquired atherosclerotic stenosis by 3D VISTA images.25 patients were finally diagnosed as VAH including 16 (64.00%) patients with atherosclerosis and 9 (36.00%) patients with normal wall.In the 16 patients with atherosclerosis,plaque was found in 9 patients,slight wall thickening in 6 patients,and thrombus and wall thickening in 1 patient.Compared with VAH patients with normal wall,VAH patients with atherosclerosis showed atherosclerotic basilar arteries and dominant vertebral arteries more frequently (P =0.000).Conclusions:Three-dimensional VISTA images enable differentiation between the acquired atherosclerotic stenosis and VAH.VAH was also prone to atherosclerotic processes. 展开更多
关键词 ATHEROSCLEROSIS High resolution magnetic Resonance Images Vertebral Artery Hypoplasia
原文传递
Decoding brain responses to pixelized images in the primary visual cortex: implications for visual cortical prostheses 被引量:4
6
作者 Bing-bing Guo Xiao-lin Zheng +4 位作者 Zhen-gang Lu Xing Wang Zheng-qin Yin Wen-sheng Hou Ming Meng 《Neural Regeneration Research》 SCIE CAS CSCD 2015年第10期1622-1627,共6页
Visual cortical prostheses have the potential to restore partial vision. Still limited by the low-resolution visual percepts provided by visual cortical prostheses, implant wearers can currently only "see" pixelized... Visual cortical prostheses have the potential to restore partial vision. Still limited by the low-resolution visual percepts provided by visual cortical prostheses, implant wearers can currently only "see" pixelized images, and how to obtain the specific brain responses to different pixelized images in the primary visual cortex(the implant area) is still unknown. We conducted a functional magnetic resonance imaging experiment on normal human participants to investigate the brain activation patterns in response to 18 different pixelized images. There were 100 voxels in the brain activation pattern that were selected from the primary visual cortex, and voxel size was 4 mm × 4 mm × 4 mm. Multi-voxel pattern analysis was used to test if these 18 different brain activation patterns were specific. We chose a Linear Support Vector Machine(LSVM) as the classifier in this study. The results showed that the classification accuracies of different brain activation patterns were significantly above chance level, which suggests that the classifier can successfully distinguish the brain activation patterns. Our results suggest that the specific brain activation patterns to different pixelized images can be obtained in the primary visual cortex using a 4 mm × 4 mm × 4 mm voxel size and a 100-voxel pattern. 展开更多
关键词 nerve regeneration primary visual cortex electrical stimulation visual cortical prosthesis low resolution vision pixelized image functional magnetic resonance imaging voxel size neural regeneration brain activation pattern
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部